• Title/Summary/Keyword: Induction effect

Search Result 2,983, Processing Time 0.025 seconds

A Study on the Coordinate Estimate Algorithm of the Electromagnetic Induction Based Wired Tablet Device (전자기 유도 방식을 이용한 유선 태블릿의 좌표 측정 알고리즘 연구)

  • Hong, Dong-Goo;Ryu, Young-Kee;Oh, Chun-Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.153-159
    • /
    • 2009
  • In this paper, we deal with the coordinate estimate algorithm of the wired tablet device. In order to got the position of the electric pen on the tablet, electromagnetic induction effect is used. Most electric tablets have used the electromagnetic induction effect. Tracking the position of the pen on a tablet that is directly related with the performance of the device is very important. In this research, a new real time coordinate estimate algorithm is introduced. To estimate the position of the pen, the electromagnetic induced signals og the wired tablet are used.

  • PDF

The analysis for the effect of switching surge of induction motor using EMTP (EMTP를 이용한 유도전동기의 스위칭 써지 영향 분석)

  • Song, Seung-Youp;Kim, Jae-Chul;Lee, Do-Hoon;Sin, Jung-Eun;Noh, Kwang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.278-280
    • /
    • 2003
  • As the use of ASD due to developing of power electronics technology was increased, the failure of induction motor by switching surge also was increased. This paper presented a switching surge modeling of inverter and a induction motor modeling using EMTP program. As a output waveform of square wave inverter and PWM inverter and the input terminal waveform of induction motor were shown, the effect of switching surge was analyzed.

  • PDF

Effect of Fluoxetine on the Induction of Long-term Potentiation in Rat Frontal Cortex

  • Kim, Hwang-Soo;Kim, Hyun-Sok;Hahn, Sang-June;Kim, Myung-Jun;Yoon, Shin Hee;Jo, Yang-Hyeok;Kim, Myung-Suk;Rhie, Duck-Joo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.6
    • /
    • pp.295-300
    • /
    • 2004
  • Serotonin (5-hydroxytroptamine, 5-HT) has been shown to affect the induction of long-term potentiation (LTP) in the cortex such as the hippocampus, the visual cortex and the prefrontal cortex. Fluoxetine, as a selective serotonin reuptake inhibitor, is used in the management of a wide variety of psychological diseases. To study the effect of fluoxetine on the induction of LTP, we recorded the field potential in layer II/III of the frontal cortex from 3-wk-old. LTP was induced in horizontal input by theta burst stimulation (TBS). TBS with two-folds intensity of the test stimulation induced LTP, which was blocked by application of D-AP5 $(50 {\mu}M)$, an NMDA receptor antagonist. Whereas bath application of 5-HT $(10 {\mu}M)$ inhibited the induction of LTP, treatment with the 5-HT depleting agent, para-chloroamphetamine $(PCA,\;10{\mu}M)$, for 2hr did not affect the induction of LTP. Bath application of fluoxetine (1, 3, and $10 {\mu}M)$ suppressed the induction of LTP in concentration-dependent manner, however, fluoxetine did not inhibit the induction of LTP in 5-HT-depleted slices. These results indicate that fluoxetine may inhibit the induction of LTP by modulating serotonergic mechanism in the rat frontal cortex.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Effect of Induction Temperature on the $P_L$ Promoter Controlled Production of Recombinant Human Interleukin-2 in Escherichia coli

  • Lee, In-Young;Kim, Myung-Kuk;Lee, Sun-Bok
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.1
    • /
    • pp.26-34
    • /
    • 1992
  • The effect of induction temperature on fermentation parameters has been investigated extensively using Escherichia coli M5248[pNKM21], a producer of recombinant human interleukin-2 (rhIL-2). In this recombinant microorganism, the gene expression of rhIL-2 is regulated by the cI857 repressor and $P_L$ promoter system. The recombinant fermentation parameters studied in this work include the cell growth, protein synthesis, cell viability, plasmid stability, $\beta$-lactamase activity, and rhIL-2 productivity. Interrelationships of such fermentation parameters have been analyzed through a quantitative assessment of the experimental data set obtained at eight different culture conditions. While the expression of rhIL-2 gene was repressed at culture temperatures below $34^\circ{C}$ with little effect on other fermentation parameters, under the conditions of rhIL-2 production $>(36~44^\circ{C})$ the cell growth, plasmid stability, and $\beta$-lactamase activity were, as induction temperature was increased, more profoundly reduced. Although the rhIL-2 content in the insoluble protein fraction was maximum at $40^\circ{C}$, total rhIL-2 production in the culture volume was found to be highest at the induction temperature of $36^\circ{C}$. This was in contrast to the previously known optimum induction temperature of the P$_{L}$ promoter system $>(40~42^\circ{C})$.Explanations for such a discrepancy have been proposed based on a product formation kinetics, and their implications have been discussed in detail.l.

