• 제목/요약/키워드: Industrial scientific medical(ISM) band

검색결과 66건 처리시간 0.026초

2.4Ghz ISM(Industrial Scientific Medical) 밴드에서 간섭을 회피하기 위한 무선 센서 노드의 채널 선택 방법 (Channel Selection Method of Wireless Sensor Network Nodes for avoiding Interference in 2.4Ghz ISM(Industrial, Scientific, Medical) Band)

  • 김수민;금동현;김경훈;오일;최승원
    • 디지털산업정보학회논문지
    • /
    • 제10권4호
    • /
    • pp.109-116
    • /
    • 2014
  • In recent, ISM (Industrial Scientific Medical) band that is 2.4GHz band authorized free of charge is being widely used for smart phone, notebook computer, printer and portable multimedia devices. Accordingly, studies have been continuously conducted on the possibility of coexistence among nodes using ISM band. In particular, the interference of IEEE 802.11b based Wi-Fi device using overlapping channel during communication among IEEE 802.15.4 based wireless sensor nodes suitable for low-power, low-speed communication using ISM band causes serious network performance deterioration of wireless sensor networks. This paper examined a method of identifying channel status to avoid interference among wireless communication devices using IEEE 802.11b (Wi-Fi) and other ISM bands during communication among IEEE 802.15.4 based wireless sensor network nodes in ISM band. To identify channels occupied by Wi-Fi traffic, various studies are being conducted that use the RSSI (Received Signal Strength Indicator) value of interference signal obtained through ED (Energy Detection) feature that is one of IEEE 802.15.4 transmitter characteristics. This paper examines an algorithm that identifies the possibility of using more accurate channel by mixing utilization of interference signal and RSSI mean value of interference signal by wireless sensor network nodes. In addition, it verifies such algorithm by using OPNET Network verification simulator.

의료용 무선 중계 시스템용 이중 대역 인체 부착형 안테나 설계 (Design of a Dual-Band On-Body Antenna for a Wireless Medical Repeater System)

  • 권결;탁진필;최재훈
    • 한국전자파학회논문지
    • /
    • 제24권3호
    • /
    • pp.239-246
    • /
    • 2013
  • 본 논문에서는 MICS(Medical Implant Communication Service, 402~405 MHz)와 ISM(The Industrial, Scientific and Medical, 2.40~2.485 GHz) 대역에서 동작하는 의료용 무선 중계 시스템을 위한 이중 대역 인체 부착형 안테나를 제안하고, 인체의 영향을 고려한 안테나 성능에 대한 분석을 하였다. 제안된 안테나는 ISM 대역에서 동작하는 윗면의 패치와 MICS 대역에서 동작하는 바닥면의 패치로 구성되어 있다. 안테나가 실제 인체에 착용되어 사용되는 상황을 고려하고, 인체가 안테나에 미치는 영향을 분석하기 위하여 모의 인체를 이용하여 시뮬레이션과 측정을 수행하였다. 제안된 안테나의 반사 손실은 MICS 대역과 ISM 대역에서의 요구 대역폭을 만족하였고, 측정된 최대 이득은 MICS 대역과 ISM 대역에서 각각 -12.47 dBi, 1.71 dBi이었다. 제안된 안테나의 방사 패턴은 MICS 대역에서 인체 내부 지향성, ISM 대역에서 인체 외부 지향성을 가지며, 반사 손실 특성은 인체의 영향에 매우 둔감하므로 의료용 무선 중계 시스템용 인체 부착형 안테나로 활용되기에 적절할 것으로 사료된다.

ISM 밴드용 임베디드 기기를 위한 전자기 혼신신호의 송신전력 제한치 도출 (Calculating Emission Power Limits of Electromagnetic Disturbance Signal for Embedded Systems in ISM Bands)

  • 조면균;김식
    • 대한임베디드공학회논문지
    • /
    • 제5권3호
    • /
    • pp.136-143
    • /
    • 2010
  • Embedded systems widely used for wireless communication such as W-LAN, Bluetooth and ZigBee operate on ISM (Industrial, Scientific and Medical) band but they can be seriously affected by electromagnetic interference radiated from ISM apparatus. Therefore C.I.S.P.R. reports proposed limits for the protection of telecommunication from interference from ISM equipment. In this paper, we clarify the methods for calculating limits for disturbance signal for Embedded Systems in ISM band and propose simple way of calculating limits for interference signal in both above and below 1 GHz band cases.

