• Title/Summary/Keyword: Inferior border

Search Result 145, Processing Time 0.018 seconds

Activation of Vestibular Neurons Projecting to Autonomic Brain Stem Nuclei Following Acute Hypotension in Rats

  • Choi, Myoung-Ae;Wang, Won-Ki;Choi, Dong-Ok;Kim, Min-Sun;Park, Byung-Rim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.3
    • /
    • pp.133-140
    • /
    • 2004
  • The purpose of the present study was to elucidate the possible involvement of the medial vestibular nucleus (MVN) and inferior vestibular nucleus (IVN) following acute hypotension in the vestibuloautonomic reflex through vestibulosolitary or vestibuloventrolateral projections. Acute hypotension-induced cFos expression was assessed in combination with retrograde cholera toxin B subunit (CTb) tract tracing. After injection of CTb into the solitary region, CTb-labeled neurons were located prominently around the lateral borders of the caudal MVN and medial border of the IVN. The superior vestibular nucleus also had a scattered distribution of CTb-labeled neurons. After injection of CTb toxin into the unilateral VLM, the distributions of CTb-labeled neurons in the MVN and IVN were similar to that observed after injection into the solitary region, although there were fewer CTb-labeled neurons. In the caudal MVN, about 38% and 13% of CTb-labeled neurons were double-labeled for cFos after injection of CTb into the solitary region and the VLM, respectively. In the IVN, 14% and 7% of CTb-labeled neurons were double-labeled for cFos after injection of CTb into the solitary region and the VLM, respectively. Therefore, the present study suggests that acute arterial hypotension may result in activation of vestibulosolitary pathways that mediate behavioral and visceral reflexes, and vestibuloventrolateral medullary pathways that indirectly mediate vestibulosympathetic responses.

STABILITY OF SIMULTANEOUS MAXILLARY AND MANDIBULAR SURGERY;[Ⅰ]Wire osteosynthesis (상하악 동시 악교정술시 안정성에 관한 연구;[Ⅰ] 강선 고정에 의한 방법)

  • Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.9-20
    • /
    • 1990
  • A series of 19 cases with maxillary hyperplasia and mandibular retrognathia were operated on by simultaneous superior repositioning of the maxilla after Le Fort I osteotomy and anterior repositioning of the mandible after bilateral sagittal split ramus osteotomies with or without osteotomy of the inferior border of the mandible. These were evaluated by retrospective cephalometric and computer analysis for the longitudinal skeletal and dental changes for an average of 17.1 months after surgery. For stabilization of the osteotomized segments, the authors used wire osteosynthesis by means of bilateral infraorbital and zygomatic buttress suspension wire at the maxilla, and direct interosseous wire at the split segments of the mandibular rami. Results show generally good stability after simultaneous maxillary and mandibular surgery with wire osteosynthesis, and a minimal to moderate tendency toward skeletal and dental relapse. This article is a preliminary study to defy the efficiency of the wire osteosynthesis (wo)compared with rigid internal fixation (RIF) for simultaneous maxillary and mandibular surgery. 1. The vertical relapse rate of the A point after superior repositioning of the maxilla is 2.2%. 2. The horizontal relapse rate of the B point after advancement of the mandible is 18.3%. 3. The condyle is distracted inferiorly and slightly posteriorly at the immediate postoperative period. 4. At the long term follow up examination, the condyle presents tendency of return to the preoperative position. 5. Condylar segment angle is decreased at the immediate postoperative period, and at the long term follow up evaluation, the angle is increased. 6. Gonial angle is increased at the immediate postoperative period, and then is decreased at the long term follow up evaluation. 7. The dentition is satisfactory with acceptable movement at the long term follow up evaluation. 8. At the mandibular free body analysis, genioplasty shows good stability. 9. Wire osteosynthesis provides excellent stabilization for the simultaneous maxillary and mandibular surgery.

  • PDF

THE EFFECT OF BIOACTIVE GLASS AND A RESORBABLE MEMBRANE ON B ONE REGENERATION OF THE MANDIBULAR BONE DEFECTS IN RABBIT (골결손부에서 Bioactive glass와 차폐막의 골재생 효과)

  • Ryu, Sun-Youl;Park, Se-Chan;Yun, Cheon-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.613-619
    • /
    • 2000
  • The purpose of the present study was to investigate the effect of Bioactive glass on bone regeneration in the experimental mandibular bone defects. Five rabbits, weighing about 2.0kg, were used. Three artificial bone defects, $5{\times}5{\times}5mm$ in size, were made at the inferior border of the mandible. In the experimental group 1, the bone defect was grafted with $Biogran^{(R)}$ and covered with $Bio-Gide^{(R)}$ resorbable membrane. In the experimental group 2, $Biogran^{(R)}$ was grafted only. In the control group, the bone defect was filled with blood clot and was spontaneously healed. The animals were sacrificed at 1, 2, 4, and 8 weeks after the graft. Microscopic examination was performed. Results obtained were as follows: In the control group, the osteoid tissue was observed at week 1 and the bone trabeculi were connected each other and matured at week 2. The lamellar bone formation appeared at week 4, and the amount of bone tissue was increased at week 8. In the experimental group 1, the fibrous tissue was filled between the granules of Bioactive glass and the cartilage formation was found adjacent to the normal bone at week 1. The bone tissue was formed between the granules at week 2, while the amount of bone tissue increased and the lamellar bone formation was observed at week 4. The lamellar bone was increased at week 8. Histologic findings were Similar between the experimental groups 1 and 2, although the amount of Bioactive glass granules lost was increased in the latter. These results suggest that new bone formation is found around the Bioactive glass granules grafted into the bone defects, and the membrane plays a role in keeping the granules and preventing the fibrous tissue invasion.

