An Experimental Study of Window Air Tightness according to Filling Piece Shapes (창호 풍지판 형상에 따른 기밀성의 실험적 연구)

  • Yun, Yura;Park, Jong-Jun;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • To study the effect of installation and the shapes of filling pieces used for windows on the infiltration rate, infiltration tests were performed with two types of sliding windows and two shapes for the filling pieces. Infiltration occurred most at the top and bottom parts of the center location where two windows overlap, indicating the necessity of a filling piece to be installed at these locations. Infiltration velocity is proportional to the square root of the pressure difference, complying well with the theoretical correlation. Infiltration is reduced about 50% by the filling piece installation. This study shows that filling pieces are essential and their shapes play significant roles in reducing the infiltration of windows.

Estimation Method of Infiltration Capacity for Assessment of Drainage Capacity II (배수성능 평가를 위한 침투능 산정기법에 관한 연구(II))

  • Jeong, Jisu;Shim, Jeonghoon;Lee, Dong Hyuk;Hwang, Youngcheol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.23-28
    • /
    • 2020
  • As a result of a suite of laboratory tests undertaken to suggest a rational method for the estimation of infiltration capacity, it is found that the infiltration rate tends to increase as the soil unit weight decreases while it tends to increase as the rainfall intensity increases. Comparative analyses for infiltration curves employing the reduction constant of initial infiltration capacity (α coefficient) that was suggested in this study has reasonably captured the time dependent variation of infiltration capacity. Consequently this study has presented an experimental model for the estimation of infiltration capacity to improve the Horton infiltration capacity curve that has been widely used for estimation of the infiltration capacity and amount of infiltration for its application to sandy soils.

Fundamental Study about Bottom-Clinging Rate in Free Floating Larva by Infiltration Flow in Tidal (조석의 침투류에 의한 패류 유생의 착저 (着底) 효과에 관한 기초적 연구)

  • Back, Sang-Ho;Park, Kwang-Jae;Park, Young-Je;Cheon, Jun-Je;Cho, Kee-Chae;Kim, Yi-Un
    • The Korean Journal of Malacology
    • /
    • v.25 no.2
    • /
    • pp.97-103
    • /
    • 2009
  • It is a research that free floating larva of Ruditapes philippinarum in compliance with infiltration flow of tidal accumulation and bottom-clinging system in high density also, It is a precondition this for the continuous augmentation of Ruditapes philippinarum resources. So in flow field of tidal the free floating larva produced the infiltration water tank that can possibly bottom-clinging and experiment the water tank which uses free floating larva, It evaluates that the acceleration effect of free floating larva by infiltration in objective. As a result, 1) The experiment on free floating larva's bottom sediment grain diameter came to be high recording as bottom-clinging rate at the static water field and even biologically it selects bottom-clinging substrate it will be able to confirm. 2) About occurrence of infiltration flow field is in case of that: the drift of a current 10cm/s, bottom sediment grain 1.21mm infiltration flow 0.3cm/s increase of 3~5 times was confirmed. 3) From free floating larva of Ruditapes philippinarum the choice of bottom sediment grain diameter depends in the biological factor and form the flow field the bottom-clinging acceleration effect was controled over physical stable condition. 4) In case of density of Ruditapes philippinarum free floating larva of sea area, bottom sediment grain diameter, flow condition which are very cleanly in the research that possibly could conjecture the free floating larva's bottom-clinging rate.

  • PDF

Estimation of Proportion to Decentralized Rainwater Management Needed in Apartment Complex Development (공동주택단지 개발에서의 분산식 빗물관리 목표량 설정 - 택지개발사업지구 내 단지를 대상으로 -)

  • Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • The recent emphasis on ecological urban development has led to the need to maintain a hydrologic cycle in urban areas. As such, this study proposes decentralized rainwater management, a concept of onsite rainwater management that involves the utilization, infiltration, detention, and retention of rainwater. The main objective of this research is to estimate the proportion of decentralized rainwater management that is needed. From the research that was conducted in this study, it was found that the total runoff quantity increases by 10-20% after district lands are developed, when the probable rate of precipitation every 10 years is within this range. Thus, the runoff rate can be reduced by 10~20% of the total runoff quantity through decentralization. On the other hand, in the scale of housing complex development, the total runoff quantity increases by as much as 10~40% due to the changes in the rate of the impervious surface area. If 10-40% of the total runoff quantity was processed through decentralized rainwater management, the rate of infiltration, detention, retention, and runoff in precipitation prior to development could be recovered.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Water Balance Estimate of LID Technique for Circulating Urban Design (순환형 도시계획에 따른 LID기술의 물수지 분석)

  • Kang, Sung-Hee;Heo, Woo-Myung;Kang, Sang-Hyeok
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.1065-1073
    • /
    • 2015
  • Urbanization can be significantly affected the hydrologic cycle by increasing flood discharge and heat flux. In order to mitigate these modifications in urban areas, Low Impact Development (LID) technique has been designed and applied in Korea. In order to estimate runoff reduction rate using SWMM LID model, the characteristics of five LID techniques was firstly analyzed for water balance. Vegetated swale and green roof were not reduce flood discharge nor infiltration amount. On the other hand, porous pavement and infiltration trench were captured by infiltration function. The flood reduction rate with LID is substantially affected by their structures and properties, e.g., the percentage of the area installed with LID components and the percentage of the drainage area of the LID components.

Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery

  • Sawang, Kamonpun;Chaiyasamut, Teeranut;Kiattavornchareon, Sirichai;Pairuchvej, Verasak;Bhattarai, Bishwa Prakash;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 2017
  • Background: There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. Method: This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. Results: The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P<0.05). The duration of soft tissue anesthesia was longer in the DC group. The intra-operative pain was higher in the SC group with a significant (P < 0.05) requirement for a supplementary local anesthetic. Conclusion: We concluded that using DC for the infiltration injection had a higher success rate, longer duration of anesthesia, less intra-operative pain, and a lower amount of additional anesthesia than SC in the surgical removal of LITM. We recommend that a DC of 4% articaine and a 1:100,000 epinephrine infiltration in the retro-molar region can be an alternative anesthetic for LITM surgery.

Effect of Liquid Pig Manure on Growth of Rice and Infiltration Water Quality (돈분뇨 액비 시용이 벼 생육 및 침투수질에 미치는 영향)

  • Park, Baeg-Kyun;Lee, Jong-Sik;Cho, Nam-Jun;Jung, Kwang-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.3
    • /
    • pp.153-157
    • /
    • 2001
  • To evaluate the effect of liquid pig manure application, the growth and yield of rice and the quality of infiltration water were investigated with application of different amounts of liquid manure. At this study, liquid pig manure was treated with 100, 200, 300 and 400% of recommending nitrogen fertilizer level, respectively. Liquid manure with application rate more than 200% of recommending N fertilizer level (11kg) caused to increase of plant height and number of tiller at panicle formation stage, but it caused the plant disease and pest and plant lodging. In those treatment, number of panicles per hill and number of spikelets per panicle were increased, but yield of rice was less than chemical fertilizer treatment due to low rate of ripeness and 1,000 grain weight. $NO_3-N$ concentration in infiltration water sample collected at 90 cm of soil depth was increased with increasing application amount of liquid manure. With liquid manure application more than 200% of recommending N fertilizer level, it affected negatively on yield and environment such as groundwater quality.

  • PDF

Growth Characteristics of Kentucky Bluegrass on Different Rootzone Foundations (지반 유형에 따른 켄터키 블루그래스의 생육특성)

  • 이혜원;정대영;심상렬
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.6
    • /
    • pp.95-103
    • /
    • 2004
  • A turfgrass rootzone foundation is one of the important iufluences on the growth of cool-season turfgrass such as Kentucky bluegrass, which is usually grown on korean golf courses and athletic fields in Korea. This study was carried out to evaluate the growth of Kentucky bluegrass on 4 types of turfgrass root-zone foundations: a 2cm thickness of Sand 90%+Peat humus 8%+Zeolite 2% mixture on a subsoil base (C), a 20cm thickness of Sand 90%+Peat humus 8%+Zeolite 2% mixture (S), a 20cm thickness of Sand 45%+fine sand(a sort of Bomyungsa) 45%+Peat humus 8%+Zeolite 2% mixture (S+F), and a 20cm thickness of Sand 45%+fine sand(a sort of Bomyungsa) 45%+Peat humus 8%+Zeolite 2% mixture on a 20cm thick drainage layer (S+F(G)). Visual ratings of Kentucky bluegrass on the C foundation were low throughout the experiment when compared to S, S+F, and S+F(G) foundations, which contained high contents of sand with a high water infiltration rate. However, poor growth of Kentucky bluegrass in the summer of 1991 on the S foundation was likely to be caused by a too high water infiltration rate (185.8cm/hr). The growth of Kentucky bluegrass on the S+F(G) was good while the growth was a little weak at the developing stage on the S +F foundation. If the cost had to be considered when constructing golf courses and athletic fields, The S+F foundation without the drainage layer would be the best choice in terms of low cost and good quality of Kentucky bluegrass compared to the S+F(G). In this result, the infiltration rate was regarded as the most influential factor to the growth of Kentucky bluegrass on rootzone foundations.

Combining Four Elements of Precipitation Loss in a Watershed (유역내 네가지 강수손실 성분들의 합성)

  • Yoo, Ju-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.200-204
    • /
    • 2012
  • In engineering hydrology, an estimation of precipitation loss is one of the most important issues for successful modeling to forecast flooding or evaluate water resources for both surface and subsurface flows in a watershed. An accurate estimation of precipitation loss is required for successful implementation of rainfall-runoff models. Precipitation loss or hydrological abstraction may be defined as the portion of the precipitation that does not contribute to the direct runoff. It may consist of several loss elements or abstractions of precipitation such as infiltration, depression storage, evaporation or evapotranspiration, and interception. A composite loss rate model that combines four loss rates over time is derived as a lumped form of a continuous time function for a storm event. The composite loss rate model developed is an exponential model similar to Horton's infiltration model, but its parameters have different meanings. In this model, the initial loss rate is related to antecedent precipitation amounts prior to a storm event, and the decay factor of the loss rate is a composite decay of four losses.

  • PDF