• Title/Summary/Keyword: Industrial site

Search Result 1,798, Processing Time 0.035 seconds

THE DISTRIBUTION CHARACTERISTICS OF TRACE ELEMENTS IN AIRBORNE PARTICULATES FROM AN URBAN INDUSTRIAL COMPLEX AREA OF KOREA USING INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS

  • LIM JONG-MYOUNG;LEE JIN-HONG;CHUNG YONG-SAM
    • Nuclear Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.503-510
    • /
    • 2005
  • An instrumental neutron activation analysis was used to measure the concentrations of about 24 elements associated with airborne particulates (PM10) that were collected in the most polluted urban region of Daejeon city, Korea from 2000 to 2002. Using the measurement data for various elements, both the extent of elemental pollution in the study area and the seasonality in their distribution characteristics were examined. Examinations of their distribution patterns indicated that most elements with crustal origin tend to exhibit seasonal peaks during spring, while most elements with anthropogenic origin tend to exhibit seasonal peaks during fall or winter. In order to explain the factors regulating their mobilization properties, the data were processed by a factor analysis. Results of the factor analysis suggested competing roles of both industrial and natural source processes, despite that the study site is located at a downwind position of the industrial complex. Based on the overall results of this study, it is concluded that the site may be strongly impacted by man-made sources but the general patterns of elemental distributions in the study area inspected over a seasonal scale are quite consistent with those typically observed from natural environment.

The Color Arrangement of Working Clothes for Visibility in Machine Industrial Work Site

  • Park, Hyewon
    • Journal of Fashion Business
    • /
    • v.17 no.3
    • /
    • pp.1-14
    • /
    • 2013
  • This study is about the evaluation of the color arrangements of working clothes that are harmonized with working environment and assist in the protection of workers in industrial sites. This study attempted color arrangement design with the intention of giving order to the colors of working environment and working clothes so as to help improve the safety of work and the management aspects including human resource management, efficiency improvement, and the practice of business ethics. The study method consisted of literature research, empirical research, and evaluation research. The literature research performed theoretical examination about colors, industrial safety, and visibility. Three actual outdoor work sites in the machine industry were chosen and pictures were taken at 20-30 m from workers. The background colors of the work environment of each work site and the colors of the working clothes that were actually worn were analyzed through color values measured with a color-difference meter(CR-400). As a result, it was found that between value and chroma which affect visibility, color arrangement based on differences in chroma could be a greater influence than color arrangement based on differences in value. The results of this study could assist the integration of color schemes among working environment colors, people and working clothes by suggesting color arrangements with improved visibility that are applicable to the working clothes of domestic machine manufacturers that are playing a pivotal role in domestic industries and by presenting appropriate guidelines.

Comparison of the Concentration of Ambient Volatile Organic Compounds at an Ulsan Industrial Site in 1997 and 1998 (울산 공단 대기에서 측정한 휘발성 유기화합물의 1997년과 1998년 결과 비교)

  • 나광삼;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.567-574
    • /
    • 1999
  • Volatile organic Compounds(VOC) were measured at an industrial site in Ulsan in 1997 and 1998. Twenty-four hour integrated ambient air samples were collected in 6 L SUMMA canisters during the periods of June 3 to 8, 1997 and June 12 to 17, 1998. The daily mean concentrations of the total $C_2-C_9$ VOC in 1998 were about one third of those in 1997. This decrease of VOC levels may be attributable to the measures to control the emissions of VOC and the decrease of the plant operation. The decrease in the concentrations of oxygenated hydrocarbons and alkenes, especially, contributed to the decrease of the total VOC concentrations in 1998. Lowever concentrations of alkenes compared to aromatics in 1998 were due to the decrease of ethylene and propylene. In the present study, methanol (12.0 ppb) was the most abundant species, followed by acetone (10.1 ppb), propane (6.0 ppb), and vinyl chloride (5.9 ppb). The total concentrations of hazardous air pollutants (HAPs) in 1998 were reduced compared to those in 1997. However, this decrease is due to the drastic decrease of the concentration of methanol. Except methanol, the concentrations of HAPs have not varied much. It is suspected that the VOC control strategy for the Ulsan industrial area has been successful for reducing the total VOC levels but might not be effective in reducing the concentrations of HAPs.