2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석 (Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band)

  • 심용섭;이일규
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.101-105
    • /
    • 2011
  • 본 논문은 2.3 GHz 대역을 사용하는 ISM(Industrial Scientific Medical) 기기가 동대역을 사용하는 WiBro 서비스에 미치는 간섭 영향을 분석하여 ISM 기기로부터 WiBro 서비스를 보호하기 위한 보호 거리를 산출하였다. 간섭 시나리오로 ISM 기기의 간섭 파워는 CISPR(International Special Committee on Radio Interference) 11의 전계강도 기준치를 적용하였고 WiBro 수신기가 ISM 기기로 근접하는 경우를 구성하여 분석하였다. 그 결과 최악의 상황을 고려한 MCL(Minimum Coupling Loss) 분석시 14 m의 보호 거리와 통계적 간섭 확률을 바탕으로 한 MC(Monte Carlo) 분석시 간섭원의 수가 1개 일 때 간섭 확률 5 %를 만족하기 위해 10 m의 보호 거리가 각각 산출되었다.

ISM 밴드 RF 모듈의 수신감도 향상에 관한 연구 (The Research about improvement of receive sensitivity for RF module in ISM band)

  • 이혁진;양오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.613-616
    • /
    • 2002
  • This paper has been studied an improvement of receive sensitivity for RF module of Industrial Scientific Medical(ISM) Band. In the paper, Also this paper handles receive sensitivity progress of RF module in ISM band. how to improve receive sensitivity adds to Surface Acoustic Wave(SAW) filter, Low Noise Filter(LNA), etc and insulates receiver and transmitter. And then the circuit is inspected by the effective range test of receiver and transmitter. And this Paper was designed that micro-controler controls the part of RF by software.

  • PDF

MICS와 ISM 대역을 위한 인체 통신 중계용 안테나 설계 (Design of a WBAN Repeater Antenna for MICS and ISM Bands)

  • 이호주;권결;이순용;최재훈
    • 한국전자파학회논문지
    • /
    • 제23권3호
    • /
    • pp.314-319
    • /
    • 2012
  • 본 논문에서는 MICS(Medical Implant Communication Service, 402~405 MHz)와 ISM(The Industrial, Scientific and Medical, 2.40~2.48 GHz) 대역에서 동작하는 인체 통신 중계용 안테나를 제안하고, 인체의 영향을 고려한 안테나 성능에 대한 분석을 하였다. 제안된 안테나는 loop 안테나와 영차 공진 안테나로 구성되어 있다. Loop 안테나는 ISM 대역에서 동작하며, MICS 대역에서의 동작은 loop 안테나와 영차 공진기의 용량성 결합에 의해 요구 성능을 만족할 수 있도록 구현하였다. 근거리장에 인체가 존재할 때 인체가 안테나에 미치는 영향을 분석하기 위하여 인체 팬텀을 이용하여 시뮬레이션과 측정을 하였다. 시뮬레이션 및 측정 결과, 제안된 안테나는 MICS와 ISM 대역에서 대역폭을 만족하였고, 측정된 이득값은 MICS 대역에서 -28.53 dBi, ISM 대역에서 3.85 dBi였다. 또한, 설계된 안테나의 이중 대역 특성은 인체 내 외부 간의 통신 중계 용도로 적절하다고 사료된다.

MIMO 구조의 마이크로스트립 패치 안테나 분석 (Analysis Microstrip Patch Antenna of MIMO Structure)

