• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.028 seconds

Selection on Optimal Bands to EstimateYield of the Chinese Cabbage Using Drone-based Hyperspectral Image (드론 기반 초분광 영상을 이용한 배추 단수 추정의 최적밴드 선정)

  • Na, Sang-il;Park, Chan-won;So, Kyu-ho;Ahn, Ho-yong;Lee, Kyung-do
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.375-387
    • /
    • 2019
  • The use of drone-based hyperspectral image offers considerable advantages in high resolution remote sensing applications. The primary objective of this study was to select the optimal bands based on hyperspectral image for the estimation yield of the chinese cabbage. The hyperspectral narrow bands were acquired over 403.36 to 995.19 nm using a 3.97 nm wide, 150 bands, drone-based hyperspectral imaging sensor. Fresh weight data were obtained from 2,031 sample for each field survey. Normalized difference vegetation indices were computed using red, red-edge and near-infrared bands and their relationship with quantitative each fresh weights were established and compared. As a result, predominant proportion of fresh weights are best estimated using data from three narrow bands, in order of importance, centered around 697.29 nm (red band), 717.15 nm (red-edge band) and 808.51 nm (near-infrared band). The study determined three spectral bands that provide optimal chinese cabbage productivity in the visible and near-infrared portion of the spectrum.

Correlation Analysis of Cutter Acting Force and Temperature During the Linear Cutting Test Accompanied by Infrared Thermography (선형절삭시험과 적외선 열화상 측정을 통한 픽커터 작용력과 발생 온도의 상관관계 분석)

  • Soo-Ho Chang;Tae-Ho Kang;Chulho Lee;Hoyoung Jeong;Soon-Wook Choi
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.519-533
    • /
    • 2023
  • In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.

A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler (회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구)

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kimm, Dae-Woong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF

Spectroscopic Confirmation of Galaxy Clusters at z~0.92

  • Kim, Jae-Woo;Im, Myungshin;Lee, Seong-Kook;Hyun, Minhee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.45.1-45.1
    • /
    • 2015
  • Galaxy clusters have provided important information to understand the evolution of the universe, since the number density and mass of clusters are tightly related to the cosmological parameters. In addition, galaxy clusters are an excellent laboratory to investigate the galaxy evolution in dense environments. However, finding galaxy clusters at high redshift ($z{\geq}1$) still remains as a main subject in astronomy due to their rareness and difficulty in identifying such objects from optical imaging data alone. Here, we report a spectroscopic follow-up observation of distant galaxy cluster candidates identified by a deep optical-NIR dataset of Infrared Medium-deep Survey. Through the galaxy spectra taken with the IMACS instrument on the Magellan telescope, we confirm at least 3 massive clusters at z~0.92. Interestingly, the maximum spatial separation between these clusters is ~8Mpc, which implies that this system is a new supercluster in the distant universe. We also discuss properties of galaxies in these clusters based on multi-wavelength photometric data.

  • PDF

PATIAL DISTRIBUTION OF STAR FORMATION ACTIVITY ON NGC 253 BY FIR AND RADIO EMISSION LINES

  • Takahashi, H.;Matsuo, H.;Nakanishi, K.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.261-262
    • /
    • 2012
  • The aim of this research is to reveal the spatial distribution of the star formation activity of nearby galaxies by comparing CO molecular emission lines with the large area observation in far-infrared (FIR) lines. We report the imaging observations of NGC 253 by FIR forbidden lines via FIS-FTS and CO molecular lines from low to high excitation levels with ASTE, which are good tracers of star forming regions or photo-dissociation regions, especially spiral galaxies, in order to derive the information of the physical conditions of the ambient interstellar radiation fields. The combination of spatially resolved FIR and sub-mm data leads to the star formation efficiency within galaxy. The ratio between the FIR luminosity and molecular gas mass, $L_{FIR}/M_{H_2}$, is expected to be proportional to the number of stars formed in the galaxy per unit molecular gas mass and time. Moreover the FIR line ux shows current star formation activity directly. Furthermore these can be systematic and statistical data for star formation history and evolution of spiral galaxies.

Synthesis and Characterization of Upconversion Nanoparticles for Cancer Therapy

  • Choe, Seung-Yu;Kim, Bo-Bae;Kim, Eun-Bi;Lee, Seung-U;Jeon, Seon-A;Park, Tae-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.420.2-420.2
    • /
    • 2016
  • Various fields have been paid attention to upconversion nanoparticles (UCNPs) because of its unique optical properties. Moreover, to use the UC luminescent techniques through cell images for identified apoptosis/necrosis of cancer cells have been performed. They have been studied for a versatile biomedical application such as a biosensing tool, or delivery of active forms of medicines inside living cells. UCNPs have distinctive characteristics such as photoluminescence, special emission, low background fluorescence signal and good colloidal stability, which have many advantages compared with the organic dyes and quantum dots. UCNPs have not only a great potential for imaging (UC luminescence) but also therapies (photo-thermal therapy, PTT and photo-dynamic therapy, PDT) in cancer diagnostics. Therefore, we report the enhancement of upconversion red emission in NaYF4:Yb3+,Er3+ nanoparticles, synthesized via solid-state method with the thermal decomposition of trifluoroacetate as precursors and organic solvent at a high boiling point. The UCNPs have an emission in the field of near infrared wavelength, cubic shape and nano-size in length. In this study, we will further investigate it for cancer therapy with NIR optical detection onto the solid substrate.

