• Title/Summary/Keyword: Information Layer

Search Result 5,632, Processing Time 0.032 seconds

DIFFERENCE OF CALCIUM FLUORIDE FORMATION BETWEEN THE ENAMEL AND DENTIN AFTER FLUORIDE APPLICATION IN VITRO (불소적용시 법랑질과 상아질에서 불화칼슘형성의 차이에 관한 실험적 연구)

  • Kim, Jae-Gon;Kweon, Seon-Ja;Yun, Hyun-Du;An, Soo-Hyeon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.209-224
    • /
    • 1998
  • The purpose of this study was to compare the amount of calcium fluoride deposited on the enamel and dentin surface and to obtain information on the morphological change and crystallographic details of mineral deposition after 12,000ppm APF application in vitro. The bovine enamel and dentin blocks were randomly assigned to eight groups according to artificial caries lesion formation and difference of fluoride application time. The fluoride concentration and morphological characteristics on the treated enamel and dentin surface were investigated by using fluoride quantitative analysis and SEM. The powdered enamel and dentin of the intact bovine incisors were prepared for the X-ray diffraction analysis. The following results were obtained. 1. The amounts of KOH-soluble fluoride on the carious enamel and dentin surface after 24h APF application were higher than after only 5min APF application(p<0.05), but in the case of the sound enamel and dentin surface were similar after 5min and 24h application (P>0.05). The fluoride content was highly increased in the carious dentin as compared with sound dentin after APF application(P<0.05). 2. The carious enamel surface after APF application, the demineralized enamel surface were recovered a more dense enamel surface and precipitation of crystal was observed a distintive surface layer of spherical globules of about 1 m diameter. In the case of the fluorided carious dentin surface, precipitation of calcium fluoride-like material was deposited both inside the dentinal tubules as well as in the intertubular regions. 3. The crystallographic structure of powdered enamel and dentin after 24h APF application had large crystallities of apatite and CaF2 diffraction peaks in the enamel as compared with dentin. The diffraction data collected from the 27.50-29.50(2) angular range of the powdered enamel, the (105) apatite, (225) apatite and (111) CaF2 peaks of the enamel crystallities were detected after 24h APF application.

  • PDF

Standardization of Hydration in the Stratum Corneum Using by Polyols (폴리올을 이용한 각질층 수분량 측정의 표준화 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • The measurement of hydration level in the surface layer of the skin, stratum corneum (SC), gives important information on the biophysical properties and function of the skin barrier such as softness, flexibility, and healthiness of the skin. But it is difficult to measure a consistent hydration level from a sample to another sample due to individual variations and environmental changes. The aim of this study was to evaluate objective hydration after using various products in the SC. The SC Hydration was measured by capacitance (Corneometer$^{(R)}$, C+K, Germany) on the ventral site of forearm from 40 healthy volunteers. The skin surface was chronologically measured immediately after application of the test products and 3 and 6 hours later. We analyzed the averages of five measurements of each site and used the hydration increase rate for correction on untreated site variation. We found that most polyols including glycerol and butylenes glycol influenced directly the hydration increase rate in the SC previously. In this study, glycerol was used to prepare the standard products from 0 to 20 percents and applied to the same volunteers. The individual standard curve showed linear relation to glycerol concentrations. Based on the the standard curve, hydration of SC was converted into hydration increase rate to glycerol concentrations. The converted glycerol concentrations of products were repetitive and reproducible. In addition, the individual standard curve was used to relate the skin type of each individual. These results suggest that the hydration of the SC standardized regardless of external variation and individual skin condition can explain detailed skin state variation. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with other methods for noninvasive measurement.

Correlation interpretation for surface-geophysical exploration data-Chojeong Area, Chungbuk (지표물리탐사 자료의 상관해석-충북 초정지역)

  • Gwon, Il Ryong;Kim, Ji Su;Kim, Gyeong Ho
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.75-88
    • /
    • 1999
  • A recent major subject of geophysical exploration is research into 3-D subsurface imaging with a composite information from the various geophysical data. In an attempt to interpret Schlumberger sounding data for the study area in 2-D and 3-D view, resistivity imaging was firstly performed and then pseudo-3-D resistivity volume was reconstructed by interpolating several 1-D resistivity plots. Electrical resistivity discontinuities such as fracture zone were successfully clarified in pseudo-3-D resistivity volume. The low resistivity zone mainly associated with fracture zone appears to develop down to granitic basement in the central part of the study area. Seismic velocity near the lineament is estimated to be approximately as small as 3,000 m/s, and weathering-layer for the southeastern part is interpreted to be deeper than for the northwestern part. Geophysical attributes such as electrical resistivity, seismic velocity, radioactivity for the Chojeong Area were analysed by utilizing a GIS software Arc/Info. The major fault boundaries and fracture zones were resolved through image enhancement of composite section (electrical resistivity and seismic refraction data) and were interpreted to develop in the southeastern part of the area, as characterized by low electrical resistivity and low seismic velocity. However, radioactivity attribute was found to be less sensitive to geological discontinuities, compared to resistivity and seismic velocity attributes.

