• Title/Summary/Keyword: Infrared Module

Search Result 152, Processing Time 0.031 seconds

A Study on the Development of an Distributed Tabletop System Game Using EBITA Framework (EBITA 프레임워크를 활용한 분산 테이블탑 시스템용 게임 개발에 관한 연구)

  • Kim, Min-Young;Cho, Yong-Joo
    • Journal of Korea Game Society
    • /
    • v.9 no.3
    • /
    • pp.129-138
    • /
    • 2009
  • In this research, a new tabletop system is developed to provide a high resolution display by using multiple displays and computers connected through networks, based on a master/slave architecture. This distributed tabletop system is built to be scalable by just adding slave computers and monitors without modifying any software. Moreover, a EBITA (Environment for Building Interactive Tangible Applications) framework is developed to support constructing interactive games running on this scalable tabletop platforms. EBITA framework consists of the tangible interface module based on the infrared camera tracking system, and the modules that allow easy development of the graphical programs on a distributed environment. This paper describes the tangible interface based on the camera tracking system and EBITA framework. It also introduces a game built with the EBITA framework.

  • PDF

Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens (셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계)

  • Ahn, Gyou-Bong;Kim, Seo-Hyun;Jung, Jae-Chul;Jo, Mun-Shin;Kim, Chang-Woo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • This paper describes the design technology for a third generation thermal imaging system, which is more compact than before, using a $320\times240$ mid-IR focal plane detector. The third generation non-scanning thermal imaging system was constructed as a compact thermal imaging module as a reconnaissance, surveillance and navigation sensor for helicopter and infantry vehicles in the $1980's\sim1990's$ and now, we designed a new compact infrared camera and studied a new type of non-uniformity correction lens fer this camera.

Development and Packaging of Multi-channel Imaging Module for Near-infrared Fluorescence Imaging System (근적외선 형광 영상 시스템용 다채널 영상 모듈 개발 및 패키징)

  • Kim, Taehoon;Seo, Kyung Hwan;Lee, Hak Keun;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.59-64
    • /
    • 2019
  • In this paper, we introduced a near-infrared multi-channel fluorescence imaging system and analyzed the effects of measurements variables such as exposure time, working distance and intensity of excitation light. Fluorescence signal is increased as exposure time becomes longer, excitation light intensity increases or working distance becomes smaller. Furthermore, the proper composition of optical filters and precise packaging of the imaging modules prevent the increase of background signal. Thus, we confirmed an increase in SBR. Based on the result of this research, we proposed a method to use a multi-channel fluorescence imaging system.

Optimization of Heatsink and Analysis of Thermal Property in 75W LED Module for Street Lighting (75W급 LED 가로등 모듈의 방열판 최적화와 열특성 분석)

  • Lee, Seung-Min;Lee, Se-Il;Yang, Jong-Kyung;Lee, Jong-Chan;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.609-613
    • /
    • 2010
  • In this paper, we optimized and simulated the heatsink of 75W LED module for street lighting and evaluated the optical properties with the manufactured heatsink. the structure of LED package make simple as chip and heatslug and thermal flow is analyzed by using the FEM(Finite Element Method) with CFdesign V10. Also, we measured the temperature of heatsink and evaluated the optical properties with infrared thermal image camera and integrated sphere system for luminous flux in $1\;[m^3]$ box. As results, Heatsink optimized in 3 mm pin thickness, 6 mm base thickness and 16 number of pin count by using Heatsink-designer and got the results which is the temperature of $47.37\;[^{\circ}C]$ and thermal resistance of $0.48407\;[W/^{\circ}C]$. In thermal flow simulation, the temperature of heatsink decreased from $51.54\;[^{\circ}C]$ to $51.51\;[^{\circ}C]$ and the temperature of heatsink by the time in real measurement decreased from $47.03\;[^{\circ}C]$ to $46.87\;[^{\circ}C]$. Moreover, we improve 0.68 % in the decreased ratio of the luminous flux.

Design of LED Lighting System using Bluetooth Wireless Communcation (Bluetooth 무선 통신 기능을 이용한 LED 조명시스템 설계)

  • Kim, Hye Myeong;Yang, Woo Seok;Cho, Young Seek;Park, Dae Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • The Light Emitting Diode(LED) lighting control system proposed in this thesis is made up of a sensor module, a microcontroller, Bluetooth wireless communication, LED Driver, and LED downlight. The sensor module, comprised of an infrared sensor, an illumination sensor, and a temperature sensor, was designed to one Printed Circuit board(PCB). The system is able to identify the environment information collected by the sensor, and make it possible to control lighting automatically and manually through sensors. In addition, depending on users' conditions, a color temperature can be controlled. CS-1000, a spectroradiometer, was employed to measure the changing values of a color temperature in 8 steps. According to a test, it was found that it was possible to change a color temperature from 3187K of Warm White LED to 5598K of Cool White LED. The Bluetooth based wireless communication technique makes it possible to control more lighting devices than other wireless communication techniques does.

