• Title/Summary/Keyword: Infrared Reflection

Search Result 187, Processing Time 0.026 seconds

Oxidation behavior on the surface of titanium metal specimens at high temperatures (300~1000℃) (고온 (300~1000 ℃)에서 티타늄 금속시편의 표면 산화거동)

  • Park, Yang-Soon;Han, Sun-Ho;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.464-470
    • /
    • 2009
  • For the investigation of the oxidation behavior for titanium metal at various temperatures, titanium specimens were heated for 2 hours in the range of $300{\sim}1000^{\circ}C$, individually. And then X-ray diffraction(XRD), scanning electron microscopy (SEM)/energy dispersive spectroscopy (EDS) and attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopic analyses were carried out. At $300^{\circ}C$, infrared absorption bands on the surface of the titanium specimen were shown in a spectrum by the oxygen uptake of titanium metal(hexagonal). At increased temperature, not only infrared absorption bands but also X-ray diffraction peaks for the titanium oxide were grown and shifted to low wave number ($cm^{-1}$) and angle($^{\circ}$) due to the more oxygen diffusion into titanium metal. At $700^{\circ}C$, $Ti_3O$ (hexagonal phase) was identified by X-ray diffractometer. $TiO_2$ (rutile, tetragonal phase) layer was produced on the surface of the specimen below $1{\mu}m$ in thickness at $600^{\circ}C$, and grown about $2{\mu}m$ at $700^{\circ}C$ and with $110{\mu}m$ in thickness at $1000^{\circ}C$. Above $900^{\circ}C$, (110) plane of the crystal on the surface of rutile-$TiO_2$ layer was grown.

Identification of Advanced Argillic-altered Rocks of the Haenam Area, Using by ASTER Spectral Analysis (ASTER 분광분석을 통한 해남지역 강고령토변질 암석의 식별)

  • Lee, Hong-Jin;Kim, Eui-Jun;Moon, Dong-Hyeok
    • Economic and Environmental Geology
    • /
    • v.44 no.6
    • /
    • pp.463-474
    • /
    • 2011
  • The Haenam epithermal mineralized zone is located in the southwestern part of South Korea, and hosts low sulfidation epithermal Au-Ag deposit (Eunsan-Moisan) and clay quarries (Okmaesan, Seongsan, and Chunsan). Epithermal deposits and accompanying hydrothermal alteration related to Cretaceous volcanism caused large zoned assemblages of hydrothermal alteration minerals. Advanced argillic-altered rocks with mineral assemblages of alunite-quartz, alunite-dickite-quartz, and dickite-kaolinite-quartz exposed on the Okmaesan, Seongsan, and Chunsan area. Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), with three visible and near infrared bands, six shortwave infrared bands, and five thermal infrared bands, was used to identify advanced argillic-altered rocks within the Haenam epithermal mineralized zone. The distinct spectral features of hydrothermal minerals allow discrimination of advanced argillic-altered rocks from non-altered rocks within the study area. Because alunite, dickite, and kaolinite, consisting of advanced argillic-altered rocks within the study area are characterized by Al-O-H-bearing minerals, these acid hydrothermal minerals have a strong absorption feature at $2.20{\mu}m$. The band combination and band ratio transformation cause increasing differences of DN values between advanced argillic-altered rock and non-altered rock. The alunite and dickite-kaolinite of advanced argillic-altered rocks from the Okmaesan, Seongsan, and Chunsan have average DN values of 1.523 and 1.737, respectively. These values are much higher than those (1.211 and 1.308, respectively) of non-altered area. ASTER images can remotely provide the distribution of hydrothermal minerals on the surface. In this way good relation between ASTER spectra analysis and field data suggests that ASTER spectral analysis can be useful tool in the initial steps of mineral exploration.

Frequency Doubling in LiIO3 Crystals by the Ring Enhancement Cavity (고리형 증폭 공진기에 의한 LiIO3결정에서 제2조화파 발생)

  • Kim, Sang-Gee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.45-49
    • /
    • 1999
  • The second harmonic, wavelength is 397nm, of the continuous wave diode laser, whose maximum power is 35mW, was generated in $LiIO_3$ crystals in a ring enhancement cavity. 5mm- and 10mm-long crystals cut $43.21^{\circ}$ for optic axis were used in this experiment. Both surfaces of those were anti-reflection coated for 794nm. In case the crystal was inserted into the cavity, the condition of separation between two concave mirrors for the optimum mode matching was found. The conversion efficiency of second harmonic generation was increased by the resonant enhancement of pumping power in the ring enhancement cavity, and the frequency of diode laser was locked to that of the counter-propagation mode generated from the surface of crystal. When the pumping power was 28 mW, the infrared buildup factor was about 45 without the crystal, and 14 with the crystal due to the transmission loss of crystal. The maximum second harmonic powers of $1.5{\mu}W$ and $6.6{\mu}W$ were obtained, and corresponding conversion efficiencies were $(6.584{\pm}0.56){\times}10^{-3}$%, $2.6{\pm}0.21){\times}10%{-2}$% in 5mm- and 10mm-long $LiIO_3$, respectively.

