• 제목/요약/키워드: Infrared analysis system

검색결과 432건 처리시간 0.031초

적외선 LED 랜드마크를 이용한 보행분석 시스템 (Gait Analysis System Using Infrared LED Landmarks)

  • 도치웃;서영수
    • 제어로봇시스템학회논문지
    • /
    • 제17권7호
    • /
    • pp.641-646
    • /
    • 2011
  • A low cost gait analysis system, which can measure stride length, walking speed, and ground reaction force, is proposed. A gait analysis system is used for medical evaluation of patients and rehabilitation assistance. Low cost cameras are attached to a shoe and movement of a shoe is estimated using infrared LED landmarks. Ground reaction force is measured from pressure sensors, which are installed inside a shoe. Through experiments, it is shown that the proposed system can be used to obtain stride length, walking speed, and ground reaction force.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

운전자 눈 위치를 이용한 사이드미러와 룸미러 자동조절시스템 (Automatic Side Mirror and Room Mirror Adjustment System using 3D Location of Driver′s Eyes)

  • 노광현;박기현;한민홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.7-7
    • /
    • 2000
  • This paper describes a mirror control system that can adjust the location of side and room mirror of the vehicle automatically using 3D coordinates to monitor the location of driver's eyes. Through analysis of the image inputted by two B/W CCD camera and infrared lamps installed on top of the driver's dashboard, we can estimate the values of 3D coordinate of the driver's eyes. Using these values, this system can determine the absolute position of each mirror and activate each actuator to the appropriate position. The stereo vision system can detect the driver's eyes whether it is day or night by virtue of infrared Lamps. We have tested this system using 10 drivers who drive a car currently, and most of the drivers were satisfied with the convenience of this system.

  • PDF

ANALYTICAL APPLICATIONS OF NEW PORTABLE NEAR INFRARED (NIR) SPECTROMETER SYSTEM

  • Ahn, Jhii-Weon;Kang, Na-Roo;Lim, Hung-Rang;Lee, Jung-Hun;Woo, Young-Ah;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1122-1122
    • /
    • 2001
  • A compact and handhold near infrared (NIR) system using microspectrometer was developed. This system was suitable not only in the laboratory, but also in the field or in the process. This system was first applied for classification of geographical origin of herbal medicine such as ginseng and sesame. To identify the origin of ginseng on site, the portable NIR system is more suitable for real field application. For this study, using the compact NIR system, soft independent modeling of class analogies (SIMCA) with 1100-1750 nm NIR spectra was utilized for classification of geographical origin (Korea and China) of both ginseng and sesame. The accuracy of results is more than 90%. Quantitative analysis for petroleum such as toluene, benzene, tri-methyl benzene, and ethyl benzene was performed with partial least squares (PLS) regression with NIR 1100-1750 nm spectra. This study showed that the NIR method and gas chromatography (GC), which is a standard method, have good correlations. Furthermore, the ash content of Cornu Cervi Parvum was analyzed and the accuracy was confirmed by the developed compact NIR system.

  • PDF

Development of the Near Infrared Camera System for Astronomical Application

  • 문봉곤
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

항공기 비행환경에 따른 플룸 IR 신호 영향성 연구 (Computational Investigation of the Effect of Various Flight Conditions on Plume Infrared Signature)

  • 김준영;전수환;명노신;김원철
    • 한국항공우주학회지
    • /
    • 제41권3호
    • /
    • pp.185-193
    • /
    • 2013
  • 항공기 추진 시스템의 IR(infrared; 적외선) 피탐지성 감소 연구를 위해 비행 환경에 따른 플룸 IR 신호의 영향성을 연구하였다. 이를 위해 가상의 아음속 무인기를 선정하고, 임무분석 및 성능 해석을 통해 엔진을 결정한 후 전체 임무를 만족시키는 노즐을 설계하였다. 압축성 CFD 코드를 이용하여 다양한 비행고도와 속도에 따른 열유동장 해석을 수행하였다. 열유동장 해석 결과를 바탕으로 narrow-band 모델을 기반으로 하여 항공기 후방 동체 플룸 IR 신호를 계산하였다. 다양한 비행조건에 따른 플룸 IR 신호를 분석하여 항공기 플룸 IR 신호 특성에 관한 정성적 정보를 도출하였다.

