• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.028 seconds

Observation on Change of Body Temperature for Patients with Low Back Muscular Pain after Electromagnetic Theraphy: a Randomized, Patient-assessor Blind, Placebo-controlled, Pilot Trial Study (자기를 이용한 경락 자극요법 시행 후 요부근육통 환자의 체열변화 관찰: 무작위배정, 환자-평가자 눈가림, 위기기 대조군, 예비 임상 연구)

  • Cho, Woong-Hee;Park, Won-Hyung;Cha, Yun-Yeop;Sun, Seung-Ho;Lee, Seon-Goo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.145-156
    • /
    • 2011
  • Objectives: This study was resigned to observe change of body temperature for patients with low back muscular pain after NUGA MRT-II(pulsed electromagnetic therapy) treatment. Methods: This study was a randomized, patient-assessor blind, placebo-controlled, pilot trial study. After the approval of institutional review board(IRB), we have recruited 38 patients suffering from low back muscular pain and divided them into two groups randomly: the treatment group and control group. To the treatment group, NUGA MRT-II was practiced and to the control group sham device was practiced and their low back muscles and acupuncture points three times a week for 2 weeks from February 2011 to May 2011. After 1 week of last treatment, We compared body temperature of two groups. Results: 1. There was significant decrease of body temperature on both Shinsu(BL23), Chishil(BL52), Kwanwonsu(BL26) acupunture points for the treatment group. 2. There was no difference in the decrease of body temperature between treatment group and control group except. Left Kwanwonsu(BL26). Conclusions: We found out that treatment of NUGA MRT-II on low back muscular pain can reduce the temperature of low back.

Moxibustion Therapy for the Pain Relief in Patient with Type I CRPS: a Case Report (뜸치료의 제 1형 복합부위통증증후군 환자에 대한 통증완화 효과: 증례 보고)

  • Cho, Hyun-Woo;Shin, Byung-Cheul;Shin, Mi-Suk;Hwang, Eui-Hyoung;Sul, Jae-Uk
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.3
    • /
    • pp.79-87
    • /
    • 2011
  • Objectives : The aim of this study was to observe the pain relief effect of moxibustion therapy in a patient with complex regional pain syndrome(CRPS). Methods : A male with type I CRPS, 48-year-old, who suffered from severe pain and paresthesia on his legs despite of treatments of oral medications and spinal cord stimulation was treated by indirect moxibustion following Korean medicine dianosis. Total 20 moxibustion treatments(once daily, 5 days a week, for 4 weeks) were given on the 4 acupoints(both side) where known to be effective fro the CRPS. Visual analogue scale(VAS), digital infrared thermal imaging(DITI), Beck depression index(BDI) were evaluated before and after the treatments. Pain relief, thermal changes on affected legs, and improvement of depression scale were observed after the treatments. Results : As for DITI, right thigh showed low temperature compared with left on before the treatments. While after the treatments, DITI showed similar temperature in both legs at discharge day. Conclusions : Though it is a case report, moxibustion therapy might have pain relief effect. Further rigorous case series and controlled trials are warranted.

Effect of Acupuncture and High Frequency Therapy Applied to the Region Branching to the External Carotid Artery on Reduction of Facial Edema in Patients with Sequelae of Peripheral Facial Palsy: A Case Report (말초성 안면마비 후유증 환자에서 침 치료와 바깥목동맥으로의 분지 영역에 시행한 고주파 병행 치료의 안면부종 감소 효과: 증례보고)

  • An, Sunjoo;Choi, Seonghwan;Kang, Shinwoo;Park, Seohyun;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.4
    • /
    • pp.233-241
    • /
    • 2020
  • This study was performed to evaluate the effect of high frequency therapy applied to the region branching to the external carotid artery for peripheral facial paralysis sequelae. A patient suffering with facial edema due to facial paralysis sequelae had been treated with acupuncture, high frequency therapy on the branch area to the external carotid artery for 7 weeks. The evaluation of clinical outcome was done by degree of swelling by measuring the distance of the face and skin temperature of face through digital infrared thermographic imaging. After treatment, the patient's degree of swelling and the temperature difference between the affected side and normal side was decreased. In addition, the temperature was changed in the entire facial area as well as the treatment point of high frequency therapy. This result shows that acupuncture combined with high frequency therapy at the region branching to the external carotid artery could be an effective way to improve facial blood flow, although further clinical studies will be needed.

