• Title/Summary/Keyword: Industrial scientific medical(ISM) band

Search Result 66, Processing Time 0.03 seconds

Channel Selection Method of Wireless Sensor Network Nodes for avoiding Interference in 2.4Ghz ISM(Industrial, Scientific, Medical) Band (2.4Ghz ISM(Industrial Scientific Medical) 밴드에서 간섭을 회피하기 위한 무선 센서 노드의 채널 선택 방법)

  • Kim, Su Min;Kuem, Dong Hyun;Kim, Kyung Hoon;Oh, Il;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.109-116
    • /
    • 2014
  • In recent, ISM (Industrial Scientific Medical) band that is 2.4GHz band authorized free of charge is being widely used for smart phone, notebook computer, printer and portable multimedia devices. Accordingly, studies have been continuously conducted on the possibility of coexistence among nodes using ISM band. In particular, the interference of IEEE 802.11b based Wi-Fi device using overlapping channel during communication among IEEE 802.15.4 based wireless sensor nodes suitable for low-power, low-speed communication using ISM band causes serious network performance deterioration of wireless sensor networks. This paper examined a method of identifying channel status to avoid interference among wireless communication devices using IEEE 802.11b (Wi-Fi) and other ISM bands during communication among IEEE 802.15.4 based wireless sensor network nodes in ISM band. To identify channels occupied by Wi-Fi traffic, various studies are being conducted that use the RSSI (Received Signal Strength Indicator) value of interference signal obtained through ED (Energy Detection) feature that is one of IEEE 802.15.4 transmitter characteristics. This paper examines an algorithm that identifies the possibility of using more accurate channel by mixing utilization of interference signal and RSSI mean value of interference signal by wireless sensor network nodes. In addition, it verifies such algorithm by using OPNET Network verification simulator.

Design of a Dual-Band On-Body Antenna for a Wireless Medical Repeater System (의료용 무선 중계 시스템용 이중 대역 인체 부착형 안테나 설계)

  • Kwon, Kyeol;Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.239-246
    • /
    • 2013
  • In this paper, a dual-band on-body antenna operating at MICS and ISM band for a wireless medical repeater system is proposed and the antenna performance including the human body effect is investigated. The designed dual-band antenna is comprised of a top patch for ISM band and bottom patch for MICS band. Simulation and measurement was carried out in order to analyze the effects of human body on antenna performance considering real use. The proposed antenna has required impedance bandwidth enough to cover both MICS and ISM bands. The measured peak gains were -12.47 dBi and 1.71 dBi at the each center frequency of MICS and ISM bands, respectively. Furthermore, the antenna has the maximum radiation directed toward the inside of the human body in the MICS band and directed toward the outside in the ISM band. In addition, the return loss property of the antenna is insensitive to human body effects so that the proposed antenna is well suited for the on-body wireless medical repeater system.

Calculating Emission Power Limits of Electromagnetic Disturbance Signal for Embedded Systems in ISM Bands (ISM 밴드용 임베디드 기기를 위한 전자기 혼신신호의 송신전력 제한치 도출)

  • Cho, Myeon-Gyun;Kim, Shik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.3
    • /
    • pp.136-143
    • /
    • 2010
  • Embedded systems widely used for wireless communication such as W-LAN, Bluetooth and ZigBee operate on ISM (Industrial, Scientific and Medical) band but they can be seriously affected by electromagnetic interference radiated from ISM apparatus. Therefore C.I.S.P.R. reports proposed limits for the protection of telecommunication from interference from ISM equipment. In this paper, we clarify the methods for calculating limits for disturbance signal for Embedded Systems in ISM band and propose simple way of calculating limits for interference signal in both above and below 1 GHz band cases.

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.

The Research about improvement of receive sensitivity for RF module in ISM band (ISM 밴드 RF 모듈의 수신감도 향상에 관한 연구)

  • Lee, Hyuck-Jin;Yang, Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.613-616
    • /
    • 2002
  • This paper has been studied an improvement of receive sensitivity for RF module of Industrial Scientific Medical(ISM) Band. In the paper, Also this paper handles receive sensitivity progress of RF module in ISM band. how to improve receive sensitivity adds to Surface Acoustic Wave(SAW) filter, Low Noise Filter(LNA), etc and insulates receiver and transmitter. And then the circuit is inspected by the effective range test of receiver and transmitter. And this Paper was designed that micro-controler controls the part of RF by software.

