• 제목/요약/키워드: Infrared optic

검색결과 78건 처리시간 0.024초

근적외 분광분석법을 이용한 나프록센 정제의 정량분석 (Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제49권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

적외선 투과 광섬유를 이용한 고주파 열치료 과정에서의 온도분포 측정 (Measurements of temperature distribution using an infrared optical fiber during radiofrequency ablation)

  • 유욱재;서정기;조동현;장경원;신상훈;이봉수;탁계래;박병기;문주현
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.397-405
    • /
    • 2008
  • In this study, we have measured temperature distribution using infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted electrode are transferred by silver halide optical fibers and are measured by a thermopile sensor. Also, the output voltages of a thermopile sensor are compared with those of the thermocouple recorder. It is expected that a noncontact temperature sensor using an infrared optical fiber can be developed for the temperature monitoring during RFA treatments based on the results of this study.

가시광선과 원적외선 듀얼카메라의 영상 정합도 향상을 위한 동축광학계 설계 및 분석 (Design and Analysis of Coaxial Optical System for Improvement of Image Fusion of Visible and Far-infrared Dual Cameras)

  • 강규리;김영일;손병수;박진영
    • 한국광학회지
    • /
    • 제34권3호
    • /
    • pp.106-116
    • /
    • 2023
  • 본 논문에서는 가시광선과 원적외선 전반의 파장대역에 걸쳐 사용 가능한 동축 듀얼카메라를 설계 및 분석하였다. 광학계는 빔 스플리터를 이용한 동축광학계 시스템으로 설계되었으며, 가시광선 광학계에서 적외선으로 인한 열 전달을 최소화하기 위해 hot mirror 타입의 빔 스플리터를 사용하였다. 원적외선 카메라는 비냉각형 검출기로 640×480의 센서 배열을 가지고, 가시광선은 1,945×1,097의 센서를 사용한다. 최적화 과정을 거친 후 최종 설계된 광학계의 정합도는 90% 이상이며, 기존에 존재하던 듀얼카메라에 비해 정합도가 향상된 효율적인 설계 결과를 얻었고, 테스트를 통해 향상된 정합도를 확인하였다.

적외선 광학 소재의 초정밀 선삭가공시 발생하는 미세균열 연구 (Micro-Crack Analysis from Ultra-Precision Diamond Turning of IR Optic Material)

  • 정병준;김건희;명태식;정의식;최환진;여인주;전민우
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.905-910
    • /
    • 2016
  • Infrared (IR) optic lens can be fabricated by a single point diamond turning (SPDT) machine without subsequent polishing process. However, this machining process often leaves micro-cracks that deteriorate the surface quality. In this work, we propose an experimental design to remove micro-cracks on IR lens. The proposed design gathered data between cutting process condition and Rt surface roughness. This is of great importance because the scale of micro-cracks is a few micrometer. Rt surface roughness is suitable for analyzing maximum peak height signals of the profile. The experimental results indicate that feed per revolution variable is one of the most dominant variable, affecting the generation micro-cracks on IR lens surfaces.

PZT 세라믹의 전기광학적 특성에 관한 연구 (Study for Electro-optic Properties of PZT Ceramics)

  • 김시중;김건;안병준
    • 대한화학회지
    • /
    • 제36권1호
    • /
    • pp.51-56
    • /
    • 1992
  • 페로브스카이트구조를 갖는 $Pb(Zr_{1-y}Ti_y)O_3$ (PZT)계의 $Pb^{2+}$ 위치에 $Nd^{3+}$ 이온을 치환시키면서 그 결정구조와 결합특성을 X-선 회절분석법 및 적외선 분광광도법으로 알아보았으며, 이런 구조변화가 (Pb1-xNdx)(Zr1-yTiy)O3 (PNZT)계의 전기적 및 광학적 특성에 미치는 영향에 대하여 조사하였다. $Pb^{2+}$ 이온이 $Nd^{3+}$ 이온으로 치환될수록 정방성이 감소하며, 8${\sim}$12 mol% 치환되었을 때 입방정계의 구조이다. 결정내의 결합강도는 입방정게의 구조일 때 가장 강하고 높은 투광도를 나타냈으며, PNZT계 화합물이 투광도를 나타내는 것은 전자의 전하-이동 전이에 의한 것으로 생각된다.

