• Title/Summary/Keyword: Infill

Search Result 324, Processing Time 0.021 seconds

The 26 september 2019 Istanbul Earthquake, its characteristics and reminders

  • Gullu, Ahmet;Yuksel, Ercan
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.75-85
    • /
    • 2022
  • The megacity Istanbul was struck by an earthquake on September 26, 2019, with a moment magnitude (Mw) of 5.8. The mainshock was followed by many aftershocks. Although the peak ground acceleration (PGA) of the mainshock was as low as 0.08 g, its effect has been more than expected. The intensive reconnaissance studies were accomplished in the highly populated Zeytinburnu and Pendik districts of Istanbul. While the earthquake (EQ) was relatively smaller concerning record-specific intensity measures; the damages such as concrete spalling in reinforced concrete (RC) members, detachment and diagonal cracking of infill walls in RC frames as well as cracks in masonry structures were reported from non-engineered and some engineered buildings. Many studies in the literature state that record-specific intensity measures are not sufficient to evaluate the seismic performance of the structures. The structure-specific intensity measures, soil characteristics, as well as significant duration, energy, and frequency content of EQs should be considered for the evaluation. Dependently, the frequency and energy contents of the Istanbul Earthquake are evaluated to discuss the possible reasons for the perceived effects and the damages. It is concluded that the EQ caused resonance effects on a variety of structures because of its complex frequency content as well as rather low building quality.

Seismic resonance vulnerability assessment on shear walls and framed structures with different typologies: The case of Guadalajara, Mexico

  • Ramirez-Gaytan, Alejandro;Preciado, Adolfo;Flores-Estrella, Hortencia;Santos, Juan Carlos;Alcantara, Leonardo
    • Earthquakes and Structures
    • /
    • v.22 no.3
    • /
    • pp.263-275
    • /
    • 2022
  • Structural collapses can occur as a result of a dynamic amplification of either, the building's seismic response or the ground shaking by local site effects; one of the reasons is a resonance effect due to the proximity of the structural elastic fundamental period TE and the soil fundamental period TS. We evaluate the vulnerability to resonance effects in Guadalajara, México, in a three-step schema: 1) we define structural systems in the building environment of western Guadalajara, in terms of their construction materials and structural components; 2) we estimate TE with different equations, to obtain a representative value in elastic conditions for each structural system; and, 3) we evaluate the resonance vulnerability by the analysis of the ratio between TE and TS. We observe that the larger the soil fundamental period, the higher the resonance vulnerability for buildings with height between 17 and 39 m. For the sites with a low TS, the most vulnerable buildings will be those with a height between 2 and 9 m. These results can be a helpful tool for disaster prevention, by avoiding the construction of buildings with certain heights and structural characteristics that would result in a dangerous proximity between TE and TS.

Evaluation of cyclic behavior of lateral load resisting system with eccentric brace and steel plate

  • Reza Khalili Sarbangoli;Ahmad Maleki;Ramin K. Badri
    • Structural Engineering and Mechanics
    • /
    • v.89 no.3
    • /
    • pp.239-252
    • /
    • 2024
  • Steel plate shear walls (SPSWs) are classified as lateral load-resisting systems. The feasibility of openings in the steel plate is a characteristic of SPSWs. The use of openings in SPSWs can lower the load capacity, stiffness, and energy dissipation. This study proposes a novel form of SPSWs that provides convenient access through openings by combining steel plates and eccentrically braced frames (EBFs). The proposed system also avoids a substantial reduction in the strength and stiffness. Hence, various geometric forms were analyzed through two different structural approaches. Groups 1, 2, and 3 included a steel EBF with a steel plate between the column and EBF in order to improve system performance. In Group 4, the proposed system was evaluated within an SPSW with openings and an EBF on the opening edge. To evaluate the performance of the proposed systems, the nonlinear finite element method (NL-FEM) was employed under cyclic loading. The hysteresis (load-drift) curve, stress contour, stiffness, and damping were evaluated as the structural outputs. The numerical models indicated that local buckling within the middle plate-EBF connection prevented a diagonal tension field. Moreover, in group 4, the EBF and stiffeners on the opening edge enhanced the structural response by approximately 7.5% in comparison with the base SPSW system.