  • PDF

Structural Study of Interface Layers in Tetragonal-HfO2/Si using Density Functional Theory (범 밀도함수론을 이용한 정방정계-HfO2/Si의 계면 층 구조 연구)

  • Kim, D.H.;Seo, H.I.;Kim, Y.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • We calculated tetragonal-$HfO_2$/Si superstructures using density functional theory. When a and b-axes of cubic-$HfO_2$ were increased to be matched with those of Si for epitaxy contact, c-axis was decreased by 2%. Eight models of interface layers were produced by choosing different terminating layers of tetragonal-$HfO_2$ and Si substrate at the interface. It was found that tetragonal-$HfO_2$ $(004)_{1/4}$/Si $(004)_{3/4}$ superstructure was the most favorable and tetragonal-$HfO_2$ (004)$_{1/4}$/Si (002) superstructure was the most unfavorable. In tetragonal-$HfO_2$ $(004)_{1/4}$/Si (002) superstructure, there were two oxygen vacancies in tetragonal-$HfO_2$ as two oxygen atoms were moved to Si substrate located at the interface.

Design of Multilayer Radome with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 다층 구조 레이돔 설계)

  • Lee, Kyung-Won;Hong, Ic-Pyo;Park, Beom-Jun;Chung, Yeong-Chul;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.744-751
    • /
    • 2010
  • In this paper, the design of multilayer radome within, the insertion loss, -0.3 dB in X-band with PSO was carried out based on two cases. The first is that, deciding material constant of skin and core, each layer thickness of c-sandwich radome with PSO is found and the second is that, deciding material constant and thickness of the skins of both sides, the material constant and thickness of three layers between skins of both sides using PSO is decided. The performance of the designed radome almost agreed with the required performance. It was showed that the radome design applying PSO algorithm is easy and fast and the optimum radome is also designed in combination of the various parameters of radome. From these results, the radome having various performance can be designed except the tedious calculation and also be applied to various radome structure.

Analysis of Block FEC Symbol Size's Effect On Transmission Efficiency and Energy Consumption over Wireless Sensor Networks (무선 센서 네트워크에서 전송 효율과 에너지 소비에 대한 블록 FEC 심볼 크기 영향 분석)

  • Ahn, Jong-Suk;Yoon, Jong-Hyuk;Lee, Young-Su
    • The KIPS Transactions:PartC
    • /
    • v.13C no.7 s.110
    • /
    • pp.803-812
    • /
    • 2006
  • This paper analytically evaluates the FEC(Forward Error Correction) symbol size's effect on the performance and energy consumption of 802.11 protocol with the block FEC algorithm over WSN(Wireless Sensor Network). Since the basic recovery unit of block FEC algorithms is symbols not bits, the FEC symbol size affects the packet correction rate even with the same amount of FEC check bits over a given WSN channel. Precisely, when the same amount of FEC check bits are allocated, the small-size symbols are effective over channels with frequent short bursts of propagation errors while the large ones are good at remedying the long rare bursts. To estimate the effect of the FEC symbol site, the paper at first models the WSN channel with Gilbert model based on real packet traces collected over TIP50CM sensor nodes and measures the energy consumed for encoding and decoding the RS (Reed-Solomon) code with various symbol sizes. Based on the WSN channel model and each RS code's energy expenditure, it analytically calculates the transmission efficiency and power consumption of 802.11 equipped with RS code. The computational analysis combined with real experimental data shows that the RS symbol size makes a difference of up to 4.2% in the transmission efficiency and 35% in energy consumption even with the same amount of FEC check bits.

