A Study of Droplets and Icing Characteristics on Injector in a Liquid Phase LPG Injection Engine (액상분사식 LPG엔진 인젝터의 후적 및 아이싱 특성에 관한 연구)

  • Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong;Park, Cheol-Woong
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Since the Liquid Phase LPG injection (LPLI) system has Advantages in power generation and emission characteristics compared to the mixer-type fuel-supply system, a variety of studies regarding LPLi system has been conducted and its applications are made in automobile industry. However, the heat extraction due to the evaporation of liquid fuel, causes not only a post-accumulation of fuel but also an icing phenomenon which is a frost of moisture in the air around the nozzle tip. Since there exists a difficulty in the accurate control of air fuel ratio in both fuel supply systems, it can result in poor engine performance and a large amount of harmful emissions. This research examines the characteristics of icing phenomenon and develops anti-icing bushing to prevent an icing on the surface of the injection tip. It was found that n-butane, which has a relatively high boiling point ($-0.5^{\circ}C$), was a main species of post-accumulation. Also the results show that the post-accumulation problem was allevaited the utilization of a large inner to outer bore ratio and smooth surface roughness. In addition, an icing phenomenon and its formation process were found to be mainly affected by the humidity and the temperature of inlet air in an inlet duct. Also, it was observed that an icing phenomenon is lessened using aluminum bushing whose end coincides with the end of fuel injection tip in length.

  • PDF

A Study on the Development of an Automatic Multi-Nozzle Injection Molding Machine (Multi-Nozzle Injection Molding Automatic Machine 개발에 관한 연구)

  • Lee, Jong-Hyung;Kim, Jung-Hwan;Yi, Chang-Heon;Kim, Yun-Gon;Lim, Chun-Kyoo;Lee, Chun-Kon;Kwon, Yung-Shin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.123-128
    • /
    • 2007
  • The demand for the precision rubber products has been rapidly increasing with the recent growth of industries. And the requirement for the productivity and the quality calls out for the injection molding machines with the precision machining ability as well as the high productivity. Especially modern automobile industry is in urgent need of developing injection molding machines for the high quality rubber products with high productivity. And the inability of the domestic companies to meet the standards causes importing foreign machines and as a result spending good amount of dollars. It is extremely important to develop competitive machines and strengthen the infrastructure of the related industries. In this paper the functions and the structure of a automatic multi-nozzle injection molding machine has been studied to set up a proper test system for the precision rate and the reliability of the machines, which can help build the machines to meet the request of the industry.

  • PDF

Optimized mix design of rapid-set lightweight-formed mortar for backfill (굴착복구용 속경성 경량기포 시멘트 모르타르의 최적 배합 도출을 위한 기초 물성 연구)

  • An, Ji-Hwan;Jeon, Sung-il
    • International Journal of Highway Engineering
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • PURPOSES : The objective of this study is to develop an optimized method of mix design for rapid-set lightweight-formed mortar mix. To achieve this objective, the workability, setting time, and compressive strength of mixes under various conditions of mix design were evaluated. METHODS : The water-bonder ratio, fly-ash substitution ratio, and forming agent injection amount were selected as design variables in the study. The fluidity, setting time, density, and strength of the mortar mix were considered as major evaluation criteria of the mixture, and were subsequently utilized to evaluate the characteristics of the mortar mix under various conditions. RESULTS : The observations made from the mix design process are as follows: 1) the air content and fluidity increase as the forming agent ratio and forming agent ratio increase, respectively; 2) the maximum air content is approximately 20%; 3) the accelerating agent decreases the fluidity of the mortar mix by 15% on average; 4) the forming agent injection ratio and fly-ash substitution ratio yield significant effects on the initial and final set times of the mortar mix; 5) as the forming agent injection ratio and fly-ash substitution ratio increase, the compressive strength of the mortar mix decreases; and 6) the 28-day compressive strengths of the forming agent injection ratio and fly-ash substitution ratio yield the most significant effects. CONCLUSIONS : It is concluded that the governing design variables for the rapid-set lightweight-formed mortar mix are the forming agent injection ratio and fly-ash substitution ratio.

