A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 형상설계에 관한 수치해석)

  • 김기정;배귀남;김영일;허남건
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber (충진층식 세정집진기의 집진특성 실험)

  • 유경훈;노희환;최은수;김종균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

Experiment of Filtration of an Air-Cleaning Filter Combing an Dielectric Filter to an Electrostatic Precipitator with a Perforated Plate (타공판 전기집진기와 유전필터를 조합한 공기청정용 필터의 집진성능 실험)

  • 박석주;임정환;김상도;최호경;박현설;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.413-414
    • /
    • 2001
  • 실내공간에 존재하는 먼지입자를 제거하는데 적용되는 대표적인 방법들로는 섬유상 필터를 이용한 먼지입자 여과 기술과 전기집진기를 이용한 여과 기술이 있다. 섬유상 필터를 이용한 여과 기술은 입자의 관성충돌(inertial impaction), 차단(interception) 및 확산(diffusion) 메카니즘을 이용한 기술로써, 입자포집 효율이 아주 우수한 반면 압력손실이 큰 단점이 있다. 이러한 단점을 개선하기 위하여 개발된 필터로써 정전부착(electrostatic deposition) 메카니즘을 이용한 정전여과필터(electret filter)라고 것이 있는데, 이것은 섬유 자체에 정전 하전을 주입시킨 특수한 필터이다. (중략)

  • PDF

A Theoretical Study on Wet Scavenging of Atmospheric Aerosols by Rain Drops (대기에어로졸 입자의 이론적 강수세정에 관한 연구)

  • 박정호;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 1999
  • In this work, a theoretical model has been formulated which allows the study of the scavenging efficiencies of aerosol particles by the rain drops. Aerosol particles are scavenged by the simultaneous brownian diffusion, interception and inertial impaction force. In addition the calculations based on the collision efficiency model are carried out for the collision of aerosol particles with diameter range 0.01~30 $mu extrm{m}$ and rain drops with diameter 0.02$\times$$2^{n/3}$(n=1, 2, …, 17)cm. The results indicate that: (1) the below-cloud scavenging affects mainly the coarse particles (>3 ${\mu}{\textrm}{m}$), the fine particles remaining almost unchanged; (2) the scavenging efficiencies by below-cloud in the heavy rain (rain intensity, 10 mm/hr) surpass the efficiency found in the drizzle rain (rain intensity, 1 mm/hr).

  • PDF

An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber (덕트형 세정집진기의 입자포집 특성실험)

  • Yoo, Kyung-Hoon;Yeo, Kuk-Hyun;Son, Seung-Woo;Hwang, Kwang-Ho;Jung, Jin-Won;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

Performance Prediction of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 성능예측)

  • Kim Ki-Jung;Bae Gwi-Nam;Kim Youngil;Hur Nahmkeon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.313-316
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^{3}/h$. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and $100m^{3}/h$. The particle collection efficiency of a grease filter increases with increasing the particle diameter and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter The cut-off diameter of the tested grease filter representing $50-{\%}$ collection efficiency is about $11.6{\mu}m$ for water droplets at $100m^{3}/h$.

  • PDF

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통한 정전필터제조 및 특성분석)

  • Ahn, Young-Chull;Kim, Gil-Tae;Kim, Seong-Kon;Lee, Jae-Keun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1134-1138
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, electrical properties and filtration performance of electrospun filter media are quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. Electrospun filters show same collection efficiency with low pressure drop compare to commercialized HEPA filters. Surface charge potential and surface charge density of electrospun filters are increased with increasing applied voltage. Also collection efficiency of electrospun filters is increased with increasing surface charge potential and surface charge density.

