• Title/Summary/Keyword: Infra Red

Search Result 484, Processing Time 0.023 seconds

AKARI near-infrared spectral observations on the shocked H2 gas of a supernova remnant IC 443

  • Shinn, Jong-Ho;Koo, Bon-Chul;Seon, Kwang-Il;Lee, Ho-Gyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.69.1-69.1
    • /
    • 2010
  • IC 443 is famous for its interaction with nearby molecular clouds and intense H2 emission lines in infrared. Therefore, it has been studied extensively for the understanding of molecular shocks. We observed H2 mission lines toward the shock-cloud interaction regions of IC 443, known as clumps B, C, and G. The observations were performed with the InfraRed Camera (IRC) onboard a satellite AKARI over 2.5-5.0 um, where previous space observations, e.g. Infrared Space Observatory (ISO) and Spitzer, do not cover. Our AKARI observations provide spectra of sequential pure-rotational and ro-vibrational H2 emission lines. For the clumps C and G, combining with previous mid-infrared observational results, we found that the H2 level populations show a significant separation between v=0 and v=1 levels; v=1 levels are under-populated than v=0 levels, therefore, the population cannot be described by two temperature LTE model, as many people have analyzed for the shocked H2 gas. We also applied the thermal admixture model, dN(H2; T)~T^(-b) dT, with varying ortho-to-para ratios according to the temperature, to describe the level population, and obtained plausible ranges of the H2 gas density and power-law index b.

  • PDF

The ice features of Very Low Luminosity Objects (VeLLOs): Unveiling their episodic accretion history through the spectroscopic observation of AKARI IRC

  • Kim, Jaeyeong;Lee, Jeong-Eun;Aikawa, Yuri;Kim, Il-Seok;Lee, Ho-Gyu;Jeong, Woong-Seob;Noble, Jennifer A.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.45.3-46
    • /
    • 2018
  • Although mass accretion from the disk to the central protostar is a key process of low mass star formation, the accretion mechanism is still poorly understood. To investigate "episodic accretion", which has been suggested as an accretion mechanism in low mass star formation, we have carried out near-infrared spectroscopic observations of three very low-luminosity objects (VeLLOs) and one background source, using InfraRed Camera onboard the AKARI space telescope. The ice absorption features of $H_2O$, $CO_2$, and CO were detected around the wavelengths of 3.0, 4.26, and $4.67{\mu}m$, respectively. In addition, we revealed the XCN ice feature, which is attributed to high energy UV photons produced by the episodic burst accretion. The comparisons of the ice abundances of our targets with those of other YSOs observed previously with AKARI IRC imply that the three VeLLOs had experienced burst accretions although they are now in a very quiescent phase.

  • PDF

IRES Support Structure Design in a GEO Multi-Functional Satellite (정지궤도 복합위성의 적외선 지구센서 지지구조물 설계)

  • Park, Jong-Seok;Jeon, Hyung-Yoll;Kim, Chang-Ho
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.68-74
    • /
    • 2009
  • Infra-red earth sensors(IRES) are accommodated in a geostationary multi-functional satellite, which includes optical payloads for observing the earth, to provide pointing reference for the payloads. Even the slight pointing difference between the IRES and the payloads is so critical from the geostationary orbit that can degrade their imaging performance. Therefore, a dedicated support structure is required to guarantee the stability during the flight operation. This paper shows the design justification for the IRES support structure employed in the Communication, Ocean and Meteorological Satellite(COMS). It intends to give an overall design presentation and to justify that this design is compatible with all the requirements in terms of stiffness and strength as well as the stability.

