• Title/Summary/Keyword: Infiltration Area Analysis

Search Result 159, Processing Time 0.032 seconds

Analysis of Infiltration Area using Prediction Model of Infiltration Risk based on Geospatial Information (지형공간정보 기반의 침투위험도 예측 모델을 이용한 최적침투지역 분석)

  • Shin, Nae-Ho;Oh, Myoung-Ho;Choe, Ho-Rim;Chung, Dong-Yoon;Lee, Yong-Woong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.199-205
    • /
    • 2009
  • A simple and effective analysis method is presented for predicting the best infiltration area. Based on geospatial information, numerical estimation barometer for degree of infiltration risk has been derived. The dominant geospatial features influencing infiltration risk have been found to be area altitude, degree of surface gradient, relative direction of surface gradient to the surveillance line, degree of surface gradient repetition, regional forest information. Each feature has been numerically expressed corresponding to the degree of infiltration risk of that area. Four different detection probability maps of infiltration risk for the surveillance area are drawn on the actual map with respect to the numerically expressed five dominant factors of infiltration risks. By combining the four detection probability maps, the complete picture of thr best infiltration area has been drawn. By using the map and the analytic method the effectiveness of surveillance operation can be improved.

Factor analysis on infiltration using correlations (상관성 분석을 통한 침입수 발생 영향인자 분석)

  • Ryu, Jae-Na;Oh, Je-Ill;Choi, Ick-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.185-192
    • /
    • 2011
  • Pearson's correlation was used to determine relations between infiltration and affecting factors using flow monitoring data measured in 24 areas with different characteristics. Factors showed relatively high correlations than others were indexed to determine infiltration rates of the study area. Among 8 factors(service area, sewer length, sewer diameter, multiplier of sewer length and diameter, number of manholes, population, number of properties, number of households) tested, the multiplier of sewer length and diameter, the number of population and the number of household in each service area indicated higher correlation coefficient(>0.8) than others. The goodness of fitness of linear regressions between infiltration and the factors followed the order: sewer length and diameter(0.68)> population(0.65)> number of household(0.60). Infiltration rates calculated by the multiplier of sewer length and diameter, the number of population and the number of household in each service area were 0.046~1.0396 $m^{3}/d{\cdot}mm-km$, 0.0917~1.7355 $m^{3}/capita{\cdot}d$, 0.196~4.529 $m^{3}/household {\cdot}d$ respectively. After sewerage rehabilitation work of the area, the infiltration rates calculated by above factors with high correlations are expected to be used for comparing effectiveness of the work once they are estimated under the same flow measuring conditions.

Development and Effects Analysis of The Decentralized Rainwater Management System by Field Application

  • Han, Young Hae;Lee, Tae Goo
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.15-21
    • /
    • 2014
  • In this study, we developed a modular rainwater infiltration system that can be applied for general purposes in urban areas to prepare for localized heavy rain caused by climatic change. This study also analyzed the system's effects on reducing runoff. An analysis of the system's effects on reducing runoff based on rainfall data and monitoring data obtained between September 2012 and December 2013 after the system was installed showed that approximately 20~22% of the runoff overflowed from the infiltration facility. Also, an analysis of the runoff that occurred during the monsoon season showed that 25% of the runoff overflowed through the storm sewer system of the urban area. These results show that the rainwater overflows after infiltrating the detention facility installed in the area during high-intensity rainfall of 100mm or higher or when precipitation is 100mm for 3~4 days without the prior rainfall. According to precipitation forecasts, torrential rainfall is becoming increasingly prevalent in Korea which is increasing the risk of floods. Therefore, the standards for storm sewer systems should be raised when planning and redeveloping urban areas, and not only should centralized facilities including sewer systems and rainwater pump facilities be increased, but a comprehensive plan should also be established for the water cycle of urban areas. This study indicates that decentralized rainwater management can be effective in an urban area and also indicates that the extended application of rainwater infiltration systems can offer eco-friendly urban development.

