• 제목/요약/키워드: Infrared: imaging

검색결과 767건 처리시간 0.024초

경추증성 척수증 환자 1례에 대한 임상적 고찰 (Clinical Study on a Case of Cervical Myelopathy)

  • 이옥자;윤민영;김홍훈;조남근
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.220-229
    • /
    • 2003
  • Objective : Cervical myelopathy is one of the most severe disease, as well as a common diesaes. However, its clinical study and report about efficiency of oriental treatment are absolutely insufficient. Therefore, we report the treatment about 1 case of Cervical myelopathy like followings. Methods : From November 27th, 2002 to January 11th, 2003, we observed patient hospitalized because of cervical myelopathy, and for its valuation, JOA score(Japanese Orthopedic Association score), Nutric grading, VAS(visual analog scale), and D.I.T.I(Digital Infrared Thermal Imaging)were used. Results : After being hospotalized for 50 days, the patients' JOA score, Nuric grading system, and VAS were improved each from 7 to 13, from grade IV to grade II, and from 8 to 2. Conclusions : We considered that oriental treatment has an useful effect on cervical myelopathy patients' treatment and recovery. But continuous studies, such as comparative studies accompanied by more treatment case.

  • PDF

미소안면침 시술후 안면부 체온변화에 대한 임상적 고찰;A case study (The Changes of Facial Temperature by Miso Facial Rejuvenation Acupuncture;A case study)

  • 황덕상;송정화;김용석;이경섭
    • Journal of Acupuncture Research
    • /
    • 제25권1호
    • /
    • pp.89-95
    • /
    • 2008
  • Objectives : To investigate changes in facial temperature generated by Miso Facial Rejuvenation Acupuncture treatment. Methods : One middle-aged woman with no diseases was recruited. Miso Facial Rejuvenation Acupuncture was performed on only the right side of her face. We measured her facial temperature using digital infrared thermal imaging(DOREX Inc. Spectrum 9,000MB, USA, D.I.T.I) before, immediately after, and 10 minutes after treatment. We also used the Wilcoxon signed rank test(p<0.05) to compare the differences in facial temperature from one side of the face to the other at each time. Results : Facial temperature on the right side(the area treated by acupuncture) increased immediately from $30.02{\pm}1.87^{\circ}C$ to $32.24{\pm}1.03^{\circ}C$, a statistically significant increase. Ten minutes after treatment, facial temperature on the right side decreased a little bit, but there was no statistical significance. Facial temperature on the left side increased a little, but there was no statistical significance. The difference between the right and left sides of the face increased after the Miso Facial Rejuvenation Acupuncture treatment. Conclusions : Miso Facial Rejuvenation Acupuncture could increase facial temperature.

  • PDF

퇴행성 슬관절염 평가도구와 적외선 체열촬영과의 상관관계 연구 (The Study About the Correlation between Assessment Instruments of Knee OA and DITI)

  • 김희권;이상훈;서정철;이승덕;최선미;김용석
    • Journal of Acupuncture Research
    • /
    • 제23권1호
    • /
    • pp.155-164
    • /
    • 2006
  • Objectives : The aim of this study is to validate the correlation between Assessment Instruments of Knee OA and digital infrared thermographic imaging(DITI) and to find out the methods to assess knee OA by DITI. Methods : 60 subjects were evaluated. They were asked to answer VAS pain scale, WOMAC, KHAQ and LFI. Correlation was assessed by examining the spearman's rank correlation coefficients. Results : VAS, WOMAC and LFI was correlated with not only the thermal difference between Ant. knee and Post. knee, but also the lowest temperature of Ant. knee. Conclusion: DITI value was useful for evaluating the degree of OA. And we should find out that decrease of pain is correlated with change of DITI value.

  • PDF

장시간 부동 자세로 야기된 급성 비골신경 마비 환자의 한방치료 증례보고 (Case Report of Korean Medical Treatment on Acute Peroneal Nerve Palsy Patient Caused by Prolonged Immobilization)

  • 김민수;김진희;이지영;염승룡;권영달
    • 한방재활의학과학회지
    • /
    • 제25권3호
    • /
    • pp.127-136
    • /
    • 2015
  • Objectives This study was carried out to investigate the clinical effects of Korean medical treatment on acute peroneal nerve palsy caused by prolonged immobilization. Methods One patient with acute peroneal nerve palsy was treated with various korean medical techniques such as acupuncture, moxibustion, cupping and herbal medicine, bee-venom acupuncture for 12 weeks. Manual Muscle Test, Range of motion, Numerical Rating Scale, Ankle-hindfoot scale, Digital infrared thermographing imaging system were used to evaluate treatment effect. Results After treatment, all the scales mentioned above were improved significantly. Conclusions This result showed that Korean medical treatment is effective on acute peroneal nerve palsy caused by prolonged immoblization.

섬유근통 환자의 한의학적 치료 효과 증례보고 (The Clinical Study on a Case of Fibromyalgia Syndrome Patient by Korean Medicine Treatment)

  • 이지영;김민수;염승룡;권영달
    • 한방재활의학과학회지
    • /
    • 제26권4호
    • /
    • pp.127-136
    • /
    • 2016
  • The purpose of this study is to report a clinical progress of fibromyalgia syndrom patient treated by Korean Medicine treatment. The patient was treated with acupuncture, acupotomy, pharmacopuncture (Bee venom, Hwangryun, Hominis Placental), herbal medicine, moxibustion, cupping treatment. We measured Visual Analogue Scale (VAS), American College of Rheumatology Preliminary Diagnostic Criteria (ACR, 2010), Fibromyalgia Impact Qustionnaire (FIQ), and observed the change in body temperature using Digital Infrared Thermal Imaging (DITI). After Korean Medicine treatment, pain was controlled and VAS, ACR, FIQ were decreased. The result showed that Korean Medicine treatment is effective in fibromyalgia syndrome.