  • PDF

Effects of Kyeong points' Acupuncture of Three Hand Yang Collaterals on Facial Thermography of Healthy Human Beings (수삼양경 경혈 자침이 안면부의 체열변화에 미치는 영향)

  • 임정아;김재효;김경식;손인철
    • The Journal of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.19-31
    • /
    • 2003
  • Objectives : This study examined effects of kyeong points (經穴)' acupuncture of three hand yang collaterals (手三陽經) on the facial thermography in health subjects, because the kyeong point in Yang collaterals belongs to the characteristic of the five elements (五行)meaning fire (火). Methods : The volunteers who participating in this study rested for 20-30 min. atroom temperature (23-$25^{\circ}C$) before the examination and were informed to avoid smoking, drinking and use of any drugsfor the previous day. The thermography of the face was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) at time intervals of 15 minutes : at 15 min before, just before and after, 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to the left kyeong points (經穴)' of three hand yang collaterals (手三陽經) for 30 minutes. Results : The results showed that kyeong points (經穴)' acupuncture of three hand yang collaterals (手三陽經) decreased the temperature of all the areas of the facial surface comparing to those of the control group. Also, it was observed that the quantities of thermal changes following acupuncture of ST36 increased in the all ROIs (regions of interest) compared to those of the control group. Conclusions : Observing the thermography classified by ROI, it was clear that acupuncture of kyeong points (經穴) of three hand yang collaterals (手三陽經) could modulate thermogram of the facial area however, it is necessary to undertake more investigation supporting these results.

  • PDF

Design of Interactive Teleprompter (인터렉티브 텔레프롬프터의 설계)

  • Park, Yuni;Park, Taejung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.43-51
    • /
    • 2016
  • This paper presents the concept of "interactive teleprompter", which provides the user with interaction with oneself or other users for live television broadcasts or smart mirrors. In such interactive applications, eye contacts between the user and the regenerated image or between the user and other persons are important in handling psychological processes or non-verbal communications. Unfortunately, it is not straightforward to address the eye contact issues with conventional combination of normal display and video camera. To address this problem, we propose an "interactive" teleprompter enhanced from conventional teleprompter devices. Our interactive teleprompter can recognize the user's gestures by applying infra-red (IR) depth sensor. This paper also presents test results for a beam splitter which plays a critical role for teleprompter and is designed to handle both visual light for RGB camera and IR for Depth sensor effectively.

A Study on the Characteristics of Sunglint in LongWave InfraRed Band (원적외선 대역의 태양 직사광 해수면 반사신호 특성 연구)

  • Kim, Kyung Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.306-314
    • /
    • 2018
  • In maritime environment, it is necessary to understand the characteristics of sunglint since it may degrade the target detection performance of the infrared sensor mounted weapons. In this paper, sunglint in LWIR band is modeled using the slope distribution of the sea surface, and is verified by comparing the radiance of a simulated result with that of the real world. According to the simulation, sunglint is critical when the solar zenith angle is over $60^{\circ}$. The peak radiance of sunglint grows as the solar zenith angle increases until it reaches $83^{\circ}$ and has a large difference depending on the solar zenith angle when the wind speed is small. Finally, seasonal and temporal characteristics of sunglint effects are analyzed. In summer, sunglint is dominant in the horizon near the solar azimuth right after sunrise and before sunset. However, in winter, the influence of sunglint lasts even during the daytime since the elevation of the sun is much lower than in summer.

A Study on the treatment of pain in oriental medicine (통증(痛症)의 한방치료(韓方治療)에 관(關)한 소고(小考))

  • Ryu, Kyung-Ju
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.454-484
    • /
    • 1996
  • There are many factors to evoke pain, for example cold, heat, seven emotion, digestion, fatigue, venemous worms, deficiency of blood etc., and its pathogenesis is complicated. Treatments for pain in oriental medicine are as follows. 1. Pharmacotherapy is a method to treat pain by different effects of herbal medicine, for example, regulating vital energy, activating blood circulation, eliminating phlegm, and dispelling the cold evil etc. 2. Acupuncture and moxibustion therapy is a kind of external application, it has a distinct effect in relieving pain. Recently its operation method has been more developed, so new acupuncture therapies are used in clinics. There are electroacupuncture, auricular acupuncture and injection of drugs at an acupuncture points etc. 3. Oriental physiotherapy is a treatment method to stimulate acupuncture points and meridians. (1) Hot pack, Paraffin bath, Microwave, Ultrasound, Short wave, Infra-red etc. are used to treat cold syndrome by dispersing cold by warming the channels. (2) E.S.T., I.C.T., T.E.N.S., S.S.P., cupping treatment etc. are used to treat disorders of vital energy. (3) Health ion, Carbon, T.D.P., etc are used to treat conic and deficiency syndrome.

