• Title/Summary/Keyword: Injection Flow Rate

Search Result 713, Processing Time 0.03 seconds

Analysis of Post-LOCA pH for Korea Nuclear Units (국내 원자력발전소의 LOCA사고에 따른 pH 분석)

  • Hyung Won Lee;Yung Hee Kang;Jae Hee Kim
    • Nuclear Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.179-187
    • /
    • 1983
  • The pH of containment spray and sump water following a LOCA for KNU 5'||'&'||'6 and KNU 1 was calculated to see if pH design criteria of containment spray system established by USNRC were met. The pH calculations have been made for the two cases; maximum pH and minimum pH. For KNU 5'||'&'||'6, results showed that long term sump pH values calculated for the maximum pH and minimum pH case well met the pH requirement of at least 8.5 and spray pH for the maximum case slightly exceeded the range of design criteria (8.5 to 11.0). For KNU 1, pH requirement of long term sump pH was also met, however, spray pH value for the maximum pH case was very largely greater than that of current pH requirement. (No pH requirement of containment spray water has been established at the time of designing KNU 1) In order to find the design parameters of containment spray system which are expected to meet the spray pH requirement, several calculations were wade, by changing the input parameters to "LCCAPH". Finally, it was shown that the boric acid concentration in RWST (refueling water storage tank), which was the primary sources of containment spray water during injection mode, be maintained the range of 2750 ppm to 2850 ppm, or tile flow rate of NaOH added to spray water he kept between 10 gpm to 24 gpm.

  • PDF

Pharmacokinetics of Anticancer Agent SB-31 in Rats & Rabbits and the Cardiovascular Effect on the Isolated Perfused Rat Heart & Blood Coagulation (SB-31의 Glycyrrhizin을 지표로 한 Rat과 Rabbit에서의 약물동태 및 심혈관계에 대한 효과 연구)

  • Kang, Won Ku;Park, Yong Soon;Lee, Dong Heum;Kwon, Kwang Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.122-132
    • /
    • 1998
  • SB-31 which contains Pursatilla, Licoris and Ginseng extracts was recently proved as an anticancer agent. In a preclinical effort to be applied this drug to human, pharmacokinetics of SB-31 was carried out in rats and rabbits. Glycyrrhizin(GZ), a saponin of Licoris was used as a standard ingradient for the pharmacokinetics of SB-31. The rat's blood, bile and urine samples were serially collected in femoral vein, common bile duct and bladder, respectively, after bolus i.v. injection at a dose of 1 or 1/5 ampul/rat and rabbit's blood samples from the marginal ear vein at a dose of 1 or 3 amp./rabbit. GZ and glycyrrhetic acid(GA), a major metabolite of GZ in the physiological samples were analysed by HPLC with UV detection. The decline of GZ in plasma concentration was generally biexponential at each dose. GZ was almost completely recovered in bile within 18 hour. GA wasn't detected in the samples with UV detector. In the rat, Vss and Kel at a dose of 1 and 1/5 ampul of SB-31 were $98.06\pm6.07\;ml,\;0.33\pm0.05\;hr^{-1}\;and\;65.46\pm11.19\;ml,\;0.68\pm0.25\;hr^{-1}$, respectively. Those in rabbits at a dose of 3 and 1 ampul of SB-31 were $235.24\pm30.72\;ml,\;0.13\pm0.36\;hr^{-1}\;and\;341.32\pm28.58\;ml,\;0.27\pm0.04\;hr^{-1}$, respectively. 'WinNonlin' was utilized for the compartmental analysis. A two-compartment model was chosen as the most appropriate pbarmaco-kinetic model. The data were best described by using a weighting factor of $1/y^2$. To evaluate the effect of SB-31 on cardiovascular system, serially diluted SB-31 was directly injected into coronary artery in the isolated perfused rat heart and the effect of PSF, PSH, saponins of Pursatilla, and SB-31 on PT, APTT of healthy human plasma was examined. Except the positive inotropic effect of ten times diluted solution of SB-31, there was no significant effect on LVDP, (- dp/dt)/(+dp/dt), heart rate and coronary flow in comparision with that of vehicle. SB-31 had no effect on PT but slightly delayed APTT about $6.9{\sim}11.5\%$. There was no significant effect of PSF and PSH on PT & APTT. Conclusively, SB-31 did not show any notable toxic effects on cardiovascular system.