  • PDF

Development of Prediction Model for Sugar Content of Strawberry Using NIR Spectroscopy (근적외선 분광을 이용한 딸기의 당도예측모델 개발)

  • Son, Jaeryong;Lee, Kangjin;Kang, Sukwon;Yang, Gilmo;Seo, Youngwook
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.297-301
    • /
    • 2009
  • This study was performed to develop a prediction model of sugar content for strawberry. Near-infrared (NIR) spectroscopy has been prevailed for on-line and portable applications for non-invasive quality assessment of intact fruit. This work presents effects of illumination method and coating of reflection surface of light source on prediction result of sugar content. Effect of preprocessing methods was also examined. A low-cost commercially available VIS/NIR spectrometer was used for estimation of total soluble solids content (Brix). To predict sugar contents of strawberry, the best results were obtained with the spectrum data measured under intensive illuminations at three locations induced from the light source with fiber optic bundles. Gold coating of reflection surface of light source lamp gave favorable effect to prediction result. The best results in validation of PLSR model were $r_{SEP}$ = 0.891 and SEP = 0.443 Brix under OSC preprocessing and those of PCR were $r_{SEP}$ = 0.845, SEP $r_{SEP}$= 0.520 Brix, under no preprocessing.

The Ship Detection Using Airborne and In-situ Measurements Based on Hyperspectral Remote Sensing (초분광 원격탐사 기반 항공관측 및 현장자료를 활용한 선박탐지)

  • Park, Jae-Jin;Oh, Sangwoo;Park, Kyung-Ae;Foucher, Pierre-Yves;Jang, Jae-Cheol;Lee, Moonjin;Kim, Tae-Sung;Kang, Won-Soo
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.535-545
    • /
    • 2017
  • Maritime accidents around the Korean Peninsula are increasing, and the ship detection research using remote sensing data is consequently becoming increasingly important. This study presented a new ship detection algorithm using hyperspectral images that provide the spectral information of several hundred channels in the ship detection field, which depends on high resolution optical imagery. We applied a spectral matching algorithm between the reflection spectrum of the ship deck obtained from two field observations and the ship and seawater spectrum of the hyperspectral sensor of an airborne visible/infrared imaging spectrometer. A total of five detection algorithms were used, namely spectral distance similarity (SDS), spectral correlation similarity (SCS), spectral similarity value (SSV), spectral angle mapper (SAM), and spectral information divergence (SID). SDS showed an error in the detection of seawater inside the ship, and SAM showed a clear classification result with a difference between ship and seawater of approximately 1.8 times. Additionally, the present study classified the vessels included in hyperspectral images by presenting the adaptive thresholds of each technique. As a result, SAM and SID showed superior ship detection abilities compared to those of other detection algorithms.

A Study on Temperature Characteristics of Various Depth using Infrared Thermography (적외선 열화상기법을 이용한 균열 깊이에 따른 온도특성에 관한 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo;Yang, Hui-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2018
  • The thermal characteristics of concrete specimens were analyzed using cement paste specimens with artificial cracks. In order to understand the temperature characteristics of the specimen depending on the crack depth, the specimen was heated and the minimum temperatures of the specimens at which cracks appear were investigated according to the crack depth. It was confirmed that the surface temperature distribution of the specimen varies depending on whether the specimen is cracked or not, because of the single and multiple reflections of the incident energy. Furthermore, as the temperature distribution of the specimen reaches a steady state, the temperature data tends to decrease with the crack depth. Through the observation of the normalized temperatures, it was found that the temperature of the specimens obtained from this experiment reached a steady state after 10 minutes. At this time, the standard deviation of the normalized temperature is around 0.01 or less, and the temperature decreases linearly with increasing crack depth. This result is considered to be closely related to the area where multiple reflections occur in the cracked region. If the correlation between the crack region and the incident energy is analyzed for various specimens, it can be applied to the diffuse reflection of the light.

The application of a chemical assessment of archaeological animal bone by Fourier transform infrared spectroscopy and x-ray diffraction (FTIR과 XRD를 이용한 출토 동물뼈의 화학적 평가 적용)

  • Kang, Soyeong;Cho, Eun Min;Kim, Sue Hoon;Kim, Yun-Ji;Lee, Jeongwon
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.300-307
    • /
    • 2014
  • For the application of chemical assessment standards by the extent of diagenetic alteration, we investigated three archaeological animal bones and a modern animal bone using Fourier transform infrared-attenuated total reflection (FTIR-ATR) spectroscopy and x-ray diffraction (XRD) analysis. The calculating results of crystallinity index (CI), carbonate-to-phosphate (C/P) and carbonate-to-carbonate (C/C) using FTIR-ATR spectra showed differences CI and C/P according to the preservative condition of animal bones. By comparison of the crystallinity contents using XRD patterns, the states of animal bones were distinguished to the range of $30^{\circ}-35^{\circ}$. As results of FTIR-ATR and XRD analysis, it is suggested that Mongolian large mammals bone presents the best preservative condition, and cattle bone from Naju site, and Haman site followed. In addition, those were correlated with the results of histological index. The results suggested that the chemical assessment standards may contribute to application of predictions of the states of animal bones discovered from Korea.

