• 제목/요약/키워드: Inflow effect

Search Result 506, Processing Time 0.026 seconds

Application of chemically enhanced backwash coping with algal inflow in desalination pretreatment using ceramic membrane (세라믹 분리막을 이용한 해수담수화 전처리 공정에서 조류 유입에 대한 유지세정 적용)

  • Kang, Joon-Seok;Park, Seo-Gyeong;Lee, Jeong-Jun;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.97-106
    • /
    • 2018
  • In this study, the effect of chemically enhanced backwash(CEB) coping with algal(Heterosigma Akashiwo) inflow was evaluated in the seawater desalination pretreatment process using ceramic membrane. In order to confirm the possibility of long-term filtration operation, the recovery rate of transmembrane pressure(TMP) due to the CEB using NaOCl was examined. When the membrane flow rate was 83.3 LMH, the TMP was maintained within 200 kPa for 84 hours in seawater influent. As the algal counts of 30,000 cell/mL were injected into the influent of seawater, however, the TMP rapidly increased and exceed maximum value. Membrane fouling caused by the algae was very poorly recovered by usual physical backwash. The CEB was performed for 30 min(3 min circulation / 27 min immersion) with 300 mg/L of NaOCl. As a result of the CEB application, it was possible to maintain a stable operating of filtration during 10 days and the average recovery rate of TMP by the CEB was 98.1%. It has been confirmed that the CEB using NaOCl is very effective in removal of membrane fouling by algae, resulted in stable membrane filtration for the long-term operation.

Design for a Low-Pressure Hydrocyclone with Application for Fecal Solid Removal Using Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.18 no.3
    • /
    • pp.180-188
    • /
    • 2005
  • The separation performances for thirty different dimensions of a low-pressure hydrocyclone (LPH) were tested in order to obtain an optimum dimension scale for fecal solid removal from an aquaculture system. The geometric variables were considered on two inlet diameters (Di: 30 and 50 mm), five overflow diameters (Do: 30, 50, 60, 70 and 100 mm), and three cylinder lengths (Lc: 250, 345 and 442 mm), while the cylinder diameter (Dc) of 335 mm, underflow diameter (Du) of 50 mm and cone angle (${\theta}$) of $68^{\circ}$ were kept constant. A small size for carp feces was regarded as the target for the removal of solids. Spherical polystyrene particles (1.1-1.3 mm dia., ${\rho}_s=1.05g/cm^3$), which demonstrate a similar settling velocity and specific gravity to the carp feces, were used as feed. The separation performance was tested in the range of 330 to 1200 ml/s of the inflow rate. Experimental results using ANCOVA and the Tukey test (${\alpha}=0.05$) demonstrated that the separation performances of LPH were significantly affected (P<0.05) by fi, Di and Do. In contrast, there was no significant Lc effect (P>0.05) on the separation performances. The maximum separation performance was detected at dimension combinations of 30 mm of inflow diameter (Di), 50, 60 and 70 mm of overflow diameter (Do), 345 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.03, 0.15-0.21 and 0.15 (or Di/Dc, Lc/Dc, Do/Dc and Du/Dc, respectively.

Inflow Noise Characteristics of the Sensor in Low Wave Number Region Using Transfer Function (전달함수를 이용한 저파수 영역에서의 센서 유입 소음 특성 연구)

  • Park, Ji-hye;Lee, Jongkil;Shin, Ku-kyun;Cho, Chi-yong
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.238-251
    • /
    • 2009
  • The noise itself that affects the sensor array is defined as the noise which happens in the place where the system is installed and the circumference noise which comes from the ocean. The array structure for detecting acoustic signal in the underwater effected turbulent layer flow noise. In this paper to design the conformal array spectral density function was introduced and several cases of flow induced noise which affect transfer function were simulated. Modified Corcos wall pressure model was used as turbulent boundary layer flow noise. The effect of noise has been reduced as integrated sum of transfer function has been reduced by decreasing elastomer thickness and density when kx is in low wave number area. Also the characteristics of transfer function by Corcos wall pressure displayed the product of frequency density function. This simulation results can be applied to the conformal array design in unmmaned underwater vehicle in the near future.

Effect of Hydroelectric Power Plant Discharge on the Turbidity Distribution in Dae-Cheong Dam Reservoir (발전방류구 위치변화에 따른 저수지내 탁수변화 -대청댐을 대상으로-)

  • Seo, Se-Deok;Lee, Jae-Yil;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.227-234
    • /
    • 2011
  • In the study, CE-QUAL-W2 was used and its examination and correction were conducted targeting 2001 and 2003 when the condition of rainfall was contradicted. Using the proved model in 2003, a scenario was implemented with management of locations for dewatering outlets and actual data for dam management in 1987 when inflow and outflow level were almost same. In case of the scenario which the location of dewatering outlets was 5m higher than usual location, exclusion efficiency for turbid water inflow at the beginning of precipitation was good. In case of the scenario which the location of dewatering outlets was 10m lower than usual location, exclusion efficiency for excluding turbid water remained in a reservoir after the end of precipitation. However, the scenario applying dam management data in 1987, exclusion efficiency was relatively low. In the scenario, power-generating water release spot at EL.57m for first four days after the beginning of precipitation, EL.52m for 5th to 8th and EL.42m from 9th days. An analysis of the scenario reveals that both excessive days exceeded 30 NTU and average turbidity levels were decreased comparing before and after the alteration on outlets. The average turbidity levels were decreased by minimum of 55% to maximum of 70% and 30NTU exceeding days were decreased by 45 days at maximum. Also, since it could exclude most of turbid water in a reservoir before the destatifcation, the risk for turbid water evenly distributed in a reservoir along with turn-over could be decreased as well.

