• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.028 seconds

Detection of Edwardsiella tarda, the Pathogenic Bacteria in Freshwater Fishes by Means of the Indirect Fluorescent Antibody Technique (간접형광항체법을 이용한 담수양식어의 병원균 Edwardsiella tarda의 검출)

  • 류해진;조우영;이청산;허강준
    • Korean Journal of Veterinary Service
    • /
    • v.16 no.2
    • /
    • pp.111-119
    • /
    • 1993
  • In this study, we carried out the rapid diagnostic system based on indirect fluorescent anti-body technique (IFAT) for detection of bacterial diseases in cultured freshwater fishes. 1. When the fishes were tested with graded dilution of Edwardsiella tarda FPC 470 bacteria detection from ten fishes Injected with $4.1{\times}10^3$colony forming unit(CFU) /ml, all of them were detected by IFAT but only two fishes were recognizable by the culture method in the tested fishes injected with $4.1{\times}10^3$CFU /ml. 2. The bacteria E. tarda could be detected by IFAT method from 1 to 48hrs after Injection in the tissues tested such as kidney, liver and spleen of the fishes, whereas detection by culture method could be recognized from 1 to 48hrs after injection In the kidney and spleen but it was not possible from preinjection to 1 hr in the liver. 3. Thus, IFAT proved to be more useful technique than plate culture method in the diagnosis of Edwardsiellosis in the freshwater fishes.

  • PDF

Effects of Alanine and Glutamine Supplementation on Alcohol Metabolism in ICR Mice

  • Jonghee Chyun;Jungeun Yim;Youngnam Cha
    • Nutritional Sciences
    • /
    • v.5 no.1
    • /
    • pp.9-12
    • /
    • 2002
  • This study was conducted to investigate the effects of oral supplementation of alanine and glutamine on alcohol metabolism. The subjects were 70 male ICR mice weighing 25-30 g. The animals were raised on standard rations artier weaning. After 24 hours of fasting, all the animals were given a peritoneal injection of 20% alcohol. Then, they were randomly divided into two groups: control and experimental. Fifteen minutes after the injection of alcohol, the mice in the experimental group wer given an oral solution of alanine(5 mM, 2 g/kg B. W) and glutamine (5 mM, 2g/kg B.W). The concentration of alcohol in the blood was measured in all the mice 20 minutes after they received the alochol, and the measurements continued every 20 minutes up to 140 minutes. The experimental group sustained lower blood alcohol levels at every 20 minute time interval compared to the control group, showing that oral supplementation of alanine and glutamine increases the rate of alcohol metabolism. Furthermore, the total amount of alcohol remaining in the blood, determined by using the Area Under the Curve (AUG) method, was lower in the group supplemented with alanine and glutamine, However, the effectiveness of alanine and glutamine in increasing the rate of alcohol metabolism, compared to the control group, diminished with time throughout the experiment. In conclusion, alanine and glutamine supplementation appears to promote alcohol metabolism shorthy after alcohol intake.

Are women with small endometriomas who undergo intracytoplasmic sperm injection at an elevated risk for adverse pregnancy, obstetric, and neonatal outcomes?

  • Verit, Fatma Ferda;Kucukakca, Ayse Seyma Ozsuer
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.1
    • /
    • pp.80-84
    • /
    • 2021
  • Objective: The aim of the study was to investigate pregnancy, obstetric, and neonatal outcomes in women with small (<4 cm) unilateral endometriomas. Methods: This retrospective study included 177 patients: 91 patients with small endometriomas and 86 controls with unexplained or tubal factor infertility who were treated at the Süleymaniye Gynecology and Maternity Training and Research Hospital Infertility Unit between January 2010 and July 2015. The groups were matched with regards to demographic characteristics such as age, body mass index, and infertility duration. All of the women in this study conceived via intracytoplasmic sperm injection. We compared pregnancy, obstetric, and neonatal outcomes between these groups. Results: Women with endometriomas had a higher biochemical pregnancy rate, but lower clinical pregnancy and live birth rates than women with unexplained and tubal factor infertility (p<0.05 for all). However no significant differences were found in terms of obstetric and neonatal complications between the two groups (p>0.05 for all). Conclusion: In this study, we found that women with endometriomas less than 4 cm were more prone to early pregnancy complications. We also showed that this group did not have any increased risks of late pregnancy, obstetric, and neonatal complications.

Study on Spray Characteristics of Single-Hole GDI Injector according to Nozzle Hole Diameter - (2) Comparison of Spray Uniformity and Atomization Characteristics (노즐 홀 직경에 따른 단공 GDI 인젝터의 분무 특성 연구 - (2) 분무 균일도 및 미립화 특성 비교)

  • Park, Jeonghyun;Ro, Seungcheon;Chang, Mengzhao;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.154-161
    • /
    • 2020
  • A single spray plume is the basic unit of the entire spray plume and is an important factor in understanding the spray characteristics. However, since the multi-hole GDI injector has a narrow spray angle, the superposition of the spray plumes occurs severely. Therefore, the spray uniformity and the spray atomization characteristics of a single spray plume were analyzed in this study using a single-hole GDI injector. Five single-hole GDI injectors with different nozzle hole diameters were used in the experiment. The uniformity of the spray was evaluated through the analysis of the spray pattern images. In addition, the atomization characteristics were compared using the diameter distribution of the spray droplets obtained using PDPA. As a result, the larger diameter of the nozzle hole, the less uniformity of the spray, and the injection pressure did not have a significant effect on the spray uniformity. It is judged that the surface roughness of the injector has a greater effect on spray uniformity than the diameter of the nozzle hole. Also, the size of the spray droplets increased sharply when the diameter of the nozzle hole was 230 ㎛.

