• Title/Summary/Keyword: Infra Red

Search Result 484, Processing Time 0.025 seconds

A Study on Multi-modal Near-IR Face and Iris Recognition on Mobile Phones (휴대폰 환경에서의 근적외선 얼굴 및 홍채 다중 인식 연구)

  • Park, Kang-Ryoung;Han, Song-Yi;Kang, Byung-Jun;Park, So-Young
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.2
    • /
    • pp.1-9
    • /
    • 2008
  • As the security requirements of mobile phones have been increasing, there have been extensive researches using one biometric feature (e.g., an iris, a fingerprint, or a face image) for authentication. Due to the limitation of uni-modal biometrics, we propose a method that combines face and iris images in order to improve accuracy in mobile environments. This paper presents four advantages and contributions over previous research. First, in order to capture both face and iris image at fast speed and simultaneously, we use a built-in conventional mega pixel camera in mobile phone, which is revised to capture the NIR (Near-InfraRed) face and iris image. Second, in order to increase the authentication accuracy of face and iris, we propose a score level fusion method based on SVM (Support Vector Machine). Third, to reduce the classification complexities of SVM and intra-variation of face and iris data, we normalize the input face and iris data, respectively. For face, a NIR illuminator and NIR passing filter on camera are used to reduce the illumination variance caused by environmental visible lighting and the consequent saturated region in face by the NIR illuminator is normalized by low processing logarithmic algorithm considering mobile phone. For iris, image transform into polar coordinate and iris code shifting are used for obtaining robust identification accuracy irrespective of image capturing condition. Fourth, to increase the processing speed on mobile phone, we use integer based face and iris authentication algorithms. Experimental results were tested with face and iris images by mega-pixel camera of mobile phone. It showed that the authentication accuracy using SVM was better than those of uni-modal (face or iris), SUM, MAX, NIN and weighted SUM rules.

Analysis of Animal Usage of Eco-bridge and Ecoduct Using an Infrared CCTV at the Baekdudaegan Mountain Range, Korea (적외선 CCTV를 활용한 백두대간 육교형 생태통로와 터널형 생태통로의 동물이용현황 분석)

  • Cho, Hye-Jin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.177-181
    • /
    • 2016
  • In order to prevent the fragmentation of animal habitat due to road construction, the most widely applied solution is building animal passes worldwide. In Korea, animal passes were introduced in the early 2000s, and through trial and error, the national guidelines for them and their design standards were published in 2010. These were criticized by politicians because of their relative inefficiency considering their high construction cost and their lack of animal usage. This study investigated the extent to which animals used the facilities. For this study, two types of animal passes, eco-bridges and ecoducts, were considered and the test sites were chosen from the Baekdu Mountains. The animal usage data was captured using infra-red CCTV cameras. The results showed that various types of animals used eco-bridges and ecoducts. Interestingly various types of birds were captured by cameras and endangered animals were also in them. The season, weather, and their surrounded vegetation also had effects on their usages. The infrared CCTV allowed detailed captures of animals but the electricity shortage was one disadvantage. During the last decades, a number of eco-bridges were constructed throughout the country and now we need to focus on their monitoring and maintenance for their successful efficiency and application.

Retrieval of Relative Surface Temperature from Single-channel Middle-infrared (MIR) Images (단일밴드 중적외선 영상으로부터 표면온도 추정을 위한 상대온도추정알고리즘의 연구)

  • Wook, Park;Won, Joong-Sun;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.95-104
    • /
    • 2013
  • In this study, a novel method is proposed for retrieving relative surface temperature from single-channel middle infra-red (MIR, 3-5 ${\mu}m$) remotely sensed data. In order to retrieve absolute temperature from MIR data, it is necessary to accommodate at least atmospheric effects, surface emissivity and reflected solar radiance. Instead of retrieving kinematic temperature of each target, we propose an alternative to retrieve the relative temperature between two targets. The core idea is to minimize atmospheric effects by assuming that the differential at-sensor radiance between two targets experiences the same atmospheric effects. To reduce effective simplify atmospheric parameters, each atmospheric parameter was examined by MODTRAN and MIR emissivity derived from ASTER spectral libraries. Simulation results provided a required accuracy of 2 K for materials with a temperature of 300 K within 0.1 emissivity errors. The algorithm was tested using MODIS band 23 MIR day time images for validation. The accuracy of retrieved relative temperature was $0.485{\pm}1.552$ K. The results demonstrated that the proposed algorithm was able to produce relative temperature with a required accuracy from only single-channel radiance data. However, this method has limitations when applied to materials having very low temperatures using day time MIR images.

