• 제목/요약/키워드: Infrared diode

검색결과 123건 처리시간 0.026초

적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향 (The effect of infrared rays diode irradiation on collagen formation)

  • 김태곤;김영표;이호식;박용필;천민우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

Indocyanine Green을 이용한 광열 치료의 다종 우식원성 바이오필름에 대한 효과 (Effect of Photothermal Therapy with Indocyanine Green in Multispecies Biofilm)

  • 김명환;박호원;이주현;서현우;이시영
    • 대한소아치과학회지
    • /
    • 제48권1호
    • /
    • pp.21-30
    • /
    • 2021
  • 이 연구의 목적은 indocyanine green (ICG)과 근적외선 diode 레이저의 사용이 다종 우식원성 바이오필름에 미치는 항균 효과를 조사하는 것이다. Streptococcus mutans, Lactobacillus casei, Candida albicans를 포함하는 다종 바이오필름이 ICG와 808 nm 근적외선 diode 레이저를 사용하여 서로 다른 조사 시간에 따라 처리되었다. Colony-forming unit (CFU)을 측정하였고, 바이오필름의 정성적 평가를 위해 공초점 레이저 주사 현미경(Confocal laser scanning microscopy, CLSM) 관찰을 시행하였다. 또한 광열 치료의 효과를 평가하기 위해 온도 측정이 시행되었다. ICG와 근적외선 diode 레이저를 사용한 군에서 CFU의 감소량이 통계적으로 유의하였으나, L. casei와 C. albicans에서는 시간에 따른 항균 효과의 유의한 차이는 관찰되지 않았다. CLSM 관찰에서도 유사한 세균 감소를 확인할 수 있었다. ICG와 근적외선 diode 레이저를 사용한 군은 ICG 없이 광조사를 시행한 군보다 더 높은 온도 상승을 보였으며, 측정된 온도는 열 치료의 온도 범위와 유사하였다. 결론적으로, ICG와 근적외선 diode 레이저는 다종 우식원성 바이오필름에 항균 효과를 보였다. 우식 예방을 위한 보조 수단으로 사용될 가능성을 가지나, 임상적인 적용을 위해서는 적용 프로토콜에 관한 연구가 필요하다.

보청기 성능 향상을 위한 적외선 통신 모듈 (An Infrared Communication Module for the Enhancement of Hearing Aids)

  • 박성모
    • 스마트미디어저널
    • /
    • 제7권3호
    • /
    • pp.29-34
    • /
    • 2018
  • 본 논문은 주변 소음이 많은 환경에서 보청기 수신 성능 향상을 위하여 적외선을 이용한 광통신 기술을 접목시키는 연구이다. 마이크로폰과 적외선 발광 다이오드를 포함하는 송신 모듈에서 음성신호를 적외선 광 신호로 변환시켜 공기 중에 내보내고, 일정 거리 떨어진 곳에 위치한 수신 모듈에서 적외선 신호를 수신하여 전기 신호로 변환하여 디지털 보청기의 입력 단에 전달한다. 특별히 수신 모듈은 보청기에 부착되어야 하므로 소형이며 저전압이고 저전력 소모가 바람직하다. 디지털 변조 방식과 아날로그 무변조 방식의 적외선 통신 기술을 적용하여 실험한 결과 실내에서 약 5미터 거리의 적외선 통신은 아날로그 무변조 방식이 적합함을 보였다. 송신 모듈과 수신 모듈 시제품을 제작하여 디지털 보청기에 연결하고 내부 파라미터를 조정하여 음성 신호를 정상 송수신함을 확인하였다.

NIR DIODE ARRAY SPECTROMETERS ON AGRICULTURAL HARVEST MACHINES OVERVIEW AND OUTLOOK

  • Rode, Michael
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1172-1172
    • /
    • 2001
  • Compact Near Infrared Diode Array Spectrometers offer new possibilities for on line quality assurance in the agricultural sector. Due to their speed and complete robustness towards temperature fluctuations and mechanical shock Diode Array Spectrometers are suitable for the use on Agricultural Harvest Machines. The growing consumer consciousness of food quality in combination with falling manufacturing prices demands procedures for an effective quality control system. The various conventional types of NIR instruments which have so far been used in laboratories are unsuitable for mobile applications under the rough conditions of field cropping not only because of their slow speed of measurement but also because of their shock sensitive filter wheels and monochromators necessary for fractionating polychromatic light. Another advantage of the on line use is the reduction of the sampling error because of the continuously measurement of the whole product. Considering the large economic importance of the dry matter content on agricultural products it is of particular advantage that water belongs to those constituents which are most easily assessed in the near infrared. While other constituents of economic importance such as starch, oil and protein in grains and seeds have a much lesser effect on NIR signals, their contents can nonetheless be assessed with high analytical precision on freshly harvested grains and seeds. In the last years several applications for on line quality assessment on harvesting machines were developed and tested. The talk will give an overview and outlook on existing and future possibilities of this new field of NIR applications.