신소재 복합재료를 이용한 우주용 카메라 구조의 고안정화 설계에 관한 연구 (Study on spaceborne telescope structure with high stability using new composite materials)

  • EUNG-SHIK LEE;SUN-HEE WOO
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.132-136
    • /
    • 2003
  • A Multi-Spectral Camera (MSC) is the payload of KOMPSAT-2 which is designed for earth imaging in visible and near-Infrared region on a sun-synchronous orbit. The telescope in the MSC is a Ritchey-Chretien type with large aperture. The telescope structure should be well stabilized and the optical alignment should be kept steady so that best images can be achieved. However, the MSC is exposed to adverse thermal environment on the orbit which can give impacts on optical performance. Metering structure which is exposed to adverse space environment should have tight requirement of low thermal expansion and hygroscopic stability. In order to meet those stability requirements in addition to fundamental structural ones telescope structure was designed with newly developed graphite-cyanate composite which has high tensile modulus, high thermal conductivity and low moisture absorption compared with conventional graphite-epoxy composite. In this paper, space-borne telescope structure with new composite material will be presented and fulfillment of stability requirements will be verified with designed structure.

  • PDF

적외선 열화상 카메라를 이용한 고속가공에서의 열 발생 특성 (Characteristics of Heat Generation in time of High-speed Machining using Infrared Thermal Imaging Camera)

  • 이상진;박원규;이상태;이우영;하만경
    • 한국기계가공학회지
    • /
    • 제2권3호
    • /
    • pp.26-33
    • /
    • 2003
  • The term 'High Speed Machining' has been used for many years to describe end milling with small diameter tools at high rotational speeds, typically 10,000-100,000rpm. The process was applied in the aerospace industry for the machining of light alloys, notably aluminum. In recent year, however, the mold and die industry has begun to use the technology for the production of components, including those manufactured from hardened tool steels. With increasing cutting speed used in modern machining operation, the thermal aspects of cutting become more and mole Important. It not only directly influences in rate of tool weal, but also affects machining precision recognized as thermal expansion and the roughness of the surface finish. Hence, one needs to accurately evaluate the rate of cutting heat generation and temperature distributions on the machining surface. To overcome the heat generation, we used to cutting fluid. Cutting fluid plays a roles in metal cutting process. Mechanically coupled effectiveness of cutting fluids affect to friction coefficient at tool-workpiece interface and cutting temperature and chip control, surface finish, tool wear and form accuracy. Through this study, we examined the behavior of heat generation in high-speed machining and the cooling performance of various cooling methods.

  • PDF

여드름 환자의 허실(虛實)에 따른 양도락(良導絡) 및 적외선체열진단 결과 분석 (The Results of Yangdorak(良導絡) and D.I.T.I,, according to Deficiency or Excess(虛實) of Acne Patients)

  • 정민영;김대수;박수연;김종한;최정화;박용호
    • 한방안이비인후피부과학회지
    • /
    • 제20권2호통권33호
    • /
    • pp.171-178
    • /
    • 2007
  • Objective : The aim of this study was to evaluate Yangdorak and D.I.T.I. for analysis of Symptom-complexes. Method : This study was selected 26 acne patients in Dongshin University Oriental Medical Hospital. We used Yangdorak (SME5800N, Sord Medicom Co., Korea) and D.I.T.I. (Digital Infrared Thermal Imaging 256, Dorex Inc, Orange CA, USA) and investigated the results of Yangdorak and D.I.T.I.. We made a comparison according to Deficiency or Excess(虛實) of acne patients. Result : In comparing Yangdorak results according to Deficiency or Excess(虛實) of acne patients, Triple-energizer(三焦), Intestine(大腸), Liver(肝), Stomach(胃) meridian in Excess group are higher than Deficiency group, and Kidney(腎) meridian in Deficiency group are lower than Excess group. D.I.T.I. reveald hyperthemia of face and chest on acne patients. The temperature of face and chest on Excess group is higher than Deficiency group. There is no statistically significant value compared with data of other group.

  • PDF

Dust Properties in Afterglow of GRB071025 at z~5: Evidence for Supernovae-produced Dust in the Early Universe

  • Jang, Min-Sung;Im, Myung-Shin;Lee, In-Duk;Urata, Y.;Huang, L.;Fan, Xiaohui;Jiang, Lihua
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.35.2-35.2
    • /
    • 2010
  • It is crucial to understand the dust properties in the early universe since they provide important clues about how the early cosmic star formation should be interpreted in the presence of dust extinction. GRB 071025 is an unusually red GRB that occured at high redshift, offering an unique opportunity to study the dust properties in the early universe. We investigate the extinction properties of GRB 071025 through the analysis of RIJHK data obtained with the 1-m telescope at Mt. Lemmon Optical Astronomy Observatory (LOAO) and Simultaneous Quad Infrared Imaging Device (SQIID) on the Kitt-Peak Mayall 4-m telescope. Our dataset is independent from that in a previous work (Perley et al. 2010) where a small systematic photometric errors could complicate the interpretation. After determining the temporal power law exponent with five I-band frames from LOAO, we construct a multi-band monochromatic SED of the GRB afterglow. By using various extinction laws, we find that the SED is best fitted with models that incorporate SNe II dust and derive a photometric redshift of 4.99(+0.12/-0.03). Our results strongly support the prior claim that dusts in GRB 071025 originate mainly from supernovae, implying SNe II predominantly contributed to the dust enrichment in the early universe (z ~ 5).

  • PDF

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • 항공우주산업기술동향
    • /
    • 제6권1호
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF