• Title/Summary/Keyword: Industrial Standard Protocol

Search Result 74, Processing Time 0.041 seconds

A Study on Development of Conversion Software for Controller Without OPC Stack to Communicate With OPC DA Client (OPC 스택이 없는 제어기와 OPC DA 클라이언트를 통신시키는 변환 소프트웨어 개발에 관한 연구)

  • Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.319-326
    • /
    • 2015
  • This paper proposes method about development of conversion software for controller without OPC stack to communicate with OPC DA client. The proposed method is composed of development of OPC server based on OPC DA standard protocol, development of GUI application can be checked the OPC tag and point informations, development of conversion module to convert from OPC protocol to open standard protocol. In the stage of development of OPC server based on OPC DA standard protocol, we develope server in the pc to transmit and receive datum through OPC DA protocol with OPC DA client. In the stage of evelopment of GUI application can be checked the OPC tag and point informations, run the OPC DA server and register to window system registry and check OPC tags, points, transmitting and receiving of data from serial communication. In the stage of development of conversion module to convert from OPC protocol to open standard protocol, convert from OPC tag data which has received from OPC DA client to protocol can be communicated with industrial controller using open standard protocol so that support to transmit and receive data. To evaluate the efficiency of the proposed software, we connected OPC DA server software and OPC client, and 5 sample industrial controller which use open standard protocol, as a result we got 96.98% average communication succeeding rate among entire transmitting and receiving packets. We also confirmed that successfully communicated between industrial building controller which uses modbus protocol and industrial OPC DA client using OPC DA conversion software proposed by this dissertation.

Development of the Protocol Integration System with Multi-threading Method for the Ship Electronic Device (Multi-threading 기법을 적용한 선박 전자장치 프로토콜 통합 시스템의 구현)

  • Kim, Hag-Tae;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1313-1318
    • /
    • 2011
  • This paper proposes a protocol integration system with multi-threading method for the ship electronic devices to solve problems with the compatibility. The proposed protocol integration system receives the different signals from each of the ships' devices through the RS-232 serial communication port and then divides the input signal into the field data. The required field data for standard signal composition are extracted from among these signal and these are combined in accordance with standard signal format. Thereafter, the protocol integration system transmits the processed standard signal to the auto pilot system through a single port.

Smart Phone Based Infrared Remote Controller without Restriction of Target Devices (대상 기기에 제한이 없는 스마트폰 기반의 적외선 리모컨)

  • Hwang, Seong-Jin;Lee, Mi-Hyun;Hong, Jeong-Pyo;Park, Tae-Geun;Kim, Yong-Seok
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.27-32
    • /
    • 2014
  • Infrared remote controllers are widely used in controlling electronic devices due to its simplicity and convenience. This paper presents a smart phone application unifying any infrared remote controllers. We can select a device from device list menu of the application. Any new device can be added easily by downloading the protocol file of the device from protocol file server. Remote controller protocol files are stored in audio file format, and the file related to a specific menu button is transmitted through the audio jack of smart phones. The protocol file server is a standard file server, and protocol files for various devices are collected by infrared receiver module. For smart phones without infrared facility, a small infrared module translating audio signal to infrared signal is applied.

  • PDF

A study on BEMS-linked Indoor Air Quality Monitoring Server using Industrial IoT

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • In this paper, we propose an interworking architecture for building indoor air quality monitoring server (BEMS) using IIoT (Industrial Internet of Things). The proposed monitoring server adopts IIoT-based standard protocol so that interaction with BEMS installed in existing buildings can be performed easily. It can effectively communicate with indoor air quality measurement sensor installed in the building based on IIoT, Indoor air quality monitoring is possible. We implemented a proposed monitoring server, and confirmed the availability and monitoring of data from sensors in the building.

Optimal Polling Method for Improving PCF MAC Performance in IEEE 802.11 Wireless LANs (IEEE 802.11 무선랜 시스템에서 PCF 프로토콜의 성능을 향상시키기 위한 최적의 폴링 방식)

  • Choi, Woo-Yong;Lee, Sang-Wan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • A modified PCF(Point Coordination Function) protocol with the optimal polling sequence is defined in detail and shown to improve the efficiency of the conventional PCF protocol in IEEE 802.11 wireless LAN standard. The problem for the optimal polling sequence is formulated as TSP(Travelling Salesman Problem) with the distance values of 1's or 0's. Numerical examples show that the optimal polling sequence increases the capacity of the real-time service such as VoIP(Voice over Internet Protocol).

