하수처리장 유입수의 특성평가를 위한 실시간 수질예측 (Real-time Water Quality Prediction for Evaluation of Influent Characteristics in a Full-scale Sewerage Treatment Plant)

  • 김연권;채수권;한인선;김주환
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.617-623
    • /
    • 2010
  • It is the most important subject to figure out characteristics of the wastewater inflows of sewerage treatment plant(STP) when situation models are applied to operation of the biological processes and in the automatic control based on ICA(Instrument, Control and Automation). For the purposes, real-time influent monitoring method has been applied by using on-line monitoring equipments for the process optimization in conventional STP. Since, the influent of STP is consist of complex components such as, COD, BOD, TN, $NH_4$-N, $NO_3$-N, TP and $PO_4$-P. MRA2(Microbial Respiration Analyzer 2), which is capable of real-time analyzing of wastewater characteristics is used to overcome the limitations and defects of conventional online monitoring equipments in this study. Rapidity, accuracy and stability of developed MRA2 are evaluated and compared with the results from on-line monitoring equipments for seven months after installation in Full-scale STP.

Dr. Wastewater program의 적용을 통한 하수처리장 운전에 미치는 유입수 변동 영향평가 (Evaluation of influent changing effect on the STP performance using Dr. Wastewater)

  • 김연권;김홍석;서인석;김병균;한인선;김진상
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.647-655
    • /
    • 2008
  • Sewer Rehabilitation Project (SRP) is planed, designed and constructed to perform its intended performance as sewerage delivery systems. Recently, a subject of performance evaluation methodology development for SRP has become a great deal of concern among researchers in Korea. From the view point of Sewage Treatment Plant (STP), however, the estimation of improvement efficiency for SRP is in lack of reliability due to the fact that affections for the treatment efficiency and operating condition are not reflected on SRP design and construction. In this study, statistical methodology was used in the analysis of data, which are taken during 1,186 days ($1^{st}$ Jan. 2005 - $31^{th}$ Mar. 2008) from the influent, effluent and operating conditions of full-scale STP($25,000m^3/d$). Then the effect of SRP on the influent characteristics and operating conditions changing was compared and evaluated. Results from the statistical evaluation show that SRP causes characteristic changes in influent and exerts a significant effect especially on the performance of STP.

하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구 (A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur)

  • 문진영;황용우;백승륜
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.

CFD와 PIV test를 통한 장방형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of a rectangular secondary clarifier using CFD and PIV test)

  • 최영균;배강형;윤정환
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.41-50
    • /
    • 2010
  • The influent and effluent baffle configurations seriously affect the hydraulic characteristics of the secondary clarifier in wastewater treatment plant. In this study, those baffle configurations were optimized by computational fluid dynamics(CFD) analysis and particle image velocity(PIV) test in order to obtain uniform flow in inlet region and to minimize upflow velocity in outlet region of the secondary clarifier. Theoretical analysis using CFD showed that more uniform flow could be accomplished when the influent baffle was located closely to the inlet opening. Effects of effluent baffle configuration on the upflow velocity in the outlet region of the secondary clarifier were analyzed with four types of effluent baffles which are widely adopted for secondary clarifier design. From the CFD analysis, McKinney baffle(EB-2) was estimated to be the most effective for restraining the upflow velocity in the outlet region and these trends were identified by PIV tests. In addition, the McKinney baffle showed the most uniform overflow velocity distribution around the weir.

활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교 (Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process)

  • 이동근;성기문;정미라;박성주
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

대전시 공공하수처리시설 유입수 수질자료의 통계적 특성 및 추계학적 모의 (Statistical Characteristics and Stochastic Modeling of Water Quality Data at the Influent of Daejeon Wastewater Treatment Plant)

  • 박기정;정민재;이한샘;김덕우;윤재영;백경록
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.38-49
    • /
    • 2012
  • In this study, we analyze statistical characteristics of influent water quality in Daejeon waste water treatment plant and apply a stochastic model for data generation. In the analysis, the influent water quality data from year 2003 to 2008, except for year 2006, are used. Among water quality variables, we find strong correlations between BOD and T-N; T-N and T-P; BOD and T-P; $COD_{Mn}$ and T-P; and BOD and $COD_{Mn}$. We also find that different water quality variables follow different theoretical probability distribution functions, which also depends on whether the seasonal cycle is removed. Finally, we generate the influent water quality data using the multi-season 1st Markov model (Thomas-Fiering model). With model parameters calibrated for the period 2003~2005, the generated data for 2007~2008 are well compared with observed data showing good agreement in general. BOD and T-N are underestimated by the stochastic model. This is mainly due to the statistical difference in observed data itself between two periods of 2003~2005 and 2007~2008. Therefore, we expect the stochastic model can be applied with more confidence in the case that the data follows stationary pattern.

