• Title/Summary/Keyword: Infrared Laser

Search Result 330, Processing Time 0.028 seconds

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

Bidirectional Current Triggering in Two-Terminal Planar Device Based on Highly Resistive Vanadium Dioxide Thin Film Using 966nm Near Infrared Laser (966nm 근적외선 레이저를 이용한 고저항성 바나듐 이산화물 박막 기반 2단자 평면형 소자에서의 양방향 전류 트리거링)

  • Kim, Jihoon;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.28-34
    • /
    • 2015
  • By incorporating a 966nm near infrared laser, we demonstrated bidirectional current triggering of between 0 and 10mA in a two-terminal planar device based on a highly resistive vanadium dioxide ($VO_2$) thin film grown by a pulsed laser deposition method. A two-terminal planar device, which had an electrode separation of $100{\mu}m$ and a $50{\mu}m-wide$ $VO_2$ conducting layer, was fabricated through ion beam-assisted milling and photolithographic techniques. A bias voltage range for stable bidirectional current triggering was determined by investigating the current-voltage curves of the $VO_2-based$ device in a current-controlled mode. Bidirectional current triggering of up to 10mA was realized by directly illuminating the $VO_2$ film with a focused infrared laser beam, and the transient responses of triggered currents were analyzed when the laser was modulated at various pulse widths and repetition rates. A switching contrast between off- and on-state currents was evaluated as ~3571, and the rising and falling times were measured as ~40 and ~20ms, respectively.

Portable Infrared Laser Transmitter Based on a Beam Shaper Enabling a Highly Uniform Detectable Beam Width

  • Yue, Wenjing;Kim, Haeng-Jung;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.486-490
    • /
    • 2013
  • A portable infrared laser transmitter delivering a highly uniform detectable beam was demonstrated. It incorporates a flexible beam shaper, comprising a perforated diffuser sheet in conjunction with a pinhole. The beam shaper plays the prominent role of flexibly tailoring the incoming light via both scattering and diffraction, in order to equalize the effective beam width over a long distance. The intensity profile of a generated beam was practically observed, demonstrating that a substantially uniform beam of 70-cm width was achieved for a given threshold detection level, with an average deviation of 6% over a range of 600 m.

Effect of Infrared Low Dose Laser on Injured Sciatic Nerve of Rats (백서의 좌골신경 손상에 미치는 저출력 레이저의 효과 (IR-Laser))

  • Jeong, Jin-Ou;Kwon, Jae-Young;Kim, Hae-Kyu;Baik, Seong-Wan;Kim, Inn-Se;Chung, Kyoo-Sub
    • The Korean Journal of Pain
    • /
    • v.5 no.1
    • /
    • pp.44-51
    • /
    • 1992
  • This study examined the microscopic changes following irradiation of infrared low dose laser on injured sciatic nerves of rats. In these days, many clinicians use the low dose laser therapy in pain clinicians use the low dose laser therapy in pain clinic on various fields and dieases. But the basic mechanism and indications were not known completely. Low-dose IR(infrared) laser irradiation applied to a crushed injured sciatic nerve of rats in the right leg in bilaterally inflicted crush injury. The results were as follows 1) There are a little histological differences between laser treated group and nontreated group. 2) Low power IR-laser irradiation, when applied to the injured sciatic nerve, increased vascularization and relatively well conserved tissue organization. 3) There are little histological difference in distal muscle biopsy, but atrophic muscle fibers were seen partially. 4) We found out that more hypertrophic epineurium was present in laser-treated group.

  • PDF

Development of Screen Shot System using Infrared Laser (적외선 레이저를 이용한 스크린 사격시스템 개발)

  • Kang, Sung-Jun;Kim, Jung-Hoon;Jeong, Sung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1325-1329
    • /
    • 2012
  • This study suggests an indoor screen shooting system that can be connected with diverse graphic contents, through developing a gun only for indoor shooting and developing high-speed laser recognition algorithm. The dedicated gun has strong durability and was applied pneumatic solenoid valve control and invisible laser. The aim is to commercialize the indoor screen shooting system by developing a method of interacting with graphic engine through recognizing invisible laser at high speed.

A Study on Analysis of Heat Flow in Laser Brazing (레이저 브레이징에서의 열유동 해석에 관한 연구)

  • 전민규;김원배;한국찬;나석주
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.96-105
    • /
    • 1995
  • An advantage offered by brazing over fusion welding is that strong joints may be produced at relatively low heat input. To minimize the thermal effects and maintain the desired dimension of assemblies. the CO$_{2}$ laser beam can be applied to the brazed joint of pin and plate as a micro heat source. This paper presents a analysis model of the laser brazing process considering the laser beam mode and heat flow in brazed parts by using the finite element method. The simulation results were compared with the experimental results obtained from the infrared temperature sensing system. Based on these results, the proper process parameters were investigated to get a good joining quality. The influence of the beam mode change was examined with respect to the temperature distribution and joint quality.

  • PDF

Challenges in the development of the ultrafast electron microscope (초고속 전자 현미경의 개발과 극복 과제)

  • Park, Doo Jae
    • Vacuum Magazine
    • /
    • v.2 no.1
    • /
    • pp.17-20
    • /
    • 2015
  • In this article, a historical and scientific review on the development of an ultrafast electron microscope is supplied, and the challenges in further improvement of time resolution under sub-picosecond or even sub-femtosecond scale is reviewed. By combining conventional scanning electron microscope and femtosecond laser technique, an ultrafast electron microscope was invented. To overcome its temporal resolution limit which originates from chromatic aberration and Coulomb repulsion between individual electrons, a generation of electron pulse via strong-field photoemission has been investigated thoroughly. Recent studies reveal that the field enhancement and field accumulation associated with the near-field formation at sharply etched metal nanoprobe enabled such field emission by ordinary femtosecond laser irradiation. Moreover, a considerable acceleration reaching 20 eV with near-infrared laser and up to 300 eV acceleration with mid-infrared laser was observed, and the possibility to control the amount of acceleration by varying the incident laser pulse intensity and wavelength. Such findings are noteworthy because of the possibility of realizing a sub-femtosecond, few nanometer imaging of nanostructured sample.in silicon as thermoelectric materials.

