• 제목/요약/키워드: Infiltration Ratio

검색결과 227건 처리시간 0.029초

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

물수지분석 기법에 의한 논에서의 회귀율 조사분석 (Return flow analysis of paddy field by water balance method)

  • 정상옥;손성호
    • 한국농공학회지
    • /
    • 제43권2호
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF

가미해표이진탕이 알레르기 천식 백서의 호흡 양상과 기관조직에 미치는 영향 (The Effects of Kamihaepyoijin-tang on the Respiratory Patterns and Tracheal Tissues in Allergic Asthma)

  • 김민수;박동일
    • 동의생리병리학회지
    • /
    • 제16권3호
    • /
    • pp.557-562
    • /
    • 2002
  • The present study was made with the aim of finding out the Kamihaepyoijin-tang's effect on the allergic asthma using the Egg-White Implant(EWI) method model recommended by de Siqueira et al. Kamihaepyoijin-tang has widely been prescribed and used in Oriental Medicine for controlling and curing of cough, asthma, nasal obstruction. Previous studies have demonstrated that Kamihaepyoijin-tang had analgesic, anticonvulsive effects. But it is uncertain whether Kamihaepyoijin-tang could inhibit the allergic reaction of rats with experimentally induced allergic asthma using EWI method. With such aim. the respiratory patterns and eosinophil infiltration in the tracheal mucosa of the rats were mainly observed. The results were summerized as follows ; 1. The frequency of malformed respiratory patterns in Kamihaepyoijin-tang treated groups were decreased as compared with the control group. 2. The Ratio of malformed respiratory patterns in Kamihaepyoijin-tang treated groups were significantly decreased as compared with the control group(p<0.02). 3. The eosinophil infiltration in Kamihaepyoijin-tang treated groups were decreased as compared with the control group. 4. The eosinophil infiltration that inside of trachea tissue in Kamihaepyoijin-tang treated groups were significantly decreased as compared with the control group(p<0.05). Depending upon above results, it is considered that Kamihaepyoijin-tang has the inhibitory effects on the allergic asthma of rats and suggested that it could be used in relieving patients of the symptoms which are caused by allergic asthma.

춘천지역의 장려수도품종의 용수량 측정시험 (The Measuring Experiment of Irrigation Water for Spreading Varieties of Rice Plant in Chuncheon Area)

  • 고희완
    • 한국농공학회지
    • /
    • 제29권4호
    • /
    • pp.93-105
    • /
    • 1987
  • This Study was carried out at the experimental Plot of Kang-Weon Province, Institute of Agriculture experiment, to find out Irrigation Water requirement and suitable calculating formula of evapotranspiration on Spreading Varieties of rice plant such as Seul Oak, Bokkwang and Teaback in Chuncheon Area. The evapotranspiration, infiltration, and consumptive use of water were measured by Micro Lysimeter for four years from '86yr. Also, yield of rice was investigated during same period. With the Kc Value taken from experimental value, evapotranspiration was calculated by methods of Blaney & criddle, Penman, Hargreaves and Thornthwaite by Computer using meteorological data in Chuncheon Area for twenty one yrs from '66yr to '86yr. All analyses were conducted based on average value of experiment for four years and the results are summarized as follows : 1) The yield by varieties through this experiment showed 1.06 times in Seul Oak, 1.94 times in Bokkwang and 1.89 times in Teaback more than Standard Yield. 2) The consumptive use of water including infiltration were 1.068.4mm in Seul Oak, 1,102. 6mm in Bokkwang and 1,195.6mm in Teaback 3) The evapotranspiration by Actual measurement presented 520.lmm in Seul Oak, 540.lmm in Bokkwang and 598.4mm in Teaback 4)The ratio of evapotranspiration and infiltration over Panevaporation showed 1.2 to 1.4. 5) The irrigation water reguirement by water balance were shown to be irrigated more than 584 mm / yr in average during 21 years from '66yr to '86yr for all Varieties and those for loyr frequency 693 mm in Seul Oak, 712 mm in Bokkwang and 728 mm in Teaback respectively. 6) Crop Coefficient (Ke Value) of the tested rice plant during the period were shown as Table 10. 7) Penman Method was the formula the most close to experiment Value among four different methods of Blaney & Griddle Penman, Hargreaves, and Thornthwaite.