  • PDF

Developmental Switch of the Serotonergic Role in the Induction of Synaptic Long-term Potentiation in the Rat Visual Cortex

  • Park, Sung-Won;Jang, Hyun-Jong;Cho, Kwang-Hyun;Kim, Myung-Jun;Yoon, Shin-Hee;Rhie, Duck-Joo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.1
    • /
    • pp.65-70
    • /
    • 2012
  • Synaptic long-term potentiation (LTP) and long-term depression (LTD) have been studied as mechanisms of ocular dominance plasticity in the rat visual cortex. Serotonin (5-hydroxytryptamine, 5-HT) inhibits the induction of LTP and LTD during the critical period of the rat visual cortex (postnatal 3~5 weeks). However, in adult rats, the increase in 5-HT level in the brain by the administration of the selective serotonin reuptake inhibitor (SSRI) fluoxetine reinstates ocular dominance plasticity and LTP in the visual cortex. Here, we investigated the effect of 5-HT on the induction of LTP in the visual cortex obtained from 3- to 10-week-old rats. Field potentials in layer 2/3, evoked by the stimulation of underlying layer 4, was potentiated by theta-burst stimulation (TBS) in 3- and 5-weekold rats, then declined to the baseline level with aging to 10 weeks. Whereas 5-HT inhibited the induction of LTP in 5-week-old rats, it reinstated the induction of N-methyl-D-aspartate receptor (NMDA)-dependent LTP in 8- and 10-week-old rats. Moreover, the selective SSRI citalopram reinstated LTP. The potentiating effect of 5-HT at 8 weeks of age was mediated by the activation of 5-$HT_2$ receptors, but not by the activation of either 5-$HT_{1A}$ or 5-$HT_3$ receptors. These results suggested that the effect of 5-HT on the induction of LTP switches from inhibitory in young rats to facilitatory in adult rats.

Analysis on the Effect of LCR Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter (멀티레벨 인버터 구동 고압유도전동기에시 발생하는 과도과전압 저감을 위한 LCR필터의 효과분석)

  • Kim, Jae-Chul;Kwon, Young-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.45-52
    • /
    • 2006
  • In this paper, we analyze on the effect of LCR filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage that it was occurred in inverter appears transient overvoltage at the motor input terminal. the transient overvoltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of transient overvoltage appears more serious in high voltage induction motor than low voltage induction motor. We selected LCR filter for reduction of the transient overvoltage. Consequently, we demonstrated that the LCR filter connected to the invertor output terminals greatly reduces the transient voltage stress and ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

Constructed Sound Field of an Induction Motor Using Cylindrical Acoustic Holography (원통형 음향 홀로그래피를 이용하여 구성한 유도전동기의 방사 음장)

  • 김시문;김양한
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.919-929
    • /
    • 1997
  • Induction motors are used in many areas to transform electrical energy to mechanical energy. In the design of an induction motor, not only energy efficiency but also noise becomes an important factor. To effectively address the noise problem, it will be convenient if one can see where and how noise is generated and propagated. In this study sound radiation by an induction motor is visualized using cylindrical acoustic holography. To minimize the bias error by window effect Minimum Error Window(MEW) is used. Its performance is verified by numerical simulations. Based on these theoretical understanding, sound pressure measurement with an induction motor are performed. Not only sound radiation are visualized but sound pressure level and sound power level are also estimated. Results show that the main source is located at nearly bottom part of the motor and the total sound pressure level is 49dB, which satisfies the guideline value suggested by the KS C 4202.

  • PDF

A Study on the 2nd Exitation for CVCF Generation of Doubly-fed Induction Generator (권선형 유도발전기의 CVCF 발전을 위한 2자여자제어법에 관한 연구)

  • 안진우;황영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.656-663
    • /
    • 1991
  • This paper deals with the control strategy for the constant voltage, constant frequency (CVCF) generation of doubly -fed induction generator. Since induction machine is a nonlinear and multivariable one, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and study the effect of its parameters, the control equation of induction machine is derived and tested. The simulation and test results show that suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF