• 제목/요약/키워드: Infrared thermal Video

검색결과 25건 처리시간 0.028초

적외선 센서를 이용한 열상장비의 구현 (Thermal Imager Implementation Using Infrared Sensor)

  • 유위경;윤은숙;김창우;송인섭;홍석민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

Thermal Infrared Image Analysis for Breast Cancer Detection

  • Min, Sedong;Heo, Jiyoung;Kong, Youngsun;Nam, Yunyoung;Ley, Preap;Jung, Bong-Keun;Oh, Dongik;Shin, Wonhan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권2호
    • /
    • pp.1134-1147
    • /
    • 2017
  • With the rise in popularity of photographic and video cameras, an increasing number of fields are now using thermal imaging cameras. One such application is in the diagnosis of breast cancer, as thermal imaging provides a low-cost and noninvasive method. Thermal imaging is particularly safe for pregnant women, and those with large, dense, or sensitive breasts. In addition, excessive doses of radiation, which may be used in traditional methods of breast cancer detection, can increase the risk of cancer. This paper presents one method of breast cancer detection. Breast images were taken using a thermal camera, with preliminary experiments conducted on Cambodian women. Then the experimental results were analyzed and compared using Shannon entropy and logistic regression.

내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가 (Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside)

  • 이주엽;송민정;이태강;김선우;천득염
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study

  • Kim, Young-Koo;Lee, Hae-Jin;Kim, Jihee
    • Medical Lasers
    • /
    • 제9권2호
    • /
    • pp.159-165
    • /
    • 2020
  • Background and Objectives The ultimate goal in current skin rejuvenation practice is to achieve a good result with minimal pain and downtime. Nonablative skin rejuvenation (NSR) is one technique. The efficacy of the long-pulsed 1064 nm Nd:YAG laser (LPNDY) has not been assessed in NSR. Materials and Methods Three target areas were selected (bilateral cheeks and glabellar region) in six volunteer subjects. A LPNDY with an integral skin temperature monitor delivered three stacked shots to each target area (1064 nm, 12 mm spot, 13 J/cm2, 1 Hz) without any skin cooling or anesthesia. The skin temperature was recorded before, during, and after each set of shots using the system monitor and in real-time using a high-sensitivity (±0.001℃) near-infrared video camera. The skin reaction was observed with the naked eye, and pain and discomfort were assessed by the subjects during and after treatment. Results The subjects reported a mild feeling of heat with no discomfort during or after the test treatments. Mild erythema was observed around the treatment areas, without noticeable edema. A series of three ascending skin temperature stepwise peaks, with a decrease in skin temperature towards the baseline after the third shot, was observed consistently. The mean temperatures for shots 1, 2, and 3 for the cheeks were 39.5℃, 42.0℃, and 44.4℃, respectively, and for the glabella, 40.8℃, 43.9℃, and 46.2℃, respectively. Similar ranges were indicated on the system integral temperature monitor. Conclusion A set of three stacked pulses with the LPNDY at a low fluence achieved ideal dermal temperatures to achieve some dermal remodeling but without any downtime or adverse events. The temperature data from the integral thermal sensor matched the video camera measurements with practical accuracy for skin rejuvenation requirements. These data suggest that LPNDY would satisfy the necessary criteria to achieve effective NSR, but further studies will be needed to assess the actual results in clinical practice.

적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정 (Distance Measurement of Small Moving Object using Infrared Stereo Camera)

