• Title/Summary/Keyword: Influent river

Search Result 42, Processing Time 0.021 seconds

A Study on the Water Quality Affected by the Rainfall and Influent Rivers in Paldang Reservoir, Korea (강우 및 유입 하천수가 팔당호 수질에 미치는 영향분석)

  • Kim, Jongmin;Noh, Hyeran;Heo, Seongnam;Yang, Heejeong;Park, Jundae
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.277-283
    • /
    • 2005
  • This paper aimed to compare the daily water quality as well as the hydrological data gathered for the past two years (2000 to 2001) between the two influent rivers of Paldang reservoir. The analysis also has been carried out to draw out the factors that affect the water quality at the dam site, where the main drinking water drawing point is located. The relationship between total amount of monthly rainfall and monthly inflow showed $r^2=0.74$ (p<0.05). The highest peak of inflow of influent rivers recorded in August and September (in the year of 2000) and July and August (2001). Average inflows of influent rivers in 2000 and 2001 are calculated at 209.0, 161.5 CMS (Bughangang), 268.6, 148.2 CMS(Namhangang), and 7.8, 5.0 CMS (Gyeongancheon). The formula which was driven from the relationship between inflow and COD load of influent rivers, explained that COD concentration in general increased with the inflow. But during the rainy seasons (July, August, and September), COD concentration decreased according to the increase of inflow. The daily rainfall and COD concentration(or load) during the rainy season (August and September in the year of 2000, July and August in 2001) indicated that the peak of COD load correspond with the rainfall, which decreased sharply after 3 or 4 days. The reason was thought that the high COD load was diluted rapidly by the rain flow. Water temperature, pH and conductivity measured at dam site decreased obviously when the inflow sharply increased. Peak period of total phosphorus concentration coincided with that of inflow. In rainy season, chlorophyll-a concentration decreased obviously as the inflow increased. The reason can be ascribed to the flushing effect caused by the operation of floodgate.

Quantitative Determination of PFOA and PFOS in the Effluent of Sewage Treatment Plants and in Han River (서울시 하수처리장 방류수 및 한강 내 PFOA와 PFOS의 과불화화합물 모니터링 연구)

  • Shin, Mi-Yeon;Im, Jong-Kwon;Kho, Young-Lim;Choi, Kyoung-Sik;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.334-342
    • /
    • 2009
  • Perfluorinated compounds (PFCs) have a wide range of domestic and industrial applications, but they are persistent in the environment. Perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) are among the metabolites of PFCs and occur at high concentration in the environment. Korea is the largest importer of PFC compounds in the world, therefore, the accumulation of these compounds is possible. In this study, the concentrations of PFOS and PFOA were determined in water samples taken from sewage treatment plants (STPs) and the Han River in Seoul, Korea. After extraction with a HLB cartridge, PFCs in the samples were analyzed by HPLC with an ion trap mass spectrometry in electrospray negative mode. Limits of detection was between 1 and 1.6 ng/l. The result showed that the concentrations of PFOS and PFOA in effluent and influent of the four STPs in Seoul were 60~570 ng/l, and not detected (nd)~254 ng/l, respectively. The levels of PFOS and PFOA were higher in the effluents which passed through the treatment process than in influent water samples which was against expectation. The concentration of PFOA and PFOS in the Han River was 60~570 ng/l and nd~254 ng/l, respectively. PFOA was detected in every sample, but PFOS was only detected in the downstreams of the Han River. This result indicates that there is comprehensive contamination of PFCs in the aquatic environment in Korea.

Analysis of Optical Properties of Organic Carbon for Real-time Monitoring (유기탄소 실시간 모니터링을 위한 분광학적 특성인자 분석)