A Study on the Comparison of Emissions and Fuel Efficiency Performance of 2.0 Liter LPG Hybrid Engine and Vehicle (2.0 리터급 LPG 하이브리드 엔진 및 차량의 배출가스 및 연비성능 비교에 관한 연구)

  • Seokjoo Kwon;Bonseok Koo;Jaehoon Kang;Kangmyeon Kim;Sedoo Oh;Youngho Seo
    • Journal of ILASS-Korea
    • /
    • v.28 no.4
    • /
    • pp.191-197
    • /
    • 2023
  • LPG direct injection (LPDi) technology is a method of improving the weaknesses of existing LPG vehicles by directly injection into the combustion chamber. This study was conducted on the comparison of emissions and fuel efficiency performance of the engine and vehicle by applying LPDi technology. The LPDi hybrid engine's maximum output and maximum torque were measured at an equivalent level of less than 1% compared to conventional gasoline fuel. The fuel amount was corrected using the LCU controller, and the THC, CO, and NOx emissions were reduced to 90% in the operating range of the three-way catalyst through air-fuel ratio control. The analysis of THC+NOx and CO emissions in FTP-75 (CVS-75) driving mode satisfied the US LEV III SULEV30 regulation.

BIM-BASED TIME SERIES COST MODEL FOR BUILDING PROJECTS: FOCUSING ON MATERIAL PRICES

  • Sungjoo Hwang;Moonseo Park;Hyun-Soo Lee;Hyunsoo Kim
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.1-6
    • /
    • 2011
  • As large-scale building projects have recently increased for the residential, commercial and office facilities, construction costs for these projects have become a matter of great concern, due to their significant construction cost implications, as well as unpredictable market conditions and fluctuations in the rate of inflation during the projects' long-term construction periods. In particular, recent volatile fluctuations of construction material prices fueled such problems as cost forecasting. This research develops a time series model using the Box-Jenkins approach and material price time series data in Korea in order to forecast trends in the unit prices of required materials. Building information modeling (BIM) approaches are also used to analyze injection times of construction resources and to conduct quantity take-off so that total material prices can be forecast. To determine an optimal time series model for forecasting price trends, comparative analysis of predictability of tentative autoregressive integrated moving average (ARIMA) models is conducted. The proposed BIM-based time series forecasting model can help to deal with sudden changes in economic conditions by estimating material prices that correspond to resource injection times.

  • PDF

Replication of concave and convex microlens array of light guide plate for liquid crystal display in injection molding (음각, 양각 광학패턴 적용 휴대폰용 도광판 금형 제작 및 광특성 연구)

  • Hwang, Chul Jin;Kim, Jong Sun;Kang, Jeong Jin;Hong, Seokkwan;Yoon, Kyung Hwan
    • Design & Manufacturing
    • /
    • v.2 no.2
    • /
    • pp.29-32
    • /
    • 2008
  • A back light unit (BLU) is a key module of a thin film transistor liquid crystal display (TFT-LCD), frequently utilized in various mobile displays. In this study, we experimentally characterize transcription and optical properties of concave and convex microlens arrays (MLAs) of light guide plate (LGP) fabricated by injection molding with polycarbonate as a LGP substrate material. Nickel mold inserts were manufactured by electroforming on the MLA which was fabricated by the thermal reflow of photoresist microstructures patterned by UV-photolithography. For the case of convex microlens, the height of replicated microlens was less than that of the mold insert while maintaining almost the same microlens diameter of the mold insert as the location of the microlens is far from the gate. In contrast, for the concave microlens, the diameter of replicated microlens was larger than that of mold insert, while showing almost the same microlens height as the mold insert. From the optical examination of replicated convex and concave MLAs, it was found that a higher luminance of the LGP was achieved by the concave MLAs compared to the convex MLAs (about 30% enhancement in this case)due to the utilization of a larger amount of light provided by the light sources.

