• 제목/요약/키워드: Infrared Temperature Sensor

검색결과 229건 처리시간 0.031초

가변 파장형 적외선 센서를 이용한 변압기 결함 진단 (Fault Analysis of Transformer using Tunable Infrared Gas Sensors)

  • 이근호;이승환
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.55-61
    • /
    • 2023
  • The objective of this study is to determine the concentrations of mixed gases by establishing a diagnosis method of a transformer using tunable-wavelength optical infrared sensors. Absorption of infrared light by methane, acetylene, and ethylene gases injected is measured from the outputs of the infrared sensors. Regression analysis equations of the gas concentrations are acquired from their respective measured absorption. The obtained concentrations are as follows: -3-9 % errors above 600 ppm(methane), 3 % errors above 1200 ppm(acetylene), and 10 % errors above 500 ppm(ethylene). The concentration inference equations obtained using the individual gases are applicable when the absorption wavelength bands do not overlap. The results of the fault analysis of a transformer using the Duval triangle method and the tunable infrared gas sensors are as follows: temperature faults with -1-1% errors and energy faults with -7-7 % errors.

적외선 감지 자동격발장치의 설계 (Design of an Automatic Target Sensing and Triggering System)

  • 홍성한;김권희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1719-1723
    • /
    • 2005
  • An automatic target sensing and triggering system for small fire arms is proposed. The system consists of an optical collector, an infrared ray sensor responsive to human body temperature, an electric actuator and a trigger mechanism. TRIZ methodologies are used to develop solutions to several contradictory problems. Experimental results on the system performance is compared with predictions.

  • PDF

이동식 적외선 가스히터의 배기가스현상에 대한 실험적 연구 (Experimental Study on the Flue Gas Phenomena in Infrared Mobile Heaters)

  • 김영규;류근준
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.119-125
    • /
    • 1996
  • The experimental work is performed to obtain content levels and characteristics of flue gas in infrared mobile heaters for butane gas with varying the chamber size and its room temperature. The results showed that the oxygen depletion sensor device is operated at 18.3% of oxygen content. And the relation of oxygen content and carbon dioxide content in an enclosed space show linear aspect, but the content rate of carbon monoxide occurs at random without the level of oxygen content and carbon dioxide content.

  • PDF

Micromachined ZnO Piezoelectric Pressure Sensor and Pyroelectric Infrared Detector in GaAs

  • Park, Jun-Rim;Park, Pyung
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.239-244
    • /
    • 1998
  • Piezoelectric pressure sensors and pyroelectric infrared detectors based on ZnO thin film have been integrated with GaAs metal-semiconductor field effect transistor (MESFET) amplifiers. Surface micromachining techniques have been applied in a GaAs MESFET process to form both microsensors and electronic circuits. The on-chip integration of microsensors such as pressure sensors and infrared detectors with GaAs integrated circuits is attractive because of the higher operating temperature up to 200 oC for GaAs devices compared to 125 oC for silicon devices and radiation hardness for infrared imaging applications. The microsensors incorporate a 1${\mu}$m-thick sputtered ZnO capacitor supported by a 2${\mu}$m-thick aluminum membrane formed on a semi-insulating GaAs substrate. The piezoelectric pressure sensor of an area 80${\times}$80 ${\mu}$m2 designed for use as a miniature microphone exhibits 2.99${\mu}$V/${\mu}$ bar sensitivity at 400Hz. The voltage responsivity and the detectivity of a single infrared detector of an area 80${\times}$80 $\mu\textrm{m}$2 is 700 V/W and 6${\times}$108cm$.$ Hz/W at 10Hz respectively, and the time constant of the sensor with the amplifying circuit is 53 ms. Circuits using 4${\mu}$m-gate GaAs MESFETs are fabricated in planar, direct ion-implanted process. The measured transconductance of a 4${\mu}$m-gate GaAs MESFET is 25.6 mS/mm and 12.4 mS/mm at 27 oC and 200oC, respectively. A differential amplifier whose voltage gain in 33.7 dB using 4${\mu}$m gate GaAs MESFETs is fabricated for high selectivity to the physical variable being sensed.

