• Title/Summary/Keyword: Initial Operating Point

Search Result 71, Processing Time 0.035 seconds

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.

Recovery of ammonium lactates from simulated fermentation broth by desalting electrodialysis (탈염전기투석에 의한 모사발효액으로부터의 암모늄 락테이트의 회수)

  • Han Taehee;Kim Hyun Han;Chang Yong Keun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.11a
    • /
    • pp.263-266
    • /
    • 2004
  • An experimental study was carried out on the recovery of ammonium lactate from simulated fermentation brothby desalting electrodialysis (DSED). All experiments, using AM-1 and CM-1 membranes, were operated in a constant current and a subsequent constant-voltage mode, and the switching point was determined based on the previous results. The effects of operating conditions such as operating current, initial feed concentration, and initial feed pH were investigated. Increased operating current resulted in a decreased operating time but an increased energy consumption per unit amount of ammonium lactate recovered. As the initial feed concentration was increased, the operating time increased while energy consumption decreased. The operating time and energy consumption slightly decreased as the initial feed pH was increased up to 6.0. However, no significant influences on the recovery of ammonium lactate were observed over 6.0. The rejections of acetate, glucose, and proteins were $10\%,\;93\%,\;and\;98\%$, respectively. Sulfate was not rejected at all.

  • PDF

On the Structure of A Matrix for Dynamic Stability Analysis of One Machine to the Infinite Bus (발전기-무한모선계통의 동태안정도 해석시 A행렬의 구조)

  • Kwon, Sae-Hyuk;Song, Kil-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.211-215
    • /
    • 1989
  • The structure of A matrix of one machine connected to the infinite bus is described for a full model. The A matrix can be partitioned to submatrices which depend on the initial operating point and do not depend on it. When the dynamic properties for several different operating points are desired, those submatrices can be obtained through simple column operations. Furthermore, the elements of A matrix car be directly calculated from the manufacturer's data. RMS quantities of the state variables for the initial operating point are used. This approach can save the labor for calculating the elements of A matrix for the dynamic stability analysis.

  • PDF

On the Structure of A Matrix for Dynamic Stability Analysis of One Machine to the Infinite Bus (발전기 무한모선계통의 동태안정도 해석시 A행렬의 구조)

  • 권세혁;송길영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 1990
  • The structure of A matrix of one machine connected to the infinite bus is described for a full model. The A matrix can be partitioned to submatrices which depend on the initial operating point and do not depend on it. When the dynamic properties for several different operating points are desired, those submatrices can be obtained through simple column operation. Furthermore, the elements of A matrix can be directly calculated from the manufacturer's data. RMS quantities of the state variables for the initial operating point are used. This approach can save the labor for calculating the elements of A matrix for the dynamic stability analysis.

  • PDF

Large Eddy Simulation on the Drag and Static Pressure Acting on the Blade Surface of Three-Dimensional Small-Size Axial Fan with Different Operating Loads (운전부하에 따른 3차원 소형축류홴 날개표면에 작용하는 정압과 항력에 대한 대규모와 모사)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 2017
  • The large-eddy simulation(LES) was carried out to evaluate the drag and static pressure acting on the blade surface of a small-size axial fan(SSAF) under the condition of unsteady-state, incompressible fluid and three-dimensional coordination. The axial component of drag coefficient increases with the increase of operating load, but the radial components have negligible sizes regardless of operating loads. Otherwise, the static pressures acting on the blade surfaces of SSAF show different distributions around the operating point of D equivalent to the stall. Also, with the increase of operating load, the static pressures acting on the pressure and suction surfaces of blade concentrate at the tips and leading-edges as a whole.

Transient Analysis of a Simple Cycle Gas Turbine Engine

  • Kim, SooYong;Soudarev, B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.22-29
    • /
    • 2000
  • A method to simulate the gas turbine transient behavior is developed. The basic principles of the method and main input data required are described. Calculation results are presented in terms of whole operating regime of the engine. The influence of initial parameters such as starting engine power, moment of inertia of the rotor, fuel schedule on performance characteristics of gas turbine during transient operation is shown. In addition, the effect of bleeding air on transient behavior is also considered. For validation of the developed computer code, a comparative analysis with experimental data obtained from a heavy duty gas turbine is made. Calculation results agree well with the experimental data for the range of operating regime studied and proved applicability of the developed technique to initial design stage of control system.

