• 제목/요약/키워드: Infiltration rates

검색결과 154건 처리시간 0.023초

Factors affecting the infiltration rate and removal of suspended solids in gravel-filled stormwater management structures

  • Guerra, Heidi B.;Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.67-74
    • /
    • 2019
  • Apparent changes in the natural hydrologic cycle causing more frequent floods in urban areas and surface water quality impairment have led stormwater management solutions towards the use of green and sustainable practices that aims to replicate pre-urbanization hydrology. Among the widely documented applications are infiltration techniques that temporarily store rainfall runoff while promoting evapotranspiration, groundwater recharge through infiltration, and diffuse pollutant reduction. In this study, a laboratory-scale infiltration device was built to be able to observe and determine the factors affecting flow variations and corresponding solids removal through a series of experiments employing semi-synthetic stormwater runoff. Results reveal that runoff and solids reduction is greatly influenced by the infiltration capability of the underlying soil which is also affected by rainfall intensity and the available depth for water storage. For gravel-filled structures, a depth of at least 1 m and subsoil infiltration rates of not more than 200 mm/h are suggested for optimum volume reduction and pollutant removal. Moreover, it was found that the length of the structure is more critical than the depth for applications in low infiltration soils. These findings provide a contribution to existing guidelines and current understanding in design and applicability of infiltration systems.

다층토양에서의 물과 공기의 움직임 (Water and Air Movement in Bounded Layered Soil)

  • 선우중호
    • 물과 미래
    • /
    • 제8권2호
    • /
    • pp.56-60
    • /
    • 1975
  • Traditional descriptions of water movement in soils and of calculations of infiltration rates neglect the air movement and its compressibility. The movement of two fluids in the bounded layered porous medium is treated analytically and computer simulations are conducted for given boundary conditions and initial saturation profiles. The movement of a given saturation across the interface between the different soil layers is theoretically developed by considering the conservation of mass. It is shown that the existence of the interface affects the infiltration rate when the average total velocity is greater than zero. The transition from one layer to another layer cause a change in the capillary drive and consequently influences the infiltration rate.

  • PDF

Shear infiltration and constant water content tests on unsaturated soils

  • Rasool, Ali Murtaza;Aziz, Mubashir
    • Geomechanics and Engineering
    • /
    • 제19권5호
    • /
    • pp.435-445
    • /
    • 2019
  • A series of element tests with different drainage conditions and strain rates were performed on compacted unsaturated non-plastic silt in unconfined conditions. Soil samples were compacted at water contents from dry to wet of optimum with the degree of saturation varying from 24 to 59.5% while maintaining the degree of compaction at 80%. The tests performed were shear infiltration tests in which specimens had constant net confining pressure, pore air pressure was kept drained and constant, just before the shear process pore water pressure was increased (and kept constant afterwards) to decrease matric suction and to start water infiltration. In constant water content tests, specimens had constant net confining pressure, pore air pressure was kept drained and constant whereas pore water pressure was kept undrained. As a result, the matric suction varied with increase in axial strain throughout the shearing process. In both cases, maximum shear strength was obtained for specimens prepared on dry side of optimum moisture content. Moreover, the gradient of stress path was not affected under different strain rates whereas the intercept of failure was changed due to the drainage conditions implied in this study.

단지개발에 있어 강수량 지하침투 증대를 위한 침투시설의 도입가능성 연구 -분당신도시 사례를 중심으로- (Increasing Infiltration with Pervious Drainage facilities -The Effect of Simulation in Bun-Dang New town, Korea-)

  • 김두하;박원규;안동만
    • 한국조경학회지
    • /
    • 제25권1호
    • /
    • pp.62-72
    • /
    • 1997
  • As a site is built up, runoff increases inevitably. This results in water deficit in the site and possible downstream flooding. It may cause irreversible site ecosystem disturbance. This study examined some techniques of increasing infiltration rates in a site development. The possible effects of applying such techniques at a new town development are calculated for four types of land uses-business area, low/high density residential areas, and park area- of Bun-Dang New Town. If the higher infiltration drainage systems are introduced, there may be additional infiltration of the precipitation as much as 59.8% in business area, 74.6% in low density residential area, 51.4% in high density residential area and 32.7% in park area. This much increase of infiltration, or decrease of runoff, may improve site water balance, and thus keep the site ecosystem much healthier.