NIS quality analysis of pre- and post-harvest sugarcane.

  • Johnson, Sarah E.;Berding, Nils
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1621-1621
    • /
    • 2001
  • The quality of sugarcane grown on the NE Australian tropical coast ($16^{\circ}$15'- $18^{\circ}$15' S Lat.) has declined markedly in the past seven years. This has been linked to dilution of mill-supply cane with increasing levels of non mature-stalk material consisting of leaves and sucker culms. The prime research objective was to examine the transition from the pre-harvest, in-field crop to harvested material sent for processing, in terms of quality and crop fraction proportions. A secondary objective was to quantify the effects of preharvest-season crop habit and culm condition on crop quality. Ten quadrat samples from each of 54 random crop sites (17 in 1999 and 37 in 2000), covering a wide range of variables (cultivar, crop class, and edaphic, topographic, climatic, and temporal factors) were collected immediately before harvest. Samples were partitioned into four fractions:- sound and unsound mature stalks (culms), sucker culms, and extraneous matter (leaves). Material harvested from each site was sampled and partitioned into four fractions:- sound and unsound billets (culm pieces), culm-spindle pieces, and leaf. In 2000, before harvest, 14 additional sites were sampled monthly, on three occasions, from March - June. Erect and non-erect culms were divided into sound and unsound classes. All samples were disintegrated and presented to a remote reflectance module of a scanning spectrophotometer using the BSES large cassette module. Near infra-red spectroscopic (NIS) analyses were developed for the rapid determination of quality components (Brix, commercial cane sugar (CCS), fibre, moisture, and polariscope reading). Calibrations for three material groups (culm (n = 639), non-culm (n = 496), and combined) were developed for all components using the 1999 data set. Two sub-sets (n = 178, and 190) of about 10% of the preharvest-season and harvest populations scanned in 2000 also were subjected to full routine laboratory analyses. The 1999 combined calibrations were excellent, but the culm calibrations produced consistently lower standard errors. Non-culm calibrations were marginally better than the combined for only CCS and pol. reading. Analysis of the 2000 culm data with calibrations using all 1999 and 2000 culm data resulted in better predictions relative to the 1999 culm calibrations. This also was true for the combined calibrations. Assessment of quality components in pre- and post-harvest sugarcane using NIS calibrations was more cost effective than using routine laboratory techniques. Outcomes from this NIS-facilitated research will have important economic consequences for the Australian sugarcane industry. Potential CCS present in mature culms is being discounted by dilution with leaves and sucker culms, threatening farm viability. The results question the efficacy of current harvesting technology. The CCS of harvested cane is improved only marginally over that of the in-field crop. Current harvesting technology requires either supplementary, innovative pre-mill processing or a design revolution to improve mill-supply cane quality, and therefore whole of industry economics. NIS-facilitated analyses, before the harvest season, highlighted the benefits of growing erect, sound crops. Loss of CCS then, can be minimized only by a combination of crop improvement and agronomic solutions, applied as part of sound on-farm management.

  • PDF

Effects of the low power He-Ne IR laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats (저에너지 He-Ne IR 레이저가 말초신경병증 당뇨쥐의 혈액화학 성분 변화에 미치는 영향)

  • Rho, Min-Hee;Kim, Jae-Young;Lee, Mi-Ae;Baek, Su-Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1033-1038
    • /
    • 2001
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red(He-Ne IR) laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dawley adult male rats were assigned to the 3 groups: the control group(N=7), the diabetic group(n=7) and the laser group(n=7). The diabetic group was induced with a single intravenous injecion of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental1asser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: 1. ALT was increased the laser treatment group than the diabetic group. but that was not significant. 2. AST was significantly increased the laser treatment group than the control group and the diabetic group. 3. LDH was significantly decreased the diabetic group and laser treatment group. 4. ALP was significantly increased the diabetic group and laser treatment group. 5. CHOL was significantly decreased the laser treatment group than the diabetic group. 6. TRIG was significantly increased the laser treatment group than the diabetic group. 7. CPK was significantly increased the laser treatment group than the control group and the diabetic group.