  • PDF

LED IT 기반 시스템 센서 네트워크 송수신 모듈 연구 (LED IT-based System sensor network transceiver module research)

  • 장태수;이준명;최정원;김용갑
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.11-12
    • /
    • 2012
  • 본 논문에서는 LED(Light Emitting Diode)조명을 통해 기존 사용되는 적외선 센서로 가시광통신의 기술이 효율적으로 송 수신 가능한지 성능 분석을 하기 위한 연구이다. LED는 전기를 빛으로 바꾸는 성질을 이용하여 조명으로 활용한다. LED 조명 통신 융합 원리는 LED와 PD(Photo Diode)의 깜박임 송수신을 기본 원리로 하여 조명 기능을 유지하면서 통신에서 동시에 실현하게 가능하게 한다. LED의 기본 구조 하에 여러 IT 응용기술이 발전하게 되었고, 현재 실생활에 접하게 되었다. LED조명이 있는 곳이라면 어디서나 무선 통신을 할 수 있는 기술을 하고자, 널리 이용되고 있는 PD인 적외선 센서를 활용하여 시스템의 H/W의 초기 값을 ~1m 이상으로 하고 전체 시스템 속도 향상 시킬 수 있는 가시광 데이터 전송 시스템을 이루었다. 사용된 LED모듈이 통신에 가능한지 성능 분석을 하고, 구현된 연구의 LED 및 적외선 센서를 구성하여 예측 및 통신 거리에 대해 나타내고 응용방법과 가능성에 대해 연구하고자 한다.

  • PDF

APPLICATION OF A MULTI-WAVELENGTH NIR DIODE LASER ARRAY FOR NON-DESTRUCTIVE FOOD ANALYSIS

  • Tauscher, Bernhard;Butz, Peter;Lindauer, Ralf
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3123-3123
    • /
    • 2001
  • Near infrared (NIR) spectroscopy has become a widely used method in food and beverage analysis because of its speed, accuracy and the simplicity of sample preparation. One of the basic requirements of NIR instruments is a wide dynamic range if weak, or small, absorption changes or concentrations are to be measured. Thus the instrument must be sufficiently luminous, and efficient, to enable measurements to be made in a reasonably short time, as for some applications (e.g. sorting) short response times are essential. Diode lasers function the same way as lasers but linewidths are not as narrow as typical lasers. In this work an array of seven laser diodes (in the range of 750-1100 nm) with energy outputs of around hundred milliwatts each were combined with a fast diode array spectrometer (400-1100 nm, 1024 pixels, integration time from 3 ms) as detector. Measurements in transmission mode were performed in solutions of sugars in aqueous solutions and in deuteriumoxide. The feasibility of non-destructive measurements in transmission mode was investigated for different fruits and vegetables.

  • PDF

Monitoring of Environmental Arsenic by Cultures of the Photosynthetic Bacterial Sensor Illuminated with a Near-Infrared Light Emitting Diode Array

  • Maeda, Isamu;Sakurai, Hirokazu;Yoshida, Kazuyuki;Siddiki, Mohammad Shohel Rana;Shimizu, Tokuo;Fukami, Motohiro;Ueda, Shunsaku
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권12호
    • /
    • pp.1306-1311
    • /
    • 2011
  • Recombinant Rhodopseudomonas palustris, harboring the carotenoid-metabolizing gene crtI (CrtIBS), and whose color changes from greenish yellow to red in response to inorganic As(III), was cultured in transparent microplate wells illuminated with a light emitting diode (LED) array. The cells were seen to grow better under near-infrared light, when compared with cells illuminated with blue or green LEDs. The absorbance ratio of 525 to 425 nm after cultivation for 24 h, which reflects red carotenoid accumulation, increased with an increase in As(III) concentrations. The detection limit of cultures illuminated with near-infrared LED was 5 ${\mu}g$/l, which was equivalent to that of cultures in test tubes illuminated with an incandescent lamp. A near-infrared LED array, in combination with a microplate, enabled the simultaneous handling of multiple cultures, including CrtIBS and a control strain, for normalization by the illumination of those with equal photon flux densities. Thus, the introduction of a near-infrared LED array to the assay is advantageous for the monitoring of arsenic in natural water samples that may contain a number of unknown factors and, therefore, need normalization of the reporter event.