  • PDF

A Study on Numerical Calculations of Multi-stage Dedust System coupled with the Collection Principle of Cyclone, Inertial Impaction and Bag filter (II) : Venturi Installation (사이클론과 관성충돌 및 백필터의 제진원리를 일체화한 멀티 제진시스템의 수치 해석적 연구 (II) : 벤츄리 설치)

  • Hong, Sung-Gil;Jung, Yu-Jin;Jeong, Moon-Heon;Park, Ki-Woo;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.371-374
    • /
    • 2012
  • 본 연구는 "사이클론과 관성충돌 및 백필터의 제진원리를 일체화한 고효율 멀티 제진시스템의 최적화 설계를 위한 수치 해석적 연구(I) : 집진기 입구 최적화 설계"에 이은 일련의 연구로서 앞선 연구에서 도출된 사이클론부 하단 벤츄리(Venturi)에서의 강한 하향 기류의 가속에 따른 분진 재비산 가능성에 대한 추가적 검토를 위한 연구이다. 사이클론부를 통과한 기류가 상향 흐름으로 방향을 전환할때 좀 더 가속시켜 빠르게 곡률반경을 형성하여 조대 입자의 분리를 극대화시키기 위한 목적으로 사이클론부 하단을 벤츄리 형상으로 설계하였으나, 유동장 분석 결과 벤츄리를 통과한 처리가스 흐름이 가속되면서 호퍼 하단까지 약 4~5 m/s의 강한 하향 흐름을 형성하고 호퍼 하부의 말단 부근에서 상향 흐름으로 방향 전환을 하고 있는 것으로 예측됨에 따라 설계 의도와는 달리 벤츄리 설치시 호퍼 하단에 포집된 분진의 재비산을 예방하는데는 크게 역할을 하지 못하는 것으로 나타났다.

  • PDF

A Study on Numerical Calculations of Multi-stage Dedust System coupled with the Collection Principle of Cyclone, Inertial Impaction and Bag filter (I) : Optimized Design of Dedust inlet (사이클론과 관성충돌 및 백필터의 제진원리를 일체화한 멀티 제진시스템의 수치 해석적 연구 (I) : 집진기 입구 최적화 설계)

  • Jung, Yu-Jin;Jeong, Moon-Heon;Park, Ki-Woo;Hong, Sung-Gil;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.367-370
    • /
    • 2012
  • 본 연구는 하나의 장치 내에서 "싸이클론-관성충돌-여과포 집진"이라는 다단 제진 단계가 동시에 이루어져 입경 분포별로 순차적인 제진이 가능한 멀티 집진기의 처리가스 제어 효율을 극대화시킬 수 있는 기류 흐름을 얻기 위한 최적화 설계 조건을 검토하는 것이다. 우선 1단계 제진 과정인 원심력을 이용하여 조대입자의 유선 이탈을 촉진시킬 수 있는 사이클론 유동을 최적화시키기 위한 집진기 입구 형상 설계 검토를 위해 수치 해석적 연구를 수행하였다. 그 결과, 멀티집진기 입구 형상을 일반적인 설계 방식인 접선 유입식으로만 설계한 것에 비해 선회류를 한번 더 가속화시킬 수 있는 가이드 베인을 추가로 설계한 경우 선회류의 pitch가 짧고 강하게 형성되어 사이클론부에서 조대입자의 유선 이탈을 촉진시키는데 매우 효과적인 것으로 예측되었다. 단, 사이클론부 하단 벤츄리 형상으로 인해 약 4~5 m/s의 강한 하향 흐름이 호퍼 하단까지 형성되고 있어 탈리 분진의 재비산 문제가 발생할 가능성이 크므로 벤츄리 형상 설치 유무에 대한 영향도 추가적으로 연구가 필요할 것으로 판단된다.

  • PDF

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통해 제조된 정전기 보유 필터의 표면전위 및 대전량에 따른 성능특성 분석)

  • Kim, Gil-Tae;Ahn, Young-Chull;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.820-824
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, the electret filter is made by electrospinning process using Polystyrene which is dissolved by 5 : 5 of Tetrahydrofuran (THF) and Dimethylformamide (DMF). Also the electrical properties and the filtration performances of electrospun filter media are Quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. The surface charge potential and the surface charge density of electrospun PS filters are increased with increasing applied voltage and saturated at 30 kV of applied voltage. Also collection efficiency of electro spun filters is increased with increasing surface charge potential and surface charge density. But the surface charge potential is decreased by natural decay and it causes deterioration of particle collection efficiency.