• 제목/요약/키워드: Infrared Thermal Image Analysis

검색결과 95건 처리시간 0.025초

적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가 (Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis)

  • 문종필;윤남규;이성현;김학주;이수장;김영화
    • 한국농공학회논문집
    • /
    • 제52권2호
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

위성영상을 통한 서울시 지표온도 분석 (The Land Surface Temperature Analysis of Seoul city using Satellite Image)

  • 정종철
    • 환경영향평가
    • /
    • 제22권1호
    • /
    • pp.19-26
    • /
    • 2013
  • The propose of this study is to analyze the optimum spatial resolution of the urban spatial thermal environment structure and to evaluate of the possibility detection using aerial photographs and thermal satellite images. The proper techniques of the optimum spatial resolution for the urban spatial thermal environment structure were analyzed. Thermal infrared satellite image of Seoul city were used for the change rate of surface temperature variation and suggested to the spatial extent and effects of urban surface characteristics and spatial data was interpreted as regions. To extract the surface temperature, Landsat thermal infrared satellite image compared with an automatic weather station data and in the field of the measured temperature and surface temperature by thermal environment affects, the spatial domain has been verified. The surface temperature of the satellite images to extract after adjusting surface temperature isotherms were constructed. The changes in surface temperature from 2008 to 2012 the average surface temperature observation images of changing areas were divided into space. The results of this study are as follows: Through analysis of satellite imagery, Seoul city surface temperature change due to extraction comfort indices were classified into four grades. The comfort index indicative of the temperature of Gangnam-gu, $23.7{\sim}27.2(^{\circ}C)$ range and Songpagu, a $22.7{\sim}30.6(^{\circ}C)$ respectively, the surface temperature of Yeouido $25.8{\sim}32.6(^{\circ}C)$ were in the range.

FFT를 이용한 화재 열영상의 주파수 스펙트럼 분석 (A Frequency Spectrum Analysis based on FFT of Fire Thermal Image)

  • 김원호;장복규
    • 융합신호처리학회논문지
    • /
    • 제12권1호
    • /
    • pp.33-37
    • /
    • 2011
  • 본 논문은 FFT를 이용한 적외선 화재 열영상의 주파수 스펙트럼 분석에 관한 것으로 영상처리를 통하여 화재 발생 유무를 주파수 영역에서 판별하기 위한 조건을 도출하는 것이 목적이다. 적외선 열영상의 주파수 스펙트럼 분석은 고속 푸리에 변환을 이용하여 수행하였으며, 화재로 추정되는 고명도의 영역을 화재 후보영역으로 결정한 다음, 연속적인 열영상의 해당영역에 대하여 DC 및 AC 주파수 분포를 분석하였다. 분석된 결과를 기반으로 정적인 오검출 요소와 동적특성을 가지는 화재영역을 구분하는 열영상의 화재 판정 기준을 제시하고 컴퓨터 모의실험을 통하여 실용성을 확인하였다.

적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석 (Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image)

  • 조재완;홍석붕;구인수
    • 제어로봇시스템학회논문지
    • /
    • 제17권12호
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

Retinex 처리에 기반한 적외선 열상 이미지의 화질 개선 (Thermal Infrared Image Enhancement Method Based on Retinex)

  • 이원석;김경희;이상원
    • 전자공학회논문지 IE
    • /
    • 제48권2호
    • /
    • pp.32-39
    • /
    • 2011
  • 비냉각형 적외선 검출기를 사용한 적외선 열상 카메라의 영상은 다이나믹 레인지가 좁고 신호 증폭에 의한 노이즈로 인하여 피사체를 식별하기 어려운 단점이 있다. 인간의 시각모델을 기반으로 한 레티넥스 알고리즘은 콘트라스트 향상 및 컬러 재현성에 있어서 매우 효과적인 방법으로 알려져 있다. 하지만, 적외선 열상 이미지와 같이 다이나믹 레인지가 좁은 영상에 레티넥스 알고리즘을 적용할 경우 오히려 콘트라스트가 감소하고 이미지 품질이 저하된다. 본 논문에서는 적외선 열상 이미지의 특성에 적합한 레티넥스 알고리즘 기반의 화질 개선 방법을 제안한다. 콘트라스트 개선 성능을 향상시키기 위해 새로운 다이나믹 레인지 압축 함수를 사용하였고, 국부적인 윤곽과 노이즈를 개선하기 위해 콘트라스트 보상 처리를 영상의 합성 과정에 적용하였다. 실험 결과 영상의 비교와 분석을 통해 제안한 알고리즘이 기존의 알고리즘보다 적외선 열상 이미지의 화질 개선에 더 효과적인 방법임을 확인하였다.

치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석 (Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine)

  • 강후원;박영식;황인;이창호;허용;원용관
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.

적외선 열화상 카메라용 캘리브레이션 타겟 개발 (Development of Calibration Target for Infrared Thermal Imaging Camera)

  • 김수언;최만용;박정학;신광용;이의철
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.248-253
    • /
    • 2014
  • 카메라 영상 캘리브레이션은 머신비전과 같은 비전검사기술분야에서 영상으로부터 기하학적 정보를 정확하게 추출하고자 할 때 정확성을 높이는데 필요한 매우 중요한 과정이다. 그러나 기존에 가시광 카메라에 사용되던 캘리브레이션 타겟은 중적외선, 원적외선 열화상 카메라에 적용하기 어렵다. 최근에 적외선 열화상카메라를 이용한 결함측정기술이 많이 사용되면서 적용할 수 있는 캘리브레이션 타겟 개발이 요구되고 있다. 따라서 본고에서는 유한요소 열전달 해석을 이용하여 가시광 카메라와 적외선 열화상카메라 모두에 적용 가능한 캘리브레이션 타겟을 제안하였다. 개발된 캘리브레이션 타겟을 열화상카메라와 가시광 카메라로 촬영하여 비교실험 하였으며, 실험결과 제안된 캘리브레이션 타겟의 효율성을 보여준다.

적외선 열화상 카메라를 이용한 머시닝 센터 주축 열변위에 관한 열해석 (Thermo-Analysis of Machining Center Main-Axis Thermo-Displacement for Infrared Rays Thermo-Image Camera)

  • 김재열;윤성운;임노빈;유신;마상동;양동조;송인석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.125-130
    • /
    • 2001
  • Diagnosis or measurements using Infrared thermo-image hasn t been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermo-vision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the machining center main-axis process.

  • PDF

초점면 배열 방식의 열상카메라 시스템의 구현 (Implementation of a Thermal Imaging System with Focal Plane Array Typed Sensor)

  • 박세화;원동혁;오세중;윤대섭
    • 제어로봇시스템학회논문지
    • /
    • 제6권5호
    • /
    • pp.396-403
    • /
    • 2000
  • A thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main part of the system is a thermal camera in which a focal plane array typed sensor is introduced. The sensor detects the mid-range infrared spectrum of target objects and then it outputs a generic video signal which should be processed to form a frame thermal image. Here, a digital signal processor(DSP) is applied for the high speed processing of the sensor signals. The DSP controls analog-to-digital converter, performs correction algorithms and outputs the frame thermal data to frame buffers. With the frame buffers can be generated a NTSC signal and transferred the frame data to personal computer(PC) for the analysis and a monitoring of the thermal scenes. By performing the signal processing functions in the DSP the overall system achieves a simple configuration. Several experimental results indicate the performance of the overall system.

  • PDF