• 제목/요약/키워드: Infusion Set

검색결과 28건 처리시간 0.025초

Remifentanil-Propofol Sedation as an Ambulatory Anesthesia for Carpal Tunnel Release

  • Lee, Jae-Jun;Hwang, Sung-Mi;Jang, Ji-Su;Lim, So-Young;Heo, Dong-Hwa;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권5호
    • /
    • pp.429-433
    • /
    • 2010
  • Objective : This prospective study evaluated the use of continuous sedation using propofol and remifentanil when carpal tunnel release (CTR) was performed under local anesthesia. Methods : We sedated 60 patients undergoing CTR using local anesthesia with remifentanil at loading and continuous doses of $0.5\;{\mu}g\;kg^{-1}$ and $0.05\;{\mu}g\;kg^{-1}min^{-1}$, respectively, and propofol, using a target controlled infusion (TCI) pump set to a target of $2\;{\mu}g\;mL^{-1}$ (group A), or with the same drug doses except that the continuous remifentanil dose was $0.07\;{\mu}g\;kg^{-1}min^{-1}$ (group B) or $0.1\;{\mu}g\;kg^{-1}min^{-1}$ (group C). Results : In group B, the levels of pain when local anesthetics were administered (p = 0.001), intraoperative pain (p < 0.001) and anxiety (p = 0.001) were significantly lower than those of group A. Furthermore, the incidence of adverse events, including desaturation (p < 0.001) and vomiting (p = 0.043), was significantly lower in group B than in group C. Conclusion : Continuous sedation using an appropriate dose of remifentanil and propofol can be used as safe, efficacious ambulatory anesthesia in cases of CTR under local anesthesia, performed using only 2 mL of local anesthetic, with a high degree of patient satisfaction.

RFI 공정시 적정 수지필름 두께에 관한 연구 (A Study on the Proper Resin Film Thickness in RFI Process)

  • 윤성현;이정완;김정수;김위대;엄문광
    • Composites Research
    • /
    • 제31권1호
    • /
    • pp.23-29
    • /
    • 2018
  • RFI 공정은 수지 점도에 제한이 없어 매우 두꺼운 구조물에도 적용이 가능하다. 수지필름 두께를 설정할 때 수지필름의 두께가 얇은 경우 미함침 구간이 발생하여 기계적 물성이 저하되고, 수지필름 두께가 두꺼운 경우 필요이상의 여분 수지가 발생하게 된다. 따라서 본 연구에서는 RFI 공정에서 수지필름 두께 설정을 위한 방법을 제시하였다. 적정 수지필름 두께를 설정하는 방법으로 섬유압착거동 시험을 제시하였고, 제시된 방법의 검증을 위해 숏빔전단강도시험, 압축시험, 기공률 측정을 통해 복합재 물성을 평가하였다. 복합재 물성 평가 결과, 섬유압착거동시험 결과를 바탕으로 적정 수준의 수지필름 두께를 찾을 수 있었다.

RFI 공정 부품 비파괴검사용 표준 기공률 시편 제조 방법 및 기공률에 따른 기계적 물성 영향에 대한 연구 (A Study on Manufacturing Method of Standard Void Specimens for Non-destructive Testing in RFI Process and Effect of Void on Mechanical Properties)