  • PDF

Adjacent to the Highway Intersection, According to the Disaster, the Optimal Operating (고속도로 재난/재해에 따른 인접교차로 최적 운영방안)

  • Kang, Jin-Woong;Kwon, Young-Hyuk;Lee, Mun-Young;Choi, Jae-Young;Kum, Ki-Jung
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.87-96
    • /
    • 2012
  • This research overcomes limit of prevention of disasters connection manual that was stopping in existing administrative formality presentation, and allowed purpose in substantial prevention of disasters countermeasure presentation through powerful engineering access. Did operation plan manual Tuesday in contiguity crossing that can reduce confusion by vehicleses that detour by contiguity IC of disaster point to do unusualness ashes in freeway section for this and solve jam-up phenomenon that occur by processing way insufficiency for roundabout way vehicles when happen. Metropolitan areas to target type classification in the highway along the highway adjacent to the intersection at Main Line Blocking optimum operating point analysis and an analysis of countermeasures in case of disaster, the lower the road entering the highway depending on the type of operating at the intersection were different. Depending on the results of analysis, while each point of a disaster, according to the characteristics of geometric conditions, traffic conditions, identify and determine the operating room and the adjacent intersection of media, and building systems to promote the driver if the quick initial response from the impending disaster situations and the safety of drivers can be considered secure.

COMMOM MODE COMPENSATION IN FIBER OPTIC INTERFEROMETRIC SENSOR WITH LESS COHERENT LIGHT

  • Park, Kyung-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1108-1111
    • /
    • 1990
  • Sorce noise effect in 1.5 Mach-Zehnder (MZ) interferometer is analyzed. It is shown numerically that with fine adjustments to the feedback gain and initial phase biases, the operating point of the interferometer to achives common mode compensation can be made to lie in a region where the measurand sensitivity is greater than it would be in a conventional Mach-Zehnder interferometer even if the source is less coherent.

  • PDF

Feasibility of Laparoscopic Surgery for Intussusception in Pediatric Patients and Risk of Bowel Resection

  • Song, Eun Ju;Nam, So Hyun
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Purpose: Intussusception is a common cause of intestinal obstruction in children. While most patients can be treated by enema reduction, about 20% require surgery. We investigated the usefulness and feasibility of laparoscopic surgery and the intraoperative risk of bowel resection. Methods: We retrospectively reviewed pediatric patients who underwent surgery for intussusception from 2010 to 2017. We collected data for age, gender, body weight, associated symptoms, duration of symptoms, white blood cell count, operating time, and postoperative complications. Results: Of 155 patients, 37 (23.8%) underwent surgery due to enema reduction failure in 29 (78.3%), recurrence in 6 (16.3%), a suspicious lead point in 1, and suspicious ischemic change observed on ultrasonography in 1. The mean age was $26.8{\pm}18.9$ months (range, 3.5~76.7 months), and the mean body weight was $12.9{\pm}3.9kg$ (range, 5.4~22.2 kg). Laparoscopic surgery was successful in 29 patients (78.4%), and 7 (18.9%) needed bowel resection and anastomosis. The mean operating time was $56.7{\pm}32.8min$. A lead point was found in 3 patients in the bowel resection group (p=0.005); in addition, the operating time and hospital stay were longer in this group. There were no intra- or postoperative complications. Conclusion: Laparoscopic surgery was successful in 78.4% of the patients with a short hospital stay and early oral intake. The only predictive factor for bowel resection was the presence of a lead point. Laparoscopic surgery may be an optimal treatment intervention for children with intussusception, except for those who show initial peritonitis.

Security Constrained Optimal Power Flow by Hybrid Algorithms (하이브리드 알고리즘을 응용하여 안전도제약을 만족시키는 최적전력조류)

  • Kim, Gyu-Ho;Lee, Sang-Bong;Lee, Jae-Gyu;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.305-311
    • /
    • 2000
  • This paper presents a hybrid algorithm for solving optimal power flow(OPF) in order to enhance a systems capability to cope with outages, which is based on combined application of evolutionary computation and local search method. The efficient algorithm combining main advantages of two methods is as follows : Firstly, evolutionary computation is used to perform global exploitation among a population. This gives a good initial point of conventional method. Then, local methods are used to perform local exploitation. The hybrid approach often outperforms either method operating alone and reduces the total computation time. The objective function of the security constrained OPF is the minimization of generation fuel costs and real power losses. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). In OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The method proposed is applied to IEEE 30 buses system to show its effectiveness.

  • PDF