Automatic detection of tooth cracks in optical coherence tomography images

  • Kim, Jun-Min;Kang, Se-Ryong;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.41-50
    • /
    • 2017
  • Purpose: The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. Methods: We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. Results: The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than $100{\mu}m$. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. Conclusions: We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.

Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer

  • Kim, Mina;Son, Sang-Yong;Cui, Long-Hai;Shin, Ho-Jung;Hur, Hoon;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.145-153
    • /
    • 2017
  • Purpose: Identification of the infrapyloric artery (IPA) type is a key component of pylorus-preserving gastrectomy. As the indocyanine green (ICG) fluorescence technique is known to help visualize blood vessels and flow during reconstruction, we speculated that this emerging technique would be helpful in identifying the IPA type. Materials and Methods: From August 2015 to February 2016, 20 patients who underwent robotic or laparoscopic gastrectomy were prospectively enrolled. After intravenous injection of approximately 3 mL of ICG (2.5 mg/mL), a near-infrared fluorescence apparatus was applied. The identified shape of the IPA was confirmed by examining the actual anatomy following infrapyloric dissection. Results: The mean interval time between ICG injection and visualization of the artery was 22.2 seconds (range, 14-30 seconds), and the mean duration of the arterial phase was 16.1 seconds (range, 9-30 seconds). The overall positive predictive value (PPV) of ICG fluorescence in identifying the IPA type was 80% (16/20). The IPA type was incorrectly predicted in four patients, all of whom were obese with a body mass index (BMI) of more than $25kg/m^2$. Conclusions: Our preliminary results indicate that intraoperative vascular imaging using the ICG fluorescence technique may be helpful for robotic or laparoscopic pylorus-preserving gastrectomy.

Parameterized Modeling of Spatially Varying PSF for Lens Aberration and Defocus

  • Wang, Chao;Chen, Juan;Jia, Hongguang;Shi, Baosong;Zhu, Ruifei;Wei, Qun;Yu, Linyao;Ge, Mingda
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.136-143
    • /
    • 2015
  • Image deblurring by a deconvolution method requires accurate knowledge of the blur kernel. Existing point spread function (PSF) models in the literature corresponding to lens aberrations and defocus are either parameterized and spatially invariant or spatially varying but discretely defined. In this paper, a parameterized model is developed and presented for a PSF which is spatially varying due to lens aberrations and defocus in an imaging system. The model is established from the Seidel third-order aberration coefficient and the Hu moment. A skew normal Gauss model is selected for parameterized PSF geometry structure. The accuracy of the model is demonstrated with simulations and measurements for a defocused infrared camera and a single spherical lens digital camera. Compared with optical software Code V, the visual results of two optical systems validate our analysis and proposed method in size, shape and direction. Quantitative evaluation results reveal the excellent accuracy of the blur kernel model.

HIGH REDSHIFT QUASAR SURVEY WITH IMS

  • JEON, YISEUL;IM, MYUNGSHIN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.405-407
    • /
    • 2015
  • We describe a survey of quasars in the early universe, beyond z ~ 5, which is one of the main science goals of the Infrared Medium-deep Survey (IMS) conducted by the Center for the Exploration of the Origin of the Universe (CEOU). We use multi-wavelength archival data from SDSS, CFHTLS, UKIDSS, WISE, and SWIRE, which provide deep images over wide areas suitable for searching for high redshift quasars. In addition, we carried out a J-band imaging survey at the United Kingdom InfraRed Telescope with a depth of ~23 AB mag and survey area of ${\sim}120deg^2$, which makes IMS a suitable survey for finding faint, high redshift quasars at z ~ 7. In addition, for the quasar candidates at z ~ 5.5, we are conducting observations with the Camera for QUasars in EArly uNiverse (CQUEAN) on the 2.1m telescope at McDonald Observatory, which has a custom-designed filter set installed to enhance the efficiency of selecting robust quasar candidate samples in this redshift range. We used various color-color diagrams suitable for the specific redshift ranges, which can reduce contaminating sources such as M/L/T dwarfs, low redshift galaxies, and instrumental defects. The high redshift quasars we are confirming can provide us with clues to the growth of supermassive black holes since z ~ 7. By expanding the quasar sample at 5 < z < 7, the final stage of the hydrogen reionization in the intergalactic medium (IGM) can also be fully understood. Moreover, we can make useful constraints on the quasar luminosity function to study the contribution of quasars to the IGM reionization.