  • 한성현;이정완;김정수;김영민;김위대;엄문광
    • Composites Research
    • /
    • 제32권6호
    • /
    • pp.395-402
    • /
    • 2019
  • RFI 공정은 진공백 내부에 섬유 매트와 수지 필름을 적층하여 성형하는 OoA 공정이다. 외부에서 따로 주입되는 수지가 없기 때문에 수지 필름의 양이 섬유가 필요로 하는 양보다 적은 경우 복합재 내부에 기공 결함이 발생하며 기계적 물성이 저하된다. 이러한 이유로 제작한 복합재를 실용화하기 위해서 비파괴검사를 이용한 기공예측이 필수적으로 요구된다. 따라서 본 연구에서는 RFI 공정에서 비파괴검사 시 기준으로 사용할 수 있는 표준 기공률 시편을 제조하는 방법을 제시하였다. 표준 기공률 시편 제작 방법으로 수지 필름 두께를 조절하는 방법을 사용하였으며, 목표 기공률별 수지 필름 두께를 설정하기 위한 방법으로 섬유 압착 실험을 제시하였다. 수지 필름 두께 조절을 통하여 0%, 2%, 4%의 목표 기공률 패널을 제작했고 비파괴시험과 기공률 측정을 통하여 기공률에 따른 비파괴검사 신호 감쇠를 측정했다. 또한 인장, 면내전단, 숏빔, 압축 시편의 신호 감쇠를 통하여 기공률을 추정하였고, 기공률에 따른 기계적 물성을 평가하였다.

봉독이 피부 노화에 미치는 영향 (The Effect of Bee Venom Therapy on Skin Aging)

  • 김진명;김윤범
    • 한방안이비인후피부과학회지
    • /
    • 제23권2호
    • /
    • pp.27-40
    • /
    • 2010
  • Background and Objective : Increasing interest in anti-aging and anti-wrinkling agents for the skin has triggered the recent outflow of researches and studies in this field. This study was designed to investigate the effects of bee venom on skin wrinkling and skin aging by testing the skin wrinkling, skin elasticity, trans-epidermal water loss (TEWL), free radical level, anti-oxidative agent level, and skin tissue after infusion of bee venom on hairless mouse. Materials and Methods : Fifteen hairless mice aged between 36~40 weeks were divided randomly into 3 Group; the Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group. The Bee Venom Syringe Group were injected subcutaneously with bee venom (0.1cc in total) using an insulin syringe on three spots in the lumbar spine (one spot on the center and two spots 1~2cm to the side bilaterally). The Bee Venom Needle Group were pricked with bee venom-smeared acupuncture needles on three longitudinal spots in the lumbar spine each 1cm apart, after which the needles were removed 10 minutes later. The Control Group did not receive any form of intervention. All procedures took place thrice a week for four weeks, during which the mice were allowed free access to water and fodder. The mice were measured and compared in the weight, skin wrinkling scale, skin elasticity, and TEWL before and after the experiment. After the experiment, blood samples were taken to measure the free radical and anti-oxidative agent level, and the skin tissue was sliced for examination. Data was analyzed using the SPSS program (ver 12.0). The ANOVA analysis was used to compare and contrast the three groups, and t-test for paired samples was used to evaluate skin-wrinkling before and after experiment. The cut-off p-value of significance was set at p<0.05. Results : 1. Administration of bee venom did not cause serious weight loss or gain. 2. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed a decrease in skin wrinkling scale after intervention. Especially, the Bee Venom Syringe Group showed a significant decrease (p<0.05). 3. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed an increase in skin elasticity. Especially, the Bee Venom Syringe Group showed a significant increase (p<0.05). 4. No significant change in TEWL was found in the mice in all the three groups before and after experiment. 5. Free radical level was normal in all 15 mice in all the three groups, and anti-oxidative agent was not significantly different across the three groups. 6. The Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group did not show any significant difference in the thickness of epidermis and dermis, infiltration of inflammatory cells, and skin wrinkling. The epidermis layer was relatively better preserved in the Bee Venom Syringe Group as compared to the Bee Venom Needle Group and the control group. Conclusion : Direct injection of bee venom on the hairless mouse using a syringe was found to improve wrinkling of the skin and increase skin elasticity but did not show effectiveness on skin dryness due to water loss. The bee venom appears to have suppressive effects on skin wrinkling, one of the symptoms of skin aging, through a process independent of suppression of free radicals or increase of anti-oxidative agent.

