• Title/Summary/Keyword: Infrared gas sensor

Search Result 74, Processing Time 0.027 seconds

Development of Control System for Ultrasonic Spray Pyrolysis Deposition (초음파 분무 열분해 증착 제어 시스템 개발)

  • Kim, Kyu-Eon;Kim, Yeong-Heum;Lee, Chibum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.4
    • /
    • pp.385-391
    • /
    • 2014
  • A control system for ultrasonic spray pyrolysis deposition was developed that can coat a large size glass panel with a transparent conductive oxide. It consists of several ultrasonic atomizer devices to cover a large area and a host computer for individually controlling the devices. The sub-controller in an ultrasonic atomizer device can adjust the flow rate of the atomized conductive oxide gas by setting the flow rate of the solution and regulating the level of the solution in the tank. To construct a feedback control loop for level regulation, a level sensor that utilized an infrared distance sensor and an electric circuit for adjusting the ultrasonic oscillator were developed. The host program was also developed, which can monitor and control the sub-controllers. A proportional-integral controller was developed for a simplified model, and its operation was verified through an experiment.

Measurement of the Void Fraction in Slug Flow using an Optical Method (광학적 방법을 이용한 슬러그 유동의 기공률 측정)

  • Kim, Dong-Seon
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • Void fraction has been measured for the gas-liquid cocurrent slug flow in 8mm vertical acrylic tube using an optical method. Bubble speed, length and period could be measured with the two sets of laser-infrared sensor modules mounted 25mm apart alongside the tube, which were designed to detect variation of light intensities with a time delay when two parallel laser beams were refracted successively by a passing bubble. It was found that the results were in good agreement with the previous studies in the literature suggesting that the method used in this study were sound and accurate.

  • PDF

Design of novel optical cavity for NDIR gas sensor with high output power (고출력 NDIR 가스센서를 위한 새로운 optical cavity 설계)

  • Yu, Seon-Hwa;Yi, Seung-Hwan;Kwon, Kwang-Ho;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1641-1642
    • /
    • 2006
  • 본 연구에서는 NDIR(non dispersive infrared absorption) 가스센서의 소형화와 저가화를 목표로 2개의 오목 거울을 이용한 새로운 광 공동(optical cavity) 구조를 제안하고, 구조에 따른 광 출력 특성을 시뮬레이션하였다. Optical cavity는 광 경로증가 및 광 집속 구조로 설계하고, 각각의 출력단에서 검출되는 광 출력을 시뮬레이션한 결과 광 집속 구조의 팡 출력이 더 효율적임을 확인하였다. 집광구조에서의 광 출력을 최대로 하기 위해 광의 초점을 찾아보았다. 집광 구조를 사용하지 않는 단순 평행 광이 조사되는 경우, 적외선 센서부에 입사되는 광 출력은 최대 0.024W이다. 그러나 집광구조에서는 optical cavity의 광축에서 센서의 위치를 $15\sim20mm$까지 변화시켜 시뮬레이션한 결과 거리 18.83mm 일 때 조사되는 광 출력이 약 0.153W로 약 7배 증가됨을 확인하였다.

  • PDF

Fabrication of Silicon Window for Low-price Thermal Imaging System (저가형 열영상 시스템을 위한 실리콘 윈도우 제작)

  • Sung, Byung Mok;Jung, Dong Geon;Bang, Soon Jae;Baek, Sun Min;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.

JAXA'S EARTH OBSERVING PROGRAM

  • Shimoda, Haruhisa
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.7-10
    • /
    • 2006
  • Four programs, i.e. TRMM, ADEOS2, ASTER, and ALOS are going on in Japanese Earth Observation programs. TRMM and ASTER are operating well, and TRMM operation will be continued to 2009. ADEOS2 was failed, but AMSR-E on Aqua is operating. ALOS (Advanced Land Observing Satellite) was successfully launched on $24^{th}$ Jan. 2006. ALOS carries three instruments, i.e., PRISM (Panchromatic Remote Sensing Instrument for Stereo Mapping), AVNIR-2 (Advanced Visible and Near Infrared Radiometer), and PALSAR (Phased Array L band Synthetic Aperture Radar). PRISM is a 3 line panchromatic push broom scanner with 2.5m IFOV. AVNIR-2 is a 4 channel multi spectral scanner with 10m IFOV. PALSAR is a full polarimetric active phased array SAR. PALSAR has many observation modes including full polarimetric mode and scan SAR mode. After the unfortunate accident of ADEOS2, JAXA still have plans of Earth observation programs. Next generation satellites will be launched in 2008-2012 timeframe. They are GOSAT (Greenhouse Gas Observation Satellite), GCOM-W and GCOM-C (ADEOS-2 follow on), and GPM (Global Precipitation Mission) core satellite. GOSAT will carry 2 instruments, i.e. a green house gas sensor and a cloud/aerosol imager. The main sensor is a Fourier transform spectrometer (FTS) and covers 0.76 to 15 ${\mu}m$ region with 0.2 to 0.5 $cm^{-1}$ resolution. GPM is a joint project with NASA and will carry two instruments. JAXA will develop DPR (Dual frequency Precipitation Radar) which is a follow on of PR on TRMM. Another project is EarthCare. It is a joint project with ESA and JAXA is going to provide CPR (Cloud Profiling Radar). Discussions on future Earth Observation programs have been started including discussions on ALOS F/O.