Effect of Brine Treatment Applied in the Manufacture of Traditional Forged High Tin Bronzes of Korea (한국의 방짜유기에 가해지는 염수처리의 효과에 관한 연구)

  • Lee, Jae-Sung;Jeon, Ik-Hwan;Kwak, Seok-Chul;Park, Jang-Sik
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • The brine treatment applied during the fabrication of forged high tin bronze objects is considered effective at the removal of surface oxide layers developed at elevated temperatures. There is not much information, however, available for the understanding of its exact effect and purpose. This work performed laboratory experiments to characterize the effect brine treatments produce on the surface of bronze objects during fabrication. Specimens were first made in the bronze shop of the Yongin folk village under varying conditions of brine treatments, and the results obtained were then used in the following laboratory experiments where the effect of brine treatments were investigated in terms of brine concentrations, alloy compositions and thermo-mechanical treatments. The results show that oxide layers generated at high temperature are easily removed by the brine treatment. It was found that the element, chlorine, played a key role in the removal of such oxide layers as opposed to the other constituent of the brine, sodium, makes no notable contribution. In bronze alloys containing 22% tin, this brine effect is obtained regardless of the application of forging as long as the brine concentration is over 0.5% based on weight. In alloys containing lead, however, no brine effect is observed due to the molten lead that emerges from inside the hot bronze specimen and forms a thin layer on its surface.

Hybrid Mobile IP Protocol for Service Session Continuity between WiBro and HSDPA (WiBro와 HSDPA 망간 서비스 연속성을 제공하기 위한 Hybrid Mobil IP 프로토콜)

  • Kim, Sung-Jin;Choi, Woo-Jin
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.223-228
    • /
    • 2008
  • Recently, various types of wireless access networks, such as WLAN, WiBro and HSDPA, etc, have been successfully deployed by commercial service providers (i.e., KT, KTF). In this situation, there are many efforts to provide high quality of services to guarantee seamless mobility between heterogeneous networks. The IP layer mobility protocols are efficient mechanisms to provide seamless mobility between IP based heterogeneous networks as well as homogeneous networks. However, to apply IP mobility protocols in real heterogeneous networks (i.e., WiBro and HSDPA), we must consider not only the basic features of techniques of wireless access networks (i.e., Data rate, Coverage, Quality of Service) but also the problem of real environment of service provider (i.e., Expanse cost to change the access network). Due to this reason, it is difficult to satisfy required conditions by using only one IP mobility protocol in real heterogeneous networks. Therefore, in this paper, we propose an efficient mobility protocol to solve the complex problems that are occurred in real heterogeneous networks. The proposed protocol, so-called, "Hybrid Mobile IP" tries to provide a synergy effect by integrating Client Mobile IPv4 (CMIPv4) and Proxy Mobile IPv4 (PMIPv4), and using the two mobility protocols selectively according to the situation of real heterogeneous networks.

  • PDF

Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery (성형외과 영역에서 이물질 주사에 대한 고해상초음파 검사의 유용성)

  • Ko, Eung-Yeol;Sung, Ha-Min;Cho, Geon;Park, Young-Kyu;Tak, Kyoung-Seok;Suh, In-Suck;Yang, Ik
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.385-390
    • /
    • 2010
  • Purpose: The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body. Methods: From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12 MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal (7), foreign body removal and corrective plastic surgery (4), and conservative treatment with antibiotics and steroid injection (2). Results: High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared. Conclusion: Considering the usefulness of highresolution ultrasonography in foreign body injection, highresolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.

3dimension Topography Generation and Accuracy Analysis Using GIS (GIS를 이용한 3차원 지형도 생성 및 정확도 분석)

  • Nim Young Bin;Park Chang suk;Lee Cheol Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.2
    • /
    • pp.189-196
    • /
    • 2005
  • Recently as map making skills developed and as digital maps prevailed, peoples began to take interest in the realistic 3dimension topography rather than the flat 2 dimension one. The experiment is done by using the topographical information from the digital maps, To analyze the preciseness of this 3dimension topography, analysis of the coordinate-changed standard map image and the location errors of the plane and height from digital values of the map's topography by layers and features, were done. The visual results of locational values differed by every programs of coordinate transformation. Errors of locations also appeared from the methods of correcting the visual sources, when deciding the standard source's datum point. The plan's accuracy of the image data coordinate transformation is about ${\pm}4.1m$. In ground distance, therefore, it is included in the allowed error of the 1:25,000 scale changed map, satisfying the plan's accuracy. Also, by the use of reasonably spaced grid, it satisfied the visual topographical accuracy. Because the 3 dimension topographical map can be produced effectively and rapidly by using various scale's standard map image and the digital map, the further practical use of 3 dimension topographic map made by using the existing topographies and changed maps has high expectations.