  • PDF

Design of a WBAN Repeater Antenna for MICS and ISM Bands (MICS와 ISM 대역을 위한 인체 통신 중계용 안테나 설계)

  • Lee, Ho-Joo;Kwon, Kyeol;Lee, Soon-Yong;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.314-319
    • /
    • 2012
  • In this paper, a repeater antenna operating at MICS and ISM bands is proposed and the antenna performance including the human body effect is investigated. The proposed antenna is composed of a ZOR(Zeroth Order Resonator) and a loop antenna. A loop antenna is operated at ISM band and a loop antenna capacitively coupled with a ZOR acts as an antenna for MICS band. Simulation was carried out in order to analyze the effects of human body on antenna performance when a human body is located in the near field of an antenna. According to the simulated and measured results, the proposed antenna has -10 dB $S_{11}$ bandwidth wide enough to cover both MICS and ISM bands. The measured peak gains are -28.53 dBi and 3.85 dBi at MICS and ISM band, respectively. The dual band and radiation properties of the proposed antenna are well suited for the WBAN repeater system.

Analysis Microstrip Patch Antenna of MIMO Structure (MIMO 구조의 마이크로스트립 패치 안테나 분석)

  • Kim, Sun-Woong;Park, Jung-Jin;Choi, Dong-You
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.944-949
    • /
    • 2015
  • This study proposed a patch antenna with a MIMO structure which is applicable for wireless communication equipment by combining a single patch antenna with a multi port. The proposed MIMO patch antenna was designed through the TRF-45 substrate with a relative permittivity of 4.5, loss tangent equal to 0.0035 and dielectric high of 1.6 mm, and the center frequency of the antenna was 2.45 GHz in the ISM (Industrial Scientific and Medical) band. The proposed MIMO patch antenna had a 500 MHz bandwidth from 2.16 ~ 2.66 GHz and 24.1% fractional bandwidth. The return loss and VSWR were -62.05 dB, 1.01 at the ISM bandwidth of 2.45 GHz. The Wibro band of 2.3 GHz was -17.43 dB, 1.33, the WiFi band of 2.4 GHz was -31.89 dB, 1.05, and the WiMax band of 2.5 GHz was -36.47 dB, 1.03. The radiation patterns included in the bandwidth were directional, and the WiBro band of 2.3 GHzhad a gain of 4.22 dBi, the WiFi band of 2.4 GHz had a gain of 4.12 dBi, the ISM band of 2.45 GHz had a gain of 4.06dBi, and the WiMax band of 2.5 GHz had a gain of 3.9 6dBi.

Detection algorithm for DAA using Decision Directed method in MB-OFDM (MB-OFDM에서 충돌회피를 위한 결정궤환방식의 간섭신호 검출 기법)

  • Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.315-321
    • /
    • 2011
  • Since the MB-OFDM(Multi-Band Orthogonal Frequency Division Multiplexing) is an ultra wideband communication system operated on ISM(Industrial, Scientific and Medical) band, DAA(Detect-And-Avoid) is required for co-existence with the other communication service. In this paper we propose the new detection algorithm based on decision-feedback, which shows faster convergence time and less complexity than previous works. The proposed algorithm detects interference above -20dB in AWGN(Additive White Gaussian Noise) and LOS(Line-Of-Sight) channel, and close to AWGN in non-LOS channel under appropriate channel clipping.

Dual-Band Microstrip Antenna for ISM Band using Aperture Coupled Cross Patch (개구 결합된 십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나)

  • 박기동;정문숙;임영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.479-488
    • /
    • 2003
  • Dual-band microstrip antenna is designed for industrial-scientific-medical(ISM) band of 2.4 GHz and 5.8 GHz using finite-difference time-domain method(FDTD). Cross patch 130 by aperture in the ground plane of microstrip line is proposed as radiation element of antenna which is 2 rectangular patch is overlapped. To design antenna, change of input impedance is examined by length change of aperture and stub. And center frequency and - 10 dB bandwidth are investigated by change of length and width in radiation element. Measured result about reflection loss confirm that agree well with simulation results of FDTD and IE3D. And 3 dB beam width, front to back ratio and maximum gain is presented by measuring radiation pattern of antenna in frequency 2.43 GHz and 5.79 GHz.

Design of Dual-band Microstrip Antenna for ISM Bandwidth using Cross Patch (십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나 설계)

  • 박기동;정문숙;임영석
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.241-245
    • /
    • 2002
  • Dual-band microstrip antenna is designed for industrial-scientific-medical(ISM) band of 2.4㎓ and 5.8㎓ using finite-difference time-domain method(FDTD). Cross Patch fed by aperture in the ground plane of microstrip line is proposed as radiation element of antenna, which is 2 rectangular Patch is overlapped. To design antenna, change of input impedance by aperture and stub length change is examined. And it is investigated that center frequency and -10 ㏈ bandwidth by Length of radiation element and width change. Experimental result about reflection Loss confirmed that agree well with analysis results of FDTD and IE3D, And -3 ㏈ beam width, front to back ratio and gain in frequency 2.43㎓ and 5.79㎓ is presented by measuring radiation Pattern of antenna.

  • PDF