Streptococcus mutans에 대한 클로르헥시딘과 Erythrosine 광역동 치료의 상승효과 (Enhancement of Erythrosine Photodynamic Therapy against Streptococcus mutans by Chlorhexidine)

  • 박종철;박호원;이시영
    • 대한소아치과학회지
    • /
    • 제40권4호
    • /
    • pp.241-246
    • /
    • 2013
  • 이 연구의 목적은 치과 임상에서 널리 사용되는 항미생물제제인 클로르헥시딘과 할로겐을 이용한 erythrosine 광역동 치료를 병용하였을 때, 부유 상태의 Streptococcus mutans에 미치는 항균효과를 평가하기 위함이다. S. mutans 표준 균주를 Brain Heart Infusion broth medium에 첨가하여 부유 상태로 배양하였다. 치과용 할로겐 광중합 장치를 광원으로 사용하였으며 치태 착색제인 erythrosine을 광감각제로 사용하였다. 클로르헥시딘의 최소살균농도를 측정하고, erythrosine 광역동 치료에서 최소살균농도를 결정하기 위해 $1{\mu}M$, $5{\mu}M$, $10{\mu}M$의 erythrosine 농도를 사용하여 할로겐 광중합기로 15초 동안 광조사를 시행한 후 세균수를 측정하였다. 마지막으로 클로르헥시딘과 erythrosine 광역동 치료를 병용한 경우 나타나는 상승효과를 평가하기 위해, 최소살균농도 이하인 0.001% 클로르헥시딘과 최소살균농도 이하인 $1{\mu}M$ erythrosine 광역동 치료를 병용하여 항균효과를 비교하였다. 최소살균농도 이하의 클로르헥시딘만 단독으로 사용하는 경우 S. mutans의 세균수가 유의하게 감소하지 않았다(p < 0.05). 또한 erythrosine 광역동 치료만 단독으로 시행한 경우에는 $5{\mu}M$, $10{\mu}M$의 erythrosine 농도에서 유의하게 세균수가 감소하였지만, $1{\mu}M$ erythrosine 농도에서는 세균수가 유의하게 감소하지 않았다(p < 0.05). 마지막으로 두 가지 치료법의 상승효과를 평가하기 위해 최소살균농도 이하인 $1{\mu}M$ erythrosine 광역동 치료와 0.001% 클로르헥시딘을 병용하는 경우에는, 대조군과 비교하여 세균수가 유의하게 감소하였다(p < 0.05). 최소살균농도 이하인 0.001% 클로르헥시딘과 $1{\mu}M$ erythrosine 광역동 치료를 각각 단독으로 시행하는 경우에는 유의한 항균효과가 없었지만, 두 가지 치료를 병용하는 경우 61%의 S. mutans 세균수가 감소하였다. 이상의 결과를 종합해 볼때 S. mutans에 대해 최소살균농도 이하의 클로르헥시딘과 erythrosine 광역동 치료를 병용하는 경우 상승효과가 있음을 알 수 있다.

$TiO_2$ 농도 및 여기광에 따른 광촉매 반응이 Streptococcus mutans의 생장에 미치는 영향 (Influence of $TiO_2$ Concentrations and Irradiation Lights on the Photocatalytic Reaction for Inhibiting Growth of Streptococcus mutans)

  • 강시묵;이해나;김희은;김백일
    • 치위생과학회지
    • /
    • 제14권3호
    • /
    • pp.319-324
    • /
    • 2014
  • 본 연구는 광촉매 반응을 이용하여 치아우식증의 주요 원인균인 S. mutans를 조절하기 위한 새로운 방법을 제안하고자 기존 이산화 티타늄 광촉매에 주로 사용되었던 자외선영역의 광원과 현재 임상현장에서 활용되고 있는 405 nm의 가시광선 빛에 의한 광촉매 반응을 유도하여 항균효과를 비교하였다. 우선 최적의 이산화 티타늄 농도를 탐색한 결과 254 nm 또는 405 nm 빛 조사시 0.1 mg/ml의 농도에서 S. mutans에 대한 항균력이 각각 93%와 24%로 가장 높게 나타났다. 또한 광조사 시간과 S. mutans에 대한 항균력은 정비례 관계를 보였으며, 254 nm의 빛은 20분 이상, 그리고 405 nm의 빛은 40분 이상 조사할 경우 $10^4CFU/ml$ 정도의 생균이 완전히 사멸되는 결과를 확인하였다. 따라서 이산화티타늄의 광촉매 반응은 인체에 무해한 405 nm의 가시광선으로 유도될 수 있으며, 향후 항균력을 보다 증가시킬 수 있는 방법을 고안 한다면 임상현장에서 효과적으로 구강 내 S. mutans를 억제하는 데 활용이 가능할 것으로 예상된다.

