• Title/Summary/Keyword: Infiltration volume

Search Result 191, Processing Time 0.02 seconds

PCL Infiltration into a BCP Scaffold Strut to Improve the Mechanical Strength while Retaining Other Properties

  • Kim, Min-Sung;Kim, Yang-Hee;Park, Ih-Ho;Min, Young-Ki;Seo, Hyung-Seok;Lee, Byong-Taek
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.331-337
    • /
    • 2010
  • A highly porous Biphasic Calcium Phosphate (BCP) scaffold was fabricated by the sponge replica method with a microwave sintering technique. The BCP scaffold had interconnected pores ranging from $80\;{\mu}m$ to $1000\;{\mu}m$, which were similar to natural cancellous bone. To enhance the mechanical properties of the porous scaffold, infiltration of polycaprolactone (PCL) was employed. The microstructure of the BCP scaffold was optimized using various volume percentages of polymethylmethacrylate (PMMA) for the infiltration process. PCL successfully infiltrated into the hollow space of the strut formed after the removal of the polymer sponge throughout the degassing and high pressure steps. The microstructure and material properties of the BCP scaffold (i.e., pore size, morphology of infiltrated and coated PCL, compressive strength, and porosity) were evaluated. When a 30 vol% of PMMA was used, the PCL-BCP scaffold showed the highest compressive strength. The compressive strength values of the BCP and PCL-BCP scaffolds were approximately 1.3 and 2MPa, respectively. After the PCL infiltration process, the porosity of the PCL-BCP scaffold decreased slightly to 86%, whereas that of the BCP scaffold was 86%. The number of pores in the $10\;{\mu}m$ to $20\;{\mu}m$ rage, which represent the pore channel inside of the strut, significantly decreased. The in-vitro study confirmed that the PCL-infiltrated BCP scaffold showed comparable cell viability without any cytotoxic behavior.

Performance Evaluation of Soil Media for Water Quality Purification at LID Application (분산형 빗물관리시설 적용을 위한 수질정화기능 여재 성능 평가)

  • Park, Chan Gi;Kim, Chun Soo;Kim, Hwang Hee;Yoo, Sung-Yeol;Jeon, Ji Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.85-91
    • /
    • 2014
  • In this study, the water quality purification of new medias which were NPS media, hyugato, mineral stone, charcoal for applying soil media of Integrated Management Practices (IMPs) of Low Impact Development (LID) were evaluated. The influent concentrations of COD, T-N, and T-P were 117.8 mg/L, 17.1 mg/L, and 2.062 mg/L, respectively. The infiltration capacities of NPS media, hyugoto, mineral stone, charcoal, and gravel were $7.1{\times}10m/s$, $7.3{\times}10^{-5}m/s$, $7.9{\times}10^{-5}m/s$, $6.0{\times}10^{-5}m/s$, respectively. All media meet criteria of infiltration capacity as surface soil layer at IMPs which is over $1.0{\times}10^{-5}m/s$. Maximum removal rates of COD, T-N, and T-P occurred at Charcoal with 98 % of COD removal rate, NPS with 78 % of T-N removal rate, and hyugato with 75 % fo T-P removal rate, respectively. For more high removal efficiency of all water quality item, the mixed media which is 4.5(NPS media): 1(charcoal) : 4.5 (hyugato) as volume ratio was evaluated. The infiltration capacity of mixed media was $7.9{\times}10^{-5}m/s$ and met the criteria of infiltration as surface soil layer. The water quality removal efficiencies of mixed media were very high with showing 70 % for COD, 85 % for T-N, and 71 % for T-P. The mixed media could purify the water quality of surface runoff and was recommended to used at the LID site of ground water quality problem.

