• Title/Summary/Keyword: Infusion pumps

Search Result 26, Processing Time 0.03 seconds

Smart syringe pumps for drug infusion during dental intravenous sedation

  • Seo, Kwang-Suk;Lee, Kiyoung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intravenous sedatives. Administration of these sedatives via infusion by using a syringe pump is more effective and successful than infusing them as a bolus. However, during intravenous infusion of sedatives or opioids using a syringe pump, fatal accidents may occur due to the clinician's carelessness. To prevent such risks, smart syringe pumps have been introduced clinically. They allow clinicians to perform effective sedation by using a computer to control the dose of the drug being infused. To ensure patient safety, various alarm features along with a drug library, which provides drug information and prevents excessive infusion by limiting the dose, have been added to smart pumps. In addition, programmed infusion systems and target-controlled infusion systems have also been developed to enable effective administration of sedatives. Patient-controlled infusion, which allows a patient to control his/her level of sedation through self-infusion, has also been developed. Safer and more successful sedation may be achieved by fully utilizing these new features of the smart pump.

Design of Remote Infusion Pump Monitoring System Using Wireless Network and RFID Technology (무선 네트워크와 RFID 기술을 이용한 원격 Infusion Pump 모니터링 시스템 설계)

  • Lee, Seo-Joon;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.159-167
    • /
    • 2013
  • Development of infusion pumps enabled injecting medical substances continuously and automatically to patients in hospitals. However, in cases when patients encountered emergent situations when moving to other areas, no clear measures were taken. The problem is that even the lightest error in injecting medical substances could be critical to the patient. That is why we proposes a remote infusion monitoring system using wireless network and RFID technology in this paper. When a problem occurs in the infusion pump, the medical personnel are informed of their patients' emergent situation and location information via wireless network so not only can they swiftly and accurately provide medical services but also can prevent safety accidents due to infusion pumps.

Efficacy evaluation of syringe pump developed for continuous drug infusion

  • Jung, Bongsu;Seo, Kwang-Suk;Kwon, Suk Jin;Lee, Kiyoung;Hong, Suyong;Seo, Hyounsoon;Kim, Gi-Young;Park, Geun-Mook;Jeong, Juhee;Seo, Soowon
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.4
    • /
    • pp.303-307
    • /
    • 2016
  • Background: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. Methods: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. Results: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. Conclusions: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

Safety and efficacy of target controlled infusion administration of propofol and remifentanil for moderate sedation in non-hospital dental practice

  • Douglas Lobb;Masoud MiriMoghaddam;Don Macalister;David Chrisp;Graham Shaw;Hollis Lai
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.19-28
    • /
    • 2023
  • Background: Fearful and anxious patients who find dental treatment intolerable without sedative and analgesic support may benefit from moderate sedation. Target controlled infusion (TCI) pumps are superior to bolus injection in maintaining low plasma and effect-site concentration variability, resulting in stable, steady-state drug concentrations. We evaluated the safety and efficacy of moderate sedation with remifentanil and propofol using TCI pumps in non-hospital dental settings. Methods: A prospective chart review was conducted on 101 patients sedated with propofol and remifentanil using TCI pumps. The charts were completed at two oral surgeons and one general dentist's office over 6 months. Hypoxia, hypotension, bradycardia, and over-sedation were considered adverse events and were collected using Tracking and Reporting Outcomes of Procedural Sedation (TROOPS). Furthermore, patient recovery time, sedation length, drug dose, and patient satisfaction questionnaires were used to measure sedation effectiveness. Results: Of the 101 reviewed sedation charts, 54 were of men, and 47 were of women. The mean age of the patients was 40.5 ±18.7 years, and their mean BMI was 25.6 ± 4.4. The patients did not experience hypoxia, bradycardia, and hypotension during the 4694 min of sedation. The average minimum Mean Arterial Pressure (MAP) and heartbeats were 75.1 mmHg and 60.4 bpm, respectively. 98% of patients agreed that the sedation technique met their needs in reducing their anxiety, and 99% agreed that they were satisfied with the sedation 24 hours later. The average sedation time was 46.9 ± 55.6 min, and the average recovery time was 12.4 ± 4.4 min. Remifentanil and propofol had mean initial effect-site concentration doses of 0.96 µ/.ml and 1.0 ng/ml respectively. The overall total amount of drug administered was significantly higher in longer sedation procedures compared to shorter ones, while the infusion rate decreased as the procedural stimulus decreased. Conclusion: According to the results of this study, no patients experienced adverse events during sedation, and all patients were kept at a moderate sedation level for a wide range of sedation times and differing procedures. The results showed that TCI pumps are safe and effective for administering propofol and remifentanil for moderate sedation in dentistry.