Application of time-of-flight near infrared spectroscopy to Satsuma mandarin

  • Tsuchikawa, Satoru;Ito, Satomi;Inoue, Kinuyo;Miyamoto, Kumi
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1627-1627
    • /
    • 2001
  • In this study, a newly constructed optical measurement system, whose main components were a parametric tunable laser and a near infrared photoelectric multiplier, was applied to detection of the information for the inside of Satsuma mandarin using time-of-flight near infrared spectroscopy (TOF-NIRS). The combined effects on the time resolved profile of sample diameter, sugar content, the wavelength of the laser beam, and the detection position of transmitted light were investigated in detail. The samples used were Satsuma mandarin (Citrus unshu $M^{ARC}$.) (location: Wakayama, Japan) having the diameters of 50-84 mm. The sugar content measured by a refractometer varied from 9.9 to 16.3 Brix%. Equator of sample was irradiated vertically with the pulsed laser, and transmitted output power was measured on the restricted position of the equator using the optical fiber cable. The sampling time and the number of averaging the output power were 100 ns and 100 times, respectively. The variation of the attenuance of peak maxima At, the time delay of peak maxima t and the variation of full width at half maximum w were strongly dependent on the detection position and the wavelength of the laser beam. At, t and w increased gradually as the sample diameter increased to be much absorbed and vigorously scattered. On the other hand, each optical parameter had a tendency to increase as the sugar content increased. Such behavior was remarkable when the transmitted light was detected at the side face of a sample. When we apply TOF-NIRS to detection of the information for the inside of fruit with high moisture content like Satsuma mandarin, it is very important to give attention to the difference in the scattered light within tissues and the semi-straightly propagated light. Furthermore, we tried to express the resulting phenomena by using a model samples composed of water, sucrose, and milk. The variation of the time resolved profile is strongly governed by the combination of the light absorption component, scattering medium, and refractive index.

  • PDF

Application of time-of-flight near infrared spectroscopy to Satsuma mandarin

  • Tsuchikawa, Satoru;Ito, Satomi;Inoue, Kinuyo;Miyamoto, Kumi
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1626-1626
    • /
    • 2001
  • In this study, a newly constructed optical measurement system, whose main components were a parametric tunable laser and a near infrared photoelectric multiplier, was applied to detection of the information for the inside of Satsuma mandarin using time-of-flight near infrared spectroscopy (TOF-NIRS). The combined effects on the time resolved profile of sample diameter, sugar content, the wavelength of the laser beam, and the detection position of transmitted light were investigated in detail. The samples used were Satsuma mandarin (Citrus unshu $M_{ARC}$.) (location: Wakayama, Japan) having the diameters of 50-84 mm. The sugar content measured by a refractometer varied from 9.9 to 16.3 Brix%. Equator of sample was irradiated vertically with the pulsed laser, and transmitted output power was measured on the restricted position of the equator using the optical fiber cable. The sampling time and the number of averaging the output power were 100 ns and 100 times, respectively. The variation of the attenuance of peak maxima At, the time delay of peak maxima $\Delta$t and the variation of full width at half maximum Δw were strongly dependent on the detection position and the wavelength of the laser beam. At, $\Delta$t and $\Delta$w increased gradually as the sample diameter increased to be much absorbed and vigorously scattered. On the other hand, each optical parameter had a tendency to increase as the sugar content increased. Such behavior was remarkable when the transmitted light was detected at the side face of a sample. When we apply TOF-NIRS to detection of the information for the inside of fruit with high moisture content like Satsuma mandarin, it is very important to give attention to the difference in the scattered light within tissues and the semi-straightly propagated light. Furthermore, we tried to express the resulting phenomena by using a model samples composed of water, sucrose, and milk. The variation of the time resolved profile is strongly governed by the combination of the light absorption component, scattering medium, and refractive index.

  • PDF

Half mJ Supercontinuum Generation in a Telecommunication Multimode Fiber by a Q-switched Tm, Ho:YVO4 Laser

  • Zhou, Renlai;Ren, Jiancun;Lou, Shuli;Ju, Youlun;Wang, Yuezhu
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.7-12
    • /
    • 2015
  • Up to ${\sim}520{\mu}J$ broadband mid-infrared (IR) supercontinuum (SC) generation in telecommunication multimode fiber (MMF) directly pumped by a $2.054{\mu}m$ nanosecond Q-switched Tm, $Ho:YVO_4$ laser is demonstrated. An average output power of 3.64 W is obtained in the band of ~1900 to ~2600 nm, and the corresponding optic-to-optic conversion efficiency is 67% by considering the coupling efficiency. The spectrum has extremely high flatness with negligible intensity variation (<2%) in the wavelength interval of ~2070 to ~2475 nm. The SC long-wavelength edge is limited by the silicon glass material loss, and by optimizing the MMF length, the SC spectrum could extend out to ${\sim}2.6{\mu}m$. The output SC pulse shapes are measured at different output powers, and no splits are found. The SC laser beam is nearly diffraction limited with an $M^2=1.15$ in $2.1{\mu}m$ measured by the traveling knife-edge method, and the laser beam spot is monitored by an infrared vidicon camera.