  • You, Youngmin;Park, Jongkwan;Lee, Byungjoon;Lee, Sungyun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.344-354
    • /
    • 2021
  • Optical methods such as UV and fluorescence spectrophotometers can be applied not only in the qualitative analysis of dissolved organic matter (DOM), but also in real-time quantitative DOM monitoring for wastewater and natural water. In this study, we measure the UV254 and fluorescence excitation emission spectra for a sewage treatment plant influent and effluent, and river water before and after sewage effluent flows into the river to examine the composition and origin of DOM. In addition, a correlation analysis between quantified DOM characteristics and dissolved organic carbon (DOC) was conducted. Based on the fluorescence excitation emission spectra analysis, it was confirmed that the protein-type tryptophan-like DOM was the dominant substance in the influent, and that the organic matter exhibited relatively more humic properties after biological treatment. However, DOM in river water showed the fluorescence characteristics of terrestrial humic-like and algal tyrosine-like (protein-like) organic matter. In addition, a correlation analysis was conducted between the DOC and optical indices such as UV254, the fluorescence intensity of protein-like and humic-like organic matter, then DOC prediction models were suggested for wastewater and river monitoring during non-rainfall and rainfall events. This study provides basic information that can improve the understanding of the contribution of DOC concentration by DOM components, and can be used for organic carbon concentration management in wastewater and natural water.

Comparison of Algal Growth Potentials in the Large Reservoirs and River Mainstream of Naktong River Watershed (낙동강 수계 대형 인공호 및 하천본류의 조류성장 잠재력 비교)

  • You, Kyung-A;Shin, Jae-Ki;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.138-144
    • /
    • 2006
  • Algal growth potential test (AGPT) has been used as a tool for assessing biological productivity potential in the aquatic ecosystems. This study was conducted to compare the productivity potentials of large reservoirs (Lakes Andong, Hapchon and Jinyang, and Naktong estuarine dam) and river sites (Sangju, Koryung, and Samlangjin) located in the Naktong River watershed. AGPT was conducted in both non-monsoon and mosoon season (February, April, July and September) of 2003, using Microcystis aeruginosa as a test alga. The AGPs in the reservoirs were relatively much lower than those of river sites. The river AGPs increased towards upstream close to the influent streams, while it generally decreased towards downstream. Immediately after the abrupt increase in influent discharge in summer, the AGP became similar between midstream and downstream sites. The water quality of river and reservoirs deteriorated during the drought period in accordance with AGP: it was the highest during this period. The AGPs showed the closest correlation with the P concentration, leading to the conclusion that bioavailable P is highly influential to the algal growth in both lentic and lotic ecosystems in the Naktong River watershed. Based on the AGPs, the water quality of tested sites was likely eutrophic. Our results suggest that AGPT be a useful tool in evaluating the productivity potential and trophic state of the water body as well as determining the nutrients that limit the growth of algae.

Evaluation on Environmental Bio-toxicity of Industrial Wastewater (산업폐수의 생물독성 발현에 관한 연구)

  • Kim, S.H.;Cheon, S.U.;Shin, K.S.;Jung, D.I.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants (하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향)

  • Lee, Tae-Hwan;Park, Min-Hye;Lee, Bomi;Hur, Jin;Yang, Heejeoug
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

Removal of Nitrate in River Water by Microorganisms in Saturated-Zone Soil: Laboratory-Scale Column Test (포화층 토양미생물에 의한 하천수의 nitrate 제거: 실험실규모 컬럼 실험)

  • Park, Jungyong;Ahn, Yeonghee
    • Journal of Life Science
    • /
    • v.24 no.5
    • /
    • pp.543-548
    • /
    • 2014
  • Aquifer recharge and recovery is a technology used to ensure a stable supply of clean water. During the process, river water is injected into a soil aquifer and stored. The stored water is then recovered and used to produce drinking water. It is important to understand quality improvement of the injected water while it is stored in the aquifer. In the present study, a lab-scale column reactor containing saturated-zone soil was employed to mimic an aquifer. The reactor was used to investigate microbial removal of nitrate that is a major inorganic contaminant detected in the Nakdong River. The reactor was introduced with river water that contained nitrate at concentrations (5.07, 6.81, 8.27, and 11.07 mg $NO_3{^-}/l$) detected downstream of the Nakdong River in the past 2 years. The nitrate concentrations decreased during the introduced water is retained in the reactor. Effluent from the reactor contained 1.49 mg $NO_3{^-}/l$ or less and had an average pH of 7.98 regardless of the nitrate concentrations of the influent. However abiotic control reactor showed similar nitrate-concentrations in its influent and effluent. Considering the result of abiotic control, the decreased nitrate concentration observed in the test column suggested that microorganisms in saturated-zone soil removed nitrate in the river water introduced into the reactor. Results of this study will be used to better understand microbial improvement of water quality in aquifer recharge and recovery technology.