  • 김선웅;박정진;최동유
    • 한국통신학회논문지
    • /
    • 제40권5호
    • /
    • pp.944-949
    • /
    • 2015
  • 본 논문에서는 단일 패치 안테나에 다중 포트를 결합하여 무선 통신 기기의 응용에 적합한 MIMO구조의 패치 안테나를 제안하였다. 제안된 MIMO 패치 안테나는 비 유전율 4.5, 손실 탄젠트 0.0035, 두께 1.52 mm를 갖는 TRF-45 기판을 통해 설계되었으며, 안테나의 중심 주파수는 ISM (Industrial Scientific and Medical) 대역의 2.45 GHz이다. 제안된 MIMO 패치 안테나는 2.16 ~ 2.66 GHz 대역에서 500 MHz의 대역폭을 보였으며, 비 대역폭은 24.1%이다. 안테나의 반사손실 및 정재파비 결과는 제안된 대역에서 2.45 GHz의 ISM 대역에서 -62.05 dB, 1.01이다. 대역폭에 포함된 각각의 대역은 2.3 GHz의 WiBro 대역은 -17.43 dB, 1.33, 2.4 GHz의 WiFi 대역은 -31.89 dB, 1.05, 2.5 GHz의 WiMax 대역은 -36.47 dB, 1.03이다. 대역폭에 포함된 대역의 방사패턴 분석은 지향성의 패턴을 보였으며, 2.3 GHz의 WiBro 대역은 4.22 dBi, 2.4 GHz의 WiFi 대역은 4.12 dBi, 2.45 GHz의 ISM 대역은 4.06 dBi, 2.5 GHz의 WiMax 대역은 3.96 dBi의 이득을 보였다.

MB-OFDM에서 충돌회피를 위한 결정궤환방식의 간섭신호 검출 기법 (Detection algorithm for DAA using Decision Directed method in MB-OFDM)

  • 오우진
    • 한국정보통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.315-321
    • /
    • 2011
  • MB-OFDM(Multi-Band Orthogonal Frequency Division Multiplexing)은 ISM(Industrial, Scientific and Medical) 대역을 사용하는 초 광대역 통신으로 기존 통신 시스템과 공존하기 위해서 검출 및 회피 기법인 DAA(Detect-And-Avoid)을 사용하는 것이 요구되고 있다. 본 논문에서는 DAA를 위한 간섭신호 검출 방식으로 결정궤환 방식을 제안하여 기존의 방법에 비하여 수렴 속도가 빠르고 간단히 구현할 수 있는 특징을 갖고 있다. 제안된 방식은 AWGN(Additive White Gaussian Noise), 및 LOS(Line-Of-Sight)채널에서는 -20dB의 간섭까지 검출하는 우수한 성능을 보이고 있다. 또한 비 LOS 채널에서는 적절한 채널 클리핑을 통하여 AWGN 채널에 근사한 성능을 제시하였다.

개구 결합된 십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나 (Dual-Band Microstrip Antenna for ISM Band using Aperture Coupled Cross Patch)

  • 박기동;정문숙;임영석
    • 한국전자파학회논문지
    • /
    • 제14권5호
    • /
    • pp.479-488
    • /
    • 2003
  • 시간영역 유한차분법을 이용하여 2.4 GHz와 5.8 GHz외 ISM 대역을 위한 이중대역 마이크로스트립 안테나를 설계한다. 2개의 구형 패치가 겹쳐진 십자형 패치를 안테나의 방사소자로 제안하고 급전 방식은 개구 결합을 이용한다. 안테나 설계를 위해 개구와 스터브 길이 변화에 따른 입력 임피던스의 변화를 살펴보고, 방사소자의 길이와 폭 변화에 따른 중심 주파수와 -10 dB대역폭을 고찰한다 반사손실에 대한 계산 결과를 IE3D의 해석 결과 및 측정 결과와 비교하여 잘 일치함을 확인하고, 주파수 2.43 GHz와 5.79 GHz에서 안테나의 방사패턴을 측정하여 -3 dB 빔폭, 전후방비 및 최대 이득을 제시한다.

십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나 설계 (Design of Dual-band Microstrip Antenna for ISM Bandwidth using Cross Patch)

  • 박기동;정문숙;임영석
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.241-245
    • /
    • 2002
  • Dual-band microstrip antenna is designed for industrial-scientific-medical(ISM) band of 2.4㎓ and 5.8㎓ using finite-difference time-domain method(FDTD). Cross Patch fed by aperture in the ground plane of microstrip line is proposed as radiation element of antenna, which is 2 rectangular Patch is overlapped. To design antenna, change of input impedance by aperture and stub length change is examined. And it is investigated that center frequency and -10 ㏈ bandwidth by Length of radiation element and width change. Experimental result about reflection Loss confirmed that agree well with analysis results of FDTD and IE3D, And -3 ㏈ beam width, front to back ratio and gain in frequency 2.43㎓ and 5.79㎓ is presented by measuring radiation Pattern of antenna.

  • PDF