The Investigation of Faunal Habitat Based on Ecological Rostoration of Urban Streams in Ulsan (울산시 도심하천의 생태하천 복원사업에 따른 동물상 서식실태 조사 분석)

  • Cho, Hong Je;Kang, Ho Seon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.5
    • /
    • pp.1-17
    • /
    • 2013
  • We researched the fauna restoration of 5 urban streams in Ulsan established as ecological streams by improving water quality and river environment. The fauna inhabitation were compared according to the conditions of geometrical feature such as river width, low-water channel width, ect and water quality, water volumn, inland and forceland. The Mugeo cheon has clearly shown the fauna restoration effects resulting from supplying sustainable maintenance water and wastewater treatments. In the Yaksa cheon, on the other hand, the restoration effects were low due to the inflow of wastewater and sledges in some part of stream ever though the improvement of water quality. The Yeocheon cheon was found to have disadvantage on the ecological inhabitations due to supplying the maintenance water with highly concentrated salinity. The fauna restoration effect of the Meongjeong cheon was low due to the inflow of wastewater to the down stream. Therefore by supplying the maintenance water and improving the connection to the Taehwa river at the estuary, better restoration effects could be observed. In the Cheokgwa cheon, which is almost a natural river, the ecological integrity of the fauna population has been maintained quite well. It was concluded that the project to transform urban streams into ecological streams should focus on not only keeping water volume and quality but also maintaining favorable conditions for the migration and settlement of animal species close to the natural state.

PIV Measurements of Rudder Inflow Induced by Propeller Revolution in Hull Wake (선체반류 중에서 작동하는 프로펠러에 의한 방향타 유입유동 PIV 계측)

  • Paik, Bu-Geun;Kim, Ki-Sup;Kim, Kyung-Youl;Kim, Gun-Do;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.2
    • /
    • pp.128-133
    • /
    • 2011
  • In the present study, the flow fields in between the propeller and the semi-spade rudder are investigated by using PIV technique to find out the influences of both simulated hull wake and propeller wake on the incident flow to the rudder. The velocity fields are measured at the propeller rotation angle of $180^{\circ}$ and the rudder deflection angles of $0^{\circ}$. Flow fields measured at each rudder deflection angle are analyzed in terms of angle-of-attack against the rudder leading edge. The hull wake increases the angle-of-attack more than that in the uniform inflow condition, forming the angle-of-attack of about $20^{\circ}$ at 0.7R(R=propeller radius) position. The distribution of the angle-of-attack is strongly affected by the stagnation point around the leading edge and camber effect of the rudder. These effects provide asymmetric distribution of angle-of-attack with respect to the leading edge of the rudder.

Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger (지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석)

  • Gil, Hu-Jeong;Lee, Kang-Ja;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation (수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Kim, Ju-Young;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Advection and Diffusion of Pollutant Inflow of Freshwater in Masan Bay (마산만에서의 담수 유입시 오염물의 이송 및 확산)

  • Yoo, Mim-Wook;Kim, Young-Do;Lyu, Si-Wan;Seo, Il-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.795-798
    • /
    • 2008
  • An estuary is very important that the seawater and the freshwater meet and they formed wide foreshore and estuarine which is used as the habitat of various living thing and spawning bed of fish. Masan bay is typical closing bay in Korea. It is located 9 km from the open sea and most inside of Jinhae bay. The width of bay entrance is less than 1 km, where the flow velocity is very low. The large scale industrial complex of Masan bay is located in near Masan and Changwon city whose population is about 100 million. Because of low tidal velocity, the pollutants from the land are accumulated, which makes the water quality worse in Masan bay. The purpose of this study is to analyze the various hydraulic characteristics using RMA-2 model. The advection and diffusion of pollutant is also simulated using RMA-4 model according to the inflow of Changwon-stream and Nam-stream. The hydraulic simulations include the effect of tide which can be characterized by the tide data of Masan bay tide observatory.

  • PDF

Projection of water temperature and stratification strength with climate change in Soyanggang Reservoir in South Korea (기후변화에 따른 소양호 수온 및 성층강도 변화 예측)

  • Yun, Yeojeong;Park, Hyungseok;Chung, Sewoong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.3
    • /
    • pp.234-247
    • /
    • 2019
  • In a deep lake and reservoir, thermal stratification is of great importance for characteristics of hydrodynamic mixing of the waterbody, and thereby influencesvertical distribution of dissolved oxygen, substances, nutrients, and the phytoplankton community. The purpose of this study, was to project the effect of a future climate change scenario on water temperature, stratification strength, and thermal stability in the Soyanggang Reservoir in the Han River basin of South Korea, using a suite of mathematical models; SWAT, HEC-ResSim, and CE-QUAL-W2(W2). W2 was calibrated with historical data observed 2005-2015. Using climate data generated by HadGEM2-AO with the RCP 4.5 scenario, SWAT predicted daily reservoir inflow 2016-2070, and HEC-ResSim simulated changes in reservoir discharge and water level, based on inflow and reservoir operation rules. Then, W2 was applied, to predict long-term continuous changes of water temperature, in the reservoir. As a result, the upper layer (5 m below water surface) and lower layer (5 m above bottom) water temperatures, were projected to rise $0.0191^{\circ}C/year$(p<0.05) and $0.008^{\circ}C/year$(p<0.05), respectively, in response to projected atmospheric temperature rise rate of $0.0279^{\circ}C/year$(p<0.05). Additionally, with increase of future temperature, stratification strength of the reservoir is projected to be stronger, and the number of the days when temperature difference of the upper layer and the lower layer becomes greater than $5^{\circ}C$, also increase. Increase of water temperature on the surface of the reservoir, affected seasonal growth rate of the algae community. In particular, the growth rate of cyanobacteria increased in spring, and early summer.