Injection Effects of Coagulant and Flocculant on Bulking Change of Dredged Soils (준설토 체적변화에 대한 응집제 및 응결제의 주입효과)

  • 윤길림;유승경
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.257-264
    • /
    • 2003
  • Bulking change between sediments and dredged soils occurs when dredged soils are fully disturbed by dredging process and settled down to stabilized conditions in the basin. Bulking of dredged soils are affected by chemical injection, coagulant and flocculant, to speed up settling process of the suspended solids. In this paper, bulking changes of dredged soils are investigated by experimental works regarding injection effects of the coagulant and flocculant. Dredged sediments were sampled in the lagoon located at the East Coast, and the bulking change of dredged soils is quantitatively analysed by changing the clay content and the amount of the coagulant and flocculant. The optimal amounts of the coagulant and flocculant are determined based on minimal bulking change due to coagulant and flocculant injection. From the experimental results, the bulking of dredged soils increased 1.69 times on the average and the bulking change rate slightly increased as clay content increasea due to injection of the coagulant and flocculant.

Design of Tritium Handling System(II): Injection System, Regeneration System (삼중수소취급계통의 설계(II): 주입계통, 재생계통)

  • 김광신;김경숙;정은수;손순환;김위수
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.117-123
    • /
    • 2003
  • In succession to the previous paper, the tritium injection system and the regeneration system of the tritium handling system are presented. Both systems should be placed inside glove boxes since there can be potential leakage of tritium from these systems. The tritium injection system should be capable of measuring the exact amount of the injected tritium to keep track of the tritium inventory. The tritium injection system is designed to recover the remaining tritium from the system after injection for the minimization of tritum release to the environment as well as for the recovery of precious resource. TRS equipment such as MS, Ni catalyst bed, and metal getter are regenerated with a standalone regeneration system. Unlike other equipments which can be regenerated by heating and purging with appropriate gas, regeneration of the metal getter used to recover tritium is somewhat complicated.

  • PDF

Development and Reliability Verification of Quality Control System for Compaction Grouting Method (컴팩션 그라우팅 공법의 품질관리 시스템 개발 및 신뢰성 검증)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Jung, Eui-Youp;Park, Sang-Yeong;Lee, Hyo-Bum
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.11-20
    • /
    • 2020
  • This study introduced the compact grouting method that can be used for improving soft ground and restoring buildings with unequal subsidence. The pump used in the traditional compact grouting method is a system that injects one hole each, which reduces the construction efficiency, and the analog injection method manually manages the construction by field workers, making it difficult to manage consistent quality. Pump and quality control system were developed to solve problems in existing construction. Since field supervisor determines amount of injected materials by using analog equipment and controls manually, it is difficult to manage consistent quality of construction. Therefore, the quality control system was developed in order to solve that problem. The quality control system consists of automatic mixing system of injection materials, multiple simultaneous injection pumps, and injection management monitoring system. Performance of the quality control system was verified through on-site testing, and ground improvement performance was verified through quality testing after testing and testing of the compact grouting method. Therefore, it is expected that the integrated quality control system developed will improve the quality assurance and efficiency and stability of construction at sites where construction and quality verification are difficult.

Comparison of the Effects of Intratympanic Steroid Injection at Different Intervals in Sudden Sensorineural Hearing Loss

  • Sung, Han Kyung;Kang, Ju Chang;Shin, Kyu Ha;An, Yun Suk
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Background and Objectives: Systemic steroid therapy (SST) and intratympanic steroid injection (ISI) have been the treatment of choice for sudden sensorineural hearing loss (SSNHL). We studied the effect of ISI administered at different intervals on hearing outcomes in patients with SSNHL. Subjects and Methods: We performed a retrospective study of 427 patients diagnosed with SSNHL at Bundang Jesaeng Hospital, of whom 51 patients with SSNHL who received SST and four ISIs were included in this study. Patients were treated with four ISIs either every day for 4 days (group 1) or at intervals (mean duration of interval: 2.21 days) (group 2). Hearing outcomes were evaluated using the pure-tone test before the injection and 14 days, 1 month, and 3 months after the final injection. Recovery rates were classified based on Siegel's criteria. Results: The amount of improvement was 27.67 dB (±20.45) in group 1 and 32.79 dB (±21.42) in group 2. However, there were no significant differences between the two groups (p= 0.714). The recovery rates based on Siegel's criteria were 18/27 (66.7%) and 16/24 (66.7%) in groups 1 and 2, respectively, with no significant difference (p=1.000). Considering only complete recoveries in hearing recovery, the recovery rates were 15/27 (55.6%) and 14/24 (58.3%) in groups 1 and 2, respectively, with no significant difference (p=0.842). Conclusions: There were no significant differences in hearing outcomes or recovery rates after ISI administration every day or at intervals of 2-3 days.

Comparison of the Effects of Intratympanic Steroid Injection at Different Intervals in Sudden Sensorineural Hearing Loss

  • Sung, Han Kyung;Kang, Ju Chang;Shin, Kyu Ha;An, Yun Suk
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Background and Objectives: Systemic steroid therapy (SST) and intratympanic steroid injection (ISI) have been the treatment of choice for sudden sensorineural hearing loss (SSNHL). We studied the effect of ISI administered at different intervals on hearing outcomes in patients with SSNHL. Subjects and Methods: We performed a retrospective study of 427 patients diagnosed with SSNHL at Bundang Jesaeng Hospital, of whom 51 patients with SSNHL who received SST and four ISIs were included in this study. Patients were treated with four ISIs either every day for 4 days (group 1) or at intervals (mean duration of interval: 2.21 days) (group 2). Hearing outcomes were evaluated using the pure-tone test before the injection and 14 days, 1 month, and 3 months after the final injection. Recovery rates were classified based on Siegel's criteria. Results: The amount of improvement was 27.67 dB (±20.45) in group 1 and 32.79 dB (±21.42) in group 2. However, there were no significant differences between the two groups (p= 0.714). The recovery rates based on Siegel's criteria were 18/27 (66.7%) and 16/24 (66.7%) in groups 1 and 2, respectively, with no significant difference (p=1.000). Considering only complete recoveries in hearing recovery, the recovery rates were 15/27 (55.6%) and 14/24 (58.3%) in groups 1 and 2, respectively, with no significant difference (p=0.842). Conclusions: There were no significant differences in hearing outcomes or recovery rates after ISI administration every day or at intervals of 2-3 days.

Comparison of Control Performance according to the Injection Voltage Waveform of the Harmonic Voltage Injection Sensorless Technique (주입 전압파형의 형상에 따른 고조파 주입 센서리스 기법의 제어 성능 비교)

  • Moon, Kyeong-Rok;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.43-49
    • /
    • 2022
  • This paper compares the sensorless control performance according to the applied voltage waveform by injecting sinusoidal, triangular, and square waveform in the harmonic injection sensorless control method. By injecting various voltage shape waveform with a frequency of 1kHz, the error amount of the estimated angle for each waveform is compared and analyzed. For the experiment, the HILS(hardware in the loop simulation) system was used. The hardware is the control board, and the inverter and motor models implemented in Simulik are located in the real-time simulator. The control algorithm is implemented by the FPGA control board, which includes a PWM interrupt service routine with a frequency of 10 kHz, harmonic injection and position detection sensorless algorithm.

A Comparison on the Operative Results of Benign Esophageal Disease by Video-Assisted Thoracic Surgery and Thoracotomy (양성 식도질환에서 개흉술과 비디오 흉강경을 이용한 수술 성적의 비교)

  • 정성호;박승일;오정훈;송태승;김현조;김동관;손광현;최인철
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.738-743
    • /
    • 2000
  • Background: Video-assisted thoracic surgery(VATS) is being used as a therapeutic modality in many diseases in which thoracotomy has been used. We studied that the VATS can substitute the thoracotomy in benign esophageal disease. Material and Method: Group I (n=18) underwent video-assisted thoracic surgery, and group II(n=19) thoracotomy. Group I includes 14 leiomyomas and 4 achalasias. Group II includes 16 leiomyomas and 3 achalasias. Operative technique is enucleation in the leiomyoma and modified Heller's myotomy in the achalasia. Analyzing factors of operation-efficacy are anesthetic time, operation time, hospital stay, chest tube drainage amount and chest tube removal day. The degree of the postoperative pain is assessed by the frequency of opioid analgesics injection. Result: There was no death in both groups. There were 5 complications in the group I and 2 in the group II. Prolonged pleural effusion and restenosis of achalasia occurred to 1 patient in each group. In the group I, there were 1 temporaty vocal cord palsy and 2 mucosal tear leading to thoracotomy. There were no differences in anesthesia time, operation time, hospital stay, total chest tube drainage amount, chest tube removal day and frequency of opioid analgesics injection. The amount of the chest tube drainage at POD 1 day was significantly lower in group I(155.6$\pm$77.8cc) than in group II(572.8$\pm$280.1cc)(p<0.05). Conclusion: The results of our data showed that video-assisted thoracic surgery for benign esophageal disease is as effective as thoracotomy and in addition, cosmetic effect is much better. We concluded VATS may be a substitute for thoracotomy in benign esophageal disease.

  • PDF