Effectiveness of continuous hypertonic saline infusion with an automated infusion pump for decompressive neuroplasty: a randomized clinical trial

  • Lee, Ho-Jin;Lee, Jaewoo;Park, Yeon wook;Gil, Ho Young;Choi, Eunjoo;Nahm, Francis Sahngun;Lee, Pyung Bok
    • The Korean Journal of Pain
    • /
    • v.32 no.3
    • /
    • pp.196-205
    • /
    • 2019
  • Background: Hypertonic saline (HS) injections for decompressive neuroplasty (DN) can cause pain. We assessed whether a continuous infusion of HS through an infusion pump would reduce injection-related pain compared with repeated bolus administrations. Methods: Fifty patients scheduled for DN were randomized to either the bolus injection or the continuous infusion group. After appropriately placing the epidural catheter, 4 mL of 5% NaCl was injected as four boluses of 1 mL each at 15-minute intervals or infused over 1 hour using an infusion pump. The severity of pain induced by HS injection, as measured by the 11-point numerical rating scale (NRS), was the primary outcome. The severity of low back or lower extremity pain, as measured by the 11-point NRS and Oswestry Disability Index (ODI), 3 months following the procedure, was the secondary outcome. Results: Data from 21 patients in the bolus group and 23 in the continuous infusion group were analyzed. No statistically significant difference in injection-related pain was identified between the two groups during the initial HS administration (P = 0.846). However, there was a statistically significant reduction in injection-related pain in the continuous infusion group compared to the bolus injection group from the second assessment onwards (P = 0.001, < 0.001, and < 0.001, respectively). No significant between-group differences in the NRS and ODI scores 3 months post-procedure were noted (P = 0.614 and 0.949, respectively). Conclusions: Our study suggests that administering HS through a continuous infusion is a useful modality for reducing HS injection-related pain during DN.

Propofol Patient-Controlled Sedation Using $Perfusor^{\circledR}$ fm (B. Braun, Germany) Infusion Pump in Dental Patients-Preliminary Study (치과 환자에서의 $Perfusor^{\circledR}$ fm 자가통증조절기를 이용한 Propofol 자가진정조절법)

  • Park, Chang-Joo;Yum, Kwang-Won;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.2 no.2 s.3
    • /
    • pp.97-100
    • /
    • 2002
  • Background: Patient-controlled sedation (PCS) has been blown for a safe and effective sedative method on the same pharmacological concepts of patient-controlled analgesia. Many different kinds of infusion devices have been used but they often have too long nominal infusion rate and lockout time. $Perfuser^{\circledR}$ fm (B. Braun, Germany) is a new PCA device with 999.9 ml/hr nominal infusion rate and minimum 1 min lockout time. In this study, the feasibility of propofol PCS using $Perfuser^{\circledR}$ fm was examined in order to provide a safe satisfactory sedation for dental patients. Methods: Eleven healthy patients presenting for oral surgery were studied. Propofol PCS was performed using $Perfuser^{\circledR}$ fm, which was set to deliver a bolus dose of 5 mg with 999.9 ml/hr nominal infusion rate and 1 min lockout time. Propofol loading dose was randomly assigned to a bolus dose ${\times}$ 0, 2, and 3 (initial bolus). Patients were told to press the bolus button as often as they needed to relieve discomfort. Results: Total infused dose of propofol was mean 1.8 mg/kg/hr and D (Delivery)/A (Attempt) ratio was mean 72.8%. All patients was awake and there were no clinically significant intraoperative side effects during the sedation. Almost all patients were very satisfied with this type of PCS. Conclusion: Propofol PCS using $Perfuser^{\circledR}$ fm infusion pump provided good conscious sedation for dental procedures.

  • PDF

Response of Muscle Protein Synthesis to the Infusion of Insulin-like Growth Factor-I and Fasting in Young Chickens