  • PDF

A ROENTGENOGRAPHIC STUDY OF NORMAL SUBMANDIBULAR GLANDS USING ISOBARIC SIALOGRAPHY (등압수액선조영술을 이용한 정상성인의 악하선에 관한 방사선학적 연구)

  • O Gyu Myeong;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.13 no.1
    • /
    • pp.127-137
    • /
    • 1983
  • The aim of this study was to establish the diagnostic criteria of normal submandibular glands in adults. Materials included 132 sialograms of selected person from 23 to 28 years of age. In subjects each variable was measured and evaluated statistically introducing 18 items respectively. Conclusions from this study were as follows. 1. The mean diameter of main duct was 1.96㎜ in distal end and 2.71㎜ in hilar end, so the diameter of distal end was smaller than that of hilar end in submandibular glands. 2. The mean length of main duct was 42.02㎜ in submandibular glands. 3. The mean angle of main duct was 35.67 degrees with inferior border of mandible and 103.05 degrees at posterior mylohyoid portion. 4. In configurations following shape of main duct, those revealed that 39.39% of cases of the curvilinear type, 16.67% of cases of the linear type, 22.73% of cases of the sigmiod type and 21.21% of cases of the angular type. And in configurations following course of main duct, those revealed that 83.33% of cases of the smooth type and 16.67% of cases of the tortuous type. 5. The mean caliber of submandibular glands was 45.59㎜ in superoinferior height, 43.56㎜ in anteroposterior width, 28.85㎜ in mediolateral width and 33.65㎜ in extent below mandibular angle. 6. Well-delineated acinar parenchyme was observed in 77.28% of cases and well-defined tertiary ducts in 50.06% of cases. 7. There were no differences between right and left submandibular glands in size and shape of main duct and parenchymal portion, but there were great variations in each individual.

  • PDF

A Study on the Convergence Technique enhanced GrabCut Algorithm Using Color Histogram and modified Sharpening filter (칼라 히스토그램과 변형된 샤프닝 필터를 이용한 개선된 그랩컷 알고리즘에 관한 융합 기술 연구)

  • Park, Jong-Hun;Lee, Gang-Seong;Lee, Sang-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.1-8
    • /
    • 2015
  • In this paper, we proposed image enhancement method using sharpening filter for improving the accuracy of object detection using the existing Grabcut algorithm. GrabCut algorithm is the excellent performance extracting an object within a rectangular window range, but it has the drawback of the inferior performance in image with no clear distinction between background and objects. So, in this paper, reinforcing the brightness and clarity through histogram equalization, and tightening the border of the object using the sharpening filter look better than that extracted result of existing GrabCut algorithm in a similar image of the object and the background. Based on improved Grabcut algorithm, it is possible to obtain an improved result in the image processing convergence technique of character recognition, real-time object tracking and so on.

Sex-related and racial variations in orbital floor anatomy

  • Moon, Seung Jin;Lee, Won Jai;Roh, Tai Suk;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.4
    • /
    • pp.219-224
    • /
    • 2020
  • Background: Repair of the orbital floor following trauma or tumor removal remains a challenge because of its complex three-dimensional shape. The purpose of the present study is to understand normal orbital floor anatomy by investigating its differences across four groups (Caucasian American and East Asian, males and females) via facial bone computed tomography (CT). Methods: A total of 48 orbits in 24 patients between 20 and 60 years of age were evaluated. Although most patients underwent CT scanning following trauma, the orbital walls were intact in all patients. Linear and angular measurements of the orbital floor were obtained from CT images. Results: Orbital floor width, length, angle between the orbital floor and medial wall, and distance from the inferior orbital rim to the lowest point of the orbital floor did not show a statistically significant difference between groups. Angles made by the infraorbital rim, the lowest point of the floor, and the anterior border of the infraorbital fissure were statistically significantly wider in East Asian females than in male groups. The floor depth in East Asian females was significantly smaller compared to all the other groups. Conclusion: East Asian female population had smaller curvature and depth of an orbital floor than the other groups, which means racial and sex-related differences should be considered in the orbital floor reconstruction.

