• Title/Summary/Keyword: Industrial control network

Search Result 752, Processing Time 0.025 seconds

A Study of Authentication Method for Id-Based Encryption Using In M2M Environment (M2M 환경에서 신원기반 암호기법을 활용한 인증기법에 관한 연구)

  • Jin, Byung-Wook;Park, Jae-Pyo;Lee, Keun-Wang;Jun, Mun-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1926-1934
    • /
    • 2013
  • M2M (Machine-to-Machine Communication) refers to technologies that allow wired and wireless systems to communicate with other devices with similar capabilities. M2M has special features which consist of low electricity consumption, cheap expenses, WAN, WLAN and others. Therefore, it can communicate via a network. Also, it can handle itself without a person's management. However, it has a wireless-communicate weakness because of the machine-communicate request, and also it is difficult to administrate and control each other. So In this Paper, It suggests the safety protocol between Device, Gateway and Network Domain in M2M environment. Proposed protocol is based on ID-Based encryption's certificate and creates session key between the Access Server and the Core Server in the Network Domain. It uses that session key for sending and receiving data in mutual, and adds key renewal protocol so it will automatically update discern result. a comparative analysis of the existing M2M communication technologies and PKI-based certificate technology is compared with the proposed protocol efficiency and safety.

A Study on NOx Emission Control Methods in the Cement Firing Process Using Data Mining Techniques (데이터 마이닝을 이용한 시멘트 소성공정 질소산화물(NOx)배출 관리 방법에 관한 연구)

  • Park, Chul Hong;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.739-752
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the relationship between kiln processing parameters and NOx emissions that occur in the sintering and calcination steps of the cement manufacturing process and to derive the main factors responsible for producing emissions outside emission limit criteria, as determined by category models and classification rules, using data mining techniques. The results from this study are expected to be useful as guidelines for NOx emission control standards. Methods: Data were collected from Precalciner Kiln No.3 used in one of the domestic cement plants in Korea. Thirty-four independent variables affecting NOx generation and dependent variables that exceeded or were below the NOx emiision limit (>1 and <0, respectively) were examined during kiln processing. These data were used to construct a detection model of NOx emission, in which emissions exceeded or were below the set limits. The model was validated using SPSS MODELER 18.0, artificial neural network, decision treee (C5.0), and logistic regression analysis data mining techniques. Results: The decision tree (C5.0) algorithm best represented NOx emission behavior and was used to identify 10 processing variables that resulted in NOx emissions outside limit criteria. Conclusion: The results of this study indicate that the decision tree (C5.0) can be applied for real-time monitoring and management of NOx emissions during the cement firing process to satisfy NOx emission control standards and to provide for a more eco-friendly cement product.

Design of Fault Diagnostic and Fault Tolerant System for Induction Motors with Redundant Controller Area Network

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.371-374
    • /
    • 2004
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Preventive maintenance of induction motors has been a topic great interest to industry because of their wide range application of industry. Since the use of mechanical sensors, such as vibration probes, strain gauges, and accelerometers is often impractical, the motor current signature analysis (MACA) techniques have gained murk popularity as diagnostic tool. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is independent of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current, voltage, temperatures, vibration and speed of the motor. The DSPs share information from each sensor or DSP through DPRAM with hardware implemented semaphore. And it communicates the motor status through field bus (CAN, RS485). From the designed system, we get primitive sensors data for the case of normal condition and two abnormal conditions of 3 phase induction motor control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using CAN protocol.

  • PDF

Performance Analysis using Markov chain in WiBro (WiBro에서 마코프 체인을 이용한 성능분석)

  • Park, Won-Gil;Kim, Hyoung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.190-197
    • /
    • 2010
  • The ACR (Access Control Router) of WiBro processes location registration of the Correspondent Node and Home Agent as the Correspondent Node moves between ACRs. Therefore, the location update cost is low compared with MIPv6. However, all packets which are sent and received are sent through the ACR, so as the number of mobile nodes that are managed by the ACR increases, the cost of packet delivery also increases. Therefore, the communication state of the ACR domain remains smooth when the ACR which manages the mobile node in the ACR domain has good performance. However, network delays occur unless the ACR performs well, so the role of the ACR is important. In this paper, we analysis performance of the ACR for efficient realization of the WiBro standard. By using the Deny Probability and the Total Profit of ACR performance and apply it to the Random Walk Mobility model as the mobility model.

Design of Network-Based Induction Motors Fault Diagnosis System Using Redundant DSP Microcontroller with Integrated CAN Module (DSP 마이크로컨트롤러를 사용한 CAN 네트워크 기반 유도전동기고장진단 시스템 설계)

  • Yoon, Chung-Sup;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.80-86
    • /
    • 2005
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is includes of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module processes the stator current, voltage, temperatures, vibration signal of the motor.