  • PDF

Growth and Optical Properties of PbSnSe Epilayers Grown on BaF2(111) (PbSnSe 단결정 박막의 성장과 광학적 특성)

  • Lee, Il-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.35-41
    • /
    • 2004
  • This study investigated the crystal growth, crystalline structure and the basic optical properties of $PbSnSe/BaF_2$ epilayers. The PbSnSe epilayer was grown on $BaF_2$(111) insulating substrates using a hot wall epitaxy (HWE) technique. It was found from the analysis of X-ray diffraction patterns that $PbSnSe/BaF_2$ epilayer was grown single crystal with a rock-salt structure oriented along [111] the growth direction. Using Rutherford back scattering, the atomic ratios of the PbSnSe was found to be proper stoichiometric. The best values for the full width at half maximum (FWHM) of the DCXRD was 162 arcsec for PbSnSe epilayer. The epilayer-thickness dependence of the FWHM of the DCXRD shows that the quality of the $PbSnSe/BaF_2$ is as expected. The dielectric function ${\varepsilon}(E)$ of a semiconductor is closely related to its electronic energy band structure and such relation can be drawn from features around the critical points(CPs) in the optical spectra. The real and imaginary parts(${\varepsilon}1$ and ${\varepsilon}2$) of the dielectric function ${\varepsilon}$ of PbSe were measured, and the observed spectra reveal distinct structures at energies of the E1, E2 and E3 CPs. These data are analyzed using a theoretical model known as the model dielectric function (MDF). The optical constants related to dielectric function such as the complex refractive index ($n^*=n+ik$), absorption coefficient (${\alpha}$) and normal-incidence reflectivity (R) are also presented for $PbSnSe/BaF_2$.

  • PDF

Study on the physical properties of nylon66/glass fiber composites as a function of extrusion number (나일론66/유리섬유 복합체의 압출횟수에 따른 특성 연구)

  • Lee, Bom Yi;Kim, Youn Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3990-3996
    • /
    • 2014
  • Because the physical properties can be decreased when a Nylon 66/glass fiber composite is injected into a mold over $300^{\circ}C$, a systematic study of the thermal history in the case of re-use is needed. Nylon 66/glass fiber extrudates as a function of the extrusion number were prepared using a twin screw extruder at 305/290/273/268/265/$260^{\circ}C$. The chemical structure, thermal properties, melt index, crystal structure, Izod impact strength, and rheological properties were measured by Fourier transform infra-red (FT-IR), melt indexer, DSC, TGA, XRD, Izod impact tester, and dynamic rheometer. The FT-IR spectra indicated that the number of extrusions did not affect the chemical structure. The decrease in molecular weight with increasing extrusion number was confirmed by the melt index and the complex viscosity of extrudates. Based on the DSC and TGA results, the thermal history had no effect on the melting temperature, regardless of the number of extrusions, but the degradation temperature decreased up to $20^{\circ}C$ with increasing extrusion number. The Izod impact strengths of the extrudates were found to decrease with increasing extrusion number. No structural change after extrusion was also confirmed because there was no change in the slope and shape of the G'-G" plot.

Effects of Sa-am Acupuncture Treatment on a ALS(Amyotrophic Lateral Sclerosis) Patient (근위축성 측삭 경화증 환자 1례를 대상으로 한 사암침법의 효과)

  • Lee, Sang-Mi;Kim, Sung-Ha;Jeong, Ho-Hyun;Park, Man-Yong;Lee, Jeong-Ju;Park, Ok-Ju;Lim, Jin-Young;Kim, Dong-Woung;Song, Bong-Keun;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.187-195
    • /
    • 2012
  • Objectives : Amyotrophic lateral sclerosis(ALS) is a progressive and incurable disease that causes degeneration of the motor neurons of the brain stem and spinal cord. The purpose of this study was to report the effectiveness of Sa-am acupuncture treatment on ALS patient. Methods : Following the stabilization period, a ALS patient respiratory figures(Et $C_{O2}$, Sp $_{O2}$, RR, pulse) were measured by using capnography & pulse oximetry for 30 minutes before acupuncture treatment. Acupuncture treatment such as lung tonification($SP_3(+){\cdot}LU_9(+){\cdot}HT_8(-){\cdot}LU_{10}(-)$), heart tonification($HT_9(+){\cdot}LR_1(+){\cdot}SI_8(-){\cdot}KI_{10}(-)$), liver tonification ($KI_{10}(+){\cdot}LR_8(+){\cdot}LU_8(-){\cdot}LR_4(-)$) were conducted for 5 days. Each Sa-am acupuncture treatment conducted at AM 7 : 00, AM 11 : 00, PM 4 : 30 of the day. During acupuncture treatment, the patient respiratory figures were measured equally for 30 minutes. The patient was treated by using Dong-bang acupuncture needles($0.30{\times}4.0$) and also stimulated using infra red. Results : The value of Et $C_{O2}$ has decreased more after Sa-am acupuncture lung tonification treatment than others. The value of pulse has decreased more after Sa-am acupuncture heart tonification treatment than others. The value of raspiration rate has decreased more after Sa-am acupuncture liver tonification treatment than others. And the value of Sp $O_2$ has increased more after Sa-am acupuncture liver tonification treatment than others. Conclusions : Although this study was subject to a few limitations, but it shows that Sa-am acupuncture treatment for ALS patients has a meaningful effect. This study needs to be developed further using a larger sample size to obtain more valuable and meaningful data.