  • PDF

The Insulation Test of Varnish (바니쉬의 절연성 평가)

  • Kim, Jeong-Hun;Shin, Beak-Chul;Kim, Sung-Pil;Lee, Soo-Woon;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.950-952
    • /
    • 1999
  • In this paper, we are studied a electrical properties study with P.D.GEORGE/STER LING Co. P.B 302-LV-2 POLYBUTADIENE RESIN which is used for VPI(Vacuum Pressure Impregnation)processing of field magnet and armature of traction motor in Korean national railroad at present was carried out its FT-IR (Fourier Transform Infra-Red) volume resistivity characteristics. The varnishes were experimented with the temperature range form $25[^{\circ}C]$ to $180[^{\circ}C]$ and applied voltage were supplied at 100, 250, 500, 1,000[V]. In this condition, the volume resistivity for specimens were measured. From the above study, the following data obtained for volume resistivity. It can be confirmed that velume resistivity with the increase of temperature is lower rapidly from room temperature to $130[^{\circ}C]$, and it is lower slowly at temperature higher than $130[^{\circ}C]$. Volume resistivity value is higher, according as the specimen is thick gradually. As the applied voltage is higher in the same temperature, volume resistivity value is lower.

  • PDF

DETECTION AND CLASSIFICATION OF DEFECTS ON APPLE USING MACHINE VISION

  • Suh, Sang-Ryong;Sung, Je-Hoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.852-862
    • /
    • 1996
  • This study was carried out to develop tools to detect defects of apple using machine vision. For the purpose, 6 kinds of frame for color images, R, G, B, h, S, and I frame, and a frame for near infra-red images (NIR frame) were tested first to select one which is useful to segment defect areas from apple images. After then, several methods to classify kind of defect for the segmented defect areas were developed and tested. Five kinds of apple defect -bruise , decay ,fleck worm hole and scar were investigated . The results are as follows: NIR frame was selected as the best one among the 7 kinds of image frame, and R, G and I frames showed favourable result to segment areas of apple defect. Various features of the segmented defect areas were measured to classify the defect areas. Eight kids of feature of the areas-size, roundness, axes length ratio, mean and variance of pixel values, variance of real part of spectrum, mean and variance of power spectrum resulted from spacial ourier transform were observed for the segmented defect areas in the selected 4 frames. then procedures to classify defects using the features were developed for the 4 frames and tested with 75-113 defects on apples. The test resulted that NIR and I frames showed high accuracies to classify the kind of defect as 77% and 76% , respectively.

  • PDF

INTRODUCTION OF AOCS HARDWARE CONFIGURATION FOR COMS

  • Park, Young-Woong;Park, Keun-Joo;Lee, Hoon-Hee;Ju, Gwang-Hyeok
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.207-210
    • /
    • 2007
  • A part of the big differences between LEO(Low Earth Orbit) and GEO(Geostationary Earth Orbit) satellite is that transfer orbit is used or not or what tolerance of the position on the mission orbit is permitted. That is to say, the transfer orbit is not used and the constraint of orbit position is not adapted on LEO satellite. Whereas for GEO satellite case, the transfer orbit shall be used due to the very high altitude and the satellite shall be stayed in the station keeping box which is permitted on the mission orbit. These phases are functions for AOCS mission. The aim of this paper is to introduce the AOCS hardware configuration for COMS (Communication, Ocean and Meteorological Satellite). The AOCS hardware of COMS consist of 3 Linear Analogue Sun Sensors (LIASS), 3 Bi-Axis Sun Sensors (BASS), 2 Infra-Red Earth Sensors (IRES), 3 Fiber Optical Gyroscopes (FOG), 5 momentum wheels and 14 thrusters. In this paper, each component is explained how to be used, how to locate and what relation between the AOCS algorithm and these components.

  • PDF