• Title/Summary/Keyword: Injection Site

Search Result 558, Processing Time 0.028 seconds

Adjuvant Effect of PAMAM Dendrimer on the Antigenicity of Keyhole Limpet Hemocyanin in Balb/c Mice (Balb/c 마우스에서 Keyhole limpet hemocyanine (KLH)의 항원성에 대한 PAMAM dendrimer 의 면역증강 효과)

  • Lee, Ga-Young;Kim, Min Jee;Kim, So Yeon;Lee, Kyung Bok;Oh, Dong Hyun;Cho, Young Ho;Yoo, Yung Choon
    • Journal of Life Science
    • /
    • v.30 no.10
    • /
    • pp.905-911
    • /
    • 2020
  • The adjuvant effect of PAMAM dendrimer G4 (PAMAM) on the induction of humoral and cellular immune responses against keyhole limpet hemocyanin (KLH) was examined. Mice were immunized subcutaneously twice at two-week intervals with KLH, with or without PAMAM dendrimer (100 ㎍/mouse), and the mice immunized with KLH+PAMAM showed significantly higher antibody titers against KLH than those immunized with KLH alone. The assay for determining the isotypes of the antibodies showed that PAMAM augmented the KLH-specific antibody titers of IgG1, IgG2a, IgG2b, IgG3, and IgM. In addition, mice immunized twice with KLH+PAMAM followed by a subcutaneous injection of KLH (20 ㎍/site) 7 weeks after the primary immunization exhibited a higher delayed-type hypersensitivity (DTH) reaction than those treated with KLH alone. In an in vitro analysis of T lymphocyte proliferation in response to KLH in week 8, the splenocytes of mice treated with KLH+PAMAM showed significantly higher proliferating activity than those treated with KLH alone, and the culture supernatants of cell cultures from mice immunized with added PAMAM dendrimer showed higher levels of KLH-specific cytokine (IL-4 and IFN-r) production. These results suggest that PAMAM dendrimer G4 possesses a potent immune-adjuvant activity for enhancing both humoral and cell-mediated immunity specific to foreign antigens.

Immunogenicity and Reactogenicity of Inactivated HM175 Strain Hepatitis A Vaccine in Healthy Korean Children (건강한 한국 소아에서 HM175주 A형 간염 불활화 백신의 면역원성 및 이상반응에 관한 연구)

  • Kim, Chang Hwi;Pyun, Bok Yang;Hong, Young Jin;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.120-128
    • /
    • 2000
  • Purpose : Active immunization against hepatitis A with an inactivated vaccine reveals excellent immunogenicity, tolerability and protective efficacy. Inactivated hepatitis A vaccines have been selectively used since 1996 in Korea to prevent hepatitis A. This study was performed to assess the immunogenicity and reactogenicity after two doses of HM175 strain hepatitis A vaccine in healthy Korean children. Methods : 128 healthy children(M/F; 65/63) aged 1 to 15 years, who were seronegative for hepaitatis A, participated in this study. A alum-adsorbed vaccine containing 720 EL.U of antigen form HM175 hepatitis A strain per 0.5 mL dose was injected intramuscularly on the deltoid area. The second dose was given 6 months later, Anti-HAV antibodies were measured by ELISA before and 1 month after each vaccination to assess the immunogenicity. Any local and general adverse events were reported by patients parents with the prepared questionnaire after each vaccination. Results : 120 volunteers(M/F; 60/60) completed the whole series of the study. Seroconversion occurred in all cases after primary and booster vaccination. The mean anti-HAV antibody titer after primary vaccination was 389.2mIU/mL, and 3,609mIU/mL after booster vaccination. And levels of anti-HAV antibodies after booster immunization were significantly higher in female children. The most common local adverse event was soreness on the injection site, but it was mild and resolves within 3 days. Fever was not reported after booster vaccination. Conclusion : Based on these data, we conclude that the inactivated HM175 strain hepatitis A vaccine is highly immunogenic and tolerable in healthy Korean children.