Mechanical verification logic and first test results for the Euclid spacecraft

  • Calvi, Adriano;Bastia, Patrizia;Suarez, Manuel Perez;Neumann, Philipp;Carbonell, Albert
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.3
    • /
    • pp.251-269
    • /
    • 2020
  • Euclid is an optical/near-infrared survey mission of the European Space Agency (ESA) to investigate the nature of dark energy, dark matter and gravity by observing the geometry of the Universe and the formation of structures over cosmological timescales. The Euclid spacecraft mechanical architecture comprises the Payload Module (PLM) and the Service Module (SVM) connected by an interface structure designed to maximize thermal and mechanical decoupling. This paper shortly illustrates the mechanical system of the spacecraft and the mechanical verification philosophy which is based on the Structural and Thermal Model (STM), built at flight standard for structure and thermal qualification and the Proto Flight Model (PFM), used to complete the qualification programme. It will be submitted to a proto-flight test approach and it will be suitable for launch and flight operations. Within the overall verification approach crucial mechanical tests have been successfully performed (2018) on the SVM platform and on the sunshield (SSH) subsystem: the SVM platform static test, the SSH structure modal survey test and the SSH sine vibration qualification test. The paper reports the objectives and the main results of these tests.

Autonomous Wheelchair System Using Gaze Recognition (시선 인식을 이용한 자율 주행 휠체어 시스템)

  • Kim, Tae-Ui;Lee, Sang-Yoon;Kwon, Kyung-Su;Park, Se-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.91-100
    • /
    • 2009
  • In this paper, we propose autonomous intelligent wheelchair system which recognize the commands using the gaze recognition and avoid the detected obstacles by sensing the distance through range sensors on the way to driving. The user's commands are recognized by the gaze recognizer which use a centroid of eye pupil and two reflection points extracted using a camera with infrared filter and two infrared LEDs. These are used to control the wheelchair through the user interface. Then wheelchair system detects the obstacles using 10 ultrasonic sensors and assists that it avoid collision with obstacles. The proposed intelligent wheelchair system consists of gaze recognizor, autonomous driving module, sensor control board and motor control board. The gaze recognizer cognize user's commands through user interface, then the wheelchair is controled by the motor control board using recognized commands. Thereafter obstacle information detected by ultrasonic sensors is transferred to the sensor control board, and this transferred to the autonomous driving module. In the autonomous driving module, the obstacles are detected. For generating commands to avoid these obstacles, there are transferred to the motor control board. The experimental results confirmed that the proposed system can improve the efficiency of obstacle avoidance and provide the convenient user interface to user.

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Characteristics of Thermal Radiation Pastes Containing Graphite and Carbon Nanotube (흑연 및 탄소나노튜브 혼합 방열도료의 특성)

  • Lee, Ji Hun;Song, Man-Ho;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.2
    • /
    • pp.218-224
    • /
    • 2016
  • Thermal radiation pastes were prepared by dispersing carbon materials as fillers with a content of 1 weight percent in an acrylic resin. The kind of fillers was as follows; $25{\mu}m$ graphite, $45{\mu}m$ graphite, $15{\mu}m$ carbon nanotube(CNT), a 1:1 mixture of $25{\mu}m$ graphite and $15{\mu}m$ CNT, and a 1:1 mixture of $45{\mu}m$ graphite and $15{\mu}m$ CNT. Thermal emissivity was measured as 0.890 for the samples with graphite only, 0.893 for that with CNT only, and 0.892 for those containing both. After coating prepared pastes on a side of 0.4 mm thick aluminium plate and placing the plate over an opening of a box maintained at $92^{\circ}C$ with the coated side out, the temperatures on the uncoated side of the plates were measured. The samples containing graphite and CNT showed the lowest temperatures. The paste with mixed fillers was coated on the back side of the PCB of an LED module and thermal analysis was carried out using Thermal Transient Tester (T3ster) in a still air box. The thermal resistance of the module with coated PCB was measured as 14.34 K/W whereas that with uncoated PCB was 15.02 K/W. The structure function analysis of T3ster data revealed that the difference between junction and ambient temperatures was $13.8^{\circ}C$ for the coated case and $18.0^{\circ}C$ for the uncoated. From the infrared images of heated LED modules, the hottest-spot temperature of the module with coated PCB was lower than that of the uncoated one for a given period of LED operation.

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.