• Title/Summary/Keyword: Infra-Red Thermography

Search Result 25, Processing Time 0.022 seconds

Defect Evaluation for Weld Specimen of Bogie Using Infrared Thermography (적외선 서모그래피를 이용한 대차 용접시편의 결함 평가)

  • Kwon, Seok Jin;Seo, Jung Won;Kim, Jae Chul;Jun, Hyun Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.619-625
    • /
    • 2015
  • There is a large interest to find reliable and automatic methods for crack detection and quantification in the railway bogie frame. The non-destructive inspection of railway bogie frame has been performed by ultrasonic and magnetic particle testing in general inspection. The magnetic particle method has been utilized in the defect inspection of the bogie frame but the grinding process is required before inspection and the dust is developed resulting from the processing. The objective of this paper is to apply the inspection method of bogie frame using infra-red thermography. The infra-red thermography system using the excitation of eddy current was performed for the defect evaluation of weld specimen inserted artificial defects. The result shows that the infra-red thermography method can detect the surface and inner defects in weld specimen for bogie frame.

Heat Transfer Measurement in a Supersonic Flowfield by an Infra-red Thermography (적외선 측정 기법을 이용한 초음속 유동내 열전달 측정)

  • Yu, Man-Sun;Yi, Jong-Ju;Song, Ji-Woon;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.359-362
    • /
    • 2006
  • Infra-red thermography was conducted to understand a heat transfer characteristic on a surface protruded to a supersonic flowfield. Surface temperature distribution was obtained under the constant heat flux condition with a infra-red camera and the convective heat transfer coefficient distribution was calculated. Finally, two dimensional distribution of heat transfer coefficient on a surface around a cylinder body was derived.

  • PDF

Test Research Using an IR Thermography Technique in a Supersonic Wind Tunnel (초음속 풍동에서의 IR Thermography 기법을 활용한 시험연구)

  • Kim, Ikhyun;Lee, Jaeho;Park, Gisu;Byun, Yunghwan;Lee, Jongkook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.99-107
    • /
    • 2016
  • Test research on Infra-Red Thermography(IRT) technique in a supersonic wind tunnel has been conducted. Inadvertent technical difficulties and their solutions associated with the technique in running of the facility were examined. Two flow conditions at Mach number of 3 and 4 were considered. A double compression ramp model, that replicates realistic high-speed vehicle configuration, was used as test model. The present IR data were compared with shadowgraph visualization images and laminar computational fluid dynamics(CFD) results. It has been shown that the IRT technique can be used in quantifying various fluid dynamic features such as flow transition, separation and three-dimensional phenomena around the double compression ramp model.

Measurement of Temperature Field in the Primary Deformation Zone in 2-D Orthogonal Machining Using IR (Infra-Red) Thermography (순수 2 차원 절삭에서 적외선 열화상을 이용한 주변형 영역의 온도 분포 측정)

  • Kim, Myung-Jae;Jung, Hyun-Gi;Hwang, Ji-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.853-862
    • /
    • 2012
  • The present study develops a method for directly measuring the temperature field in the primary deformation zone with a high spatial resolution during 2-D orthogonal machining. This is enabled by the use of a high-speed, charge-coupled device (CCD) based, infra-red (IR) imaging system which allows characteristics of the temperature field such as the location and magnitude of the highest temperature and temperature gradient in the primary deformation zone to be identified. Based on these data, the relation between the machining temperature and the cutting conditions is investigated.

A Study of Heat Transfer in Supersonic Flow Field on a Sharp Fin Shape (Sharp Fin에 의한 초음속 유동장내 열전달 변화 연구)

  • Song, Ji-Woon;Yu, Man-Sun;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.371-374
    • /
    • 2006
  • Heat transfer characteristic near a sharp fin in a supersonic flow was studied. Infra-red thermography was used to obtain the variation of surface heat transfer coefficient distribution. The attack angle of fin is ranged from $10^{\circ}\;to\;20^{\circ}$ and the oil flow method was also conducted to understand a flow field near a sharp fin.

  • PDF

Effects of Hyeong points' Acupuncture of Three Foot-eum Collaterals on Abdominal Thermography of Healthy Human Beings (족삼음경(足三陰經) 형혈(滎穴) 자침(刺鍼)이 흉복부(胸腹部)의 체열변화(體熱變化)에 미치는 영향(影響))

  • Shin Jong-Keun;Kim Jae-Hyo;Park Sung-Sub;Park Kui-Jong;Kim Kyung-Sik;Sohn In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.4
    • /
    • pp.1-16
    • /
    • 2003
  • Objectives : This study was examined for effects of acupuncture of Hyeong points' Acupuncture of Three Foot-eum Collaterals on the abdominal thermography of health subject. Methods : The volunteers who participating in this study had taken rest for 20 - 30 minutes in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 minutes before, just before and 15 minutes after, 30 minutes after and 45 minutes after acupuncture stimulation. Acupuncture was applied to the left Hyeong points' Acupuncture of Three Foot-eum Collaterals for 30 minutes. Results : The results showed that acupuncture of Hyeong points had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of Hyeong points been increased comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, it was failed that acupuncture of Hyeong points could modulate the specific areas concerning to the abdominal pathway of Three Foot-eum Collaterals. Conclusions : These results suggest that acupuncture of Hyeong points may modulate thermal distributions and changes of abdominal areas including the below of chest.

  • PDF

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Characteristics of Acupuncture at ST36 on Facial Thermography of Health Subject (족삼리(足三里) (ST36) 자침(刺鍼)이 안면부(顔面部) 한열변화(寒熱變化)에 미치는 영향(影響))

  • Kim Yong-Tae;Kim Jae-Hyo;Hwang Jae-Ho;Kim Kyung-Sik;Sohn In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.13-33
    • /
    • 2002
  • This study was examined for effects of acupuncture of Zusanli (ST36) on the facial thermography in health subjects. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature (23-$25^{\circ}C$) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of face was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to the left ST36 for 30 mins. The results showed that acupuncture of ST36 significantly decreased the temperature of all the areas of facial surface comparing to those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of ST36 been increased significantly at the A1, A4, A6, A7 and A9 ROIs (region of interest) comparing that of control group. Observed the thermography classified by ROI, it was clear the fact that acupuncture of ST36 could modulate the specific areas concerning to the facial pathway of Stomach Meridian, because the thermal responses following acupuncture of ST36 were specific at the A1, A2, A5 and A9 ROIs, relatively. These results suggest that acupuncture of ST36 may modulate thermal distributions and changes of facial areas concerned with Stomach Meridian.

  • PDF