Phosphorus Removal by DPAOs (Denitrifying Phosphorus Accumulating Organisms) in Aerobic Condition (호기 조건에서 DPAOs (Denitrifying Phosphorus Accumulation Organisms)에 의한 인 제거)

  • Jeong, No-Sung;Park, Young-Seek;Kim, Dong-Seog
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.62-66
    • /
    • 2010
  • This study was carried out to get phosphorus uptake rate in aerobic condition with nitrate and nitrite. Nitrate and nitrite inhibited phosphorus accumulating organisms' (PAOs') luxury uptake in aerobic condition. Nitrite awfully decreased the phosphorus uptake rate in aerobic condition. At the influent of 10 mg ${NO_3}^-$-NL, the phosphorus uptake was decreased to 52% comparing that at no influent of nitrate. And at the influent of 10 mg ${NO_2}^-$-NL, the phosphorus uptake was decreased to 28% comparing that at no influent of nitrite. At the influent of 20 mg ${NO_3}^-$-NL, nitrite and nitrate were co-existed and the phosphorus uptake rate was decreased to 16% comparing that at no influent of nitrite and nitrate. Also, the denitrification was occurred by denitrifying glycogen accumulating organisms (DGAOs)/denitrifying phosphorus accumulating organisms (OPAOs) in spite of aerobic condition, and the phosphorus uptake rate was increased by the decrease of influent nitrate concentration at the aerobic condition. The inflection point in the phosphorus uptake rate was shown at the nitrite concentration of 1.5~2 mg/L.

Evaluation of Pollutants Removal for Treated Wastewater Effluent and River Water by Meandering Constructed Wetland System (하수처리수와 하천수를 대상으로 한 생태적 수질정화 비오톱 시스템의 오염물질 제거에 대한 수질정화 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.131-139
    • /
    • 2012
  • Field experiment was performed from June 2010 to July 2011 to evaluate pollutants removal efficiency in the constructed wetland system for the treated wastewater and the river water. The wetland systems were constructed near Gyungan river. Two different systems with meandering shape were compared for seasonal base and operational period base. Several kinds of aquaculture are planted through the corridor of wetland system. Average removal rate of BOD, T-N and T-P for A system were 15.8%, 14.8% and 26.5%, respectively. Average removal rate of BOD, T-N and T-P for C system were 23.5%, 27.8% and 10.6%, respectively. The effluent from two wetland systems often exceeded effluent water quality standards for wastewater influent, however effluent water quality standards for river water. However, the wetland system can be useful to treat polluted river water and effluent from wastewater plant. Removal rate of pollutants in seasonal variation was the highest in summer for BOD and T-N, however the removal rates of T-P were higher in spring and autumn than in summer.

CHARACTERIZATION OF RECALCITRANT DISSOLVED ORGANIC MATTER IN LAKE AND INFLOW RIVER WATERS

  • Kim, Yong-Hwan;Lee, Shun-Hwa;Kim, Jung-Ho;Park, Jong-Woong;Choi, Kwang-Soon
    • Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.181-193
    • /
    • 2006
  • The hydrophilic or hydrophobic characteristics of dissolved organic matter (DOM) from different origins in lake and river waters were investigated using spectrometric and chromatographic analyses of water samples. DOM in a deep, mesotrophic lake (Lake Unmun) was fractionated using three types of ion exchange resins and classified into aquatic humic substances (AHS), hydrophobic neutrals (HoN), hydrophilic acids (HiA), hydrophilic neutrals (HiN), and bases (BaS). The DOM fractionation provided insight into the understanding of the nature of heterogeneous DOM molecules present in different water sources. The UV/DOC ratios were determined for samples from the influent river and lake waters during DOM fractionation and incubation. AHS prevailed over DOM in the lake and river waters. After biodegradation, the relative contribution of AHS in the total DOM became more significant. It indicates that the AHS fraction would increase while water stay long time in the lake.