  • PDF

Characteristics of Hazardous Air Pollutants in the Steel Industrial City, Pohang (II) - Volatile Organic Compounds (철강산업도시 포항지역 유해대기오염물질의 오염특성 (II) - 휘발성유기화합물)

  • Kim, Min-ji;Seo, Young-Kyo;Cho, Byoung-Yoon;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.244-258
    • /
    • 2018
  • We performed this study to investigate the spatial, seasonal, and daily variations of the concentrations of volatile organic compounds (VOCs) in Pohang, where large steel industrial complexes are located. Ambient air sampling was undertaken at 4 sites during 4 seasons. Each sample was taken for 4 hours continuously for 8 consecutive days per season at each site. Three sites were located within the Pohang city, but one as a control site in Gyeongju. A total of 72 individual VOCs were determined by thermal desorption coupled with GC/MS, including aliphatics, aromatics, carbonyls and halides. The most abundant VOC was toluene, being followed by ethylbenzene and xylenes. Benzene concentrations(c.a. 0.7 ppb) were found to be much lower than the national ambient standard of 1.5 ppb. Overall, the VOCs levels in Pohang appeared to be lower than other national industrial complexes in Korea such as Shiwha-Banwol, Yeosu-Gwangyang, Gumi, and Ulsan. This implies that steel industry may not give significant impacts on the atmospheric levels of VOCs as much as petrochemical, electronic, and/or textile industries, where large amounts of organic solvents are used.

Sensitivity of Air Pollutants Dispersion According to the Selection of Meteorological Data - Case of Seongseo Industrial Complex of Daegu - (기상자료에 따른 대기오염확산 민감도평가 -대구성서산업단지에 대한 사례연구-)

  • Park Myung-Hee;Kim Hae-Dong;Park Mi-Young
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.141-156
    • /
    • 2005
  • The importance of atmospheric conditions for the assessment of an air pollution situation has been demonstrated by their influence on the various compartments of an air pollution system, comprising all stages from emission to effects. Especially, air pollutants dispersion phenomenon are very sensitive according to wind data. But the discussions of how to apply representative meteorological data in air pollution dispersion model are not frequent in Korean environmental assessment processes. In this study, we investigated the difference of air pollutants dispersion phenomenon using U.S EPA ISCLT3 model according to applying the different meteorological data observed at two points for Seongseo industrial complex of Daegu. Two points are the spot site of Seongseo industrial complex and Daegu meteorological observatory. The winds speed of the spot site were smaller than those of Daegu meteorological observatory. In the winter season, the differences came to about $64\%$ for the period$(I\;February\;2001\~31\;January\;2002)$. Wind directions were also fairly different at two points. The air pollutants dispersion phenomenon estimated from our numerical experiments were also fairly different owing to the meteorological conditions at two points.

Magnetization Behavior of Ultra-thin FexCo1-x Alloy on Cr (100) Surface

  • Hossain, M.B.;Kim, C.G.;Chun, B.S.;Kim, W.;Hwang, C.Y.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2013.05a
    • /
    • pp.15-16
    • /
    • 2013
  • Magnetization behavior of ultra thin $Fe_xCo_{1-x}$ alloy (where x varies from 0 to 100) has been investigated as functions of composition on Cr (100) substrate by using in situ surface magneto optical Kerr effect (SMOKE). It's always show in plane uniaxial magnetic anisotropy at room temperature (RT) & Low temperature (LT). It is observed that composition dependent coercive force maximum at about 30 at % Co and 70 at % Co atomic ratio and minimum near equiatomic site. The relative magnetic moments as composition variation also show magnetization collapse near equiatomic site. The magnetization behaviors of Fe-Co alloy on Cr (100) due to composition varies are supported the order-disordering as well as structural stability bcc (ferromagnetic)/fcc (anti-ferromagnetic) phase stability magnetism.

  • PDF

Design and Planning Criteria for the Green Buffer Zone (환경친화적 완충녹지의 기준설정)

  • 박은영;유병림
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.25-35
    • /
    • 2004
  • The purpose of the study is to analyze the existing situation of the green buffer zone in the large scale industrial site and other major residential apartment areas. In this study, it is specifically intended that the planning guideline be upgraded to adopt future landuse trends and thus to suggest design criteria for management of the buffer zone. The framework of the analysis is to review the current landuse, noise reduction, ecological implications and landscape in general. Although the major function of a green buffer zone is considered to protect the residential area from various hazards of industrial, traffic, and visual environment, the situation is that most of the zones are maintained at a minimum level of services by local government. The study carried out intensively almost every type of case studied throughout the country, which implies that the management of the green buffer zone should be expanded physically enough to function for its original objectives. The study recommends that ecological management of the green buffer zone be emphasized and therefore the criteria for this purpose as well as noise issue should be developed prior to the landuse aspects. The study suggests specific guidelines for planning and design for the green buffer zone development. This study should be verified positively through the sustainable monitoring and requires nationwide and overall examination so that it may be applied to whole green spaces.

