• Title/Summary/Keyword: Initial Observation Time

Search Result 158, Processing Time 0.035 seconds

The Gender Observation Time Characteristics from Sight Fixation and the Leap of Pupil Index (시선의 고정과 도약 동공지표에 나타난 성별 주시시간 특성)

  • Lee, Jeong Ho;Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • This research is to analyze the change of pupil size in gender through the eye-tracking experiment in large complex cultural space. It is meaningful that figured out the common characteristics and differences from gender observation characteristics. Through this research, the analyzed results of the observation time measurement that appeared from the fixation and saccades pupil indicator able to define as follows. Firstly, it was suggested that there were differences between each gender and participants through extract pupil size that can be the standard examples for the case from male and female and the process of extracting the relative pupil size change on the hourly range. From the specific time range, it was possible to indicate bending characteristics and reversal phenomena of Fixation and Saccades. Second, the result was found equally from both male and female group that the rapid increment of pupil size at initial time range immediately after the eye-tracking experiment has been initiated. This can be considered to actively accepting the stress given by the subject through the extended pupil after 10 seconds that compare to indicated very low pupil size between 0 to 10 seconds after starting the experiment. Third, meanwhile 0 to 10 seconds after initial observation are the time of sudden change in the pupil size, therefore these time range data cannot be regarded as observed in the appropriate condition. Thus, it able to define the highest times of emotional processing for male as 10 to 80 seconds, and for female as 10 to 70 seconds. There was no definition of the time range data for observation experiment from previous research, this data can be considered to stable time to observation through the pupil extension. Therefore, it is possible to set suitable time of observation experiment to be around 70 to 80 seconds exclude initial experiment time.

A Study on Initial Cell Search Parameters in UMTS Terminal Modem (UMTS 단말기 모뎀의 초기 셀 탐색 파라미터의 영향에 대한 연구)

  • 류동렬;김용석;옥광만;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5A
    • /
    • pp.267-275
    • /
    • 2003
  • In UMTS terminal modem uses 3 step search procedure for initial cell search, which comprises 1) slot synchronization, 2) code group identification and frame synchronization, and 3) scrambling-code identification. The performance of initial cell search procedure depends on search parameters like observation time and threshold. The purpose of this paper is to get the optimal observation time and threshold of each step for minimum mean acquisition time. In this paper we induce mean detection time of each step and mean acquisition timefrom the model of 3 step search procedure using state diagram. Also we propose initial cell search algorithm which utilize window search method against initial oscillator error, and select an appropriate observation time and threshold of each step by the analysis of simulation and induced result. It is shown that the mean acquisition time in multipath fading channel can be shorter than 500ms by using the determined observation time and threshold of each step.

Two-Site Optical Observation and Initial Orbit Determination for Geostationary Earth Orbit Satellites

  • Choi, Jin;Choi, Young-Jun;Yim, Hong-Suh;Jo, Jung-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.337-343
    • /
    • 2010
  • Optical observation system provides angle-only measurement for orbit determination of space object. Range measurement can be directly acquired using laser ranging or tone ranging system. Initial orbit determination (IOD) by using angle- only data set shows discrepancy according to the measurement time interval. To solve this problem, range measurement data should be added for IOD. In this study, two-site optical observation was used to derive the range information. We have observed nine geostationary earth orbit satellites by using two-site optical observation system. The determination result of the range shows the accuracy over 99.5% compared to the results from the satellite tool kit simulation. And we confirmed that the orbit determination by the Herrick-Gibbs method with the range information obtained from the two-site observation is more accurate than the orbit determination by Gauss method with the one-site observation. For more accurate two-site optical observation, a baseline should satisfy an optimal condition of length and more precise observation system needed.

A Study on the Strategies of the Positioning of a Satellite on Observed Images by the Astronomical Telescope and the Observation and Initial Orbit Determination of Unidentified Space Objects

  • Choi, Jin;Jo, Jung-Hyun;Choi, Young-Jun;Cho, Gi-In;Kim, Jae-Hyuk;Bae, Young-Ho;Yim, Hong-Suh;Moon, Hong-Kyu;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.333-344
    • /
    • 2011
  • An optical tracking system has advantages for observing geostationary earth orbit (GEO) satellites relatively over other types of observation system. Regular surveying for unidentified space objects with the optical tracking system can be an early warning tool for the safety of five Korean active GEO satellites. Two strategies of positioning on the observed image of Communication, Ocean and Meteorological Satellite 1 are tested and compared. Photometric method has a half root mean square error against streak method. Also eccentricity method for initial orbit determination (IOD) is tested with simulation data and real observation data. Under 10 minutes observation time interval, eccentricity method shows relatively better IOD results than the other time interval. For follow-up observation of unidentified space objects, at least two consecutive observations are needed in 5 minutes to determine orbit for geosynchronous orbit space objects.

Orbit Determination Using Angle-Only Data for MEO & GEO Satellite and Obsolete (중.고궤도 인공위성 및 폐기위성의 광학관측을 이용한 궤도 결정)

  • Choi, Jin;Kim, Bang-Yeop;Yim, Hong-Suh;Chang, Heon-Young;Yoon, Joh-Na;Kim, Myung-Jin;Hwang, Ok-Jun
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.111-126
    • /
    • 2009
  • We used an optical observation system with a 0.6m wide-field telescope and 5 computers system in KASI (Korean Astronomy and Space Science Institute) for satellite optical observation. Optical data have errors that are caused by targeting, expose start time and end-point determination. Gauss method for initial orbit determination was tested using angle-only data simulated by KODAS. And suitable time span is confirmed for result which has minimum errors. Initial orbit determination results are proved that optical observation system in KASI is possible satellite tracking for a short period. And also through differential correction, initial orbit determination results are improved.