  • PDF

Study on the OLED Thin Film Encapsulation of the Al2O3 Thin Layer Formed by Atomic Layer Deposition Method (원자층 증착방법에 의한 Al2O3 박막의 OLED Thin Film Encapsulation에 관한 연구)

  • Kim, Ki Rak;Cho, Eou Sik;Kwon, Sang Jik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.67-70
    • /
    • 2022
  • In order to prevent water vapor and oxygen permeation in the organic light emitting diodes (OLED), Al2O3 thin-film encapsulation (TFE) technology were investigated. Atomic layer deposition (ALD) method was used for making the Al2O3 TFE layer because it has superior barrier performance with advantages of excellent uniformity over large scales at relatively low deposition temperatures. In this study, the thickness of the Al2O3 layer was varied by controlling the numbers of the unit pulse cycle including Tri Methyl Aluminum(Al(CH3)3) injection, Ar purge, and H2O injection. In this case, several process parameters such as injection pulse times, Ar flow rate, precursor temperature, and substrate temperatures were fixed for analysis of the effect only on the thickness of the Al2O3 layer. As results, at least the thickness of 39 nm was required in order to obtain the minimum WVTR of 9.04 mg/m2day per one Al2O3 layer and a good transmittance of 90.94 % at 550 nm wavelength.

Pharmacokinetic Modeling of Reversible Interconversion between Prednisolone and Prednisone (가역적상호대사과정 모델을 이용한 Prednisolone과 Prednisone의 약동학적 분석)

  • Shin, Jae-Gook;Yoon, Young-Ran;Cha, In-June;Jang, In-Jin;Lee, Kyung-Hoon;Shin, Sang-Goo
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.2
    • /
    • pp.269-281
    • /
    • 1996
  • Pharmacokinetics of prednisolone and prednisone undergoing reversible interconversion were analyzed from the model including this metabolic process. Blood samples were drawn serially upto 12 hours after I,V. bolus injection of 1 mg/kg prednisolone sodium phosphate and prednisone into 8 dogs as a crossover manner. Plasma concentrations of those two steroids were simultaneously measured with the method of HPLC. After injection, plasma concentrations of administered prednisolone and prednisone were declined with a biexponential pattern and their metabolic partner was rapidly formed. Plasma concentrations of those metaboite were decayed in parallel with their parent steroids throught the elimination phase. Apparent clearances of prednisolone and prednisone were $11.1{\pm}2.0\;ml/min/kg$ and $45.9{\pm}6.4\;ml/min/kg$, and they were underestimated by 29.4% and 33.6% compared to their real clearances$(15.7{\pm}4.4\;and\;69.2{\pm}17.7\;ml/min/kg)$ estimated using reversible interconversion model. Apparent volume of distribution of prednisolone$(1.32{\pm}0.43\;L/kg)$ and prednisone$(4.81{\pm}2.75\;L/kg)$ were overestimated by 53.5 and 52.7% and were compared to the real volumes $(0.86{\pm}0.30\;and\;3.15{\pm}2.13\;L/kg)$. Mean residence time of prednisolone$(2.0{\pm}0.61\;h)$ and prednisone$(1.74{\pm}0.74\;h)$ were much longer than the real sojourn time$(0.93{\pm}0.26\;and\;0.88{\pm}0.54\;h)$. Essential clearances In the reversible interconversion were greater as following orders: $Cl_{21}$(44.3 ml/min/kg) > $Cl_{20}$(24.2 ml/min/kg) > $Cl_{12}$ (7.9 ml/min/kg) > $Cl_{10}$(7.8 ml/min/kg). Estimated mean values of RF, EE, $%X^1_{ss}$ and $RHO^2_1$ were $0.31{\pm}0.10$, $1.49{\pm}0.23$, $69.3{\pm}16.7%$ and $0.65{\pm}0.10$, respectively. These results suggested that true pharmacokinetic parameters estimated from the model including reversible interconversion were significantly different from the apparent parameters estimated from the conventional mamillary model, and disposition of these two steroids seemed to be well explained by the model including reversible interconversion.

  • PDF

A study on process optimization of diffusion process for realization of high voltage power devices (고전압 전력반도체 소자 구현을 위한 확산 공정 최적화에 대한 연구)

  • Kim, Bong-Hwan;Kim, Duck-Youl;Lee, Haeng-Ja;Choi, Gyu-Cheol;Chang, Sang-Mok
    • Clean Technology
    • /
    • v.28 no.3
    • /
    • pp.227-231
    • /
    • 2022
  • The demand for high-voltage power devices is rising in various industries, but especially in the transportation industry due to autonomous driving and electric vehicles. IGBT module parts of 3.3 kV or more are used in the power propulsion control device of electric vehicles, and the procurement of these parts for new construction and maintenance is increasing every year. In addition, research to optimize high-voltage IGBT parts is urgently required to overcome their very high technology entry barrier. For the development of high-voltage IGBT devices over 3.3 kV, the resistivity range setting of the wafer and the optimal conditions for major unit processes are important variables. Among the manufacturing processes to secure the optimal junction depth, the optimization of the diffusion process, which is one step of the unit process, was examined. In the diffusion process, the type of gas injected, the injection time, and the injection temperature are the main variables. In this study, the range of wafer resistance (Ω cm) was set for the development of high voltage IGBT devices through unit process simulation. Additionally, the well drive in (WDR) condition optimization of the diffusion process according to temperature was studied. The junction depth was 7.4 to7.5 ㎛ for a ring pattern width of 23.5 to25.87 ㎛, which can be optimized for supporting 3.3 kV high voltage power devices.