구강 내 사슬알균 종들에 대한 제3인산나트륨과 구연산의 탈부착 효과 (The Anti-Sticking Effect of Mixture of Trisodium Phosphate and Citric Acid on Oral Streptococcus species)

  • 정충현;조형훈;최광주;강승용;양남웅
    • 미생물학회지
    • /
    • 제44권4호
    • /
    • pp.289-292
    • /
    • 2008
  • Irisodium phosphate 12 hydrate와 citric acid monohydrate의 혼합액은 유리구슬(${\phi}7mm$)에 부착된 Streptococcus mutans (KCTC 3065)와 Streptococcus mitis (KCTC 3556) 및 Streptococcus salivarius (KCTC 3960)에 대하여 강한 항 부각효과를 보였다. 각 사슬알균 종들은 각각 3개의 유리구슬들이 들어있는 BHI 액체배지에서 18시간 흔들 배양되었다. 배양 후, 3개의 짧은 핀들이 부착된 핀셋을 사용하여 유리구슬들을 꺼낸 다음, 유리구슬에 맺힌 균액을 제거하기 위하여 생리식염수로 가볍게 세척하였다. 각 균주당 3개의 유리구슬들을 시약들이 들어있는 시험관에 넣고 vortex mixer로 10분씩 와동(渦動)하였다. 칫솔질과 유사한 효과를 얻기 위해 각 시험관들에 물에 젖지 않는 기름종이 조각들을 40 mg씩 넣었다. 구강 내 사슬알균 종이 아닌 Streptococcus agalactiae는 5분간 와동(渦動)하였다. 각 시험관에서 취한 샘플들을 10배 계단 희석하여 BBH 한천 배지와 혼합하고 배양한 다음, 집락수를 계수하였다. 사슬알균 종 당실험을 3번 반복하였고, 시약에 의해 탈부착된 균수를 평균하여 생리식염수대조군의 평균으로 나누어 그 배수를 탈부착 효과로 계산하였다. treptococcus mutans에 대하여 구연산-제3인산나트륨-식염수혼합액(이하 CTS, pH 6.0)의 탈부착 효과는 생리식염수 대조군에 비해서 평균 12.5배였으며, 제3인산나트륨-식염수 혼합액(이하 TS, pH 8.4)은 평균 7.5배였고, 구연산-식염수 혼합액(이하 CS, pH 4.6)은 6.0배였다. Streptococcus salivarius에 대해서 CTS는 7.2배, TS는 2.6배, CS는 2.8배였다. Streptococcus mitis에 대해서 CTS는 2.4배였고, TS는 3.4배였으나 CS는 0.3배로 탈부착 효과가 없었다. 구강 내 사슬알균 종이 아닌 Streptococcus agalactiae에 대해서 CTS는 0.7배, TS는 0.6배, CS는 0.6배로 3가지 시약에 대하여 탈부착 효과가 전혀 없었다. 이러한 결과들은 충치와 아급성 심내막염의 원인균인 구강 내 Streptococcus mutans, Streptococcus salivarius 및 Streptococcus mitis가 CTS 혼합물에 의해서 구강으로부터 쉽게 제거될 수 있음을 의미한다. 따라서 이러한 결과를 응용하면 새로운 개념의 치약을 개발할 수 있을 것으로 생각되며, 충치의 예방 및 발치 후 아급성 심내막염의 예방에 도움이 될 것으로 사료된다.

PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가 (Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT)

  • 김창현;이현국;송치옥;이기흔
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.22-27
    • /
    • 2014
  • PET/CT검사는 장비의 발전과 더불어 환자의 피폭을 줄이기 위하여 저 선량을 사용하는 추세에 있다. 이에 PET/CT scanner의 영상의 질을 유지하기 위하여 주입선량의 변화에 따른 적정한 bed당 획득시간을 평가하고자 한다. 모형 실험은 NEMA NU2-1994 phantom으로 hot cylinder의 농도를 3, 4.3, 5.5, 6.7 MBq/kg 으로 증가시키고 bed당 획득시간을 30 sec, 1 min, 1 min 30 sec, 2 min, 2 min 30 sec, 3 min, 3 min 30 sec, 4 min, 4 min 30sec, 5 min, 5 min 30 sec 10 min, 20 min, 30 min로 늘려가며 영상을 획득 후 hot cylinder의 농도와 배후 방사능에 4개의 ROI (Region of Interest)을 설정하고 hot cylinder의 농도 와 bed당 획득시간에 따른 변화를 최대 표준섭취계수(Standard Uptake Value maximum, $SUV_{max}$)를 측정 후 신호 대 잡음비(Signal to Noise Ratio, SNR), BKG (Background)의 표준편차를 계산하여 비교해 보았다. 또한 4.3 MBq phantom을 이용하여 검사 대기시간의 변화(15분과 1시간)에 따른 각각의 $SUV_{max}$, SNR, BKG의 표준편차를 비교하였다. 단위 질량당 방사능의 농도가 3, 4.3, 5.5, 6.7 MBq으로 증가하고 또한 각 농도의 time/bed을 1분30초에서 30분까지 늘렸을 때 hot cylinder의 $SUV_{max}$ 값은 bed당 획득시간이 각 방사능의 농도에 따라 30초에서 2분까지는 최대 18.3에서 최소 7.3까지 변화가 심했고 2분 30초에서 30분까지는 최대 8에서 최소 5.6으로 일정한 $SUV_{max}$ 값을 나타내었다. 단위 질량당 방사능의 변화에 따른 SNR은 3 MBq에서는 최소 0.41에서 최대 0.49까지 일정하였고 4.3 MBq과 5.5 MBq에서는 각각 최소 0.23, 0.39에서 최대 0.59, 0.54로 bed당 획득시간이 늘수록 상승하였다. 방사능 농도 6.7 MBq에서는 30초에서 최대 0.59로 높았지만 이후 0.43에서 0.53으로 일정하게 유지하였다. BKG (Background)의 표준편차는 3 MBq에서 2분 30초 후부터 0.38에서 0.06으로 낮아졌고 4.3 MBq과 5.5 MBq에서는 1분 30초 후부터 0.38에서 0으로 낮아졌고 6.7 MBq에서는 30초에서 30분 전 구간에서 낮은 0.33에서 0.05이었다. 4.3 MBq 팬텀으로 검사대기시간을 15분과 1시간으로 변화시킨 결과에서는 bed당 획득시간이 2분 30초부터 $SUV_{max}$값이 서로 일정한 값을 보였고 SNR은 1분 30초부터 비슷한 값을 보였다. 위 결과와 같이 단위 질량당 주입된 방사능의 농도를 3, 4.3, 5.5, 6.7 MBq으로 증가시켰을 때 bed당 획득시간이 2분 30초 이상에서는 $SUV_{max}$와 SNR의 값이 서로 일정하게 유지되고 검사 대기시간의 변화(15분과 1시간)에서도 bed당 획득시간이 2분 30초 이상에서는 $SUV_{max}$와 SNR의 값이 일정하게 유지되는 것을 알 수 있었다. 이 NEMA NU2-1994 phantom 실험의 결과에서 주입되는 방사능의 농도의 변화에도 일정한 $SUV_{max}$와 SNR의 값을 구하기 위한 최소 bed당 획득시간은 2분 30초이라는 것을 알 수 있었다. 하지만 이 획득시간은 장비의 사양과 특성에 따라 차이가 있을 수 있다.

  • PDF