Fabrication and Characteristics of $Al_2O_{3p}$/AC8A Composites by Pressureless Infiltration Process (무가압함침법에 의한 $Al_2O_{3p}$/AC8A 복합재료의 제조 및 특성)

  • 김재동;고성위;정해용
    • Composites Research
    • /
    • v.13 no.6
    • /
    • pp.1-8
    • /
    • 2000
  • The fabrication Process of $Al_2O_{3p}$/AC8A composites by pressureless infiltration technique and the effects of additive Mg content and volume fraction of particulate reinforcement on mechanical and wear properties were investigated. It was found that the bending strength decreased with increasing volume fraction of $Al_2O_{3p}$ particles. Whereas hardness increased with volume fraction of $Al_2O_{3p}$ particles. The decrement of strength in case of high volume fraction of $Al_2O_{3p}$ particles was attributed to high porosity level. In terms of additive Mg content, $Al_2O_{3p}$/AC8A composites containing around 5~7wt% of additive Mg indicated the highest strength, and hardness values increased with additive Mg contents. Wear resistance of AC8A alloy were improved by reinforcement of $Al_2O_{3p}$ particles especially at high sliding velocity. Wear property of $Al_2O_{3p}$/AC8A composites and AC8A alloy exhibited different aspects. $Al_2O_{3p}$/AC8A composites indicated more wear loss than AC8A alloy at slow velocity region. However a transition point of wear loss was found at middle velocity region which shows the minimum wear loss and wear loss at high velocity region exhibited almost same value as at slow velocity region, whereas wear loss of AC8A alloy almost linearly increased with sliding velocity. It was found that $Al_2O_{3p}$/AC8A composites containing $Al_2O_{3p}$ volume fraction of 20% exhibited abrasive wear surface regardless of sliding velocity and $Al_2O_{3p}$/AC8A composites containing $Al_2O_{3p}$ volume fraction of 40% showed slightly adhesive wear surface at low sliding velocity, and it progressed to severe wear as increasing the sliding velocity.

  • PDF

Evaluation of the Volume and Pollutant Reduction in an Infiltration and Filtration Facility with Varying Rainfall Conditions (침투여과시설의 강우계급에 따른 유량 및 비점오염물질 저감 효과 분석)

  • Yu, Gigyung;Choi, Jiyeon;Kang, Hee-Man;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.30-35
    • /
    • 2016
  • Urban areas generate large amounts of stormwater and non-point source (NPS) pollutants during rainfall events. These are caused by various land use runoffs, vehicular and human activities and increased impervious cover. The increased runoff and NPS pollutants cause water quality deterioration in the receiving waters and adversely affect the aqua-ecosystem. These environmental impacts could be reduced through the application of low impact development (LID) techniques. In Korea, more than 80% of the total rainfall occurs in summer and most of these were 10 mm or less. Therefore, if the LIDs developed were able to cope with rainfall of 10 mm and below, NPS management could be efficiently conducted. This research was performed to determine the effect of varying amounts of rainfall on the performance capability of an established infiltration and filtration facility (IF facility) that can be applied to Korea's common rainfall ranges. The IF facility area was 1.75% of the catchment area, however the facility treated more than 40% and 60% runoff volume and pollutant reduction respectively for a 10 mm rainfall. Lastly, higher volume and pollutant reduction could be attained when the LID area was at least 2% of the entire catchment.

Optimizing Electrical and Mechanical Properties of Reaction-Sintered SiC by using Different-Sized SiC Particles in Preform

  • Jeon, Young-Sam;Shin, Hyun-Ho;Park, Jin-Soo;Kang, Sang-Won
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.8
    • /
    • pp.439-442
    • /
    • 2008
  • A series of reaction-sintered SiC was fabricated from preforms with varying volume fractions of two resin-coated SiC particles of different sizes (63 and $18{\mu}m$). The electrical resistivity and mechanical strength were eventually optimized at the small particle volume fraction of $0.3{\sim}0.4$, at which point the porosity of the preform was minimized. This study experimentally proves that additional processes after the formation of the preform, such as silicon infiltration and reaction sintering, do not apparently alter the optimum volume fraction of the preform packing, predicted by an existing analytical model based on solid packing. Thus, the volume fraction of particles of different sizes can be determined practically through the solid packing model to fabricate RSSCs with optimal properties.