  • PDF

WEP 모형을 이용한 도림천 유역 물순환 모의 (Water Cycle Simulation for the Dorimcheon Catchment Using WEP Model)

  • 이승종;김영오;이상호;이길성
    • 한국수자원학회논문집
    • /
    • 제38권6호
    • /
    • pp.449-460
    • /
    • 2005
  • 본 연구에서는 전형적인 도시하천으로 왜곡된 물순환을 보이는 도림천 유역에 대해서 WEP(Water and Energy transfer Processes) 모형을 이용하여 물순환 모의를 수행하였다. 과거(l975년)와 현재(2000년)의 토지이용도를 이용한 모의를 통해 도시화에 의한 불투수율 증가가 유출특성에 미치는 영향을 분석하였으며, 모의결과 도시의 개발로 인해 과거보다 첨두 도달시간은 감소하고, 첨두 및 총유출량이 증가한 것으로 나타났으며, 침투량과 기저유출량이 감소한 것을 확인할 수 있었다. 또한 왜곡된 물순환을 회복하기 위한 대안으로 침투트랜치와 투수성 포장재의 설치 효과에 대한 모의를 수행하였으며, 모의결과 두 가지 대안을 함께 적용했을 경우에 도시개발 이전의 유출특성에 근접하는 것을 확인할 수 있었다.

외기 중 미세먼지의 공동주택 실내 유입에 관한 연구 (Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings)

  • 방종일;조성민;성민기
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

부자 추출물이 LPS로 유도된 C57BL6 마우스의 패혈증 연관 급성 폐 손상에 미치는 영향 (Effect of Water Extract of Aconiti Lateralis Preparata Radix on Lung Injury in LPS-induced Septic C57BL6 Mice)

  • 이인승;부민아;심재욱;백승호;박진봉
    • 대한융합한의학회지
    • /
    • 제4권1호
    • /
    • pp.19-27
    • /
    • 2022
  • Objectives: TSepsis and subsequent acute lung injury (ALI) is a critical state of health caused by infection or endotoxins. This study was conducted to evaluate the effect of Water Extract of Aconiti Lateralis Preparata Radix (AR) on lipopolysaccharide (LPS)-induced sepsis in C57BL/6 mice. Methods: Male C57BL/6 mice were intraperitoneally injected with LPS to induce sepsis and ALI. AR was orally fed twice at 30 min and 180 min after LPS injection. At 24 h post injection, mice were sacrificed, bronchoalveolar lavage fluid (BALF) and blood was collected, and lung tissue was harvested. Hematoxylin and eosin staining was performed in lung tissues, wet/dry ratio of the lung tissue was measured, and the serum cytokine and chemokine levels were analyzed. Results: AR revoked the LPS-induced pathological changes in lung tissues, such as abnormal histological structures, immune cell infiltration and lung edema. Also, AR suppressed the neutrophil infiltration into the lung which was greatly increased by LPS injection based on the cell content of collected BALF. Serum cytokines and chemokines were measured, and AR reversed the LPS-induced increase of cytokines such as interleukin 1 beta, interleukin 6, tumor necrosis factor alpha and chemokines including C-X-C motif chemokine ligand 1 and 2. Conclusion: TAR showed a protective effect in the pathological progress of LPS-induced ALI. Especially, AR suppressed lung edema and infiltration of neutrophils by inhibiting cytokine and chemokine expressions. Such results demonstrate the potential of AR as a therapeutic agent for sepsis and sepsis-induced ALI.