Infrared Thermography Quantitative Diagnosis in Vibration Mode of Rotational Mechanics

  • Seo, Jin-Ju;Choi, Nam-Ryoung;Kim, Won-Tae;Hong, Dong-Pyo
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.291-295
    • /
    • 2012
  • In the industrial field, real-time monitoring system like a fault early detection is very important. For this, the infrared thermography technique as a new diagnosis method is proposed. This study is focused on the damage detection and temperature characteristic analysis of ball bearing using the non-destructive infrared thermography method. In this paper, thermal image and temperature data were measured by a Cedip Silver 450 M infrared camera. Based on the results, the temperature characteristics under the conditions of normal, loss lubrication, damage, dynamic loading, and damage under loading were analyzed. It was confirmed that the infrared technique is very useful for the detection of the bearing damage.

항공기 후방동체 열유동장 및 IR 신호 예측 시스템 (Computation of Flowfield and Infrared Signature in Aircraft Exhaust System for IR Reduction Design)

  • 문혁;양영록;전수환;최성만;명노신;조태환
    • 한국항공우주학회지
    • /
    • 제39권7호
    • /
    • pp.652-659
    • /
    • 2011
  • 항공기 IR(Infrared; 적외선) 피탐지성 감소 연구를 위해 후방동체 주위 열유동장과 IR 신호를 예측하는 시스템을 구축하였다. 아음속 무인전투기(UCAV)를 대상 항공기로 고려하여 가상 임무 설정 및 성능해석을 통해 가상 엔진을 선정하였다. 또한 각 임무를 만족시키는 노즐을 설계한 후, 고속 고온 열유동장 CFD 해석코드를 이용하여 최대 출력에서의 노즐 내부 유동을 해석하였다. 예측된 노즐 표면 및 후방 동체의 온도는 고체표면 복사 열교환 및 신호 예측코드와 연계시키는 시스템과 연동시켜 최종적으로 IR 신호를 계산하였다. IR 밴드 및 관찰 각도에 대한 IR 신호의 변화를 분석하여 IR 감소설계를 위한 정성적 정보를 도출하였다.

적외선 검출기 개발가능성 및 대안분석 연구 (A Study on Feasibility Analysis and Alternatives for Infrared Detector Development)

  • 민성기;김철환;김경수
    • 시스템엔지니어링학술지
    • /
    • 제1권1호
    • /
    • pp.1-13
    • /
    • 2005
  • The purpose of this paper analyze development feasibility and alternatives for infrared detector development in both technology and cost. Infrared Detector is core component of Thermal Imaging System and developed by ADD from 2006 10 2008 year. We got raw input data from development and technical expert, and then analyze cost and technology for development feasibility, and alternatives study. Technology level is analyzed by TRL(Technology Readiness Level) and AOA(Analysis of Alternatives) is done by development cost estimate. Estimating the development cost, we use SEER-H that is parametric cost estimating tool based on Knowledge Base. This study can help those who are related to the cost and development feasibility analysis of other weapon systems.

  • PDF

적외선 카메라 KAONICS의 열해석 (A STUDY OF THERMAL ANALYSIS OF KAONICS)

  • 강지나;이성호;진호;박수종;문봉곤;김상호;박장현
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권4호
    • /
    • pp.467-480
    • /
    • 2004
  • KAONICS(KAO Near Infrared Camera System)와 같은 적외선 카메라는 열잡음제거가 매우 중요하다. 입사창을 통해 들어오는 외부의 열복사 이외에도 카메라의 외벽을 통해 유입되는 열복사가 배경복사로서 검출기에 입사하여 시스템의 성능을 저하 시키며 그 양은 무시할 수 없다. 따라서 배경복사와 검출기 자체의 열잡음을 줄이기 위해서 카메라 내부의 광학계 전체와 검출기를 냉각해야만 한다. 이에 본 연구에서는 J, H, Ks, L 파장 대를 관측하기 위한 내부 냉각온도를 정량적으로 결정하였으며 카메라 외부에서 유입되는 복사량을 추산하고 냉각에 필요한 냉각 열용량을 추정하여 냉각기를 선택하였다. 선택된 냉각기를 이용하여 냉각할 때 Cold-Box가 목표온도에 도달하는 시간과 최종 냉각 온도를 계산하여 시스템 제작에 반영하였다.