  • PDF

개선된 여과형 시설의 비점오염물질 처리효율 평가 (Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System)

  • 강희만;최지연;김이형;배우근
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.161-169
    • /
    • 2011
  • 본 연구는 여과와 침투기작을 이용한 개선된 여과형 시설의 비점오염물질 처리효율을 평가하고자 수행되었다. 저감시설은 지리학적 기후학적인 인자를 고려하여 기존의 저감시설의 단점을 보완하여 설계되었다. 저감시설의 처리효율 평가는 실험실 규모로 수행되었으며, 3가지 유형의 유속[초기강우(120 mL/min), 일반적인 강우(242 mL/min), 집중호우(500 mL/min)]을 적용하여 실험을 진행하였고, 이를 통하여 수질 분석 및 물수지를 산정하였다. 실험결과, 저감시설의 입자상 물질 제거 효율은 90%이상으로 높게 분석되었다. 3가지의 유속변화 실험 중, 집중호우의 경우에서 11~91% 범위로 낮은 제거효율을 보였는데, 이는 다른 유속에 비해 짧은 체류시간을 갖기 때문으로 판단된다. 또한 저감시설의 물수지 산정결과 침투량은 유출량의 약 1%에 불과하여 향후 저감시설 설계 시, 침투를 증가시키기 위해서 시설하부의 토양치환 등을 통한 침투량 및 저류량을 증가시킬 수 있는 기술적 접근이 필요하며, 이는 오염물질의 저감에 크게 기여할 것으로 판단된다.

모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구 (Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length)

  • 김승재;박종준;김영일
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

돈분액비 토양침투율과 토양내 분포 특성 (Infiltration Rates of Liquid Pig Manure with Various Dilution Ratios in Three Different Soil)

  • 심호영;이교석;이동성;전대성;박미숙;신지수;이연경;구지원;김수빈;송승근;정덕영
    • 한국환경농학회지
    • /
    • 제33권3호
    • /
    • pp.164-168
    • /
    • 2014
  • BACKGROUND: Increase in application of liquid pig manure(LPM) in agriculture as nutritional source has become a social issue due to its influence on water quality. Also, proper application methods have not been developed with respect to indigenous properties of LPM and soil physical properties. Therefore, we conducted this experiment to observe the infiltration characteristics and distribution of dissolved organic compounds of LPM in soils having different soil textures. METHODS AND RESULTS: To do this experiment, we collected three different soils and LPM. We analyzed the physical and chemical properties of both soils and LPM to determine the dilution ratios of LPM. The LPM diluted to 4 different ratios with distilled water was applied to the top of soil column. Infiltration rates were observed by time and depth until the amount of effluent collected from the bottom of the soil columns were stabilized while maintaining the hydraulic head 3 cm above the soil column. The results showed that infiltration rates increased with increasing dilution ratios in the order of sandy, loamy sand, and sandy loam. The time required to reach steady state was increased with decreasing sand contents clay. CONCLUSION: The size and amount of the dissolved organic compounds in LPM that can determine the efficiency as fertilizer and environmental problems as nonpoint pollution source in water quality have not been investigated with respect to behavior and transport of them in soil. Therefore, it requires further research how we can properly apply LPM as valuable fertilizer substitute for inorganic fertilizers.