  • PDF

Complex Regional Pain Syndrome on Post-Stroke Patients with Korean Medicine: A Case Series of Three Patients (뇌졸중 후 발병한 복합부위 통증증후군 환자의 한방치료로 호전된 치험 3례 보고)

  • Byun, Sung-Bum;Yun, Jong-Min;Moon, Byung-Soon
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.573-584
    • /
    • 2014
  • Objectives: This study was performed to evaluate the efficacy of Korean Medicine on post-stroke patients with upper limb pain due to complex regional pain syndrome diagnosed by three-phase bone scan, digital infrared thermal imaging, and International Association for the Study of Pain diagnostic criteria Methods: To evaluate the effectiveness of the treatments, visual analogue scale, medical research council grade, Brunnstrom stage of motor recovery, modified Ashworth scale, and Korean modified Barthel index were used. Results: After Korean medical treatments like acupuncture, herb medication, bee-venom therapy and rehabilitation therapy for 4 weeks, upper limb pain was considerably less and function of upper limbs was improved. Conclusions: Korean medical treatments have some good effects on post-stroke patients with complex regional pain syndrome.

Diagnostic Tool for Cold Sensation of Hands: A Preliminary Study (수부냉증 진단방법에 관한 기초연구)

  • Ko, Seung-woo;Park, Jong-ju;Kong, Kyung-hwan;Go, Ho-yeon
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • Objectives: The aim of this study was to find an effective medical device to detect cold sensation of hands. Methods: Patients with cold sensation of hands (N=42) were recruited in July 2013. We surveyed patients’ general characteristics, severity of cold sensation, body temperature in Nogung (PC8) and Hyeopbaek (LU4) measured with a digital thermometer, digital infrared thermal imaging, and pulse wave velocity. Results: The relation between severity of cold sensation and temperature in Nogung (PC8) and Hyeopbaek (LU4) was statistically significant. The results showed a higher correlation of severity of cold sensation with Nogung (PC9) than with Hyeopback (LU4) temperature. No other indices were statistical significant. Conclusions: Measuring the Nogung (PC9) temperature is most reasonable for assessing the severity of cold sensation of hands. To generalize this result, however, a large-scale study is warranted.

Fibromyalgia Syndrome Combined with Insomnia and Depression Disorder Managed with Korean Medical Treatment: A Case Report (한의학적 치료로 호전된 불면과 우울을 동반한 섬유근통 증후군 환자 치험 1례)

  • Kim, Eui-su;Shin, Min-koo;Kim, Tae-ryun;Oh, Jae-seon;Ma, Young-hun;Le, Young-su
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.400-409
    • /
    • 2015
  • Objectives The study aimed to evaluate the therapeutic effect of Hyungtonghaeul-tang along with Korean medicine treatment for fibromyalgia syndrome. Methods A patient with fibromyalgia syndrome was treated with Hyungtonghaeul-tang as well as Korean medical treatment including acupuncture, electro-acupuncture, bee venom therapy, chuna, aromatherapy, and physical therapy. The counts of tenderness points, widespread pain index (WPI), symptom severity scale score (SS scale score), digital infrared thermal imaging (DITI), Ryodoraku diagnosis, visual analogue scale (VAS), fibromyalgia impact questionnaire (FIQ), and beck depression inventory (BDI) were measured. Results After treatment, the counts of tenderness point, WPI, SS scale score, VAS, FIQ, and BDI were decreased. The DITI and the Ryodoraku pattern recovered normally. Conclusions Hyungtonghaeul-tang along with Korean medicine treatment can be used in the treatment of fibromyalgia syndrome.

Fundamental Research on Spring Season Daytime Sea Fog Detection Using MODIS in the Yellow Sea

  • Jeon, Joo-Young;Kim, Sun-Hwa;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.4
    • /
    • pp.339-351
    • /
    • 2016
  • For the safety of sea, it is important to monitor sea fog, one of the dangerous meteorological phenomena which cause marine accidents. To detect and monitor sea fog, Moderate Resolution Imaging Spectroradiometer (MODIS) data which is capable to provide spatial distribution of sea fog has been used. The previous automatic sea fog detection algorithms were focused on detecting sea fog using Terra/MODIS only. The improved algorithm is based on the sea fog detection algorithm by Wu and Li (2014) and it is applicable to both Terra and Aqua MODIS data. We have focused on detecting spring season sea fog events in the Yellow Sea. The algorithm includes application of cloud mask product, the Normalized Difference Snow Index (NDSI), the STandard Deviation test using infrared channel ($STD_{IR}$) with various window size, Temperature Difference Index(TDI) in the algorithm (BTCT - SST) and Normalized Water Vapor Index (NWVI). Through the calculation of the Hanssen-Kuiper Skill Score (KSS) using sea fog manual detection result, we derived more suitable threshold for each index. The adjusted threshold is expected to bring higher accuracy of sea fog detection for spring season daytime sea fog detection using MODIS in the Yellow Sea.