하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향 (Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants)

  • 이태환;박민혜;이보미;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

미생물 고정화를 이용한 산성염료의 처리 (Treatment of Acid dye Using Microbial Immobilization)

  • 김정목;조무환;양용운
    • 한국염색가공학회지
    • /
    • 제11권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Strains degrading and decolorizing acid dyes, Nylosan red E-BL 150%. were isolated from natural system, was named as ARK3. The optimal culture conditions of temperature and pH were $35^\circ{C}$, 7.0, respectively. Growth rate of cells in conditions of aerobic shaking more than standing culture conspicuously increased, and optical density of those to strain ARK3 were found as 1.38 and 0.25 after 42 hrs. Decolorization efficiency in batch culture which used as immobilization media to natural zeolite was 15% after 6 hrs, while suspension culture was 5%, also its of immobilization and suspension culture were 90% and 85% after 48 hrs, respectively. Decolorization efficiency of air-lift bioreactor was more than 90% to a dilution rate of $0.038hr^{-1}$, but that was decreased as 70%, when the dilution rate was $0.05hr^{-1}$. Even though at maximum dilution rate of this study, there was not appeared "wash out" phenomienon of biomass. Decolorization efficiency was 97.7% at a dilution rate of $0.025hr^{-1}$, when influent dye concentration was $100mg/\ell$. But if influent dye concentration increased as $150mg/\ell$, even though MLVSS increased, that of treatment water decreased as 93%. Also, when influent dye concentration increased as $200mg/\ell$ and $300mg/\ell$, decolorization efficiencies of treatment water abruptly decreased as 85% and 63%, respectively. Decolorization efficiency was more than 92% to the limit volumetric loading rate of $3.75mg/\ell\cdot{hr}$hr, without regard to variation of influent dye concentration or hydraulic retention time. if volumetric loading rate was more than $3.80mg/\ell\cdot{hr}$, at same condition, decolorization efficiency was lower decrease of retention time than increase of influent dye concentration.entration.

  • PDF

혼합폐수의 효율적인 처리를 위한 생물학적 처리공정 내의 미생물 군집 특성 분석 (Analysis of Microbial Community Structure for Effective Removal of Mixed Wastewater in Biological Wastewater Treatment)

  • 손형식;손희종;이상준
    • KSBB Journal
    • /
    • 제28권3호
    • /
    • pp.157-164
    • /
    • 2013
  • Depending on season, mixed wastewater can show great deviations in terms of the influent ratios of tannery and seafood-wastewater. Increases in the ratio of tannery wastewater in influent water also result in increases in the concentration of chromium, which decreases the ratio of BOD/T-N so that the removal efficiency of organic and nitrogen pollutants in biological wastewater treatment deteriorates. No substantial differences occur in the ratios of Eubacteria/total bacteria as the ratio between tannery wastewater and seafood wastewater changes in the influent water. In contrast, the cell numbers and activities of Eubacteria and total bacteria significantly decline with increasing ratios of tannery wastewater in the influent water. Stable removal of organic and nitrogen pollutants by biological wastewater treatments leads to dominance of Proteobacteria groups in all biological treatment basins. In aeration and oxic basins, ${\gamma}$-Proteobacteria account for approximately 21% of the Eubacteria groups, at $1.9{\times}10^9{\sim}2.0{\times}10^9$ cells/mL, while in an anoxic basin, ${\beta}$-Proteobacteria account for approximately 19% of the Eubacteria groups, at $1.3{\times}10^9$ cells/mL. However, a substantial decline in dominance of approximately 11% occurs for ${\gamma}$-Proteobacteria in aeration and oxic basins and about 1% for ${\beta}$-Proteobacteria in an anoxic basin. Mixed wastewater that undergoes extensive property changes of the influent water shows an efficiency of biological treatment that is greatly influenced by the ratio of dominant Proteobacteria groups.

반응표면분석법-중심합성계획을 이용한 최적 응집제 주입량 산정 연구 (Optimization of coagulant dosage using response surface methodology with central composite design)

  • 김예슬;오재일
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.193-202
    • /
    • 2015
  • The determining the appropriate dosage of coagulant is very important, because dosage of coagulant in the coagulation process for wastewater affects removing the amount of pollutants, cost, and producing sludge amount. Accordingly, in this study, in order to determine the optimal PAC dosage in the coagulation process, CCD (Central composite design) was used to proceed experimental design, and the quadratic regression models were constructed between independent variables (pH, influent turbidity, PAC dosage) and each response variable (Total coliform, E.coli, PSD (Particle size distribution) (< $10{\mu}m$), TP, $PO_4$-P, and $COD_{cr}$) by the RSM (Response surface methodology). Also, Considering the various response variables, the optimum PAC dosage and range were derived. As a result, in order to maximize the removal rate of total coliform and E.coli, the values of independent variables are the pH 6-7, the influent turbidity 100-200 NTU, and the PAC dosage 0.07-0.09 ml/L. For maximizing the removal rate of TP, $PO_4$-P, $COD_{cr}$, and PSD(< $10{\mu}m$), it is required for the pH 9, the influent turbidity 200-250 NTU, and the PAC dosage 0.05-0.065 ml/L. In the case of multiple independent variables, when the desirable removal rate for total coliform, E.coli, TP, and $PO_4$-P is 90-100 % and that for $COD_{cr}$ and PSD(< $10{\mu}m$) is 50-100 %, the required PAC dosage is 0.05-0.07 ml/L in the pH 9 and influent turbidity 200-250 NTU. Thus, if the influent turbidity is high, adjusting pH is more effective way in terms of cost since a small amount of PAC dosage is required.