감마나이프 수술 환자의 정위적 틀 고정을 위한 침윤 마취 시 통증 완화 중재의 효과 (The Effect of Pain Relieving Intervention During Infiltration among Gamma Knife Surgery Patients for Stereotactic Frame Fixation)

  • 장영준;김현옥
    • 대한간호학회지
    • /
    • 제48권2호
    • /
    • pp.221-231
    • /
    • 2018
  • Purpose: This study aimed to compare the effects of three interventions on pain, blood pressure, and pulse rate during infiltration anesthesia in patients about to undergo gamma knife surgeries. Methods: The three interventions employed in a university-affiliated Hospital in J City, South Korea were as follows: EMLA cream plus Vapocoolant spray (Vapocoolant, n=30), EMLA cream plus 10.0% Lidocaine spray (Lidocaine, n=30), and EMLA cream only (EMLA, n=30). The equivalent control-group pre test - post test study design was used. Pain was assessed subjectively using the numeric rating scale (NRS) and objectively using a Galvanic Skin Response (GSR) tester. NRS scores were assessed after infiltration anesthesia and the GSR was assessed during infiltration anesthesia. Blood pressure and pulse rate were assessed twice: before and after infiltration anesthesia. Data were collected between August 3, 2016 and March 24, 2017. Results: NRS scores after infiltration anesthesia and the GSR during infiltration anesthesia were significantly lower in the Vapocoolant group than in the Lidocaine and EMLA groups (F=13.56, p<.001 and F=14.43, p<.001, respectively). The increase in systolic blood pressure (F=4.77, p=.011) and in pulse rates (F=4.78, p=.011) before and after infiltration anesthesia were significantly smaller in the Vapocoolant group than in the Lidocaine and EMLA groups; however, no significant differences were observed in diastolic blood pressures (F=1.51, p=.227). Conclusion: EMLA cream plus Vapocoolant spray was the most effective intervention to relieve pain and to lower increase in systolic blood pressure and pulse rate caused by infiltration anesthesia for stereotactic frame fixation. Thus, application of Vapocoolant spray in addition to EMLA cream is highly recommended as a nursing intervention for patients undergoing gamma knife surgeries.

산지유역의 초과우량 추정 모형 (Rainfall Excess Model for Forest Watersheds)

  • 남선우;최은호
    • 물과 미래
    • /
    • 제23권3호
    • /
    • pp.351-361
    • /
    • 1990
  • 식생계로 피복되고 투수성 토양을 갖는 산지유역에서의 점유출량 결정을 위해 초과우량 추정모형을 유도하였다. 산림에 의한 canopy차단 및 풀, 낙엽, 농작물 등에 의한 지표피복차단저축을 고려하고, 유역 포화시의 증발산량을 계산하여 관측강우로부터 지표 흙에 도달되는 순강우량을 결정하였다. 부정강우사상에 적용할 수 있도록 수정된 Green-Ampt모형으로부터 침투율을 결정하여 초과우량을 산정하였고, IHP 대표시험유역 가운데 장평유역의 실제호우사상에 적용하여 손실율, 유출율 및 유출발생시간 등을 결정, 적용성 여부를 검토하였다.

  • PDF

하수관거보수 순위결정을 위한 침입수/유입수량에 대한 정량/정성 분석의 실행 연구 (A Quantitative/Qualitative Study of Infiltration/Inflow for Order Decision of Sewer pipe Maintenance)

  • 박명균;김대성;안원식;오정미
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.53-62
    • /
    • 2006
  • This study was carried out to obtain quantities of infiltration, inflow and exfiltration on sewer pipes of three areas at a small city. From the results, the most investigated sewer pipes should be infiltrated by underground water and undetermined water. Flowrate commonly showed two peak at 6 to 8 a.m. and 6 to 9 p.m. and which may be influenced by the sewer flowrate with washing or bathing time. BOD/TN ratio of below 4.0 were inferior as compared with proper criteria 5.1. Infiltration/inflow rates of three areas were 21.7% and $0.08m^3/km$ of A, 12.4% and $0.015m^3/km$ of B, 22.4% and $0.021m^3/km$ of C, respectively. This indicates that infiltration/inflow rate of A was obviously greater than that of B and C. Also, these results show that we can conduct sewer maintenance in good order as A, C and B zone.