Adaptive Bandwidth Control System with Incoming Traffic in Home Network

  • Shin Hye Min;Kim Hyoung Yuk;Lee Ho Chan;Kim Hong Seok;Park Hong Seong
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.147-151
    • /
    • 2004
  • QoS is a subject of high interest for successful deployment of various services in a home gateway and the gateway is possible to support QoS by installing existing queuing disciplines, which control the outgoing traffic to guarantee only QoS of the traffic. But m the home gateway it is also important to guarantee QoS of the incoming traffic. This paper proposes an adaptive control of the traffic to guarantee QoS of incoming traffic into the home gateway. In the proposed method, the upper limit of the available bandwidth of sending rate varies with receiving rate. And the proposed method makes the gap between the allocated rate and the actual service rate of the traffic narrow. Some experiments on a test bed show that the proposed method is valid.

  • PDF

Control and Monitoring Process Industrial Automation based on SCADA system using Android Smartphone (안드로이드 스마트폰을 이용한 SCADA 시스템 기반의 제어및모니터링 과정산업자동화)

  • Budhi, Prayoga;Isnanto, Isnanto;Kim, Jeong-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.126-127
    • /
    • 2013
  • In industry, Supervisory Control and Data Acquisition (SCADA) system plays critical role to ensure production is monitored and controlled rigorously and in timely manner. Having a cost saving yet still effective SCADA system would be much desired by Industry. SCADA itself is a field with constant development and research like how this paper investigates on creating an extremely low cost device, which can be adapted to many different SCADA applications through some very basic programming when combined with relevant peripherals. Much of the process in some expensive SCADA application based on smartphone application is due to specialized communication infrastructure. This paper addresses the needs by developing low cost and integrated wireless SCADA system. The system features capability on accessing the performance of remotely situated device parameter, such as temperature, control analog or digital input output on real time basis. We use existing mobile network capability through Bluetooth communication channel.

  • PDF

Development of High Performance LonWorks Based Control Modules for Network-based Induction Motor Control

  • Kim, Jung-Gon;Hong, Won?Pyo;Yun, Byeong-Ju;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.414-420
    • /
    • 2005
  • The ShortStack Micro Server enables any product that contains a microcontroller or microprocessor to quickly and inexpensively become a networked, Internet-accessible device. The ShortStack Micro Server provides a simple way to add LonWorks networking to new or existing smart devices. . It implements the LonTalk protocol and provides the physical interface with the LonWorks communication. The ShortStack host processor can be an 8, 16, or 32-bit microprocessor or microcontrollers. The ShortStack API and driver typically require about 4kbytes of program memory on the host processor and less than 200 bytes of RAM. The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface (SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShortStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

A CYBER SECURITY RISK ASSESSMENT FOR THE DESIGN OF I&C SYSTEMS IN NUCLEAR POWER PLANTS

  • Song, Jae-Gu;Lee, Jung-Woon;Lee, Cheol-Kwon;Kwon, Kee-Choon;Lee, Dong-Young
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.919-928
    • /
    • 2012
  • The applications of computers and communication system and network technologies in nuclear power plants have expanded recently. This application of digital technologies to the instrumentation and control systems of nuclear power plants brings with it the cyber security concerns similar to other critical infrastructures. Cyber security risk assessments for digital instrumentation and control systems have become more crucial in the development of new systems and in the operation of existing systems. Although the instrumentation and control systems of nuclear power plants are similar to industrial control systems, the former have specifications that differ from the latter in terms of architecture and function, in order to satisfy nuclear safety requirements, which need different methods for the application of cyber security risk assessment. In this paper, the characteristics of nuclear power plant instrumentation and control systems are described, and the considerations needed when conducting cyber security risk assessments in accordance with the lifecycle process of instrumentation and control systems are discussed. For cyber security risk assessments of instrumentation and control systems, the activities and considerations necessary for assessments during the system design phase or component design and equipment supply phase are presented in the following 6 steps: 1) System Identification and Cyber Security Modeling, 2) Asset and Impact Analysis, 3) Threat Analysis, 4) Vulnerability Analysis, 5) Security Control Design, and 6) Penetration test. The results from an application of the method to a digital reactor protection system are described.

Analysis of Experience Knowledge of Shooting Simulation for Training Using the Text Mining and Network Analysis (Text Mining과 네트워크 분석을 활용한 교육훈련용 모의사격 시뮬레이션 경험지식 분석)

  • Kim, Sungkyu;Son, Changho;Kim, Jongman;Chung, Sehkyu;Park, Jaehyun;Jeon, Jeonghwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.700-707
    • /
    • 2017
  • Recently, the military need more various education and training because of the increasing necessity of various operation. But the education and training of the military has the various difficulties such as the limitations of time, space and finance etc. In order to overcome the difficulties, the military use Defense Modeling and Simulation(DM&S). Although the participants in training has the empirical knowledge from education and training based on the simulation, the empirical knowledge is not shared because of particular characteristics of military such as security and the change of official. This situation obstructs the improving effectiveness of education and training. The purpose of this research is the systematizing and analysing the empirical knowledge using text mining and network analysis to assist the sharing of empirical knowledge. For analysing texts or documents as the empirical knowledge, we select the text mining and network analysis. We expect our research will improve the effectiveness of education and training based on simulation of DM&S.