• 제목/요약/키워드: Information of emission

검색결과 1,312건 처리시간 0.025초

POLYCYCLIC AROMATIC HYDROCARBON (PAH) MOLECULES IN THE DISKS AROUND LOW MASS STARS

  • Kim, Kyoung Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제40권2호
    • /
    • pp.36.1-36.1
    • /
    • 2015
  • We present $5-14{\mu}m$ Infrared Spectrograph spectra of 14 T Tauri stars which show Polycyclic Aromatic Hydrocarbon (PAH) features and reside in 0.7 pc from ${\Theta}_1$ Ori C. The spectral types of nine out of 11 stars have spectral type information, with types ranging from K7-M5. These stars do not supply strong enough UV photons to excite PAH emission in their disks. Therefore, we consider the detection of PAH emission in disks around low mass stars illuminated by an external source of UV photons, namely, from Trapezium OB association, including ${\Theta}_1$ Ori C. The morphological features of PAH emission from most disks around K-M type host stars are unique, not belonging to any known classes of PAH features. We found that the PAH emission strengths decrease as the projected distance of the objects from ${\Theta}_1$ Ori C increase. We suggest future far-IR and submm/mm observations for better understanding of the characteristics and distribution of PAHs in these disks.

  • PDF

Characteristics an Circuit Model of a Field Emission Triode

  • Nam, Jung-Hyun;Ihm, Jeong-Don;Kim, Jong-Duk;Kim, Yeo-Hwan;Park, Kyu-Man
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권5호
    • /
    • pp.129-133
    • /
    • 1997
  • A circuit model for a field emission triode has been proposed. The model parameters have been extracted from he fabricated silicon tip array and verified by comparing with the results simulated by circuit simulator(SPICE). The cut-off frequency can be calculated from the parametric capacitance and the transconductance values extracted from measurements. For the field emission triode, the capacitance of 3.45fF/tip and the transconductance of 0.94nS/tip have been measured under the emission current of 4.1nA/tip. From these values, the cut-off frequency is predicted to be 43 kHz but th measured one came out to be 6 kHz. because o the parasitic capacitance components.

  • PDF

Energy Transfer between Activators at Different Crystallographic Sites

  • Sohn, Kee-Sun;Lee, Sang-Jun;Lee, Bong-Hyun;Xie, Rong-Jun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.239-242
    • /
    • 2009
  • $Sr_2Si_5N_8:Eu^{2+}$, one of the most recently developed phosphors for use in white light emitting diodes, exhibits a two-peak emission. Namely, the emission band of $Sr_2Si_5N_8:Eu^{2+}$ is deconvoluted into two Gaussian peaks irrespective of the $Eu^{2+}$ concentration. We examined the two-peak emission of $Sr_2Si_5N_8:Eu^{2+}$ by analyzing the time-resolved photoluminescence spectra. We revealed that the two-peak emission was closely associated with the energy transfer taking place between $Eu^{2+}$ activators located at two different crystallographic sites in the $Sr_2Si_5N_8$ structure. The experimental results coincided well with the rate equation model involving the crystallographic information of the host.

  • PDF

A Study on the Radiated Emission from the DC Power-Bus for the PCB (PCB DC Power-Bus로부터의 전파 방사에 관한 연구)

  • Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제17권2호
    • /
    • pp.148-151
    • /
    • 2006
  • The DC power-bus' resonance is frequently attributed to EMI sources in the PCBs. Subsequently, it will ruin the digital signal integrity within one system or between adjacent systems in the form of conducted or radiated emission. Hence, since it is of importance to examine the PCB's emission, this paper sheds a light on the radiated emission from the power-bus with regards to its resonance modes. A full-wave analysis method is used to calculate the impedance and radiated electric fields and is validated by physics and an EM analysis tool.

Measurement of Electrical Insulating Oil Oxidation by Evaluating the UV Fluorescence Emission Ratio (자외선 형광 방출비 평가에 의한 전기 절연유의 산화측정)

  • Wicaksono, Britantyo;Kong, Hosung;Han, Hung-Gu
    • Tribology and Lubricants
    • /
    • 제29권1호
    • /
    • pp.51-55
    • /
    • 2013
  • In this work, a new fluorescence emission measurement technology was introduced and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate it for the oil oxidation measurement of electrical insulating oil. The oxidation characteristics of insulating oil were found to be fairly represented by the titration method and IR spectroscopy, and the results are comparable to a change in the fluorescence emission ratio that is defined as the shift in fluorescence intensity in the measured wavelength range. The result also shows that by the measurement of fluorescence emission ratio, it is possible to detect the oxidation of oil relatively earlier than by other methods. This study suggests that the developed technology can provide sufficient information for evaluating the insulating oil quality, and that the developed FER sensor can be used as an effective condition monitoring device of electrical insulating oil oxidation.

A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation (전자의료기기의 전자파 적합성 평가에 관한 연구)

  • Song, C.G.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF

Silicon field emission arrays coated with a $CoSi_2$ layer grown by reactive chemical vapor deposition

  • Han, Byung-Wook;Rhee, Hwa-Sung;Ahn, Byung-Tae;Lee, Nam-Yang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.131-132
    • /
    • 2000
  • We prepared Si emitters coated with a MOCVD $CoSi_2$ layer to improve the emission properties. The $CoSi_2$ layer was grown on Si field emitters in situ by reactive chemical-vapor deposition of cyclopentadienyl dicarbonyl cobalt at 600 ${\sim}$ $650^{\circ}C$. The $CoSi_2$ coated field emitters showed enhanced emission properties of current-voltage characteristics, which were due to the increase of emitting area from Fowler-Nordheim plot. And the emission current fluctuation decreased due to the chemically stable surface properties of $CoSi_2$.

  • PDF

A study on the radiated emission from the DC power-bus for the PCB (PCB DC power-bus로부터의 전파방사에 관한 연구)

  • Kahng, Sung-Tek
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.149-152
    • /
    • 2005
  • The DC power-bus' resonance is frequently attributed to EMI sources in the PCBs. Subsequently, it will ruin the digital signal integrity within one system or between adjacent systems in the form of conducted or radiated emission. Hence, since it is of importance to examine the PCB's emission, this paper sheds a light on the radiated emission from the power-bus with regards to its resonance modes. A full-wave analysis method is used to calculate the impedance and radiated electric fields and is validated by physics and an EM analysis tool.

  • PDF

Availability Analysis on Detection of Small Scale Gas Emission Facilities using Drone Imagery (드론영상을 이용한 소규모 가스 배출시설 탐지 가능성 분석)

  • Shin, Jung-Il;Kim, Ik-Jae;Hwang, Dong-Hyun;Lee, Jong-Min;Lim, Seong-Ha
    • Journal of Cadastre & Land InformatiX
    • /
    • 제47권1호
    • /
    • pp.213-223
    • /
    • 2017
  • Recently, the air quality of South Korea has deteriorated and public interest has been increasing. Various observation means are used for the monitoring of the atmospheric environment, but it relies on the experience and judgment of the observer in the absence of spatial information on the emission facilities. The purpose of this study was to determine the availability of using drones for monitoring air pollutant emission facilities. A texture transformation method was applied to the drone ortho image to detect the small gas emission facility and the slope data calculated by the digital surface model (DSM) was used to reduce the false alarm ratio. As a result, it shows the possibility of using drones in the detection of small gas emission facilities by showing about 80% of positive detection ratio and 40% of false alarm ratio. In the future, various researches are required to the improve positive detection ratio and the reduction of the false alarm ratio. Based on these results, it is necessary to construct a database including 3D spatial information of air pollutant emission facilities.