• Title/Summary/Keyword: Infiltration analysis

Search Result 759, Processing Time 0.025 seconds

Three-dimensional Stability Analysis of Landslides in Unsaturated Soils: A Case Study (불포화 지반에서의 산사태 3차원 안정해석에 대한 사례연구)

  • Kim, Seong Jin;Oh, Seboong;Yoo, Young Geun;Shin, Ho Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.359-369
    • /
    • 2022
  • In slope stability analysis for landslides, mountains have various slopes and geographical features, and hence it is necessary to estimate stability using rigorous analysis methods. In this study, after the analysis of infiltration behavior through unsaturated layers due to rainfall, the stability of landslide was estimated to account for the variation of pore water pressures. In the analysis of slope stability, a three-dimensional slope analysis was compared with an infinite slope analysis in a case study of terrain in which an actual landslide occurred. In the three-dimensional slope stability analysis, it was found that the location of the failure and the failure area were predicted accurately based on the detailed geological information despite the variation of geographical features.

Stability Analysis and Reinforcement of Large Excavated Slope considering Precipitation Infiltration in Rainy Season (강우침투로 인한 대절취사면의 붕괴안정성검토 및 대책)

  • Chun, Byung-Sik;Choi, Hyun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.101-110
    • /
    • 2000
  • In case heavy rainfall is a key factor of slope failure, the failure zone is usually developed within the depth of 3~5m from the ground surface regardless of the location of the watertable. If rainfall is taken into consideration, it is general that the slope stability analysis is carried out under the assumption that the cut slope is saturated to the slope surface or the watertable elevates to a certain height so that ${\gamma}_{sat}$, the unit weight of saturated soil, is used. However, the analysis method mentioned above can't exactly simulate the variation of pore water pressure in the slope and yields different failure shape. The applicability of slope stability analysis method considering the distribution of pore water pressure within the slope with heavy rainfalls, was checked out after the stability analysis of a lage-scale cut slope in a highway construction site, where surface failure occurred with heavy rainfalls. An appropriate slope stabilization method is proposed on the base of the outcome of the analysis.

  • PDF

Application of multivariate statistics towards the geochemical evaluation of fluoride enrichment in groundwater at Shilabati river bank, West Bengal, India

  • Ghosh, Arghya;Mondal, Sandip
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.279-288
    • /
    • 2019
  • To obtain insightful knowledge of geochemical process controlling fluoride enrichment in groundwater of the villages near Shilabati river bank, West Bengal, India, multivariate statistical techniques were applied to a subgroup of the dataset generated from major ion analysis of groundwater samples. Water quality analysis of major ion chemistry revealed elevated levels of fluoride concentration in groundwater. Factor analysis (FA) of fifteen hydrochemical parameters demonstrated that fluoride occurrence was due to the weathering and dissolution of fluoride-bearing minerals in the aquifer. A strong positive loading (> 0.75) of fluoride with pH and bicarbonate for FA indicates an alkaline dominated environment responsible for leaching of fluoride from the source material. Mineralogical analysis of soli sediment exhibits the presence of fluoride-bearing minerals in underground geology. Hierarchical cluster analysis (HCA) was carried out to isolate the sampling sites according to groundwater quality. With HCA the sampling sites were isolated into three clusters. The occurrence of abundant fluoride in the higher elevated area of the observed three different clusters revealed that there was more contact opportunity of recharging water with the minerals present in the aquifer during infiltration through the vadose zone.

Field Experimental Analysis of Effects of Sediment Traps (현장실험을 통한 침사구의 효과 분석)

  • Choi, Kyungsook;Jang, Jeongryeol
    • KCID journal
    • /
    • v.21 no.1
    • /
    • pp.99-108
    • /
    • 2014
  • This study investigated the effects of NPS(non point source) pollution reduction of sediment traps through field experiments. Various sizes of 4 sediment traps were applied in a upland field located in Gunwi and assessed the infiltration and storage effects as well as NPS pollution reduction effects of this technique. The characteristics of deposited soil in the sediment traps were also analyzed including distribution of particle size, soil texture, and chemical properties. The results showed that slightly different composition of soil particle size from each sediment trap with high proportion of 0.15mm and 0.25mm ranges of soil particle diameters, while the loamy sand is the main types of deposited soils in the sediment traps. Decreased NPS pollution were observed from the water quality analysis of the samples taken from the sediment traps. Further research need to be proceeded continuously to improve this technique in order to utilize on upland fields for management of agricultural NPS pollutions.