  • PDF

A Study on the Activated Carbon Injection and Filtration Process for Removal of Chlorinated Organic Compound in the Incinerator Flue Gas (활성탄의 분무 여과에 의한 소각로 배가스 중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Due to the toxicity of dioxin in the incinerator flue gas, it becomes a severe social problem. Activated carbon adsorption process is one of the methods for removing dioxin in the flue gas and was investigated its performance for removing hazardous organic compounds. Since dioxin is very hazardous material, 1,2-dichlorobenzene(o-DCB), one of the precursor material of dioxin, was used as adsorbate. The effects of air flow rate, pressure drop in the bag filter, operation temperature of bag filter, and kinds of adsorbents on the removal of o-DCB were measured and analysed. Experimental results showed that the operating temperature was recommended within the range of $140{\sim}170^{\circ}C$ considering the operating condition of incinerator. Also it was necessary to maintain the pressure drop of bag filter $120mmH_2O$ for enhancing the adsorption at the surface layer of activated carbon formed on the bag filter. The use of mixture of same amount of activated carbon and diatomite showed more than 90% removal of o-DCB and also reduced the consumption of activated carbon.

  • PDF

Spinal Anesthesia for Lower Extremities : Comparison of Plain 0.5% Bupivacaine and Hyperbaric 0.5% Tetracaine (하지수술을 위한 0.5% 순수 Bupivacaine 척추마취)

  • Song, Sun-Ok;Koo, Bon-Up
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 1990
  • Plain 0.5% bupivacaine and hyperbaric 0.5% tetracaine were compared for spinal anesthesia in 40 patients undergoing operation of lower extremities. Lumbar puncture was performed with a 22 gauge spinal needle with the patient in the lateral recumbent position. The third lumbar interspace was chosen for the puncture, when a free flow of clear CSF was obtained, the local anesthetic solution (2.5ml of 0.5% bupivacaine or 2.0ml of hyperbaric 0.5% tetracaine) was injected at a rate of 0.1ml/sec without barbotage. After injection of anesthetics, clinical features were observed and compared between the two groups. The results were as follows : 1. The two groups were well matched for age, sex, height and weight. 2. In both groups, sensory block to $T_{12}$ dermatome was obtained within 4 minutes, mean maximal level of analgesia was $T_{6-7}$, and the mean time for maximal level was around 20 minutes. 3. The onset times of motor block were similar in both groups and complete motor block was obtained in all cases within 20 minutes. 4. The duration of analgesia above the $T_{12}$ dermatome was 3 hours, postoperative analgesia was 7 hours. These values were significantly prolonged than those of the tetracaine group(p<0.05). 5. The changes in systolic pressure in the bupivacaine group were significantly less than those of the tetracaine group(p<0.05). 6. The complications after spinal anesthesia were headache, numbness, urinary retention and backpain, and were no significant difference in both groups. From the obtained results, we concluded that plain 0.5% bupivacaine was a relatively satisfactory agent for spinal anesthesia for operation of lower extremities. The time of onset, height of block and the complications of postoperative period were similar in both groups. The advantages of plain 0.5% bupivacaine were less hypotension and long duration of analgesia.

  • PDF

Performance Characteristics of the 300 MW Integrated Gasification Combined Cycle Plant according to Ambient Temperature (대기온도에 따른 300 MW 석탄가스화복합발전 성능특성)

  • Kim, Young-Mook;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.3
    • /
    • pp.29-34
    • /
    • 2018
  • In this study, the output and thermal efficiency of Taean Integrated Gasification Combined Cycle Plant were calculated by using the manufacturer's basic design data and the performance correction factor for each atmospheric temperature, and the actual performance was measured at summer and winter representative points. The results were compared with the calculated values to verify their validity. The thermal efficiency is the highest at around $15^{\circ}C$ and lower at lower temperature and higher temperature. This is similar to that of natural gas Combined Cycle Power Plant, but the thermal efficiency has drastically decreased due to the increase of power consumption of the air separation unit at relatively high temperature. The output is highest in the range of 5 to $15^{\circ}C$, and is kept almost constant at below $5^{\circ}C$ and declines above $15^{\circ}C$. The reason why the output does not increase at low temperatures is that the torque limit of the shaft is activated by the increase of the flow rate due to the nitrogen injection of the gas turbine combustor. In order to improve the performance in the future, efforts should be made to improve the power generation output and to reduce the power consumption of the air separation unit in summer.

