• 제목/요약/키워드: Initial-phase sensitivity

검색결과 46건 처리시간 0.023초

Initial-phase Sensitivity Analysis of Harmonic Measurements via Windowed DFT

  • Song, Shuping;Wang, Fuzong;Cheng, Guozhu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2014
  • When the windowed DFT algorithm is applied in harmonic measurements, the problem of initial-phase sensitivity will be encountered, this has an effect on harmonic amplitude accuracy. In this paper, the origin of initial-phase sensitivity is analyzed and the main factors that influence the level of initial-phase sensitivity are demonstrated. A method of reducing initial-phase sensitivity is proposed to increase the stability of harmonic measurements. We found that initial-phase sensitivity is determined by the side lobe peak level of the window functions when synchronous deviation is fixed. In addition, increasing the length of the time recorded can be used to remove initial-phase sensitivity. The correctness and validity of our conclusions have been confirmed through numerical results and field tests.

AN EFFECT ANLYSIS OF RISK FACTORS FOR BUILD TRANSFER LEASE PROJECTS

  • Yang-Woo Lee;Soo-Yong Kim; Jung-Man Jung;Dae-Young Kim
    • 국제학술발표논문집
    • /
    • The 2th International Conference on Construction Engineering and Project Management
    • /
    • pp.498-508
    • /
    • 2007
  • The Build-Transfer-Lease (BTL) projects have rapidly increased under the Government support during recent years. This paper presents the risk analysis of factors affecting BTL projects in the initial phase. This study resulted in 10 significant risk factors influencing on each phase of BTL projects and then factors were grouped into each phase. The sensitivity analysis was also performed to identify risk factors with more significant influence on BTL projects. The results may useful to practitioners in order to cope with risks in initial phase of BTL projects. The paper resulted in the distribution of risks to project parties, thus it can be used as standards for risk assignment to competent authorities and private enterprises of BTL projects.

  • PDF

종동력을 받는 진동계의 케이오틱 거동 연구 (Chaotic response of a double pendulum subjected to follower force)

  • 이재영;장안배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.295-300
    • /
    • 1996
  • In this study, the dynamic instabilities of a nonlinear elastic system subjected to follower force are investigated. The two-degree-of-freedom double pendulum model with nonlinear geometry, cubic spring, and linear viscous damping is used for the study. The constant and periodic follower forces are considered. The chaotic nature of the system is identified using the standard methods, such as time histories, phase portraits, and Poincare maps, etc.. The responses are chaotic and unpredictable due to the sensitivity to initial conditions. The sensitivities to parameters, such as geometric initial imperfections, magnitude of follower force, and viscous damping, etc. is analysed. The strange attractors in Poincare map have the self-similar fractal geometry. Dynamic buckling loads are computed for various parameters, where the loads are changed drastically for the small change of parameters.

  • PDF

구강방어아동을 위한 능동적 구강놀이와 ASI적용효과 : 단일사례연구 (Effects of Active Oral Play and Ayres Sensory Integration (ASI®) for Child With Oral Defensiveness: Single Subject Research)

  • 성가영;최정실;정혜림
    • 대한감각통합치료학회지
    • /
    • 제17권3호
    • /
    • pp.1-13
    • /
    • 2019
  • 목적 : 본 연구는 능동적 구강놀이 병행한 Ayres Sensory Integration®(ASI®) 적용이 아동의 구강 민감도와 섭식행동의 문제에 미치는 영향에 대해 알아보고자 하였다. 연구방법 : 발달지연으로 진단받은 만 3세 6개월의 남자 아동을 대상으로 2018년 8월부터 2018년 9월까지 능동적 구강놀이 병행한 Ayres Sensory Integration®(ASI®)를 실시하였다. 실험설계는 단일사례연구(single-subject design) 중 ABA'설계를 사용하였고 15회기의 중재를 시행하였다. 중재기간 동안 아동의 구강민감도 변화를 측정하기 위해 임상 구강민감도 측정(Measuring Oral Sensitivity in Practice)을 실시하였다. 구강감각처리 어려움으로 섭식활동에 영향을 주는 행동은 한국형 섭취 행동 검사(Korean Children's Eating Behavior Inventory; K-CEBI), 식품 섭취 빈도 체크리스트를 중재 전후로 실시하였다. 결과 : 능동적 구강놀이와 ASI 중재기간 동안 임상 구강민감도와 섭취행동의 문제는 감소하였고 편식행동에는 변화가 없었다. 결론 : 능동적 구강놀이 병행한 ASI 중재는 아동의 구강민감도와 섭취행동의 문제를 감소하는데 긍정적인 효과가 있었다.

SS41강의 F.E.M.복합조직강에서 노치변화가 부식피로파괴에 미치는 영향 (Influence of Notch Change on Corrosion Fatigue Fracture in F.E.M. Dual phase Steel of SS41 Steel)

  • 도영민;이규천
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.44-50
    • /
    • 2001
  • The rotated bending fatigue test was conducted in air md in 3.5% NaCl salt solution to investigate the fatigue fracture behaviour of raw material and F.E.M dual phase steel made from raw material(SS41) by a suitable heat treatment. This study has compared the initial microcrack creation of material by tensile test with that by fatigue test. And the rotated bending test of cantilever type under the condition of 3.5% NaCl salt solution and air has investigated the corrosion fatigue fracture behaviour with the variation of stress concentration factor determined by each of notch shapes. The initial microcrack have been developed in fragile grainboundary with general corrosion occurring in raw material : in the pits built up by corrosion in F.E.M. dual phase steel because pits bring out stress concentration. It is small that the degree of decrease in corrosion fatigue life for F.E.M. dual phase steel compared with raw material because the notch sensitivity of F.E.M. dual phase steel is lower than raw material in reason of characteristics with two-phase construction.