The Preliminary Study on the Quantitative Analysis of Quarts by Fourier Transform Infrared Spectrophotometric Direct on Filter(FTIR-DOF) Method -Effects of filter materials, inhomogeneity of deposition, and humidity- (Fourier Transform Infrared Spectrophotometric Direct on Filter 방법을 이용한 석영 분석의 기초 연구 - 필터재질, 비균일 침착 및 습도의 영향 -)

  • Phee, Young Gyu;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Although the Fourier Transform Infra-Red spectrophotometric Direct on Filter(FTIR-DOF) method is a useful analytical technique for quantifying quartz content in respirable dust samples, a number of analytical problems must be taken into consideration such as, to name only a few, inhomogeneous deposition of particles, level of environmental humidity, uneven surface of the filter, and interfering minerals in the sample. This study was designed to select the most suitable wavelength and proper filter material for the method, and to investigate effects of humidity and inhomogeneous deposition of particles on the filter. Samples of respirable dust, created in a dust chamber containing standard material of quartz, were collected using a cyclone equipped with a 25mm filter as a collection medium. The results were as follows; 1. Among seven (7) commercially available filters tested for the FTIR-DOF method, the DM 800 filter showed the best analytical performance having the lowest background absorbance bands and no overlapping peaks at 799, 779, and $695cm^{-1}$. 2. The variations of absorbance due to humidity ranged from 1.0% to 3.3% for $799cm^{-1}$, 1.0% to 3.3% for $779cm^{-1}$, and 8.9%~20.9% for $695cm^{-1}$ peaks, respectively. The $699cm^{-1}$ peak was proved to be most vulnerble to environmental humidity for quantitative analysis of quartz. 3. As for effects of inhomogeneous deposition of samples, the highest variation of absorbance of 10.9% ($13.5{\mu}g$) was observed when using the 695cm-1. The variations of absorbance from the other two peaks, 799 and $779cm^{-1}$, ranged from 1.2 to 3.2%, and 1.4 to 4.1%, respectively. Therefore, the $799cm^{-1}$ peak was considered to be most reliable for quantitative analysis of quartz. The results of this study suggest that, for quantitative analysis of quartz in the respirable dust samples, use of the $799cm^{-1}$ peak can minimize the influence of environmental humidity and inhomogeneous deposition of particles on the filter. The FTIR-DOF method, if adopted for routine analysis of quartz in the respirable dust samples, could save sample preparation time and efforts substantially and also could increase analytical throughputs. Since use of the $799cm^{-1}$ peak is prone to be affected by interferences in the sample, further research on minimizing the effects is needed.

Real-Time Fixed Pattern Noise Suppression using Hardware Neural Networks in Infrared Images Based on DSP & FPGA (DSP & FPGA 기반의 적외선 영상에서 하드웨어 뉴럴 네트워크를 이용한 실시간 고정패턴잡음 제어)

  • Park, Chang-Han;Han, Jung-Soo;Chun, Seung-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.94-101
    • /
    • 2009
  • In this paper, we propose design of hardware based on a high speed digital signal processor (DSP) and a field programmable gate array (FPGA) for real-time suppression of fixed pattern noise (FPN) using hardware neural networks (HNN) in cooled infrared focal plane array (IRFPA) imaging system FPN appears a limited operation by temperature in observable images which applies to non-uniformity correction for infrared detector. These have very important problems because it happen serious problem for other applications as well as degradation for image quality in our system Signal processing architecture for our system operates reference gain and offset values using three tables for low, normal, and high temperatures. Proposed method creates virtual tables to separate for overlapping region in three offset tables. We also choose an optimum tenn of temperature which controls weighted values of HNN using mean values of pixels in three regions. This operates gain and offset tables for low, normal, and high temperatures from mean values of pixels and it recursively don't have to do an offset compensation in operation of our system Based on experimental results, proposed method showed improved quality of image which suppressed FPN by change of temperature distribution from an observational image in real-time system.