  • PDF

Derivation of Surface Temperature from KOMPSAT-3A Mid-wave Infrared Data Using a Radiative Transfer Model

  • Kim, Yongseung
    • 대한원격탐사학회지
    • /
    • 제38권4호
    • /
    • pp.343-353
    • /
    • 2022
  • An attempt to derive the surface temperature from the Korea Multi-purpose Satellite (KOMPSAT)-3A mid-wave infrared (MWIR) data acquired over the southern California on Nov. 14, 2015 has been made using the MODerate resolution atmospheric TRANsmission (MODTRAN) radiative transfer model. Since after the successful launch on March 25, 2015, the KOMPSAT-3A spacecraft and its two payload instruments - the high-resolution multispectral optical sensor and the scanner infrared imaging system (SIIS) - continue to operate properly. SIIS uses the MWIR spectral band of 3.3-5.2 ㎛ for data acquisition. As input data for the realistic simulation of the KOMPSAT-3A SIIS imaging conditions in the MODTRAN model, we used the National Centers for Environmental Prediction (NCEP) atmospheric profiles, the KOMPSAT-3Asensor response function, the solar and line-of-sight geometry, and the University of Wisconsin emissivity database. The land cover type of the study area includes water,sand, and agricultural (vegetated) land located in the southern California. Results of surface temperature showed the reasonable geographical pattern over water, sand, and agricultural land. It is however worthwhile to note that the surface temperature pattern does not resemble the top-of-atmosphere (TOA) radiance counterpart. This is because MWIR TOA radiances consist of both shortwave (0.2-5 ㎛) and longwave (5-50 ㎛) components and the surface temperature depends solely upon the surface emitted radiance of longwave components. We found in our case that the shortwave surface reflection primarily causes the difference of geographical pattern between surface temperature and TOA radiance. Validation of the surface temperature for this study is practically difficult to perform due to the lack of ground truth data. We therefore made simple comparisons with two datasets over Salton Sea: National Aeronautics and Space Administration (NASA) Jet Propulsion Laboratory (JPL) field data and Salton Sea data. The current estimate differs with these datasets by 2.2 K and 1.4 K, respectively, though it seems not possible to quantify factors causing such differences.

적외선 센서를 이용한 소 귀에서의 체온 측정 (The temperature measurement at external auditory meatus using Infrared sensor in cattle)

  • 김신자;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.401-404
    • /
    • 2008
  • 인간과 마찬가지로 가축도 체온의 변화로부터 질병의 유무를 판별할 수 있는 정보를 제공한다. 그 중 소의 경우, 유열, 중독, 설사, 식체, 만성장염, 감기, 폐렴, 탄저병 등의 질병을 예측 할 수 있다. 따라서 주기적으로 체온을 측정하고 분석함으로써 질병을 조기 발견하고 빠르게 대처하여 손실을 최소화 할 수 있는 가축용 체온 측정 시스템을 제안한다. 또한 이 시스템은 주기적인 자동 측정과 위험 상태 알림 기능을 갖추고 있으므로 줄어드는 인력에 대한 대안과 가축의 품질 관리에 유용하게 사용될 수 있을 것이다.

  • PDF

모터컨트롤센터의 BUS BAR 이상 감지를 위한 실험적 연구 (A study on sensing for abnormality of BUS BAR in motor control center)

  • 김성대
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5838-5842
    • /
    • 2011
  • 본 연구는 고용량의 모터를 구동하기 위한 모터컨트롤센터(MCC)의 내부 구조 중 각 상(R,S,T)의 BUS BAR의 온도와 BUS BAR 볼트 체결부의 온도변화가 모터컨트롤센터의 노후화 및 진동에 따라 어떠한 차이가 있는지를 적외선 온도센서가 설치된 온도측정용 2차원 기구부를 설계 제작하고 모터컨트롤센터의 내부에 설치하여 BUS BAR의 온도 및 전류 변화량을 상시 모니터링 하였다. 실험을 통하여 부하에 따른 BUS BAR의 온도 변화를 BUS BAR 나사 체결부위를 중심으로 측정하였으며, BUS BAR의 온도변화와 소모 전류에 대한 비례관계를 확인할 수 있었다. 또한 이러한 비접촉식 2차원 온도측정 시스템을 모터컨트롤센터 내부에 장착하면 부하의 과전류로 인한 온도 상승이나 접촉 불량 등으로 발생될 수 있는 정전이나 화재 사고를 예방할 수 있을 것으로 기대된다.