초기토양조건에 대한 분포형모형 유출민감도 분석 (Analysis of Runoff Sensitivity for Initial Soil Condition in Distributed Model)

  • 박진혁;허영택
    • 대한토목학회논문집
    • /
    • 제28권4B호
    • /
    • pp.375-381
    • /
    • 2008
  • 본 연구에서는 자체 개발한 물리적기반의 격자다층 분포형 홍수유출모형을 이용하여 남강댐유역을 대상으로 유출해석을 하고, 최적 매개변수 산정을 위하여 각 매개변수별 민감도 분석을 실시하였다. 그 중 유출량에 가장 큰 영향을 끼치는 유역의 초기 토양함수 상태 및 포화 투수계수를 중심으로 유출량에 미치는 영향의 정도를 파악하고자 하였다. 강우유출해석의 결과로부터 모형의 적합성을 평가하기 위하여 체적오차의 백분율(VER)과 첨두유량 오차의 백분율(QER)을 이용하여 모형을 평가하였으며, VER과 QER이 각각 16.7%, 6.7%로 나타나 매개변수 보정 전에 비해 약 6% 향상된 결과를 보였다. 매개변수 민감도 분석 결과, 개발된 분포형 모형에서 유출에 가장 큰 영향을 미치는 부분이 토양 조건 중에서 투수계수와 층 분할 비율이라는 것을 알 수 있었고, 분포형모형의 특성상 매개변수의 초기보정 없이도 유량의 크기와 첨두시간 모두 관측값과 비교적 잘 맞는 것을 확인할 수 있었다.

급기제트 조건에 따른 냉동용 전시케이스의 성능 (Performance of Refrigerated Display Cabinets in accordance with the Supply Air Jet Condition)

  • 성순경
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.80-86
    • /
    • 2011
  • Vertical open display cabinets are widely used in shopping mall, supermarkets, retail stores. Maintaining the temperature of foods in the display cabinet is vitally important to retailers to ensure optimal food quality and safety. The purpose of this study is to reduce the infiltration of air and heat loss from ambient space to display cabinet. The three-dimensional Computational Fluid Dynamics(CFD) simulation is used for the analysis of air flow patterns and temperature distribution in refrigerated display cabinets. Under several operating conditions which vary both the inner and outer jet velocities in the range from 0.3 to 1.1 m/s, simulations were carried out. This paper presents a performance of display cabinets with single jet and double jet. The energy consumption due to thermal entrainment ratio is plotted with varying Re. It was found that the double jet system is better than single jet system in terms of temperature distribution and energy saving.

집적암거에 의한 대류수개발에 관한 연구 (A study on the Development of Ground water by the Infiltration Gallery)

  • 한욱동
    • 한국농공학회지
    • /
    • 제15권3호
    • /
    • pp.3096-3106
    • /
    • 1973
  • As a link in the chain of antidrought measure, our attempt is made to obtain basic informations on the construction of an infiltration gallary which can be supplied with irrigation water by catching of underground water in small river beds, which is economical, permanent and efficient. The experiment was made, concerning the structure of catchment conduits, by constructing a model sand tank $1.5m{\times}5m{\times}1.5m$ in dimension made of reinforced concrete. Various kinds of measuring equipment were attached to the model tank which contains a set of catchment conduits, each of them was made 30cm in diameter and 60cm in length with the ratio of sectional area to total area of influx holes 10:1, 20:1, 30:1. The average size of influx holes was fixed from 0mm to 10mm, 20mm and 30mm in diameter respectively. Obtained results are as follow; (a) In view of the water catchment capacity, manufacturing cost and the antipressure strength of the catchment conduits, it is the best method to decide the total number of influx holes 20 per sq. meter of each tile surface, and the size of influx holes 20mm in diameter, when the conduits have diameter less than 1m. (b) The greatest factor of safety against external load is to arrange the influx holes in a zigzag manner on the tile surface. The most effective formula of arrangement is $S{\geqq}\sqrt{2gd}$ where: s : spacing of opening row. g : spacing of opening line. d : diameter of influs hole.

  • PDF