• Title/Summary/Keyword: Induction Coil

Search Result 245, Processing Time 0.023 seconds

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Robust Design for Parts of Induction Bolt Heating System (유도가열시스템의 구성부품에 대한 강건설계)

  • Kim, Doo Hyun;Kim, Sung Chul;Lee, Jong Ho;Kang, Moon Soo;Jeong, Cheon Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.10-17
    • /
    • 2021
  • This paper presents the robust design of each component used in the development of an induction bolt heating system for dismantling the high-temperature high-pressure casing heating bolts of turbines in power plants. The induction bolt heating system comprises seven assemblies, namely AC breaker, AC filter, inverter, transformer, work coil, cable, and CT/PT. For each of these assemblies, the various failure modes are identified by the failure mode and effects analysis (FMEA) method, and the causes and effects of these failure modes are presented. In addition, the risk priority numbers are deduced for the individual parts. To ensure robust design, the insulated-gate bipolar transistor (IGBT), switched-mode power supply (SMPS), C/T (adjusting current), capacitor, and coupling are selected. The IGBT is changed to a field-effect transistor (FET) to enhance the voltage applied to the induction heating system, and a dual-safety device is added to the SMPS. For C/T (adjusting current), the turns ratio is adjusted to ensure an appropriate amount of induced current. The capacitor is replaced by a product with heat resistance and durability; further, coupling with a water-resistant structure is improved such that the connecting parts are not easily destroyed. The ground connection is chosen for management priority.

The Development of Detection System of Conveyer Belt Damage using Magnetic Flux (자기장을 이용한 컨베이어 벨트 파손 감지장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.815-822
    • /
    • 2013
  • In this paper, the research is to develop a system that can detect the breakage of the rubber belt conveyor system in the transport of the raw materials required for the operation of logistics. We are to develop a system that can detect the breakage of the belt due to the electronic system of belt breakage occurs by placing the material on the inside of the belt, electric induction to minimize the damage of the belt. The belt repair costs, or reorder the steps of the logistics transit time can be reduced. Induced in the coil, and belt embedded in the transmitted signal as a way to detect the breakage of the belt was to detect the damage of the belt by detecting the electrical phenomena induced in the coil at the receiving end.

The Investigation of Magnetic Material Characteristic for Solenoid Valve Development (솔레노이드 밸브 개발을 위한 자성소재 특성 조사)

  • Kim, Byung-Hun;Yi, Moo-Keun;Kwon, Oh-Sung;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.817-820
    • /
    • 2011
  • The solenoid valve is an electro-mechanical device that converts electrical energy into mechanical motion. The magnetic field of solenoid is very closely related to the number of coil winding, the intensity of current and the characteristic of magnetic material. There are disadvantages that the weight and size of valve increase, as increasing the number of coil winding, the intensity of current to augment the magnetic force. Therefore, the selection of magnetic material is very important to reduce the weight and size of solenoid valve.

  • PDF

The basic research of transcutaneous energy transmission system for totally implantable artificial heart (체내 이식형 인공심장의 무선에너지 전송 시스템에 관한 기초적 연구)

  • Kim, J.H.;Kim, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.407-410
    • /
    • 2002
  • As a part of electro-mechanical totally implantable artificial heart, a transcutaneous energy transmission system has been developed. By mutual magnetic induction between the first coil on the skin and the subcutaneously implanted second coil, the system transfers electrical power through the skin. This research aimed a minimizing the size of the implanted part as well as maximizing the transfer efficiency. When an air gap is 1$\sim$2cm, voltage gain and current gain low and it is hard to transfer energy due to large leakage flux. That is, the required input voltage and input current must be large compared with the output voltage and output current, respectively, This paper research the inverter topology and the control method in order to increase the voltage gain and the current gain. For this purpose, this inverter employs double tune to compensate the large leakage inductance of primary and secondary of the transcutaneous transformer. And the output energy of transcutaneous energy transmission system supply for Lithium-ion battery charger.

  • PDF

Development of Transcutaneous Energy Transmission System for Medical Instrument (의료용 무선 에너지 전달 장치의 개발)

  • 안재목;이동준
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.447-456
    • /
    • 1995
  • As a part of electro-mechanical totally implantable artificial heart (TIAH) program, a transcut- aneous energy transmission system has been developed. By mutual magnetic induction between the first coil on the skin and the subcutaneously implanted second coil, the system transfers elctrical power through the skin. This research aimed at minimizing the size of the implanted part as well as maximizing the transfer efficiency. Using class I amplifier, we achieved above 75% power transfer efficiency at average 40W power transfer level which is required for normal TIAH operation. In vivo performance of the developed system and bio-compatibility of the material used in Implanted parts were evaluated through animal experiments.