  • Kita, K.;Shibata, T.;Aman Yaman, M.;Nagao, K.;Okumura, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.12
    • /
    • pp.1760-1764
    • /
    • 2002
  • In order to elucidate the physiological function of circulating IGF-I on muscle protein synthesis in the chicken under malnutritional conditions, we administrated recombinant chicken IGF-I using a osmotic mini pump to fasted young chickens and measured the rate of muscle protein synthesis and plasma metabolite. The pumps delivered IGF-I at the rate of $22{\mu}g/d\{300{\mu}g{\cdot}(kg\;body\;weight{\cdot}d)^{-1}\}$. Fractional rate of protein synthesis in the muscle was measured using a large dose injection of L-[$2,6-^3H$]phenylalanine. Constant infusion of chicken IGF-I did not affect plasma glucose level. Significant interaction between dietary treatment and IGF-I infusion was observed in plasma NEFA and total cholesterol concentrations. When chicks were fasted, IGF-I infusion decreased plasma NEFA and total cholesterol concentrations. On the other hand, IGF-I administration did not affect plasma levels of both metabolites. Fasting reduced plasma triglyceride concentration significantly. IGF-I infusion also decreased the level of plasma triglyceride. Plasma IGF-I concentration of young chickens was halved by fasting for 1 d. IGF-I infusion using an osmotic minipump for 1 d increased plasma IGF-I concentration in fasted chicks to the level of fed chicks. Fasting decreased body weight and the loss of body weight was significantly ameliorated by IGF-I infusion. There was a significant interaction between dietary treatment and IGF-I infusion in the fractional rate of breast muscle protein synthesis. There was no effect of IGF-I infusion on muscle protein synthesis in fed chicks. Muscle protein synthesis reduced by fasting was ameliorated by IGF-I infusion, but did not reach to the level of fed control. Muscle weight of fasted chicks infused with IGF-I was similar to fasted birds without IGF-I infusion, which suggests that muscle protein degradation would be increased by IGF-I infusion as well as protein synthesis in fasted chicks.

The evaluation of implementing smart patient controlled analgesic pump with a different infusion rate for different time duration on postoperative pain management

  • Kim, Saeyoung;Jeon, Younghoon;Lee, Hyeonjun;Lim, Jung A;Park, Sungsik;Kim, Si Oh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.4
    • /
    • pp.289-294
    • /
    • 2016
  • Background: Control of postoperative pain is an important aspect of postoperative patient management. Among the methods of postoperative pain control, patient-controlled analgesia (PCA) has been the most commonly used. This study tested the convenience and safety of a PCA method in which the dose adjusted according to time. Methods: This study included 100 patients who had previously undergone orthognathic surgery, discectomy, or total hip arthroplasty, and wished to control their postoperative pain through PCA. In the test group (n = 50), the rate of infusion was changed over time, while in the control group (n = 50), drugs were administered at a fixed rate. Patients' pain scores on the visual analogue scale, number of rescue analgesic infusions, side effects, and patients' satisfaction with analgesia were compared between the two groups. Results: The patients and controls were matched for age, gender, height, weight, and body mass index. No significant difference in the mount of drug administered was found between the test and control groups at 0-24 h after the operation; however, a significant difference was observed at 24-48 h after the operation between the two groups. No difference was found in the postoperative pain score, number of side effects, and patient satisfaction between the two groups. Conclusions: Patient-controlled anesthesia administered at changing rates of infusion has similar numbers of side effects as infusion performed at a fixed rate; however, the former allows for efficient and safe management of postoperative pain even in small doses.

Quality of Life in Colorectal Cancer Patients at Home 5-Fluorouracil Chemotherapy with Disposable Elastomeric Infusion Pumps (일회용 약물주입기로 가정에서 항암치료 중인 대장암 환자의 삶의 질)

  • Lee, Chung Eun;Kim, Na Young;Park, Me Hee;Lee, Yoon Jung;Kim, Jin Ra;Baek, Min Ju;Kim, Hyo Jin;Byun, Eun Sung;Kil, Yun Kyung;Kim, Heejung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.76-87
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the psychological distress related to quality of life (QoL) of patients with colorectal cancer receiving 5-fluorouracil (5-FU) chemotherapy at home with disposable Elastomeric infusion pumps. Methods: In this study, 179 colorectal outpatients were recruited between September 2019 and January 2021. National Cancer Center Psychological Symptom Inventory scores, general self-efficacy, and the EORTC QLQ-C30 scores were measured. Data were analyzed using Independent t-test, One-way ANOVA with Bonferroni post hoc analysis, and hierarchical multiple linear regression with the SPSS/WIN 26.0 programs. Results: The overall prevalence of psychological distress was 52.0% in colorectal patients. In multiple regression, psychological distress (β=-.20, p=.005), appetite loss (β=-.20, p=.001), chemotherapy cycles (β= .19, p=.002), fatigue (β=-.16, p=.035), physical functioning (β=-.16, p=.024), and emotional functioning (β=-.15, p=.025) were significant factors of QoL, and the final model explained 45.0% of the total variance of QoL. Conclusion: Supporting patients toward decreased psychological distress and increased physical and emotional functioning, especially in the first or second cycle of chemotherapy, could be used to improve their QoL. To consider the thresholds for clinical importance, it is necessary to increase the interpretation of psychological distress in clinical practice and further research.