Sensitivity analysis of effective imperviousness estimation for small urban watersheds (도시 소유역 유효불투수율의 민감도 분석)

  • Kim, Dae Geun;Ko, Young Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.181-187
    • /
    • 2009
  • In this study, a runoff hydrograph and runoff volume were calculated by using the kinetic wave theory for small urban watersheds based on the concept of low impact development(LID), and the effective imperviousness was estimated based on these calculations. The degree of sensitivity of the effective imperviousness of small watersheds to the impervious to pervious area ratio, infiltration capability, watershed slope, roughness coefficient and surface storage depth was then analyzed. From this analysis, the following conclusions were obtained: The effective imperviousness and paved area reduction factor decreased as the infiltration capability of pervious area increased. As the slope of watersheds becomes sharper, the effective imperviousness and the paved area reduction factor display an increasing trend. As the roughness coefficient of impervious areas increases, the effective imperviousness and the paved area reduction factor tend to increase. As the storage depth increases, the effective imperviousness and the paved area reduction factor show an upward trend, but the increase is minimal. Under the conditions of this study, it was found that the effective imperviousness is most sensitive to watershed slope, followed by infiltration capability and roughness coefficient, which affect the sensitivity of the effective imperviousness at a similar level, and the storage depth was found to have little influence on the effective imperviousness.

Analysis on the Effect of Infiltration Collector Well Installation on the Water Control (침투통의 설치에 따른 치수효과 분석)

  • Shim, Jae-hyun;Lee, Cheol-kyu;Lee, Jong-kook;Kim, Jin-young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.298-302
    • /
    • 2004
  • In this study, the runoff reduction effect was analyzed quantitatively focusing on the infiltration collector well located in the test area. On the basis of the analysis of the data obtained by examining the real-time measurement field data, the runoff reduction was examined through the measured rainfall of the year 2003 by applying the analysis result, with the PCSWMM model to the Kiheung-Gugal residential area, which is selected as the test basin. According to the analysis, it is revealed that an infiltration collector well can reduce up to $65\~98\%$ of runoffs, compared to a conventional one. For measured rainfalls, an infiltration collector well was able to reduce up to $15\~23\%$ of runoffs and $3\~25\%$ of peak runoffs. These results show that the effects of infiltration collector wells might vary with rainfall intensity and its duration. However, the infiltration collector well was confirmed as the one of the alternatives of runoff reduction facilities in urbanized catchment.

  • PDF

A Case Study on Development of Stormwater Retention and Infiltration Pond System (우수저류 및 침투연못 시스템개발 사례연구 - 우수 저류 및 침투 효과를 중심으로 -)

  • Lee, Jae Chul;Yoon, Yeo Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.52-61
    • /
    • 2003
  • This study was carried out to analyze the effects of stormwater retention and infiltration pond on reduction of flood peak and volume in a experimentally developed ecological pond. The experimental site has 542$m^2$ watershed area, 1,310mm yearly-averaged rainfall. And the area of the retention pond is 60$m^2$, the maximum water depth is 0.5m, the maximum and average storage is 15$m^3$and 9.3$m^3$d. And the area of infiltration pond is 58$m^2$, and the water depth varies 0.2m~0.5m. The monitoring system consists of one rainfall gage, one Parshall flume and acoustic water level gage, two rectangular weirs and acoustic water level gage for discharge gaging, and one data recording unit. Data from ten storm events in total, three storm events in year 2000 and seven storm events in year 2001, were collected. From the data the evaporation rate was achieved with the water balance equation, and the result shows 5.0mm/day in average. The result from the analysis of the effects on reduction of flood peak and volume, is that 14% reduction of flood volume and 15% reduction of flood peak in retention pond and 49% reduction of flood volume in infiltration pond.