RMT: A Novel Algorithm for Reducing Multicast Traffic in HSR Protocol Networks

  • Nsaif, Saad Allawi;Rhee, Jong Myung
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.123-131
    • /
    • 2016
  • The high-availability seamless redundancy (HSR) protocol is one of the most important redundancy IEC standards that has garnered a great deal of attention because it offers a redundancy with zero recovery time, which is a feature that is required by most of the modern substation, smart grid, and industrial field applications. However, the HSR protocol consumes a lot of network bandwidth compared to the Ethernet standard. This is due to the duplication process for every sent frame in the HSR networks. In this paper, a novel algorithm known as the reducing multicast traffic (RMT) is presented to reduce the unnecessary redundant multicast traffic in HSR networks by limiting the spreading of the multicast traffic to only the rings that have members associated with that traffic instead of spreading the traffic into all the network parts, as occurs in the standard HSR protocol. The mathematical and the simulation analyses show that the RMT algorithm offers a traffic reduction percentage with a range of about 60-87% compared to the standard HSR protocol. Consequently, the RMT algorithm will increase the network performance by freeing more bandwidth so as to reduce HSR network congestion and also to minimize any intervention from the network administrator that would be required when using traditional traffic filtering techniques.

Develpoment of Automatic Meter Reading Program for Electronic Power Meter (전자식 전력량계용 한전 프로토콜 및 운영 프로그램 개발)

  • Yu, In-H.;Jang, Mun-J.;Hyun, Duk-H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2219-2221
    • /
    • 2001
  • A communication protocol for automatic meter reading is designed for electronic power meter. Communicational functions and data structures are standardized and data reading software is developed according to the developed protocol. The communication protocol is designed with reference specifications, IEC 62056-31 and Distributed Network Protocol(DNP). For design, communicational functions and specifications of the industrial meters were analyzed for the purpose of developing a new one for KEPCO meters. The protocol is designed with 3 layer model, physical layers, data link layer and application layer. A documentation was completed with data gathering, data classification, authentication, error detection. An emulator system was made for testing the protocol. A meter reading software was developed using the protocol. Many different protocols and meter reading softwares are integrated into one with the developed protocol and software as KEPCO's standard.

  • PDF

Security Threats Analysis and Security Requirement for Industrial Wireless Protocols : ISA 100.11a and WirelessHART (ISA 100.11a 및 WirelessHART 기반 보안위협 식별 및 보안요구사항 도출 연구)

  • Jeong, Jae-Han;Kwon, Sung-Moon;Shon, Tae-Shik
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.1063-1075
    • /
    • 2019
  • In recent years, industrial automation has been established and WISN (Wireless Industrial Sensor Network) has been introduced for efficient system management. By introducing WISN, many engineering costs have been reduced and process processors have been optimized. And communication flow using wireless is increasing. An empirical study on industrial wireless sensor networks is actively conducted, but there are few security studies on them and they are exposed to such threats. If there is a problem with the standard of the wireless communication protocol itself, the device that is certified according to the standard may also be subject to security threats including problems. We analyze security functions and threats of ISA 100.11a and WirelessHART protocol stack based on standards. Procedures for distributing the security key are not provided or it is vulnerable using the Global Data Link key when the device enters the network. This paper presents the problems of the standard itself and presents the security requirements accordingly.

Optimal design of DNP 3.0 network for the Distribution Automation System (배전자동화통신망을 위한 DNP 3.0 최적 설계 방안)

  • Kim, Tae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.422_423
    • /
    • 2009
  • DNP 3.0 is the most widely used data communication protocol for electric power control systems. KEPCO(Korea Electric Power Corporation) also uses DNP 3.0 as a data transmission protocol for the DAS(Distribution Automation System) and the SCADA system of the transmmission system. But DNP 3.0 is one of the oldest industrial standard having many restrictions and there are many considerations for optimal design of DNP 3.0 network for the Distribution Automation System.

  • PDF

Design and Implementation of USN Protocol for Managing Rooms in a Large Building (대형 건축물 객실 관리를 위한 USN 프로토콜 설계 및 구현)

  • Jeong, Woo-Jeong;Yoo, Kwan-Hee;Kim, Jong-Heon;Kim, Tae-Ho;Choi, Sung-Chul;Jeong, Kyu-Seuk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.491-496
    • /
    • 2009
  • In this paper, we propose USN Protocol of Room Control with high efficiency and new routing techniques. I establish a network of cluster hierarchy structure under bases standard for IEEE 802.15.4 and another networks to manage each room use a control packet transmitted and The proposed protocol does not perform BroadCast over a network and transmits a packet to same layer to the destination and then passes the packet after doing searches. If a destination to be transmitted cannot be looked up, the protocol transmits AODV routing packet so that not only traffic load of a wireless network is decreased, but also efficient routing path can be obtained.

  • PDF