Evolution of pullout behavior of geocell embedded in sandy soil

  • Yang Zhao;Zheng Lu;Jie Liu;Jingbo Zhang;Chuxuan Tang;Hailin Yao
    • Geomechanics and Engineering
    • /
    • v.38 no.3
    • /
    • pp.275-284
    • /
    • 2024
  • This paper aims to explore the evolution of the pullout behavior of geocell reinforcement insights from three-dimensional numerical studies. Initially, a developed model was validated with the model test results. The horizontal displacement of geocells and infill sand and the passive resistance transmission in the geocell layer were analyzed deeply to explore the evolution of geocell pullout behavior. The results reveal that the pullout behavior of geocell reinforcement is the pattern of progressive deformation. The geocell pockets are gradually mobilized to resist the pullout force. The vertical walls provide passive pressure, which is the main contributor to the pullout force. Hence, even if the frontal displacement (FD) is up to 90m mm, only half of the pockets are mobilized. Furthermore, the parametric studies, orthogonal analysis, and the building of the predicted model were also carried out to quantitative the geocell pullout behavior. The weights of influencing factors were ranked. Ones can calculate the pullout force accurately by inputting the aspect ratio, geocell modulus, embedded length, frontal displacement, and normal stress.

Push-out tests and bond strength of rectangular CFST columns

  • Qu, Xiushu;Chen, Zhihua;Nethercot, David A.;Gardner, Leroy;Theofanous, Marios
    • Steel and Composite Structures
    • /
    • v.19 no.1
    • /
    • pp.21-41
    • /
    • 2015
  • Push-out tests have been conducted on 18 rectangular concrete-filled steel tubular (CFST) columns with the aim of studying the bond behaviour between the steel tube and the concrete infill. The obtained load-slip response and the distribution of the interface bond stress along the member length and around the cross-section for various load levels, as derived from measured axial strain gradients in the steel tube, are reported. Concrete compressive strength, interface length, cross-sectional dimensions and different interface conditions were varied to assess their effect on the ultimate bond stress. The test results indicate that lubricating the steel-concrete interface always had a significant adverse effect on the interface bond strength. Among the other variables considered, concrete compressive strength and cross-section size were found to have a pronounced effect on the bond strength of non-lubricated specimens for the range of cross-section geometries considered, which is not reflected in the European structural design code for composite structures, EN 1994-1-1 (2004). Finally, based on nonlinear regression of the test data generated in the present study, supplemented by additional data obtained from the literature, an empirical equation has been proposed for predicting the average ultimate bond strength for SHS and RHS filled with normal strength concrete.

Improving the Performance of a Custom-built Apartment Efficiently (맞춤형 아파트의 효율적인 사업 수행에 관한 연구)

  • Han Song-Yi;Choi Jae-Kyu;Kim Kyung-Sook;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.96-105
    • /
    • 2003
  • Technical improvement and the growth of the Internet environment make the market segmental of the manufacturing industry. These social trends have had an effect on the housing market, and the housing market changed from the supplier-oriented to the consumer-oriented. In recent years the occupants' needs for the apartment is diversified and complicated. But the existing mass housing supply method has many problems. It couldn't satisfy the dwellers' various needs and couldn't reflect overall expected life span either. In order to realize the sustainable building & environment, the research for the open housing system is actively performed. Finally the custom-built apartment which imported the concept of the open housing is constructed. But after running the custom-built apartment, several problems are revealed. Therefore the purpose of this study is to analyze the problems and then suggest the improving methods for a custom-built apartment.

Shear Strength of Nailed Connection of Domestic Plywood as a Substitute for OSB (OSB 대체용 국내산 합판의 못 접합부 전단내력 성능)

  • Suh, Jin-Suk;Hwang, Sung-Wook;Hwang, Kweon-Hwan;Jeong, Gi-Young;Joung, Ha-Hyun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • This study was carried out in order to compare nail shear strength between domestic plywood and imported OSB for structural sheathing members as infill wall of wooden construction. The differences of nail shear strength between parallel-to-grain direction and perpendicular-to-grain direction of sheathing material to frame material were distinct at the plywood composition. The shear strengths of plywood and OSB with nail met current design values. The plywood of P-4 type, which uses MLH at surface layer and constructs 7 ply, showed greater than OSB regardless of grain direction of sheathing material to frame material. When the plywood as sheathing material to frame material was used, it was found out that the overall construction of perpendicular-to-grain direction of plywood had greater nail shear strengths than the construction of parallel-to-grain.