  • PDF

A Study on the Simplified Energy Calculation Method of Apartment Houses (공동주택의 연료소모량 간이계산법에 관한 연구)

  • Lim, C.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.404-414
    • /
    • 1991
  • The purpose of this study is to compare the amount of heating, domestic hot water, and cooking fuel consumption with that of heating fuel consumption by the existing calculation method and to provide rational heating system design and energy conservation through presenting the simplified equation which can anticipate the amount of heating, domestic hot water, and cooking and the load mechanical equipments. The affecting factors to the amount of energy consumption are the case of Heating, Domestic Hot Water and Cooking in addition to the energy conservation intention.

  • PDF

The Performance Evaluation of C/SiC Composite for Rocket Propulsion Systems (추진기관용 C/SiC 복합재료의 특성 평가)

  • Kim, Yun-Chul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.433-438
    • /
    • 2009
  • The main objective of this research effort is to develop the performance of C/SiC composites manufactured by LSI (Liquid Silicon Infiltration) method for solid and liquid rocket propulsion system and ensure the performance analysis technique. The high performance and reliability of C/SiC composite are proved for solid and liquid rocket propulsion system. And the performance analysis technique related to mathematical ablation model is originated.

  • PDF

Finite Element Analysis for Performance Evaluation of the Seal in a Universal Joint Bearing (유니버설 조인트 베어링용 시일의 성능평가를 위한 유한요소해석)

  • Kim, Tae-Wan;Moon, Suk-Man;Koo, Young-Pil;Cho, Yong-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.140-146
    • /
    • 2001
  • Seals in a universal joint bearing are important components reinforcing lubrication performance by holding lubricant and preventing infiltration of dust, moisture, etc.. There is a great difference in seal performance according to seal shape and bonding position. Therefore, in this study, as for both the lip type seal and the O-ring type seal, FE analysis is conducted using Mooned-Rivlin Model. The results show that O-ring type seal does not have any effect of misalignment angle compared with lib type seal, which is more profitable.

  • PDF

FEM Analysis for Performance Evaluation of Seal in Universal Joint Bearing (유니버설 조인트 베어링용 Seal의 성능평가를 위한 유한요소해석)

  • 김태완;문석만;구영필;조용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.571-574
    • /
    • 2000
  • Seals in universal joint bearing are a important component reinforcing lubrication performance by holding a lubricant and preventing infiltration of dust, moisture, etc. There is a great difference in seal performance according to seal shape and bonding position. Therefore, in this study, as for the lib type seal and O-ring type seal, FEM analysis are conducted using Mooney-Rivlin Model. The results are indicate that O-ring having higher contact stress and larger contact area than lib type is more profitable.

  • PDF

A study on the flood runoff analysis with TANK MODEL (탱크 모델에 의한 홍수(洪水) 유출량(流出量) 해석(解析)에 관(關)한 연구(硏究))

  • Hong, Chang-sun;Choi, Han-kuy
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.95-101
    • /
    • 1983
  • This study aims at the determination of the coefficienties of runoff and infiltration affecting runoff. The rating curve is more available than the peak flood runoff to determine flood control plan of flood control reservoir and the volume of hydroelectric power plant, or to make multipurpose dam. In hydrologic analysis and design, it is necessary to develop relations between precipitation and runoff, possible using some of the factors affecting runoff as parameters. In order to calculate the runoff discharge, the runoff process constituting elements are divided to the surface runoff, the subsurface runoff and the groundwater runoff. By comparing the computed hydrograph with the measured hydrograph, determinned the watershed TANK Model constant Varying the tank model constant for approximating the computed hydrograph to the measured hydrograph.

  • PDF

Analysis for fire suppression efficiency of intermittent water spray pattern with FDS (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.200-203
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively low and the infiltration of water mist to the fire source is not effective. In addition to lower penetration force, the evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist system is expected to improve the penetration force of water mist as well as the dilution coverage capability with the stratified spray characteristics. At this paper we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis shall be supportive to the development of the prototype of water mist nozzle.

  • PDF