  • PDF

Development and Evaluation of Portable Multiple Gas Meter (휴대용 다중 가스측정 장비 개발 및 평가)

  • Jang, Hee-Joong;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.483-490
    • /
    • 2019
  • Assessing the effect of forest fires and measuring the gas concentration around a fire has received little attention. Therefore, the concentrations of various gases in areas surrounding a fire need to be measured by the development of a suitable device. Unlike conventional portable devices, the AQS (Air Quality System) proposed in this paper is a portable instrument that measures five types of gases simultaneously, including CO, CO2, NOx, VOCs, and NH3, and has high durability through sensor protection algorithms. A PC-based program with an AQS connection was developed to monitor the real-time changes in the gas concentration. The reliability of the developed device was proven through a comparison of the results with other commercial gas analyzers. Measurements of the concentration due to indoor and outdoor fires were performed around a fire area to review the applicability and the predicted results were obtained.

Characteristics of in-situ doped polycrystalline 3C-SiCthin films for M/NEMS applications (In-situ 도핑된 M/NEMS용 다결정 3C-SiC 박막의 특성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.325-328
    • /
    • 2008
  • This paper describes the electrical properties of poly (polycrystalline) 3C-SiC thin films with different nitrogen doping concentrations. In-situ doped poly 3C-SiC thin films were deposited by APCVD at $1200^{\circ}C$ using HMDS (hexamethyildisilane: $Si_2(CH_3)_6)$) as Si and C precursor, and $0{\sim}100$ sccm $N_2$ as the dopant source gas. The peak of SiC is appeared in poly 3C-SiC thin films grown on $SiO_2/Si$ substrates in XRD(X-ray diffraction) and FT-IR(Fourier transform infrared spectroscopy) analyses. The resistivity of poly 3C-SiC thin films decreased from $8.35{\Omega}{\cdot}cm$ with $N_2$ of 0 sccm to $0.014{\Omega}{\cdot}cm$ with 100 sccm. The carrier concentration of poly 3C-SiC films increased with doping from $3.0819{\times}10^{17}$ to $2.2994{\times}10^{19}cm^{-3}$ and their electronic mobilities increased from 2.433 to $29.299cm^2/V{\cdot}S$, respectively.

Structural and temperature coefficient of resistance characteristics of colossal magnetoresistance Mn oxides prepared by RF sputtering

  • Choi, Sun-Gyu;Ha, Tae-Jung;Reddy, A.Sivasankar;Yu, Byoung-Gon;Park, Hyung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.361-361
    • /
    • 2007
  • A lot of efforts have been paid to develop infrared imaging systems in last decades. Bolometer has a wide range of applications from military to commercial, such as military night vision, medical imaging system and so on. Bolometer is a resistive sensor that detects temperature changes through resistance change. To improve detecting ability, bolometer should have a good resistive film which has high temperature coefficient of resistance (TCR) value. Colossal magnetoresistance (CMR) $L_{1-x}A_xMnO_3$ (where L and A are trivalent rare-earth ions and divalent alkaline earth ions, respectively.) are received attention to apply bolometer resistive film because it has a high TCR property which was discovered in the metal to semiconductor phase transition temperature region. In this work, CMR films were deposited on various substrates in relative low substrate temperature by RF magnetron sputtering. The influence of deposition parameters such as substrate temperature, gas partial pressure, and so on have been studied. The structural and TCR properties of the films were also investigated for applying to microbolometer.

  • PDF

Flow Characteristics of a Gas-Liquid Slug Flow in Small Vertical Tubes (작은 수직관을 흐르는 기-액 슬러그 유동의 유동특성)

  • Kye, Seok-Hyun;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.246-254
    • /
    • 2013
  • Some characteristics of nitrogen-water slug flow were optically measured, in vertical acrylic tubes of 2, 5 and 8 mm diameter. Bubble velocity, bubble and unit cell lengths were measured, by analyzing the light intensity signals from two sets of dot laser-infrared sensor modules mounted along the transparent tubes. Optical images of the bubbles were also taken and analyzed, to measure bubble shapes and liquid film thickness. It was found that the measured bubble velocities were in good agreement with the empirical models in the literature, except for those measured under high superficial velocity condition in the 2 mm tube. Bubble length was found to be the longest in the 2 mm tube, being 4 to 5 times those of the other tubes. Liquid film was found to have developed early in the 2 mm tube, which made the blunt shape of the bubble head. Liquid film thickness in the 8 mm tube was measured at almost twice those of the other tubes.

Long Distance Identification of Water and Oil using an Ultraviolet Fluorescence Measurement System (원거리의 물과 오일을 구별할 수 있는 UV형광측정시스템 개발과 분석에 대한 연구)

  • Baek, Kyung-hoon;Lee, Joon-seok;Jeon, Su-jeong;Park, Bo-ram;Park, Seong-wook
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.266-270
    • /
    • 2022
  • Owing to the rising volume of seaborne trade, oil spills damage the marine environment for over 250 yearly. Thus, various analysis methods such as the Fourier-transform infrared (FTIR), Raman spectroscope, and gas chromatography are used to monitor oil spills at sea, but these methods are expensive. Recently, to reduce operational costs, an underwater fluorometer was adopted. However, this approach is not ideal for the remote sensing of oil spills because the device gets submerged in the sea. In this study, we have designed and developed a monitoring system that uses ultraviolet fluorescence to detect spilled oil or water from a distance, as well as proposed an analyzing method defining based on water Raman signal and QF535. Each fluorescence spectrum of water, oil (crude oil), and Bunker A was obtained using the system, and was calculated and analyzed from the spectrum individually. Based on the results of the analysis, we could successfully identity water and oil at a long distance.