Research on the Change in Index of Pupil in the Initial Observation on Large Space of Library (공간의 초기 주시과정에 나타난 동공지표의 크기변화에 관한 연구)

  • Kim, Jong-Ha
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.15-28
    • /
    • 2018
  • The purpose of this study was to conduct eye-tracking experiments to target large spaces and to analyze the characteristics of pupil gaze by gender. By analyzing the change of pupil size in the eye-tracking experiment, we suggest a template for objective and scientific analyses of gender observation data. Additionally, based on the difference between gender and time to pupil size change, we noted the characteristic of time that gather the visual perception data information and showed that females attend to interesting elements of visual information one to two seconds slower than males. In the initial "$1sec{\rightarrow}2sec$", the pupil size has been increased in leap condition of male and in fixed condition of female. In addition, if condition limits to fixed observation to view the change rates on gender then the pupil size of female was larger than male before 9 seconds, while male's pupil size was larger after 9 seconds. This indicates that females obtain visual information through a relatively larger pupil size during the first 1-8 seconds after stimulus presentation, while males acquire it between 10-15 seconds after input. However, based on the result that the pupil size of female was larger than male on the change of observation time, the pupil size movement on female was energized to watch more interest element after a certain period of time.

Precise Orbit Determination Based on the Unscented Transform for Optical Observations

  • Hwang, Hyewon;Lee, Eunji;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.249-264
    • /
    • 2019
  • In this study, the precise orbit determination (POD) software is developed for optical observation. To improve the performance of the estimation algorithm, a nonlinear batch filter, based on the unscented transform (UT) that overcomes the disadvantages of the least-squares (LS) batch filter, is utilized. The LS and UT batch filter algorithms are verified through numerical simulation analysis using artificial optical measurements. We use the real optical observation data of a low Earth orbit (LEO) satellite, Cryosat-2, observed from optical wide-field patrol network (OWL-Net), to verify the performance of the POD software developed. The effects of light travel time, annual aberration, and diurnal aberration are considered as error models to correct OWL-Net data. As a result of POD, measurement residual and estimated state vector of the LS batch filter converge to the local minimum when the initial orbit error is large or the initial covariance matrix is smaller than the initial error level. However, UT batch filter converges to the global minimum, irrespective of the initial orbit error and the initial covariance matrix.

A Method of Tracking Object using Particle Filter and Adaptive Observation Model

  • Kim, Hyoyeon;Kim, Kisang;Choi, Hyung-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, we propose an efficient method that is tracking an object in real time using particle filter and adaptive observation model. When tracking object, it happens object shape variation by camera or object movement in variety environments. The traditional method has an error of tracking from these variation, because it has fixed observation model about the selected object by the user in the initial frame. In order to overcome these problems, we propose a method that updates the observation model by calculating the similarity between the used observation model and the eight-way of edge model from the current position. If the similarity is higher than the threshold value, tracking the object using updated observation model to reset observation model. On the contrary to this, the algorithm which consists of a process is to maintain the used observation model. Finally, this paper demonstrates the performance of the stable tracking through comparison with the traditional method by using a number of experimental data.

Features of Attention to Space Structure of Spacial Composition in Women's Shop - Targeting the Circulation Line of Department Store - (여성의류 매장 공간의 구도에 나타난 공간구성의 주의집중 특성 - 백화점 매장의 순회동선을 대상으로 -)

  • Choi, Gae-Young;Son, Kwang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.2
    • /
    • pp.3-12
    • /
    • 2017
  • This study has analyzed the features of attention to spacial composition seen in "Seeing ${\leftrightarrow}$ Seen" Correlation of continuous move in the space. The eye-tracking was employed for collecting the data of attention features to the space so that the correlation between visual perception and space could be estimated through the attention features to the difference between spacial composition and display. First, it was confirmed that the attention features varied according to the structure of shops and the exposure degree of selling space, which revealed that, while causing the customers' less attention to both sides of shops, the vanishing-point structure characteristically made their eyes focused on the central part. Second, their initial observation activities were found to be active at the height of their eyes. Third, 10 images were selected as objects for continuous experiment. There was a concern that the central part of each image would be paid intense attention to during the initial observation, but only two of those were found to be so. Fourth, there had been a study result of eye-tracking experiment that the attention had been concentrated on the central part of the image first seen. This study, however, revealed that such phenomenon is limited to the first image. Accordingly, it is necessary to draw up such method for ensuring reliability in order to use the data acquired from any eye-tracking experiment as exclusion of the initial attention time to the first image or of unemployment of the initial image-experiment to analysis.

Comparative Study of Wound Healing in Porcine Stomach with $CO_2$ Laser and Scalpel Incisions (돼지에서 $CO_2$ laser와 외과용 수술도를 이용한 위 절개 시 창상 치유 평가)

  • Byun, Hong Seob;Lee, Jae Yeon;Kim, Myung Cheol
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • We compared wound healing with $CO_2$ laser incision and scalpel incision by measuring the extent of bleeding, the ease of incision, time, degrees of adhesion and histological observation in pig's stomach. Eight healthy pigs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater curvature and lesser curvature were made with scalpel and 2 mm spot diameter $CO_2$ laser (8W, continuous wave) in eight pigs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 7 and 14 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the two groups. The $CO_2$ laser provided better hemostasis (p < 0.01) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_2$ laser group (p < 0.01). There was no considerable difference between the two groups in histological observation.