  • PDF

Usefulness of Low Dose Oral Contrast Media in $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 저용량 경구용 조영제의 유용성)

  • An Young-Sil;Yoon Joon-Kee;Hong Seon Pyo;Joh Chul-Woo;Yoon Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • Purpose: The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in $^{18}F-FDG$ PET/CT. Materials and Methods: We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oval contrast agent (barium sulfate) was administered immediately before injection of $^{18}F-FDG$. The FDG uptake of intestines was analyzed by visual and semi- quantitative method on transaxial, coronal and saggital planes. Results: Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (15%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n=27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. Conclusion: We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

Evaluation of Standardized Uptake Value applying Prompt Gamma Correction on 68Ga-DOTATOC PET/CT Image (68Ga-DOTATOC PET/CT에서 Prompt Gamma Correction을 적용한 SUV의 평가)

  • Yoon, Seok Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • $^{68}Ga$ was eluted from a $^{68}Ge/^{68}Ga$ radionuclide generator. $^{68}Ga$ decays into $^{68}Zn$, with a half life=67.8min. The decay is 88.9 % by ${\beta}$+ and 11.1 % by EC. The main ${\beta}$+ decay (87.7 %) is to the ground level of $^{68}Zn$ and it is a pure positron emission branch. A small fraction decays ${\beta}$+ (1.2 %) into an excited level of $^{68}Zn$, which promptly decays into the ground level with a ${\gamma}$ (1.077 Mev). This can constitute prompt gamma contamination in the PET data, if the 1.077 Mev ${\gamma}$ has a scatter interaction in the patient, and generates a lower energy ${\gamma}$ in coincidence with the positron annihilation pair. The purpose of this study was to evaluate standardized uptake value(SUV) before and after applying prompt gamma rays correction on $^{68}Ga$-DOTATOC PET/CT image. Fifty patient underwent PET/CT 1 hour after injection of the $^{68}Ga$-DOTATOC. The SUVmax and SUVmean of lesions and normal tissues (Pituitary, Lung, Liver, Spleen, Kidney, Intestine) were evaluated before and after applying prompt gamma correction on $^{68}Ga$-DOTATOC PET/CT image. Additionally, the SUVmax of each lesions and SUVmean of the soft tissues were measured on images. and target to background ratios (TBR) were calculated as quantitative indices. Among 15 patients, 25 of lesions (Pancreas, Liver, Thoracic Spine, Brain) with increased uptake on $^{68}Ga$-DOTATOC PET/CT image. SUVmax and SUVmean were increased in lesion site and normal tissue after prompt gamma rays correction. TBR was $51.51{\pm}49.28$ and $55.50{\pm}53.12$ before and after prompt gamma rays correction, respectively. (p<0.0001)

The immunogenicity and reactogenicity of Td booster vaccination in Korean preadolescents, aged with 11-12 years old (국내 11-12세 소아에서 Td 백신 추가접종의 면역원성과 안전성 평가)

  • Lee, Soo Young;Kwak, Ga Young;Mok, Hye Rin;Kim, Jong Hyun;Hur, Jae Kyun;Lee, Kyung Il;Park, Joon Su;Ma, Sang Hyuk;Kim, Hwang Min;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1185-1190
    • /
    • 2008
  • Purpose : This study was undertaken to evaluate the immunogenicity and reactogenicity of Td booster immunization in early preadolescents of Korea. Methods : Healthy preadolescents, who had been vaccinated with 4 or 5 doses of DTaP vaccines until 6 years old age, were enrolled in this study from August 2006 to April 2007. Diphtheria and tetanus anti-toxoid antibodies in sera were measured by ELISA just before vaccination and 4 weeks after vaccination to evaluate immunogenicity. Local and systemic adverse reactions observed for 4 weeks after vaccination to access reactogenicity. Results : 183 preadolescents were enrolled and mean age was $11.40{\pm}0.51$ years old. All subjects achieved seroprotective diphtheria and tetanus anti-toxoid antibodies (titers ${\geq}0.1IU/mL$) after Td booster vaccination. Among 183 vaccinees, 73.8% showed local adverse reactions and 37.2% systemic adverse reactions. Pain at injection site (66.1%) was the most common local reaction, and the most commonly shown systemic reaction was myalgia (17.5%). The adverse reactions were spontaneously relieved within three days after vaccination. Conclusion : Td vaccine in this study was high immunogenic and showed an acceptable tolerance in Korean preadolescents. Td booster vaccination at 11-12 years old is the most effective method to increase compliance of the vaccination and to decrease the incidence of diphtheria and tetanus.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Use of Chicken Meat and Processing Technologies (가금육의 이용과 가공기술)