  • 오준호;이상화;이부환;박종일
    • 전자공학회논문지SC
    • /
    • 제49권3호
    • /
    • pp.53-61
    • /
    • 2012
  • 본 논문에서는 스테레오 적외선 카메라를 이용하여 소형 및 고온으로 날아가는 이동체의 거리를 실시간으로 측정하는 시스템을 제안한다. 이동체와 주변 환경의 온도 차이를 측정하고 고속으로 이동하는 소형 이동체의 거리를 자동으로 측정하기 위하여 적외선 스테레오 카메라 시스템을 구축하였다. 우선 적외선 카메라를 이용하여 취득한 고온의 이동체 영상으로부터 주변의 온도분포와 이동체간의 온도차를 이용하여 이동체영역을 검출하고, 이동체의 움직임 정보와 적외선 카메라 영상의 밝기정보를 결합하여 이동체를 추적한다. 좌우 적외선 카메라 영상에 대하여 각각 추출된 이동체 영역을 중심으로 스테레오 정합을 수행하여 시차정보를 추정하고, 카메라 파라미터와 시차정보를 이용하여 실시간으로 이동하는 이동체의 거리를 추정한다. 본 논문에서 제안하는 적외선 스테레오 카메라 시스템을 검증하기 위하여 고온의 이동체를 촬영할 때, 3차원 궤적(x,y,z) 측정기를 함께 가동하여 이동체가 이동하는 거리를 측정하여 이를 기준 거리(ground truth)로 설정하였다. 3차례의 비디오 데이터로부터 실험한 결과, 적외선 스테레오 카메라를 이용한 고온/소형 이동체의 거리오차 측정 결과는 평균적으로 9.68%로 추정되었다. 스테레오 적외선 카메라의 타이밍 문제(jitter)를 고려하면, 실제로 추정 오차는 줄어들 것으로 판단되기 때문에, 향후 적외선 카메라를 이용하는 다양한 이동체의 거리 및 위치를 측정하는데 응용할 수 있을 것으로 기대된다.

열화상 영상 안정화 성능 비교 (Infrared Thermal Video Stabilization Performance Comparison)

  • 박찬혁;권혁신;강석훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.101-104
    • /
    • 2015
  • 영상에서 이전 프레임과 현재 프레임을 비교하여 얼마나 움직였는지를 나타내는 모션 벡터(motion vector)라 한다. 이러한 모션 벡터를 이용하여 현재 프레임의 이미지안의 객체들이 이전프레임의 이미지 객체가 있었던 위치로 보정을 한다면 손 떨림이나 카메라의 흔들림에서 오는 작은 떨림을 보정할 수 있다. 본 논문에서는 모션 벡터를 추출하는 방법인 SAD(Sum of Absolute Difference) 방정식을 이용한 블록 정합 매칭 알고리즘, 위상상관을 이용한 매칭, 특징점을 이용한 매칭, Bitplane을 이용한 블록매칭의 성능을 비교하였다.

  • PDF

열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법 (Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography)

  • 권성준;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.40-48
    • /
    • 2012
  • 콘크리트내의 철근의 부식은 열화와 콘크리트 구조물의 조기파괴의 주된 원인이 된다. 본 연구에서는 비파괴 기법 중 전자기적 열유도방법과 적외선 열화상기법을 이용한 철근부식평가가 시도되었는데, 부식 또는 비부식된 철근의 열특성 차이를 이용한 것이다. 본 논문은 이러한 개념을 배경으로 수행한 실험적 연구이며, 유도전류를 통해 콘크리트 표면으로부터 내부 철근을 가열하고 외부의 적외선 카메라를 이용하여 표면의 온도변화를 관측한다. 피복두께가 다른 콘크리트 시편은 앞면과 배면의 피복두께를 동일하게 제조하여 앞면에서 가열과 배면에서의 온도측정을 동시에 할 수 있도록 고안되었다. IC (Impressed Current) 방법을 통하여, 철근 부식을 촉진하였으며, 적외선 화상을 통하여 온도가열과 냉각을 전 시험과정에 걸쳐 측정하였다. 본 실험을 통하여 부식/비부식 철근의 뚜렷한 온도변화를 확인하였으며, 부식된 시편에서 빠른 온도증가속도 및 냉각속도를 평가하였다. 본 연구는 콘크리트 매립철근의 비파괴적인 부식탐지의 가능성을 보여주고 있다.

선형저밀도 폴리에틸렌 튜빙의 파손 메커니즘과 장기 정수압 거동 (Failure Mechanism and Long-Term Hydrostatic Behavior of Linear Low Density Polyethylene Tubing)

