• Title/Summary/Keyword: Infrared protocol

Search Result 27, Processing Time 0.024 seconds

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

Synthesis of pt(II) Complexes Containing Diphosphines and Evaluation of Antitumor Activity (디포스핀류 배위자를 함유한 백금(II) 착체의 합성과 항암효과)

  • Noh, Young-Soo;Masahide, Noji
    • Journal of Pharmaceutical Investigation
    • /
    • v.20 no.4
    • /
    • pp.217-222
    • /
    • 1990
  • New antitumor-active pt(II) complexes of trans-l-diamine cyclohexane containing diphosphines as a leaving group were synthesized. The structures of the pt(II) complexes were determined by analyzing the infrared and $^{31}P-nuclear$ magnetic resonance spectra. Antitumor activities of the pt(II) complexes were tested against murine leukemia $L_{l210}$ according to the protocol of the National Cancer Institute. All the pt(II) complexes Synthesized were antitumor-active. In particular, water-soluble $[pt(trans-l-dach) (DPPP)](NO_3)_2$ exhibited excellent antitumor activity, giving T/C % values of 341 and 356 respectively, each with four cured mice out of six at a dose of 25 mg/kg. These pt(II) complexes are considered to be worthy of further development.

  • PDF

Automatic Fish Size Measurement System for Smart Fish Farm Using a Deep Neural Network (심층신경망을 이용한 스마트 양식장용 어류 크기 자동 측정 시스템)

  • Lee, Yoon-Ho;Jeon, Joo-Hyeon;Joo, Moon G.
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.3
    • /
    • pp.177-183
    • /
    • 2022
  • To measure the size and weight of the fish, we developed an automatic fish size measurement system using a deep neural network, where the YOLO (You Only Look Once)v3 model was used. To detect fish, an IP camera with infrared function was installed over the fish pool to acquire image data and used as input data for the deep neural network. Using the bounding box information generated as a result of detecting the fish and the structure for which the actual length is known, the size of the fish can be obtained. A GUI (Graphical User Interface) program was implemented using LabVIEW and RTSP (Real-Time Streaming protocol). The automatic fish size measurement system shows the results and stores them in a database for future work.

Effect of Photothermal Therapy with Indocyanine Green in Multispecies Biofilm (Indocyanine Green을 이용한 광열 치료의 다종 우식원성 바이오필름에 대한 효과)

  • Kim, Myunghwan;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2021
  • The purpose of this study is to investigate the antibacterial effects of indocyanine green (ICG) and near-infrared diode lasers on multispecies biofilms. Multispecies biofilms of Streptococcus mutans, Lactobacillus casei and Candida albicans were treated with different irradiation time using photosensitizer ICG and 808 nm near-infrared diode laser. Colony forming unit (CFU) was measured, and qualitative evaluation of biofilm was performed with confocal laser scanning microscopy (CLSM). Temperature measurement was conducted to evaluate photothermal effect. In the groups using ICG and diode laser, reduction in CFU was statistically significant, but the difference in antibacterial effect on L. casei and C. albicans with irradiation time was not significant, and similar results were confirmed with CLSM. Groups with ICG and diode laser showed higher temperature elevation than groups without ICG, and results of measured temperature were similar to the range of hyperthermia. In conclusion, ICG and near-infrared diode laser showed antibacterial effects on multispecies biofilms, but studies on protocol are necessary for clinical application.

Concentration Range Analysis for Fluorescence Expression of Indocyanine Green (Indocyanine green 형광조영제의 형광발현을 위한 농도 범위 분석)

  • Kim, Yong Jae;Lee, Da Ae;Yoon, Ki-Cheol;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1339-1346
    • /
    • 2019
  • In the characteristic of the brain malignant, the blood vessels and tumors have the same color and shape, and the boundary distinction is not clear, Therefore, it is difficult to observe the naked eye. Because of the high invasiveness, the risk of recurrence is high. Therefore, complete resection of the tumor is essential. The method for distinguishing the boundary between blood vessels and tumors is a fluorescence contrast method using indocyanine green (ICG), a fluorescence contrast agent. In ICG, the concentration range analysis is very important because the fluorescence expression state varies depending on the concentration. However, since the analysis result of the fluorescence expression condition is insufficient according to the current concentration, this paper proposes by analyzing the initial protocol of the concentration range. 780 nm infrared light was irradiated to the ICG sample to observe the fluorescence expression through a near infrared (NIR) camera. The wavelength is measured by using a spectrum instrument (ocean view) to observe the fluorescence expression wavelength of 811nm. As a result of analyzing the mol concentration according to each sample, the fluorescence expression range was found to be 16.15-0.16M and the optimum fluorescence concentration on the brightest part was found to be 3.23-0.81M.

Polyaniline/SiO2 Catalyzed One-pot Mannich Reaction: An Efficient Synthesis of β-amino Carbonyl Compounds (Polyaniline/SiO2를 이용한 one-pot Mannich 반응: β-amino carbonyl 화합물의 효율적인 합성)

  • Yelwande, Ajeet A.;Arbad, Balasaheb R.;Lande, Machhindra K.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.644-649
    • /
    • 2011
  • Polyaniline/$SiO_2$ catalyzed one-pot mannich reaction of acetophenone, aromatic aldehydes and aromatic amines are carried out in ethanol to afford various ${\beta}$-amino ketones. The various wt% of polyaniline were supported on pure silica synthesized by using chemical oxidative method. The catalyst prepared has been characterized by means of thermal analysis (TG-DTA), X-ray diffraction (XRD), scanning electron microscopy (SEM) energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR). Solvent stability of catalyst was tested using UV-Visible spectroscopy. This protocol has several advantages such as high yield, simple work up procedure, non-toxic, clean, easy recovery and reusability of the catalyst.