  • Ahn, Dong-Uk
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.07b
    • /
    • pp.67-88
    • /
    • 2003
  • The consumption of poultry meat (chicken and turkey) grew the most during the past few decades due to several contributing factors such as low price. product research and development. favorable meat characteristics, responsive to consumer needs, vertical integration and industry consolidation, new processing equipments and technology, and aggressive marketing. The major processing technologies developed and used in chicken processing include forming/restructuring, tumbling, curing, smoking, massaging, injection, marination, emulsifying, breading, battering, shredding, dicing, and individual quick freezing. These processing technologies were applied to various parts of chicken including whole carcass. Product developments using breast, thigh, and mechanically separated chicken meat greatly increased the utilization of poultry meat. Chicken breast became the symbol of healthy food, which made chicken meat as the most frequent menu items in restaurants. However, the use of and product development for dark meat, which includes thigh, drum, and chicken wings were rather limited due to comparatively high fat content in dark meat. Majority of chicken are currently sold as further processed ready-to-cook or ready-to-eat forms. Major quality issues in chicken meat include pink color problems in uncured cooked breast, lipid oxidation and off-flavor, tenderness PSE breast, and food safety. Research and development to ensure the safety and quality of raw and cooked chicken meat using new processing technologies will be the major issues in the future as they are now. Especially, the application of irradiation in raw and cooked chicken meat products will be increased dramatically within next 5 years. The market share of ready-to-eat cooked meat products will be increased. More portion controlled finished products, dark meat products, and organic and ethnic products with various packaging approaches will also be introduced.

  • PDF

INFLUENCE OF TOPICAL IRRIGATION USING THE HA & PURE Ti IMPLANTS ON BONE FORMATION;A STUDY ON THE IRRADIATED RABBIT TIBIA (방사선 조사후 매식한 임프란트와 관주에 따른 골치유에 대한 비교연구)

  • Hong, Sung-Pal;Rhee, Gun-Joo;Cha, Yong-Doo;Oh, Se-Jong;Hyun, Jung-Min;Choi, Dong-Joo;Park, Young-Joo;Park, Jon-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • In this study, the rate of bone formation and the pattern of bone to implant contact surface around HA coated implant and pure Ti implant inserted into the irradiated tibia of rabbit were compared. Sixteen mongrel mature male rabbits were used as experimental animal. Each rabbit received 15 Gy of irradiation. Four weeks after irradiation, two holes were prepared on the tibia of each rabbit for placement of HA coated type and pure Ti type implants. Prior to implant placement, one group received steroid irrigation and the control group was similarly irrigated with normal saline. This was immediately followed by placement of the two different types of implants. Postoperatively, tetracycline was injected intramuscularly for 3 days. For fluorescent labelling, 3 days of intramuscular alizarine red injection was given. 2 weeks before sacrifice, followed by intramuscular calcein green on the last 3 days before specimen collection. Each rabbit was sacrificed on the second, fourth, sixth and eighth week after the implantation. The specimens were observed by the light microscope and the fluorescent microscope. The results were as follows; 1. All implants inserted into the irradiated tibia of rabbit were free from clinical mobility and no signs of bony resorption were noted around the site of implant placement. 2. Under the light microscope, new bone formation proceeded faster around implants that received steroid irrigation compared to the control group irrigated with saline. Bone to implant contact surface was greater in the steroid irrigated group than the saline irrigated group. Therefore, better initial stabilization was observed in the group pretreated with steroid irrigation. 3. Under the light microscope. HA coated implants showed broader bone to implant contact surface than pure Ti implants, and HA coated implants had better bone healing pattern than pure Ti implants. 4. In the steroid pretreated group, acceleration of bone formation was demonstrated by fluorescent microscopy around the 2, 4 weeks group and the 6 weeks HA coated implant group. The difference in the rate of bone formation proved to be statistically significant(P<0.05). Faster bone formation was noted in the saline irrigated group in the 6 weeks pure Ti implants and 8 weeks group. The difference was not statistically significant(P<0.05). 5. For the rabbits that were sacrificed on the second and fourth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. For the rabbits that were sacrificed on the sixth week after the implant placements, the rates of bone formation around pure Ti implants proceeded faster than those around HA coated implants under the fluorescent microscopy. But this result did not show statistical significance (P<0.05) For the rabbits that were sacrificed on the eighth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. This result was statistically significant (P<0.05).

  • PDF