MOLECULAR GAS AND RADIO JET INTERACTION: A CASE STUDY OF THE SEYFERT 2 AGN M51

  • MATSUSHITA, SATOKI;TRUNG, DINH-V;BOONE, FRDERIC;KRIPS, MELANIE;LIM, JEREMY;MULLER, SEBASTIEN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.439-442
    • /
    • 2015
  • We observed multiple CO transition lines and the HCN(1-0) line at ~ 1" (~ 34 pc) or higher resolution toward the Seyfert 2 nucleus of M51 using the IRAM Plateau de Bure Interferometer (PdBI) and the Submillimeter Array (SMA). All the images show very similar overall molecular gas distribution; there are two discrete clouds at the eastern and western sides of the nucleus, and the western cloud exhibits an elongated distribution and velocity gradient along the radio jet. In addition, high HCN(1-0)/CO(1-0) brightness temperature ratios of about unity have been observed, especially along the radio jet, similar to those observed in shocked molecular gas in our Galaxy. This strongly indicates that the molecular gas along the jet is shocked, that the radio jet and the molecular gas are interacting, and the jet is entraining both diffuse (CO) and dense (HCN) molecular gas outwards from the circumnuclear region. This is the first clear imaging of the outflowing molecular gas entrained by the AGN jet, and showing the detailed physical status of outflowing molecular gas. Since a relatively high HCN(1-0)/CO(1-0) ratio has been observed in the high velocity wing of ultraluminous infrared galaxies, it can also be explained by a similar mechanism to those we describe here.

5 Cases of Climacteric Syndrome Patients with Hwa-Byung (火病을 동반한 갱년기 환자 치험 5례)

  • Song, Yu-Rim;Park, Kyung-Mi;Yang, Seung-Jeong;Lee, Eun-Kyu;Kim, Hye-Hwa;Cho, Seong-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.4
    • /
    • pp.80-90
    • /
    • 2016
  • Objectives: The purpose of this study is to evaluate the effects of Korean traditional treatments for Climacteric Syndrome Patients with Hwa-Byung. Methods: From February 2015 to May 2015, We treated 5 Cases Patients with Korean traditional treatments for a month. We measured treatment effects by Menopause Rating Scale (MRS), Beck's Depression Inventory (BDI), Visual Analogue Scale (VAS) and Digital Infrared Thermal Imaging (DITI). Results: After treatment, First, the scores of MRS, BDI were decreased. Second, the symptoms such as hot flush, pantalgia, palpitation, insomnia, fatigue were significantly improved. Also, the difference of 膻中 (CV17, Danjung) and 關元 (CV4, Guanyuan) temperatures were significantly decreased after treatment. Conclusions: This study suggests that Korean traditional treatments such as Gamicheonglijagam-hwan, acupuncture, moxibustion are effective on Climacteric Syndrome Patients with Hwa-Byung.

Plant Growth Monitoring Using Thermography -Analysis of nutrient stress- (열영상을 이용한 작물 생장 감시 -영양분 스트레스 분석-)

  • 류관희;김기영;채희연
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.293-300
    • /
    • 2000
  • Automated greenhouse production system often require crop growth monitoring involving accurate quantification of plant physiological properties. Conventional methods are usually burdensome, inaccurate, and harmful to crops. A thermal image analysis system can accomplish rapid and accurate measurements of physiological-property changes of stressed crops. In this research a thermal imaging system was used to measure the leaf-temperature changes of several crops according to nutrient stresses. Thermal images were obtained from lettuce, cucumber, and pepper plants. Plants were placed in growth chamber to provide relatively constant growth environment. Results showed that there were significant differences in the temperature of stressed plants and non-stressed plants. In a case of the both N deficiency and excess, the leaf temperatures of cucumber were $2^{\circ}C$ lower than controlled temperature. The leaf temperature of cucumber was $2^{\circ}C$ lower than controlled temperature only when it was under N excess stress. For the potassium deficiency or excess stress, the leaf temperaures of cucumber and hot pepper were $2^{\circ}C$ lower than controls, respectively. The phosphorous deficiency stress dropped the leaf temperatures of cucumber and hot pepper $2^{\circ}C$ and $1.5^{\circ}C$ below than controls. However, the leaf temperature of lettuce did not change. It was possible to detect the changes in leaf temperature by infrared thermography when subjected to nutrition stress. Since the changes in leaf temperatures were different each other for plants and kinds of stresses, however, it is necessary to add a nutrient measurement system to a plant-growth monitoring system using thermography.

  • PDF