  • PDF

UNCERTAINTY AND SENSITIVITY ANALYSIS OF TMI-2 ACCIDENT SCENARIO USING SIMULATION BASED TECHNIQUES

  • Rao, R. Srinivasa;Kumar, Abhay;Gupta, S.K.;Lele, H.G.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.807-816
    • /
    • 2012
  • The Three Mile Island Unit 2 (TMI-2) accident has been studied extensively, as part of both post-accident technical assessment and follow-up computer code calculations. The models used in computer codes for severe accidents have improved significantly over the years due to better understanding. It was decided to reanalyze the severe accident scenario using current state of the art codes and methodologies. This reanalysis was adopted as a part of the joint standard problem exercise for the Atomic Energy Regulatory Board (AERB) - United States Regulatory Commission (USNRC) bilateral safety meet. The accident scenario was divided into four phases for analysis viz., Phase 1 covers from the accident initiation to the shutdown of the last Reactor Coolant Pumps (RCPs) (0 to 100 min), Phase 2 covers initial fuel heat up and core degradation (100 to 174 min), Phase 3 is the period of recovery of the core water level by operating the reactor coolant pump, and the core reheat that followed (174 to 200 min) and Phase 4 covers refilling of the core by high pressure injection (200 to 300 min). The base case analysis was carried out for all four phases. The majority of the predicted parameters are in good agreement with the observed data. However, some parameters have significant deviations compared to the observed data. These discrepancies have arisen from uncertainties in boundary conditions, such as makeup flow, flow during the RCP 2B transient (Phase 3), models used in the code, the adopted nodalisation schemes, etc. In view of this, uncertainty and sensitivity analyses are carried out using simulation based techniques. The paper deals with uncertainty and sensitivity analyses carried out for the first three phases of the accident scenario.

A PARAMETRIC SENSITIVITY STUDY OF GDI SPRAY CHARACTERISTICS USING A 3-D TRANSIENT MODEL

  • Comer, M.A.;Bowen, P.J.;Sapsford, S.M.;Kwon, S.I.
    • International Journal of Automotive Technology
    • /
    • 제5권3호
    • /
    • pp.145-153
    • /
    • 2004
  • Potential fuel economy improvements and environmental legislation have renewed interest in Gasoline Direct Injection (GDI) engines. Computational models of fuel injection and mixing processes pre-ignition are being developed for engine optimisation. These highly transient thermofluid models require verification against temporally and spatially resolved data-sets. The authors have previously established the capability of PDA to provide suitable temporally and spatially resolved spray characteristics such as mean droplet size, velocity components and qualitative mass distribution. This paper utilises this data-set to assess the predictive capability of a numerical model for GDI spray prediction. After a brief description of the two-phase model and discretisation sensitivity, the influence of initial spray conditions is discussed. A minimum of 5 initial global spray characteristics are required to model the downstream spray characteristics adequately under isothermal, atmospheric conditions. Verification of predicted transient spray characteristics such as the hollow-cone, cone collapse, head vortex, stratification and penetration are discussed, and further improvements to modelling GDI sprays proposed.

충격력을 받는 구형 쉘의 혼돈거동 해석 (Chaotic Response of a Spherical Shell to Impulsive Loading)

  • 이재영;강영철
    • 전산구조공학
    • /
    • 제10권3호
    • /
    • pp.167-174
    • /
    • 1997
  • 계가 혼돈거동을 나타낼 경우에는 변수들의 미소변화에 의해서도 계가 전혀 다른 거동을 나타낼 수 있기 때문에 비선형계의 설계 및 해석시에는 이를 고려해야 한다. 따라서 본 연구에서는 구형 쉘의 중앙에 충격하중이 수직방향으로 작용하는 경우, 쉘의 기하학적 비선형성과 재료적 비선형성으로부터 기인되는 혼돈거동을 해석하였다. 쉘의 탄소성거동을 유한요소법을 이용하여 구한 후 계의 거동을 변위-시간이력, 프앙카레 맵, phase diagram등의 표준적인 방법들을 이용하여 쉘의 혼돈거동을 규명하였다. 해석결과, 계는 혼돈거동을 나타내었으나 탄소성보의 경우와는 달리 초기조건의 미소변화에 대한 극도의 민감도는 나타나지 않았으며 시간에 대한 쉘의 거동특성도 크게 변하지 않았다. 프앙카레 맵은 한정된 영역에 결쳐서 점들이 분포되었기 때문에 계의 거동이 혼돈거동임을 보여 주고 있지만 혼돈계의 프앙카레 맵에서 나타나는 기하학적 구조는 나타나지 않았다. 에너지선도를 이용하여 쉘이 하중의 작용방향 또는 반대방향으로 불규칙적으로 snap-through되는 원인을 규명하였다.

  • PDF

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

COMMOM MODE COMPENSATION IN FIBER OPTIC INTERFEROMETRIC SENSOR WITH LESS COHERENT LIGHT

  • Park, Kyung-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1108-1111
    • /
    • 1990
  • Sorce noise effect in 1.5 Mach-Zehnder (MZ) interferometer is analyzed. It is shown numerically that with fine adjustments to the feedback gain and initial phase biases, the operating point of the interferometer to achives common mode compensation can be made to lie in a region where the measurand sensitivity is greater than it would be in a conventional Mach-Zehnder interferometer even if the source is less coherent.

  • PDF