  • PDF

Geomechanical Stability of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) using Coupled Thermal-Hydraulic-Mechanical Analysis (열-수리-역학적 연계해석을 이용한 복공식 지하 압축공기에너지 저장공동의 역학적 안정성 평가)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.394-405
    • /
    • 2011
  • In this paper, we applied coupled non-isothermal, multiphase fluid flow and geomechanical numerical modeling using TOUGH-FLAC coupled analysis to study the complex thermodynamic and geomechanical performance of underground lined rock caverns (LRC) for compressed air energy storage (CAES). Mechanical stress in concrete linings as well as pressure and temperature within a storage cavern were examined during initial and long-term operation of the storage cavern for CAES. Our geomechanical analysis showed that effective stresses could decrease due to air penetration pressure, and tangential tensile stress could develop in the linings as a result of the air pressure exerted on the inner surface of the lining, which would result in tensile fracturing. According to the simulation in which the tensile tangential stresses resulted in radial cracks, increment of linings' permeability and air leakage though the linings, tensile fracturing occurred at the top and at the side wall of the cavern, and the permeability could increase to $5.0{\times}10^{-13}m^2$ from initially prescribed $10{\times}10^{-20}m^2$. However, this air leakage was minor (about 0.02% of the daily air injection rate) and did not significantly impact the overall storage pressure that was kept constant thanks to sufficiently air tight surrounding rocks, which supports the validity of the concrete-lined underground caverns for CAES.

A Study on $Na^+$ and Water Reabsorption in the Nephron Segment Beyond Proximal Tubule Measured by Lithium Clearance

  • Han, O-Soo;Goo, Yong-Sook;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.189-200
    • /
    • 1991
  • During the past few years it has been proposed that lithium clearance can be used as a reliable measure for the outflow of tubular fluid from the proximal tubule. This study was aimed to characterize the inflow dependent reabsorption of Na in renal tubule beyond the proximal tubule. For this purpose, lithium clearance was used as a measure for the inflow from the proximal tubule and the changes in reabsorption fraction of Na and water were determined in rabbits. Rabbits were pretreated with hypotonic saline solutions for an hour (50 mM/L NaCl, 20 ml/hr/kg). And then a hypertonic solution of 500 mM/L NaCl (20 ml/kg) was administered intraperitoneally in conjunction with a bolus of LiCl solution (2 mM/kg, i.v.) for conditioning the $C_{Li}$ and urine flow rate. To rule out the effect of $Li^+$ on tubular functions, a bolus of NaCl solution (2 mM/kg, i.v.) was administered. Fifteen, thirty, and sixty minutes after injection of hypertonic saline arterial blood and urine samples were taken. Urinary and plasma concentrations as well as urinary output of $Li^+,\;Na^+\;and\;K^+$ were measured. From these $C_{Li},\;C_{Na}$ and the reabsorption fraction of Na and water $(Fr_{Na}\;&\;FrH_2O)$ were calculated. These results were compared with those from control groups in which the same amount of isotonic saline (145 mM/L NaCl) and of 15% dextran solution were administered in the same way as that in experimental group. Followings are the results obtained. 1) The plasma concentration of $Na^+$ in rabbits injected with hypertonic saline reached the peak value after 15 min and thereafter no significant change was observed. Hematocrit values did not show any change, while urinary excretion of $Na^+$ increased markedly during the first 15 min and decreased thereafter. These results were not affected by an injection of a small amount of LiCl. 2) The clearances of $Li^+,\;Na^+\;and\;K^+$ in rabbits injected with hypertonic saline and LiCl solution decreased. 3) In spite of the variation in $C_{Li},\;Fr_{Na}$ did not show any significant change while $FrH_2O$ increased gradually. 4) $C_{Li}$ decreased also in rabbits received isotonic saline. $Fr_{Na}$ tended to be higher than that in hypertonic saline group, while $FrH_2O\;and\;Fr_{Na}$ did not associated with the decrease in $C_{Li}$. 5) $C_{Li}$ of the rabbits received dextran solution fluctuated persistently and $Fr_{Na}\;and\;FrH_2O$ did not change in along with $C_{Li}$ although $Fr_{Na}$ had a tendency to be higher than that in hypertonic saline group. 6) From the above results it was concluded that: (a) In rabbits with normal body store of $Na^+$, the $Fr_{Na}$ of renal tubule beyond proximal tubule. calculated from $C_{Li}$ as a measure of inflow from proximal tubule is constant in spite of variations in $C_{Li}$. (b) The $FrH_2O$ calculated from $C_{Li}$ is dependent largely upon ADH rather than inflow from proximal tubule. (c) When there is a decrease in plasma $Na^+$ concentration or ineffective body fluid. $Li^+$ reabsorption may occur in the thick segnent of Henle's loop and hence the determination of $Fr_{Na}$ and $FrH_2O$ will not be easy one, but $Fr_{Na}$ is constant under the same experimental conditions.