Real-Time Monitoring of Mitochondrial ATP Synthesis and Hydrolysis by Surface Infrared Spectroscopy

  • Yamaguchi, Ryo-Taro;Hirano-Iwata, Ayumi;Aonuma, Yuki;Yoshimura, Yuya;Shinohara, Yasuo;Kimura, Yasuo;Niwano, Michio
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.108-109
    • /
    • 2013
  • Mitochondria play key roles in the production of cell's energy. Their dominant function is the synthesis of adenosine 5'-triphosphate (ATP) from adenosine diphosphate (ADP) and phosphate (Pi) through the oxidative phosphorylation. Evaluation of drug-induced mitochondrial toxicity has become increasingly important since mitochondrial dysfunction has recently been implicated in numerous diseases including cancer and diabetes mellitus. Mitochondrial functions have been monitored via oxygen consumption, mitochondrial membrane potential, and more importantly via ATP synthesis since ATP synthesis is the most essential function of mitochondria. Various analytical methods have been employed to investigate ATP synthesis in mitochondria, including high performance liquid chromatography (HPLC), bioluminescence technique, and pH measurement. However, most of these methods are based on destructive analysis or indirect monitoring through the enzymatic reaction. Infrared absorption spectroscopy (IRAS) is one of the useful techniques for real-time, label-free, and direct monitoring of biological reactions [1,2]. However, the strong water absorption requires very short path length in the order of several micrometers. Transmission measurements with thin path length are not suitable for mitochondrial assays because solution handlings necessary for evaluating mitochondrial toxicity, such as rapid mixing of drugs and oxygen supply, are difficult in such a narrow space. On the other hand, IRAS in the multiple internal reflection (MIR) geometry provides an ideal optical configuration to combine solution handling and aqueous-phase measurement. We have recently reportedon a real-time monitoring of drug-induced necrotic and apoptotic cell death using MIR-IRAS [3,4]. Clear discrimination between viable and damaged cells has been demonstrated, showing a promise as a label-free and real-time detection for cell-based assays. In the present study, we have applied our MIR-IRAS system to mitochondria-based assays by monitoring ATP synthesis in isolated mitochondria from rat livers. Mitochondrial ATP synthesis and hydrolysis were in situ monitored with MIR-IRAS, while dissolved oxygen level and solution pH were simultaneously monitored with O2 and pH electrodes, respectively. It is demonstrated that ATP synthesis and hydrolysis can be monitored by the IR spectral changes in phosphate groups in adenine nucleotides and MIR-IRAS is useful for evaluating time-dependent drug effects of mitochondrial toxicants.

  • PDF

Autonomous Wheelchair System Using Gaze Recognition (시선 인식을 이용한 자율 주행 휠체어 시스템)

  • Kim, Tae-Ui;Lee, Sang-Yoon;Kwon, Kyung-Su;Park, Se-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.91-100
    • /
    • 2009
  • In this paper, we propose autonomous intelligent wheelchair system which recognize the commands using the gaze recognition and avoid the detected obstacles by sensing the distance through range sensors on the way to driving. The user's commands are recognized by the gaze recognizer which use a centroid of eye pupil and two reflection points extracted using a camera with infrared filter and two infrared LEDs. These are used to control the wheelchair through the user interface. Then wheelchair system detects the obstacles using 10 ultrasonic sensors and assists that it avoid collision with obstacles. The proposed intelligent wheelchair system consists of gaze recognizor, autonomous driving module, sensor control board and motor control board. The gaze recognizer cognize user's commands through user interface, then the wheelchair is controled by the motor control board using recognized commands. Thereafter obstacle information detected by ultrasonic sensors is transferred to the sensor control board, and this transferred to the autonomous driving module. In the autonomous driving module, the obstacles are detected. For generating commands to avoid these obstacles, there are transferred to the motor control board. The experimental results confirmed that the proposed system can improve the efficiency of obstacle avoidance and provide the convenient user interface to user.

Implementation of a Counterfeit Notes Detection Method using IR Sensor (적외선(IR) 센서를 이용한 위폐 감별 방법 구현)

  • Kim, Sun-Gu;Kang, Byeong-Gwon
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.191-197
    • /
    • 2013
  • In this paper, we implemented a paper currency recognition system using IR(infrared) sensor. The system has 32 channel IR sensor to measure the reflection and penetration quantity of light. The IR image of paper currency of 10-bit gray scale is used to differentiate the real and counterfeit paper currency with image information from 0 to 4095. The characteristics of IR image are recognized by brightness and darkness and the positions of bright and dark portions are different between real and counterfeit paper currency. The price of IR sensors were relatively high, however, it is good price in these days due to mass production to apply to counterfeit detection area. We used a software table having the IR characteristics of real paper currency to compare with the IR images of the input paper currency. The performance of the implemented system shows 1-2% error rates for Euro real paper currency and 0% error rates for various counterfeit paper currencies of several countries.