An Application of Infiltration Facilities for Reducing the Runoff in the Basin (유출저감을 위한 유역내 침투시설의 적용)

  • Lee, Jae-Joon;Seol, Ji-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.133-141
    • /
    • 2011
  • Urban development of basin causes increasing runoff volume and peak flowrate and shortening in time of concentration, which may cause frequent flooding downstream. An infiltration facilities are operated as a method of reducing flood discharge of urban rivers and peak flowrate. There are various types of infiltration facilities like infiltration trench and porous pavement. In this study, runoff reduction effect due to installation of infiltration facilities are performed and focused on $0.18km^2$ residential area of Ok-kye dong and $0.67km^2$ industrial area of Gong-dan dong in Gumi City. The analysis is fulfilled with comparison of total runoff volume and runoff reduction volume by using the WinSLAMM and the relation equation between area ratio of infiltration facilities and ratio of runoff reduction are derived and peak flow reduction effect for installation of infiltration facilities is analyzed.

Instability Analysis of Road Landfill Slope during Heavy Rainfall (호우시 도로성토사면의 사면불안정 분석)

  • Kim, Young-Muk;Park, Hyang-Keun;Chol, Mun-Hee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.3
    • /
    • pp.41-50
    • /
    • 2004
  • The study of seepage behavior is very important to slope stability of road landfill for heavy rainfall season. This study is done to propose more stable of road landfill based on analysis of seepage behavior and slope stability for some cases of road landfill. The selected sections of collapsed road landfill are most general case of road landfill, a case is landfill on the ground area and another case is on the slope area. The results of this study is summarized as follows. It is founded that the road landfill on the ground area is increased saturation region due to rainfall infiltration, and the seepage behavior of road landfill is solved by theory of unsaturated flow. The road landfill is more unstable due to rainfall infiltration at the slope surface, especially during heavy rainfall. The case of road landfill on the slope area is analyzed in consideration of slope surface infiltration, and it is founded that the slope instability is increased because of rainfall infiltration. The drain layer located on the original ground which made by more permeable materials could be good action of slope stability in the case of road landfill on the slope area.

  • PDF

Characterization of Infiltration Analyses Using Long-Term Monitoring Flow Data (장기 모니터링 자료를 활용한 침입수 산정 방법론별 특성 분석)

  • Lee, Jaehyun;Kim, Insop;Oh, Jeill;Park, Chulhwi
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.411-418
    • /
    • 2009
  • The analysis of characteristics of water use evaluation and nighttime domestic flow evaluation was performed by using result from flow monitoring and surveying water supply records and nighttime domestic flow for a year. The analysis of correlations showed that, for both sites, the infiltration ratio and wastewater flow have shown a good relationship with high correlation factor and that the calculation of wastewater flow was highly affected by monthly rainfall depth as well as number of rain days. From this result, it was concluded that the measurement of infiltration should be performed when the rainfall does not significantly affect the sewer flow. Also, it is notable that each value of calculated using method for infiltration evaluation are not comparable to each other, but independent methods. In selecting of evaluation method for infiltration, therefore, a great emphasis should be imposed to the character of area and the seasonal factor in order to select optimal one. It is desirable way for evaluating infiltration and reduction ratio using result from an optimal method.

The finite element analysis on structural stability of road with infiltration trench (침투도랑 설치에 따른 도로 구조 안정성의 유한요소 해석)

  • Jung, Jong-Suk;Hyun, Kyoung-Hak;Kim, In-Tae;Song, Jin-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.107-122
    • /
    • 2015
  • The purpose of this study is to analyze the structural stability of pavement due to water infiltration at the road with infiltration trench as using the FEM(finite element analysis). Five cases for FEM is divided considering the amount of rainfall and rain duration time. The results of FEM show that the more rainfall in a short period time is faster the change of moisture content. Also, it is the proportional relationship between and changing area of moisture content of more than 40% due to rainfall. Case 3 and 4 are necessary to check the installation of infiltration trench because of moisture content of more than 40%, recovery time of initial moisture content, and changing area of more than 40%. Case 1,2, and 5 have no a significant effect on road pavement structure due to lower moisture content and shorter duration time of higher moisture content.