• Title/Summary/Keyword: Infusion pumps

Search Result 26, Processing Time 0.026 seconds

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

Evaluation of Clinical Alarms and Alarm Management in Intensive Care Units (중환자실에서 사용되는 의료장비의 경보음 발생과 관리 현황)

  • Jeong, Yu Jin;Kim, Hyunjung
    • Journal of Korean Biological Nursing Science
    • /
    • v.20 no.4
    • /
    • pp.228-235
    • /
    • 2018
  • Purpose: This study aimed to investigate the clinical alarm occurrence and management of nurses toward clinical alarms in the intensive care unit (ICU). Methods: This observational study was conducted with 40 patients and nurses cases in two ICUs of a university hospital. This study divided 24 hours into the unit of an hour and conducted two times of direct observation per unit hour for 48 hours targeting the medical devices applied to 40 patients. Data were analyzed using IBM SPSS Statistics 23. Results: On average, 3.8 units of medical devices were applied for each patient and the ranges of alarm settings were wide. During 48 hours, 184 cases of clinical alarm were occurred by four types of medical devices including physiological monitors, mechanical ventilators, infusion pumps, and continuous renal replacement therapy. Among them, false alarm was 110 cases (59.8%). As for the alarm management by ICU nurses, two-minute alarm mute took up most at 38.0% (70 cases), and no response was second most at 32.6% (60 cases). When valid alarm sounded, nurses showed no response at 43.2%. Conclusion: The findings suggest that a standard protocol for alarm management should be developed for Korean ICU settings. Based on the protocol, continuous training and education should be provided to nurses for appropriate alarm management.

Histone deacetylase inhibition attenuates hepatic steatosis in rats with experimental Cushing's syndrome

  • Kim, Mina;Lee, Hae-Ahm;Cho, Hyun-Min;Kang, Seol-Hee;Lee, Eunjo;Kim, In Kyeom
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.1
    • /
    • pp.23-33
    • /
    • 2018
  • Cushing's syndrome (CS) is a collection of symptoms caused by prolonged exposure to excess cortisol. Chronically elevated glucocorticoid (GC) levels contribute to hepatic steatosis. We hypothesized that histone deacetylase inhibitors (HDACi) could attenuate hepatic steatosis through glucocorticoid receptor (GR) acetylation in experimental CS. To induce CS, we administered adrenocorticotropic hormone (ACTH; 40 ng/kg/day) to Sprague-Dawley rats by subcutaneous infusion with osmotic mini-pumps. We administered the HDACi, sodium valproate (VPA; 0.71% w/v), in the drinking water. Treatment with the HDACi decreased steatosis and the expression of lipogenic genes in the livers of CS rats. The enrichment of GR at the promoters of the lipogenic genes, such as acetyl-CoA carboxylase (Acc), fatty acid synthase (Fasn), and sterol regulatory element binding protein 1c (Srebp1c), was markedly decreased by VPA. Pan-HDACi and an HDAC class I-specific inhibitor, but not an HDAC class II a-specific inhibitor, attenuated dexamethasone (DEX)-induced lipogenesis in HepG2 cells. The transcriptional activity of Fasn was decreased by pretreatment with VPA. In addition, pretreatment with VPA decreased DEX-induced binding of GR to the glucocorticoid response element (GRE). Treatment with VPA increased the acetylation of GR in ACTH-infused rats and DEX-induced HepG2 cells. Taken together, these results indicate that HDAC inhibition attenuates hepatic steatosis through GR acetylation in experimental CS.

Decreased Diethylnitrosamine-induced Liver Preneoplastic Lesions by Estradiol-3-benzoate Treatment

  • Kang, Jin-Seok;Park, Ki-Dae;Ahn, Byeong-Woo;Han, Beom-Seok
    • Toxicological Research
    • /
    • v.27 no.4
    • /
    • pp.247-251
    • /
    • 2011
  • To clarify whether inhibitory effect of estrogen on liver tumor is associated with cell proliferation, we investigated its role in diethylnitrosamine (DEN)-induced rat preneoplastic lesions, with time sequenced manners. F344 male rats (n = 90) were divided into three groups at 5 weeks of age. The mini-osmotic pumps providing a continuous infusion of DEN was implanted into the abdominal cavity of each animal in group 1, 2 and 3 at 6 weeks of age. To see the effect of estrogen, pellet containing 1 or 10 ${\mu}g$ of estradiol-3-benzoate (EB) was implanted subcutaneously in the animals of groups 2 or 3, respectively, one week prior to DEN treatment. Ten animals of each group were euthanized at 10, 14 and 18 weeks after DEN treatment. Liver tissues at each time point were fixed in 10% phosphate-buffered formalin and were processed and embedded in paraffin and 5 ${\mu}g$ sections mounted on a silanized slide. Glutathione S-transferase placental form (GST-P) positive foci and 5-bromo-2-deoxyuridine (BrdU) labeling cells were detected at each time point. Area of GST-P positive foci in DEN+EB 1 or 10 ${\mu}g$ group was significantly decreased compared to DEN alone at 14 weeks (p < 0.01 or p < 0.05, respectively) an at 18 weeks (p < 0.05 or p < 0.01, respectively). BrdU index in DEN+EB 1 or 10 ${\mu}g$ groups was significantly decreased compared to DEN alone at 14 weeks and at 18 weeks (p < 0.01). Taken together, we conclude that EB treatment decrease the DEN-induced liver preneoplastic lesions and this may be associated with decrease of cellular proliferation.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

Effect of renin inhibition on an experimental glomerulonephritis - a preliminary report (레닌 억제제가 실험적 사구체 콩팥염에 미치는 효과 - 예비 보고)

  • Kang, Ju-Hyung;Heo, Jae-Kyung;Lee, Young-Sook;Han, Ji-Young;Ha, Il-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.8
    • /
    • pp.938-943
    • /
    • 2009
  • Purpose : We performed this study in order to investigate the effect of direct renin inhibition on an experimental animal model with nephrotoxic serum nephritis and tried to give useful information for clinical research and renin inhibitor treatment. Methods : Thirty BALB/c 6-week-old male mice were divided into 4 groups: control group (CO, n=5), control-treatment group with aliskiren (CT, n=5), disease group (DO, n=10), and disease treatment group with aliskiren (DT, n=10). Nephritis was induced by an intravenous injection of 0.25 mg/g weight of rabbit anti-GBM immunoglobulin G. Model 2002 Alzet mini-osmotic pumps (Durect Corp.) for aliskiren infusion were implanted into CT and DT. Each group strain was sacrificed serially one at a time on day 14. We estimated the protein-creatinine ratio in 12-hour-collected urine (UP/Cr) and measured the mesangial matrix score in the PAS-stained kidney of each strain. Results : One strain at CT and DT died on day 6 and 7, respectively. Each group strain was sacrificed serially at a time on day 10 because DO were seriously ill. The UP/Cr of each group is as follows: CO, $31.24{\pm}6.54mg/mg$, CT, $23.38{\pm}13.60mg/mg$, DO, $112.72{\pm}10.97mg/mg$, DT $114.07{\pm}32.30mg/mg$. There was no significant difference between DO and DT. The mesangial matrix score of each group was CO, $0.23{\pm}0.10$; CT, $0.13{\pm}0.03$; DO, $1.90{\pm}0.48$; and DT, $1.28{\pm}0.41$, respectively, and there was a significant difference between DO and DT in the extent of mesangial matrix expansion (P=0.008). Conclusion : We found that renin inhibition was able to suppress the mesangial matrix expansion in experimental mice with acute nephritis, although there were no significant differences in UP/Cr.