A Study of the Bezel Settings of a JinjuseonUsed for Joseon Royal Weddings Based on an Examination of the Washers (제조선시대 궁중혼례용 '진주선(眞珠扇)'의 받침못을 통해 본 감장(嵌裝) 기법 고찰)

  • Sim, Myung Bo;Kim, Sun Young
    • Conservation Science in Museum
    • /
    • v.21
    • /
    • pp.17-28
    • /
    • 2019
  • The term jinjuseon(眞珠扇), meaning literally a pearl fan, refers to a fan decorated with precious stones for use in royal wedding ceremonies. This study examined a jinjuseon housed in the National Palace Museum of Korea (NPMK) which currently lacks jeweled ornaments. In order to determine whether pearls or other gemstone settings originally ornamented the fan,the surface and composition of the gray materials remaining on the washers were investigated and the fan was compared with other artifacts decorated using similar techniques. The analysis revealed that the gray materials visible around the round rims of the washers contain tin-lead alloys. The traces of folded nails suggest that soldering was not applied. The remains of the infill observed in other artifacts with bezel settings indicate that this jinjuseon in the NPMK collection was produced using abezel setting technique wherein pearls or other gemstones were affixed by filling cylindrical bezels with tin-lead alloys.

Mid-length lateral deflection of cyclically-loaded braces

  • Sheehan, Therese;Chan, Tak-Ming;Lam, Dennis
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1569-1582
    • /
    • 2015
  • This study explores the lateral deflections of diagonal braces in concentrically-braced earthquake-resisting frames. The performance of this widely-used system is often compromised by the flexural buckling of slender braces in compression. In addition to reducing the compressive resistance, buckling may also cause these members to undergo sizeable lateral deflections which could damage surrounding structural components. Different approaches have been used in the past to predict the mid-length lateral deflections of cyclically loaded steel braces based on their theoretical deformed geometry or by using experimental data. Expressions have been proposed relating the mid-length lateral deflection to the axial displacement ductility of the member. Recent experiments were conducted on hollow and concrete-filled circular hollow section (CHS) braces of different lengths under cyclic loading. Very slender, concrete-filled tubular braces exhibited a highly ductile response, undergoing large axial displacements prior to failure. The presence of concrete infill did not influence the magnitude of lateral deflection in relation to the axial displacement, but did increase the number of cycles endured and the maximum axial displacement achieved. The corresponding lateral deflections exceeded the deflections observed in the majority of the previous experiments that were considered. Consequently, predictive expressions from previous research did not accurately predict the mid-height lateral deflections of these CHS members. Mid-length lateral deflections were found to be influenced by the member non-dimensional slenderness (${\bar{\lambda}}$) and hence a new expression was proposed for the lateral deflection in terms of member slenderness and axial displacement ductility.

Health Risk Assessment for Artificial Turf Playgrounds in School Athletic Facilities: Multi-route Exposure Estimation for Use Patterns

  • Kim, Ho-Hyun;Lim, Young-Wook;Kim, Sun-Duk;Yeo, In-Young;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.206-221
    • /
    • 2012
  • Hazardous chemicals can be released from artificial turf used in some school playgrounds. To distinguish between Health risk assessment (HRA) exposure scenarios for this study, the ratio of elementary, middle and high schools was considered before final selection. Considering exposure pathways (inhalational, oral and dermal), media and materials were examined, targeting hazardous chemicals released from artificial turf playground-related products. Upon evaluation, the quantity of infill chips was shown to exceed the domestic product content standard (90 mg/kg) at eight (16%) out of 50 schools. PAHs were shown to exceed standards (10 mg/kg) at two (4%) out of the 50 schools. The excess cancer risk (ECR) of carcinogens was shown to be $1{\times}10^{-6}$ in most users for the worst exposure scenario. In children with pica, who represented the most extreme exposure group, the ECR was expected to be as high as $1{\times}10^{-4}$, showing the low risk level of carcinogens. The hazard index (HI) for individual chemicals was shown to be low, at around 0.1 or less, except for children with pica, according to the mean exposure scenario of artificial turf playground exposure. However, the HI was shown to exceed 1.0 in children with pica. Therefore, no direct health risk was found in using artificial turf playgrounds and urethane flooring tracks for the mean exposure scenario, except in children with pica.