A Study on Problems and Improvement of Disaster Prevention Technology Guidance(Focused on construction disaster) (재해예방 기술지도의 문제점과 개선방안에 관한 연구 (건설 재해를 중심으로))

  • Roh, Tae-Woo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.47-55
    • /
    • 2016
  • Recently, industrial accidents rate has been gradually decreasing due to the development of safety management methods, but until now, the accident rate in the construction sector is higher than other industries. Large-scale construction sites are operating systematic safety systems to reduce industrial accidents. However, small and medium sized construction sites do not have systematic safety system and lack safety management ability, so that disaster is not reduced compared with large scale construction site. As a result, disaster prevention technology instruction system has been implemented to reduce the disasters of small and medium scale construction sites. However, in the case of a small construction site less than 2 billion won, there is little decrease in the accident rate, and in some cases, the accident rate increases. After the technical guidance system has been implemented, it is necessary to identify the performance and problems of implementation and to improve its effectiveness. In this study, we suggest the improvement plan to improve the efficiency of the technical guidance system by analyzing the problems and actual conditions of technical guidance operation in small and medium sized construction work sites.

A Study on the Comparison of Atmospheric Concentrations of Volatile Organic Compounds in a Large Urban Area and a Sub-Urban Area (대도시 및 주변 교외지역의 대기 중 휘발성 유기화합물 농도 비교에 관한 연구)

  • Park, Ji-Hyae;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.767-778
    • /
    • 2006
  • This study was carried out to evaluate the temporal variations of VOCs at an urban site, and to compare the concentrations of VOCs at an urban site in Daegu with those at a suburban site in Gyeongsan. Three hourly VOC samples in the ambient air were collected using a sequential tube sampler (STS 25, Perkin Elmer) throughout two weeks during May and July representing spring and summer seasons, respectively. The VOC concentrations were determined by an automatic thermal desorption apparatus with GC/MS analysis. A total of 12 VOCs of environmental concern were determined, which are chloroform, benzene, trichloroethylene, toluene, tetra-chloroethylene, ethylbenzene, m+p-xylenes, o-xylene, styrene, 1,3,5- and 1,2,4-trimethylbenzenes. Among 12 target VOCs, the most abundant compound appeared to be toluene, being followed by xylenes. The mean concentrations at the urbn site were 1.2 pub for benzene and 20.4 ppb for toluene (n=221) while the mean levels at the suburban site were 0.9 ppb and 4.3 ppb for benzene and toluene (n=96), respectively. The urban site concentrations were typically several-fold higher than those measured at the suburban site. It was found that general trends of VOC levels were significantly dependent on traffic conditions at the sampling site since VOC concentrations were at their maximum during rush hours, i.e. $9{\sim}12a.m$ and $6{\sim}9p.m$. Statistical investigations were conducted to investigate any significant relationships between VOC concentrations and affecting factors. Calculated correlation coefficients among VOCs were positively significant at a level of 0.05 in most cases. Increased concentrations of toluene in the urban site were estimated to reflect the effect of large industrial sources, mainly from textile industry.

A GUI-based the Recognition System for Measured Values of Digital Instrument in the Industrial Site (GUI기반 산업용 디지털 기기의 측정값 인식 시스템)

  • Jeon, Min-sik;Ko, Bong-jin
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.5
    • /
    • pp.496-502
    • /
    • 2016
  • In this paper, we proposed and implemented a GUI-based system to recognize and record measured values of digital instruments in the industrial site through image processing. Unlike the existing vehicle license plate recognition system, the measured values of the measuring instrument are displayed on the LCD screen as digital numbers. So, the proposed system considers the decimal point, a negative sign, light reflected by LCD protective glass, and various disturbance factors. We used blob-labeling technique to recognize the numbers displayed on the LCD screen, the recognized number images were determined as certain numbers through the template matching, and recognized values were recorded in the storage device with measurement time. Therefore, the proposed system in this paper would reduce the burden of writing when recording the measured values of the inside/outside diameter or height of the product in the industrial site, so effective and errorless process management in production process is possible by preventing errors in recording measurements when written by hand.