  • 원종일;정유경;신세문;최길영
    • 폴리머
    • /
    • 제32권5호
    • /
    • pp.440-445
    • /
    • 2008
  • 정수압 상태의 선형저밀도 폴리에틸렌 튜빙의 파손 메커니즘과 파손 모폴로지를 연구하였다. 비디오현미경과 주사전자현미경을 이용한 관찰 결과, 선형저밀도 폴리에틸렌 튜빙의 파손모드는 내면에서 외면으로 진전되는 크랙을 수반하는 취성파괴임을 확인하였다. 또한 산화유발시간과 적외선분광분석을 통하여, 파손된 선형저밀도 플리에틸렌 튜빙의 단면상에 열화에 의한 발열 피크와 카르보닐 피크의 증가를 관찰하였다. 열 가속에 의한 음력과 수명특성 사이의 관계를 고려한 선형저밀도 폴리에틸렌 튜빙의 가속수명시험법 및 시험장치를 개발하였다. 선형저밀도 폴리에틸렌 튜빙의 장기 정수압 상태의 수명을 예측하기 위해 아레니우스 모델과 와이블 분포를 적용한 통계학적 기법을 도입하였다. 그 결과, 사용온도 $25^{\circ}C$에서의 선형저밀도 폴리에틸렌 튜빙의 장기수명을 평가/분석하였다.

Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향 (The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature)

  • 박준석;김형대;배성원;김경두
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.567-578
    • /
    • 2015
  • Leidenfrost 온도 이상으로 가열된 벽면과 충돌하는 액적의 속도가 열전달 특성에 미치는 영향에 관한 실험 연구를 수행하였다. 동기화된 초고속 가시화 카메라와 적외선 카메라를 이용하여 벽면과 충돌하는 액적의 충돌 특성과 충돌면의 온도 분포를 측정하였다. 획득한 표면온도 분포를 충돌면의 경계 조건으로 이용하여 가열 벽면의 3차원 비정상 열전도 수치해석을 통해 표면 열유속 분포를 얻었다. 수직방향 충돌속도가 증가할수록 최대 액막 직경이 증가하고 가열 벽면과 액막 사이에 존재하는 증기막의 두께가 감소하여 열전달 효율이 증가하였다. 액적은 웨버수가 30보다 작은 경우 되튐현상이 발생하였으며, 큰 경우 작은 액적들로 분쇄되어졌다. 충돌속도에 의한 열전달량의 증가 경향이 되튐영역에서 분쇄영역에서 가면서 약화되었으며, 이는 분쇄현상에 의해 유효 열전달 면적의 확대 효과가 저감되었기 때문으로 해석된다.

헤데라 헬릭스 식물의 적외선 열영상에 의한 저온 및 한풍피해에 관한 연구 (An Analysis Method on Injury Symptoms Utilizing Infrared Thermal Imaging under the Freezing Stress of Hedera helix L.)

  • 성부근
    • 한국조경학회지
    • /
    • 제40권6호
    • /
    • pp.173-179
    • /
    • 2012
  • Hedera helix의 저온에서의 피해 및 생육진단을 위하여 적외선서모그라피에 의해 측정한 적외선 열영상으로 부위별 체표면온도를 해석하였다. 노지재배품 첨단부와 기부의 엽신에 대한 실험설정온도 $-6^{\circ}C$구와 $-12^{\circ}C$구의 온도분포를 각각 비교해보았다. 결과 노지재배품 첨단부의 $-6^{\circ}C$실험구에서의 엽면온도는 $-2^{\circ}C{\sim}-7^{\circ}C$의 분포를, $-12^{\circ}C$실험구에서는 $-2^{\circ}C{\sim}-15^{\circ}C$까지의 범위에 분포하고 있었다. 한편 노지재배품 기부의 엽면온도는 $-6^{\circ}C$실험구에서의 엽면온도는 $-2^{\circ}C{\sim}-11^{\circ}C$의 분포를, $-12^{\circ}C$실험구에서는 $-1^{\circ}C{\sim}-12^{\circ}C$까지의 범위에 분포하고 있었다. 이를 보면 $-6^{\circ}C$실험구에서는 첨단부쪽이, $-12^{\circ}C$실험구에서는 기부쪽이 보다 광범위한 온도분포를 보여 주었다. 이는 대체적으로 기부 쪽보다는 첨단부 쪽의 엽신이 저온감수성이 높은 것을 의미한다. 한풍피해를 규명하기 위하여 노지재배품의 평균엽면온도를 측정한 결과 $0^{\circ}C$실험구에서 $-6.2^{\circ}C$, $-2^{\circ}C$실험구에서 $-6.8^{\circ}C$, $-4^{\circ}C$실험구에서 $-7.5^{\circ}C$를 나타내어 각각의 설정온도(공기온도) 보다도 $3.5{\sim}6.2^{\circ}C$ 저온이었으며 부위별로 온도가 다른 점으로 보아 저온감수성이 상이한 것으로 추론하였다.