• Title/Summary/Keyword: Infrared Temp

Search Result 5, Processing Time 0.019 seconds

Thermo Physiological responses of Far Infrared Ray Radiation Fabrics at outdoor in summer (옥외에서 원적외선 방사직물 착용시 온열생리반응)

  • 송명견;안필자;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • This study was performed to define the effects of Far Infrared Ray Radiation Fabrics as summer garments during outdoor work by human trial. One healthy male subject was volunteered for this study. Experimental garments consisted of three kinds of trousers (Cotton, Cotton/linen blended, Far Infrared Ray Radiation Fabric/wool blended) and basic garments (panty, socks, shirts, and dress shirts). The measurements were rectal temp., skin temp., microclimate inside clothing, heart rate, subjective sensation etc. The results were as follows : 1. Rectal temperature showed the lowest in Far Infrared Ray Radiation Fabrics among 3 garments. 2. Skin temperature (forehead, chest abdomen temp.) and mean skin temperature were lower in Far Infrared Ray Radiation Fabrics than in others, especially during early stage of work. 3. Heart rate showed lower value in Far Infrared Ray Radiation Fabrics than in others but there was no significance among the garments. 4. Humidity inside clothing and total weight loss showed the highest value in Far Infrared Ray Radiation Fabrics.

  • PDF

DEGREE OF CONVERSION OF BIS-ACRYLIC BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Kim, Sung-Hun;Watts, David C.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.639-643
    • /
    • 2008
  • STATEMENT OF PROBLEM: The degree of conversion may influence the ultimate mechanical and physical properties of provisional crown and fixed partial denture materials. The high levels of the unreacted residual monomer may cause deleterious effect on the properties. PURPOSE: The purpose of this study was to measure the degree of conversion of bis-acrylic based provisional crown and fixed partial denture materials by using an infrared spectroscopic method. MATERIAL AND METHODS: Chemically activated three bis-acrylic based provisional crown and fixed partial denture materials, LuxaTemp [DMG, Hamburg, Germany], fast set TemPhase [Kerr, Orange, CA, USA] and Protemp 3 Garant [3M-ESPE, St Paul, MN, USA], were investigated by Fourier transform infrared spectrometry (FTIR). The FTIR spectra of the materials tested were immediately obtained after mixing. The specimens were stored under dry conditions and at $23^{\circ}C$ for 24 hours, and then the spectra of the materials were also obtained. The degree of conversion (%) was calculated from the spectrum of the absorbance between the aliphatic double bond at 1637 $cm^{-1}$ and the aromatic double bond at 1608 $cm^{-1}$ using the baseline method. The data were statistically analyzed using one-way ANOVA and the multiple comparison Scheffe test at the significance level of 0.05. RESULTS: The mean value and standard deviation of the degree of conversion were 52.5 % ${\pm}$ 1.1 %, 50.3 % ${\pm}$ 0.8 %, and 42.3 % ${\pm}$ 4.9 % for LuxaTemp, Protemp 3 Garant and fast set TemPhase, respectively. There was no significant difference between LuxaTemp and Protemp 3 Garant, whereas there was a statistically difference between Protemp 3 Garant and fast set TemPhase, and LuxaTemp and fast set TemPhase (P < .05). CONCLUSION: The degree of conversion of fast set TemPhase was significantly lower than those of the others. The degree of conversion may be correlated with the rate of polymerization.

Generation of Sea Surface Temperature Products Considering Cloud Effects Using NOAA/AVHRR Data in the TeraScan System: Case Study for May Data (TeraScan시스템에서 NOAA/AVHRR 해수면온도 산출시 구름 영향에 따른 신뢰도 부여 기법: 5월 자료 적용)