STUDY ON THE ANATOMICAL POSITION OF MANDIBULAR CANAL USING COMPUTED TOMOGRAPHY IN MANDIBULAR PROGNATHISM PATIENTS (하악 전돌증 환자에서 전산화 단층 촬영을 이용한 하악관의 해부학적 위치에 관한 연구)

  • Lee, Dong-Hyun;Kim, Jae-Won;Lee, Su-Youn;Kim, Jae-Hyun;An, Sang-Heon;Lee, Sang-Han;Jang, Hyun-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.510-518
    • /
    • 2009
  • Purpose: In this study, we analyzed and compared the anatomical position of the mandibular canal in normal occlusion and mandibular prognathism patients. Patients and Methods: Computed tomography image from 58 patients were divided into normal occlusion group and mandibular prognathism group, and each measurement were taken in the each measuring points(2nd premolar, 1st molar, 2nd molar, 3rd molar, ramus). Measurements were statistically analyzed by student's t-test. Results: BC (Thickness of the buccal cortex) value was 2.3~2.7 mm, CB (Distance from the canal to the lingual aspect of the buccal cortex) value was 1.3~4.3 mm, MC (Diameter of the canal) value was 3.2~3.8 mm, LI (Distance from the canal to the lingual aspect of the lingual cortex) value was 2.0~3.7 mm, TM (Thickness of the total mandible) value was 9.5~12.9 mm and CM (Distance from the canal to the inferior border of the mandible) value was 6.9~17.5 mm. Conclusion: In the comparison between two groups, there was statistically significant difference in CB value of 2nd, 3rd molar between normal occlusion and mandibular prognathism, and other value in the rest of the measuring points didn't show statistically significant difference.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean

  • Jeon, Yong Hyun;Lee, Chul Kwon;Kim, Hee-Jung;Chung, Jae-Heon;Kim, Heung-Joong;Yu, Sun-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.470-475
    • /
    • 2017
  • PURPOSE. The purpose of this study was to identify the complex course of the mandibular canal using 3D reconstruction of microCT images and to provide the diagram for clinicians to help them understand at the interforaminal region in Korean. MATERIALS AND METHODS. Twenty-six hemimandibles obtained from cadavers were examined using microCT, and the images were reconstructed. At both the midpoint of mental foramen and the tip of anterior loop, the bucco-lingual position, the height from the mandibular inferior border, the horizontal distance between two points, and position relative to tooth site on the mandibular canal were measured. The angle that the mental canal diverges from the mandibular canal was measured in posterior-superior and lateral-superior direction. RESULTS. The buccal distance from the mandibular canal was significantly much shorter than lingual distance at both the mental foramen and the tip of anterior loop. The mandibular canal at the tip of anterior loop was significantly located closer to buccal side and higher than at the mental foramen. And the mental canal most commonly diverged from the mandibular canal below the first premolar by approximately $50^{\circ}$ posterior-superior and $41^{\circ}$ lateral-superior direction, which had with a mean length of 5.19 mm in front of the mental foramen, and exited to the mental foramen below the second premolar. CONCLUSION. These results suggest that it could form a hazardous tetrahedron space at the interforaminal region, thus, the clinician need to pay attention to the width of a premolar tooth from the mental foramen during dental implant placement.

Correction of Lower Eyelid Retraction with Autogenous Hard Palate Mucosa: 2 Case Report (자가 경구개점막 이식을 이용한 하안검 퇴축의 교정: 2례 보고)

  • Kim, Jino;Seul, Chul Hwan;Roh, Tae Suk;Yoo, Woon Min
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.499-502
    • /
    • 2006
  • Purpose: Grave's disease is an autoimmune disease with chronic and systemic features. It affects the orbital fat and muscle bringing about defect in extrinsic eye motility, diplopia, optic nerve defect and lid retraction. In patients with lagopthalmos and resulting facial deformity, treatment can be done by rectus muscle recession or filling with various material. Autogenous auricular cartilage graft is often used and synthetic material such as synthetic acellular dermis, polyethylene meshs are also used for filling of the depressed area. Nevertheless, autogenous auricular cartilage grafts are difficult to utilize and synthetic materials sometimes result in protrusion or infection. Therefore, hard palate mucosa was considered as an alternative. We report two cases of patients with lower eyelid retraction corrected with autogenous hard palate mucosa. Methods: We performed this operation in two patients of Graves' ophthalmopathy. The capsulopalpebral fascia was incised and elevated through an incision on the conjunctiva. Then, the harvested hard palate mucosa was sutured to the inferior border of the tarsus and covered with the conjunctiva. Results: The lower eyelid retraction was corrected successfully. No hypertrophy or deformation of the transplanted hard palate mucosa was noted 6 months after the surgery. Conclusions: From the results above, we may conclude that the hard palate mucosa serves as an ideal spacer for the curvature and the inner lining in lower lid retraction. Hard palate mucosa is as sturdy as the autogenous cartilage but is much easier to utilize. It can be also used for lid retraction after lower lid aesthetic surgeries or traumas.