Evaluation of the Performance of Woodchip-filled Infiltration Trench Treating Stormwater from Highway (고속도로 강우유출수 처리를 위한 우드칩 충진 침투도랑의 성능평가)

  • Park, Kisoo;Kang, Heeman;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.183-193
    • /
    • 2016
  • In this study, design and performance of infiltration trench using woodchip as media for treating stormwater from highway were examined through field monitoring. Average reduction efficiency for TSS, COD, BOD, TN, and TP was 88%, 94%, 85%, 80%, and 75% respectively, which is similar to values reported by other studies and design manuals even though direct comparison is not possible due to different monitoring and design conditions. Mean field infiltration rate estimated by measuring the change of water depth inside the observation well was about 40mm/hr, and the time taken for complete infiltration was about 0.83days, which corresponds well with design criteria recommended by MOE guidelines in Korea. In addition, according to analysis of infiltration rate and reduction efficiency, effective rainfall depth applied for determining water quality volume(WQv), 5mm was found to be properly established as design criteria. Woodchip must be considered and included as an alternative media together with crushed rock and gravel into the design guidelines because it has more advantages in terms of weight, porosity, cost, and easiness of management than other media materials.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Ground water in the four major basins in Korea (사대강유역의 지하수)

  • 최승일
    • Water for future
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 1979
  • Ground water stored in the alluvium and the rocks provides the vase flow of the streams and can be withdraw from wells and infiltration galleries. And it is also recharge naturallyby precipitation. The amount of ground water in the four major basins it is estimated to be about 137,000 million cubiv meters(Table1), while nationwide ground water storage to be about 232,000 million cubic meters. The estimation of storage volume has been made on the basis of assumed thickness of the saturated zone of the different rocks and assumed porosities of those rocks. The values of the porosity of alluvium and saprolite were assumed to be 25% and 40% respectivvely which are based on tests made of similar materials in Georgia, U.S. The volume of water in storage is believed to be a conservative estimate. Detailed geologic and hydrologic investigation should be made where and when water resources are needed.

  • PDF

A Study on the alternative daily cover and envelop materials of PS Ball slag (PS Ball 풍쇄슬래그의 일일복토재 및 집배수재 재활용을 위한 연구)

  • Kim, Sang-Keun;Chung, Ha-Ik;Song, Bong-Jun;Chang, Won-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1408-1411
    • /
    • 2005
  • The purposes of daily cover are to control odor and volatile organic compound emissions, to control litters, to mitigate rainfall infiltration. Under usual operation of landfill, the soil layer of 15cm thick is used for daily cover, but about $20{\sim}$25% of landfill capacity is consumed by daily cover volume. Considering our limited land and difficulty in getting landfill site, developing an alternative daily cover material which usually occupies much less volume than soil will be very significant. Also, if we can use waste material for alternative daily cover, we can get additional benefit of recycling waste.

  • PDF

Neuroprotective Effects of Boyanghwano-tang on Intracerebral Hemorrhage-Induced Rats Using Immunohistochemistry (보양환오탕(補陽還五湯)이 흰쥐 뇌출혈 손상에 미치는 영향에 대한 면역조직화학 연구)

  • Cha, Jae-Deog;Lee, Joon-Suk;Shin, Jung-Won;Kim, Seong-Joon;Kang, Hee;Sohn, Nak-Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.5
    • /
    • pp.799-806
    • /
    • 2011
  • This study was performed in order to evaluate the neuroprotective effect of Boyanghwano-tang (BYT) water extract on intracerebral hemorrhage (ICH). ICH was induced by the stereotaxic intrastriatal injection of bacterial collagenase type IV in Sprague-Dawley rats. BYT was orally given once a day for 3 days after ICH. Hematoma volume and percentage edema were examined. As imflammatory markers, myeloperoxidase (MPO)-positive neutrophils infiltration and iNOS expression in the peri-ICH regions were examined using immunohistochemistry. As cellular damage markers, c-Fos, Bax, and HSP72 positive cells in the peri-ICH regions were measured also. BYT significantly reduced the hematoma volume and percentage edema of the ICH-induced rat brain. In the peri-hematoma regions, BYT significantly reduced MPO-positive neutrophil infiltration and iNOS expression of the ICH-induced rat brain. Additionally, BYT significantly reduced c-Fos, Bax, and HSP72 positive cells in the peri-hematoma regions of the ICH-induced rat brain. These results suggest that BYT plays a neuroprotective role against ICH through suppression of inflammatory responses, apoptosis and cellular damage.