630nm Light Emitting Diode 모듈의 레벨 특성 평가 (Analysis of Level Characteristics of 630nm Light Emitting Diode Module)

  • 김태곤;천민우;박용필;김성환;송창훈;김영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.347-348
    • /
    • 2006
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. The equipment have been manufactured by using the High Bright Light Emitting Diode and TLC5941 integrated circuit. As a result, 630nm Light Emitting Diode Module was made for the optimization of irradiation condition. And we confirmed the current change according to increase of the level of Light Emitting Diode Module.

  • PDF

Compositional analysis by NIRS diode array instrumentation on forage harvesters

  • Andreashaeusler, Michael Rode;Christian, Paul
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1619-1619
    • /
    • 2001
  • Ourwork aims to assess the content of dry matter, protein, cell wall parameters and water soluble carbohydrates in forages without having to handle samples, transport them to a laboratory, dry, grind and chemically analyze them. for this purpose, the concept of fresh forage analysis under field conditions by means of compact integrated NIRS InGaAs-diode array instruments on small plot harvesters is being evaluated for plant breeding trials. This work was performed with the world first commercial experimental forage plot harvester equipped with a NIRS module for the collection, compression, and scanning of forage samples (including automatic referencing and dark current measure ments). It was used for harvesting and analyzing a number of typical forage grass and forage legume plot trials. After NIRS measurements in the field each sample was again analyzed in the laboratory by means of a conventional grating spectrometer equipped with Si-and PbS-detectors. Conventional laboratory analysis of the samples was restricted to dry matter (DM) content by means of oven drying at 105. Routine chemometric procedures were then employed to assess the comparative accuracy and precision of the DM assessments in the spectral range between 950 and 1650nm by the NIRS diode array as well as by the conventional NIRS scanning instrument. The results of this study confirmed that the type of NIRS diode array instrument employed here functioned well even in rugged field operations. further refinements proved to be necessary for optimizing the automatic filling of the sample compartment to adjust for the wide variation in forage material under conditions of extremely low or high harvest yields. The error achieved in calibrating the apparatus for forages of typical DM content proved to be satisfactory (SECV < 1.0). Possibly as a consequence of higher sampling errors, its performance in atypical forages with elevated DM contents was less satisfactory. The error level obtained on the conventional grating NIR spectrometer was similar to that of the diode array instrument for both types of forage.

  • PDF

휴대용 분광분석기를 이용한 알코올 중에 함유되어 있는 물의 측정 (Determination of water content in alcohol by portable near infrared (NIR) system)

  • 안지원;우영아;김효진
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.95-101
    • /
    • 2003
  • 본 연구에서는 근적외선 분광분석법 (NIR)을 이용하여 메탄올과 에탄올 혼합액 중의 물의 함량을 비파괴적으로 측정하였다. Photo-diode array 방식의 휴대용 NIR system과 scanning 방식의 NIR spectrometer를 이용하여 두 기기 사이의 calibration 결과를 비교하였다. 알코올 혼합액 중의 물의 함량을 정량분석 하기 위해 부분최소자승회귀분석법 (PLSR : partial least squares regression)을 사용하였다. 그 결과 SEP (standard error of prediction)가 photo-diode array 방식을 사용하였을 때는 0.10%, scanning 방식을 사용하였을 때는 0.12%였다. Calibration 모델의 안정성을 확인하기 위하여 6일 동안 2%의 메탄올을 함유하고 있는 에탄올 용액 중의 물의 함량이 3%, 5% 및 7% 되도록 시료를 조제하여 측정하였다. 두 가지 방식의 NIR 모두 3%이내의 변동계수 (CV : coefficient of variation)로 좋은 결과를 나타내었다. 이번 연구를 통해서 메탄올과 에탄올 혼합액 중의 물의 함량 측정이 근적외선 분광분석법을 이용하여 성공적으로 수행되었고 photo-diode array 방식의 휴대용 NIR 시스템을 이용해서 scanning 방식의 NIR spectrometer를 이용한 결과와 유사한 결과를 얻을 수 있었다.