적외선 센서를 이용한 초음파 용착부의 마찰열 측정 (Temperature Measurement on Ultrasonic Weld Surfaces by Using an Infrared Sensor)

  • 김원호;강은지;민경탁
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.425-429
    • /
    • 2017
  • During ultrasonic welding, plastic deformation, elastic hysteresis, and friction generate heat at the contact portions of the two materials to be welded, theoretically analyzing and experimentally measuring the temperature at the welded part are very important for identifying the heat affected zone. However, the welding temperature during ultrasonic welding wherein welding is performed in less than a second is a challenge. We investigated the effects of welding conditions such as welding time, welding pressure, and the ultrasonic vibration amplitude of horns on the temperature of welded surface of a Ni sheet of thickness 0.1 mm. We used a horn with a resonance frequency of 40 kHz and an ultrasonic welder. The temperature was measured using a intrared sensor, and its characteristics were investigated. Experimental results showed that increase in welding time and pressure and ultrasonic vibration amplitude of horns generally caused the increase in surface temperature of the weld.

초음파 센서를 이용한 자동문의 물체인식 성능개선 (An Object Recognition Performance Improvement of Automatic Door using Ultrasonic Sensor)

  • 김기두;원서연;김희식
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.97-107
    • /
    • 2017
  • 자동문에 있어서 적외선과 마이크로파 센서는 물체인식 입력신호를 통해 모터 개폐동작 제어를 담당하는 핵심부품으로 많이 사용하고 있다. 적외선과 마이크로파 기반의 센서를 자동문에 적용한 기존 시스템 경우, 대부분 건물외부로 노출하여 설치하기 때문에 태양의 적외선 또는 가시광선에 의해 오동작이 발생하게 된다. 또한 실내 외의 온도 차로 인한 환경변화는 물체인식 검출신호에 잡음을 일으키는 원인이 되기도 한다. 이러한 문제점과 더불어 빠르게 이동하는 물체를 감지센서가 검출영역에 대한 처리속도를 따라가지 못하는 하드웨어 결함이 감지 사각지대를 만들게 된다. 이는 자동문을 이용하는 통행자의 안전문제에 직접적인 영향을 주고 있기 때문에 빠른 개선방안이 필요한 시점이다. 본 논문은 기존의 감지센서 외에 초음파 센서를 추가 설치하여 검출영역을 개선하기 위한 실험을 진행하였다. 초음파 신호의 검출특성과 장점을 자동문에 적용하여 빠르게 이동하는 물체의 접근경로와 고정 장애물의 위치영역을 정확하고 신속하게 처리하는 연산회로와 검출 알고리즘을 구현하였다. 이를 통해 초음파 센서를 적용한 자동문이 사각지대를 감지하는 검출영역에서 성능개선으로 이어지는 결과를 현장실험을 통해서 확인하고 개선방안을 제안하였다.

정전 용량을 이용한 비접촉식 엘리베이터 버튼 (The contactless elevator button using the electrostatic capacity)

  • 방걸원
    • 산업융합연구
    • /
    • 제19권6호
    • /
    • pp.67-72
    • /
    • 2021
  • 건물에 설치된 엘리베이터는 승강기 호출 버튼과 목적층으로의 선택을 위한 입력 버튼으로 구성되어 있다. 엘리베이터 버튼은 승강기를 이용하는 사람이 직접 눌러야 입력이 된다. 이러한 승객의 입력은 버튼의 오염으로 인해 전염병에 감염될 수 있다. 이러한 문제점을 해결하기 위한 수단으로 비접촉식 버튼이 요구되고, 이는 정전용량 방식을 적용하여 물체의 근접을 감지한다. 적외선 열감지 센서를 부착하여 인체의 체온을 측정하는 기능을 구현하고 UV-LED를 부착하여 버튼의 살균 기능을 제공한다. 물체가 없을 때의 출력파형을 측정하고 물체가 근접할 때의 출력 파형을 측정하여 버튼이 선택되고 적외선온도측정 센서를 통해 체온이 측정되며, 사용자가 없을 때 UV-LED를 점등하여 살균하였다. 비접촉식 엘리베이터 버튼은 전염병을 옮기는 바이러스의 감염을 방지할 수 있는 효과가 있고, 체온을 감지하여 CIVID 19의 양성 확진자를 선별할 수 있어 감염병 예방에도 효과가 있을 것으로 기대된다.