  • PDF

열변형 보정을 통한 열화상카메라용 초정밀 칼코지나이드 유리렌즈 몰드성형 및 특성 평가 (Molding and Evaluation of Ultra-Precision Chalcogenide-Glass Lens for Thermal Imaging Camera Using Thermal Deformation Compensation)

  • 차두환;김정호;김혜정
    • 한국전기전자재료학회논문지
    • /
    • 제27권2호
    • /
    • pp.91-96
    • /
    • 2014
  • Aspheric lenses used in the thermal imaging are typically fabricated using expensive single-crystal materials (Ge and ZnS, etc.) by the costly single point diamond turning (SPDT) process. As a potential solution to reduce cost, compression molding method using chalcogenide glass has been attracted to fabricate IR optic. Thermal deformation of a molded lens should be compensated to fabricate chalcogenide aspheric lens with form accuracy of the submicron-order. The thermal deformation phenomenon of molded lens was analyzed ant then compensation using mold iteration process is followed to fabricate the high accuracy optic. Consequently, it is obvious that compensation of thermal deformation is critical and useful enough to be adopted to fabricate the lens by molding method.

Design of Dynamically Focus-switchable Fresnel Zone Plates Based on Plasmonic Phase-change VO2 Metafilm Absorbers

  • Kyuho Kim;Changhyun Kim;Sun-Je Kim;Byoungho Lee
    • Current Optics and Photonics
    • /
    • 제7권3호
    • /
    • pp.254-262
    • /
    • 2023
  • Novel thermo-optically focus-switchable Fresnel zone plates based on phase-change metafilms are designed and analyzed at a visible wavelength (660 nm). By virtue of the large thermo-optic response of vanadium dioxide (VO2) thin film, a phase-change material, four different plasmonic phase-change absorbers are numerically designed as actively tunable Gires-Tournois Al-VO2 metafilms in two and three dimensions. The designed phase-change metafilm unit cells are used as the building blocks of actively focus-switchable Fresnel zone plates with strong focus switching contrast (40%, 83%) and high numerical apertures (1.52, 1.70). The Fresnel zone plates designed in two and three dimensions work as cylindrical and spherical lenses in reflection type, respectively. The coupling between the thermo-optic effect of VO2 and localized plasmonic resonances in the Al nanostructures offer a large degree of freedom in design and high-contrast focus-switching performance based on largely tunable absorption resonances. The proposed method may have great potential in photothermal and electrothermal active optical devices for nonlinear optics, microscopy, 3D scanning, optical trapping, and holographic displays over a wide spectral range including the visible and infrared regimes.

QUICK DETERMINATION OF MEAT COLOR, METMYOGLOBIN FORMATION AND LIPID OXIDATION IN BEEF, PORK AND CHICKEN BY NEAR-INFRARED SPECTROSCOPY

  • Mitsumoto, Mitsuru;Sasaki, Keisuke;Murakami, Hitoshi
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1259-1259
    • /
    • 2001
  • Meat becomes brown and rancid during storage in the refrigerator and display in the case. Color changes, metmyoglobin formation and lipid oxidation are the important problems in the transportation / distribution of meat and retail display. The freshness of meat is determined by the sense of vision and smell. Since conventional method determining lipid oxidation is time consuming and destructive (it needs to homogenize meat with reagents, filtrate, time for reaction and read optical density using spectroscopy), more rapid and nondestructive technical tools are desired. The objective of this work was to evaluate near-infrared spectroscopy as an analytical tool for determining meat color, metmyoglobin formation and lipid oxidation. in beef, pork and chicken. Semitendinosus and longissimus thoracis muscles from six beef steers, biceps femoris and longissimus thoracis muscles from twelve LWD crossbred pigs, and superficial pectoral muscles from twenty-four broilers were used. About a 5-cm diameter and 1-cm thick sample (20.0g) was cut from the muscle and placed on plastic foam, over-wrapped with PVC film, and displayed under flourescent lights at 4 degrees C. during 10 days for beef and pork or 4 days for chicken. The spectra was measured by NIR systems Model 5500 Spectrophotometer using fiber optic scan at range of 400 - 1100 nm. Data were recorded at 2 nm intervals and 10 scans / 10 sec were averaged for every sample. Data obtained were saved as log 1/Re, where Re is the reflectance energy, and then mathematically transformed to second derivatives to reduce effects of differences in particle size. $L^{*}$, $a^{*}$ and $b^{*}$, and metmyoglobin formation were determined by conventional spectrophotometer using the integrating sphere unit. 2-Thiobarbituric acid reactive substances (TBARS) were measured for lipid oxidation. A multiple linear regression was used to find the equation which would best fit the data. The number of wavelengths used in the equation was selected based on the fewer number compared to the increasing multiple correlation and Decreasing standard error. (omitted)

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.