  • PDF

The Effect of Coil Shape on the Electromagnetic Force in the Cylindrical Electromagnetic Pump Using Linear Traveling Traveling Magnetic Field (선형 이동 자기장을 사용한 원통형 전자기 펌프의 전자기력에 미치는 코일 모양의 영향)

  • 이경우;정순효;오영주;조영환;심재동
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.892-899
    • /
    • 1995
  • A numerical simulation program based on the finite elerrent method is developed for calculating electromagnetic field of the cylindrical electromagnetic pump. The calculated results by the developed program show that Lorentz forces show maximum peak at an optimum length ($L_c$) of the induction coil. The value of $L_c$ depends on the radius of the molten metal when the skin depth is large. On the other hand, the value of $L_c$ depends on the skin depth when it is small.

  • PDF

Optimal Design of a Coil for Improved Heating Efficiency of Electric Induction Boiler (전기유도보일러의 발열효율개선을 위한 권선최적설계)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.476-482
    • /
    • 2019
  • Regulatory protocols such as the Convention on Climate Change and the regulation of greenhouse gas emissions act as catalysts for the development of high-efficiency energy equipment and the efficient use of energy. Among the fields where energy consumption is high, the electric heating equipment is not efficient. The electric boiler mainly uses a method of circulating water by contacting the heater. When the existing electric boiler is used, the water minerals are contacted with the high-temperature heater to be carbonized and adsorbed, thereby promoting the corrosion of the heater and lowering the efficiency of the heater. For this reason, an electric induction boiler, which has high energy efficiency and is applied to an induction heating system that can uniformly heat the object to be heated rather than conduction or convection heating, is in the limelight. This method induces a boiler pipe And it is recognized as an alternative that can solve the problem that occurs when heating is performed by direct heating. Despite the fact that research on induction heating has been conducted for a relatively long period of time, there have been few studies on the electrothermal technology using induction heating. Therefore, in this paper, to improve the heat efficiency of electric induction boiler, the influence of the cross sectional area, number of windings and winding layers is analyzed by finite element method through parametric study method. The method of finding the design point which maximizes the total loss is proposed by the alternating winding design method which can maximize the heat generation by analyzing copper and iron losses.

Isolation, Purification and Characterization of Polysaccharides that induce in vitro Immuno-Stimulation of Macrophases derived from Liquid Culture of Cordyceps militaris

  • Kwon, Jeong-Seok;An, Hyo-Sil;Hong, Eock-Kee
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.287-292
    • /
    • 2005
  • The crude polysaccharides(C-CPF, C-CPM, C-CPB) derived from fruiting body, mycelia and mycelia free broth of cordyceps militaris were obtained by ethanol precipitation of hot water extracts. After a batch fermentation of C. militaris was carried out in a 5 L jar vessel, endo-polysaccharide and exo-polysaccharide were obtained. They were demonstrated as the hetero polysaccharides which were composed of glucsose, galactose and mannose by performed with HPAEC(high pH anion exchange chromatography) and conformation of random coil by its complex forming ability with congo red reagent. They were purified by ion exchange (DEAE-cellulose) and gel filtration chromatography. They were monitered by phenol-sulfuric acid method and Bradford method. The NO induction activities of crude polysaccharides and purified polysaccharides derived from mycelia free broth were enhanced rather than LPS(lipo polysaccharide) which was used as a general NO inducer. These effects presumably contibute to the antitumor activities. The homogenieties and molecular weights of polysaccharides were determined by using Sepharose CL-6B. The yield, molecular weights and NO induction activities of C-CPFN Fr.III, C-CPMN Fr.III, C-CPBN Fr.II were 0.387, 0.408 and 0.153, 127 K 210 K and 36 K, 40.79%, 88.72%, and 104.17%, respectively.

  • PDF

Signal Processing for Pulse Induction Metal Detector (자성센서 기반 지뢰탐지기를 위한 신호처리)

  • Shin, Beom-Su;Yang, DongWon;Jung, Byung-Min
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.532-538
    • /
    • 2018
  • This paper proposes an algorithm for signal processing which is used in pulse induction metal mine detectors. The detection power can be obtained from magnetic variation on the search coil. The calibration data should be made when there is no target because the detection power is difference between with and without a target. And it is also updated periodically because of surrounding various noises. Lastly, we keep a watch on the signal slope to identify exact position and signal power of mine detection.