  • PDF

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.

THE ANTICANCER EFFECT OF PACLITAXEL($Taxol^{(R)}$) IN ORAL SQUAMOUS CELL CARCINOMA XENOGRAFT (이종 이식된 구강편평세포 암종에서 Paclitaxel ($Taxol^{(R)}$)의 항암 효과)

  • Kim, Ki-Hwan;Kim, Chul-Hwan;Han, Se-Jin;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.95-110
    • /
    • 2006
  • The treatment for oral and maxillofacial carcinoma with chemotherapeutic agents is evaluated by many effective methods to reduce the tumor mass and cancer cell proliferation. However these chemotherapy have many serious side effects, such as bone marrow suppression, renal toxicity, G-I troubles. Therefore a possible approach to develop a clinically applicable chemotherapeutic agent is to screen anticancer activity of Taxol which is known to have very little side effect and have been used to breast cancer and ovarian carcinoma. Taxol is a new anti-microtubular anti-cancer agent extracted from the bark of the Pacific yew, Taxus brevifolia. Paclitaxel(Taxol) acts by promoting tubulin polymerization and over stabilizing microtubules agianst depolymerization. Despite the constant improvements of methods of the cancer treatment especially chemotherapy, the rate of cancer metastasis and recurrent are not decreased. Thus the investigation of new drug which have very little side effect and a possible clinically application continues to be a high priority. Considering that the Taxol have shown very effective chemotherapeutic agent with relatively low toxicity in many solid tumors, it deserves to evaluate its efficacy in oral squamous cell carcinoma. In this study, to investigate the in-vivo and in-vitro anti-cancer efficacy of Taxol in oral squamous cell carcinoma and lastly, the potency of Paclitaxel in the clinical application for oral cancer was evaluated. In vivo study, after HN22 cell line were xenografted in nude mice, the growth of tumor mass was observed, 3 mg/Kg taxol was injected intraperitoneally into nude mice containing tumor mass. The methods of these study were measurement of total volume of tumor mass, histopathologic study, immunohistochemical study, drug resistance assay, growth curve, MTT assay, flow cytometry, cDNA microarray in vivo and in vitro. The results were obtained as following. 1. The visual inspection of the experimental group showed that the volume of the tumor mass was slightly decreased but no significant difference with control group. 2. Ki-67 index was decreased at weeks 4 in experimental group. 3. Microscopic view of the xenografted tumor mass showed well differentiated squamous cell carcinoma and after Taxol injection, some necrotic tissue was seen weeks 4. 4. The growth curve of the tumor cells were decreased after 1day Taxol treatment. 5. According to the MTT assay, HN22 cell line showed relative drug resistancy above $5\;{\mu}g/ml$ concentrations of Taxol. 6. In drug resistance assay, the decrease of cell counts was seen relatively according to concentration. 7. In Flow cytometry, G2M phase cell arrests were seen in low concentration of the Taxol, while S phase cell arrests were seen in high concentration of the Taxol. 8. Using cDNA microarray technique, variable gene expression of ANGPTL4, TXNRD1, FAS, RRAGA, CTGF, CYCLINEA, P19, DUSP5, CEBPG, BTG1 were detacted in the oral squamous cell carcinoma cell after taxol treatment. In this study paclitaxel is effective against oral squamous cell carcinoma cell lines in vitro, but week effect was observed in vivo. So we need continuous study about anticancer effect of taxol in vivo in oral squamous cell carcinoma.

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.