  • Yang, Sung-Soo;Yang, Chan-Su;Park, Kwang-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.165-173
    • /
    • 2010
  • A cloud detection method is introduced to improve the reliability of NOAA/AVHRR Sea Surface Temperature (SST) data processed during the daytime and nighttime in the TeraScan System. In daytime, the channels 2 and 4 are used to detect a cloud using the three tests, which are spatial uniformity tests of brightness temperature (infrared channel 4) and channel 2 albedo, and reflectivity threshold test for visible channel 2. Meanwhile, the nighttime cloud detection tests are performed by using the channels 3 and 4, because the channel 2 data are not available in nighttime. This process include the dual channel brightness temperature difference (ch3 - ch4) and infrared channel brightness temperature threshold tests. For a comparison of daytime and nighttime SST images, two data used here are obtained at 0:28 (UTC) and 21:00 (UTC) on May 13, 2009. 6 parameters was tested to understand the factors that affect a cloud masking in and around Korean Peninsula. In daytime, the thresholds for ch2_max cover a range 3 through 8, and ch4_delta and ch2_delta are fixed on 5 and 2, respectively. In nighttime, the threshold range of ch3_minus_ch4 is from -1 to 0, and ch4_delta and min_ch4_temp have the fixed thresholds with 3.5 and 0, respectively. It is acceptable that the resulted images represent a reliability of SST according to the change of cloud masking area by each level. In the future, the accuracy of SST will be verified, and an assimilation method for SST data should be tested for a reliability improvement considering an atmospheric characteristic of research area around Korean Peninsula.

Adjoint-Based Observation Impact of Advanced Microwave Sounding Unit-A (AMSU-A) on the Short-Range Forecast in East Asia (수반 모델에 기반한 관측영향 진단법을 이용하여 동아시아 지역의 단기예보에 AMSU-A 자료 동화가 미치는 영향 분석)

  • Kim, Sung-Min;Kim, Hyun Mee
    • Atmosphere
    • /
    • v.27 no.1
    • /
    • pp.93-104
    • /
    • 2017
  • The effect of Advanced Microwave Sounding Unit-A (AMSU-A) observations on the short-range forecast in East Asia (EA) was investigated for the Northern Hemispheric (NH) summer and winter months, using the Forecast Sensitivity to Observations (FSO) method. For both periods, the contribution of radiosonde (TEMP) to the EA forecast was largest, followed by AIRCRAFT, AMSU-A, Infrared Atmospheric Sounding Interferometer (IASI), and the atmospheric motion vector of Communication, Ocean and Meteorological Satellite (COMS) or Multi-functional Transport Satellite (MTSAT). The contribution of AMSU-A sensor was largely originated from the NOAA 19, NOAA 18, and MetOp-A (NOAA 19 and 18) satellites in the NH summer (winter). The contribution of AMSU-A sensor on the MetOp-A (NOAA 18 and 19) satellites was large at 00 and 12 UTC (06 and 18 UTC) analysis times, which was associated with the scanning track of four satellites. The MetOp-A provided the radiance data over the Korea Peninsula in the morning (08:00~11:30 LST), which was important to the morning forecast. In the NH summer, the channel 5 observations on MetOp-A, NOAA 18, 19 along the seaside (along the ridge of the subtropical high) increased (decreased) the forecast error slightly (largely). In the NH winter, the channel 8 observations on NOAA 18 (NOAA 15 and MetOp-A) over the Eastern China (Tibetan Plateau) decreased (increased) the forecast error. The FSO provides useful information on the effect of each AMSU-A sensor on the EA forecasts, which leads guidance to better use of AMSU-A observations for EA regional numerical weather prediction.

A Development of Non-Invasive Body Monitoring IOT Sensor for Smart Silver Healthcare (스마트 실버 헬스케어를 위한 비접촉 인체감지 IOT 센서 개발)

  • Kang, Byung Wuk;Kim, Sang Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • This paper is composed of a passenger management system using a temperature sensing module, a PIR sensor module for detecting movement inside a room, and a smart breath sensing module for determining a sleeping state. An embedded sensor module and a communication system integrated the sensing part and the algorithm driving part. As the aging society is accelerating and becoming more upgraded, the social cost of Silver Care increases, and in order to protect privacy, it is necessary to reduce costs by developing efficient smart silver care devices. The proposed non - image human body detection IOT sensor system is implemented by hardware and software and has superior performance compared with conventional image monitoring method.