Design Adaptive Acoustic Echo Canceller for AVRCP Bluetooth Hands Free (AVRCP 기반의 블루투스 핸즈프리를 위한 음향반향제거기 설계)

  • Jung, Yong-Gyu;Kim, Kyeong-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.33-38
    • /
    • 2009
  • Recently most of A/V devices are being adopted hi-tech of A VRCP and changed to mobile environment. AVRCP is designed to provide a standard interface to control A/V devices, hi-fi equipment, or others to allow a single remote control or other device to control all the A/V equipment to which a user has access. It may be used in concert with A2DP or VDP. The AVRCP defines two roles, that of a controller and target device. In AVRCP, the controller translates the detected user action to the A/V control signal, and then transmits it to a remote Bluetooth enabled device. It can be small and mixed mobile devices using bluetooth technologies. The functions available for a conventional infrared remote controller can be realized in this protocol. The remote control described in this protocol is designed specifically for A/V control only. We designed new DSP using Adaptive Acoustic Echo Canceller for bluetooth hands free based this AVRCP standard specifications.

  • PDF

Effects of a simplified drilling protocol at 50 rpm on heat generation under water-free conditions: an in vitro study

  • Hyeon-Ji Jang;Jin-Un Yoon;Ji-Young Joo;Ju-Youn Lee;Hyun-Joo Kim
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.1
    • /
    • pp.85-95
    • /
    • 2023
  • Purpose: In recent years, guided implant surgery has been widely used for the convenience of patients and surgeons. Further streamlining the surgical procedure would make implant surgery more convenient. Low-speed water-free conditions are often used in guided implant surgery. Therefore, in this study, we attempted to confirm once again whether drilling was safe at a low speed without water. The main purpose of this study was to evaluate whether a simplified drilling protocol that omits some intermediate steps in the drilling process was safe from the viewpoint of heat generation. Methods: D1 density artificial bone blocks were drilled under 50 rpm, 10 N·cm water-free conditions, and the surface temperature was measured using a digital infrared camera. First, drilling was performed with the sequential drilling method, which is the most widely used technique. Second, for each drill diameter, the temperature change was measured while performing simplified drilling with omission of the previous 1, 2, or 3 steps. Results: In sequential drilling, the heat generated during drilling at all diameters was less than the critical temperature of osteonecrosis (47℃) except for the ⌀2 drill. Statistical significance was observed in all groups when comparing sequential and simplified drilling in the ⌀3.2, ⌀3.8, and ⌀4.3 drills (P<0.001). However, in the simplified drilling procedures, the temperature was below the osteonecrosis threshold temperature (47℃) except for the ⌀4.3 drill with the omission of the previous 3 steps (⌀3.0, ⌀3.2, and ⌀3.8). Conclusions: In general, drilling under low-speed, water-free conditions has shown stable results in terms of heat generation. Simplified drilling showed statistically significantly greater heat generation than sequential drilling. However, most of the diameters and omitted steps seem to be clinically acceptable, so it will be useful if an appropriate selection is made according to the patient's clinical condition.

Effectiveness and Safety of Pharmacopuncture Therapy for Chronic Low Back Pain: A Study Protocol for a Pragmatic Randomized Controlled Trial

  • Youn Young Choi;Hwa Yeon Ryu;Jae Hui Kang;Hyun Lee
    • Journal of Acupuncture Research
    • /
    • v.41 no.2
    • /
    • pp.107-114
    • /
    • 2024
  • Background: Low back pain (LBP) is a common musculoskeletal disorder worldwide, with a lifetime prevalence of up to 80%. Among nonsurgical treatments for chronic LBP, Korean medicine treatments are highly preferred, and pharmacopuncture therapy combining acupuncture and herbal medicine is widely used. However, no evidence-based study has focused on the use of various types of pharmacopuncture. Methods: The pragmatic randomized controlled clinical trial will include 44 participants; recruitment will start in July 2023. All participants will receive integrated Korean medicine treatment including acupuncture, cupping, and infrared therapy, and the intervention group will also receive pharmacopuncture. After 16 treatment sessions, twice a week for 8 weeks, follow-up assessments will be performed at week 9. As a pragmatic randomized controlled clinical protocol, the type, dose, and acupoints of acupuncture and pharmacopuncture are not determined in advance but are selected and recorded according to the clinical judgment of the Korean medicine doctor. Results: The primary outcome will be measured using a visual analog scale score, and the secondary outcomes include the Oswestry disability index, patient global impression of change, no worse than mild pain, and range of motion. Safety will be assessed by examining participants' self-reported adverse events and vital signs and conducting blood tests before and after the test. Conclusion: This study aims to provide clinical evidence of the effectiveness and safety of pharmacopuncture for chronic LBP.

Development of a Transcutaneous Information Transmission System using Transmitted Light for the Total Artificial Heart (투과광을 이용한 인공심장용 무선정보전달 장치의 개발)

  • Kang, Dong-Woo;Kim, Hee-Chan;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.129-131
    • /
    • 1993
  • A transcutaneoos information transmission system using transmitted infrared light for an implantable total artificial heart(TAH) an developed and the performance of the system was tested. In an in vitro test, transmittance of the developed system was measured through various thicknesses of pig shins. In an in vivo test, a loopback test using a personal computer was performed to determine the error rate and an experiment using a mock system was taken. In this experiment, within acceptable lateral and vertical displacements, the error rate of at least 3.8E-6 was guaranteed. Monitoring signals from the internal controller(Intel 87C196) of the mock system were successfully transmitted to the external controller(IBM PC) and the operating commands from the external controller were successfully conducted by the mock system. Communication was done in half duplex mode according to RS-232 protocol at the speed of 4800 bps.

  • PDF