• 제목/요약/키워드: Inductance saturation

검색결과 80건 처리시간 0.023초

유도전동기 드라이브 시스템의 효율성능을 예측하기 위한 손실 모델링 (Loss Modeling in order to Predict the Efficiency Performance of Induction Motor Drive System)

  • 정동화;박기태;이정철
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.56-61
    • /
    • 2000
  • The precise and reliable loss model for induction motor and converter system is very important in order to predict the efficiency performance of variable speed drives. This paper proposes an accurate loss model of induction motor and converter system. The motor losses, such as stator and rotor copper loss, core loss and stray loss, are considered for fundamental and harmonic frequencies. Also considered are the skin effect on rotor resistance, temperature effect on bath stator and rotor resistance, magnetizing inductance saturation, and friction and windage loss. All the above features are incorporated in a synchronous frame dynamic d-q equivalent circuit. The converter system, consisting of a diode rectifier and PWM transistor inverter, is modeled accurately for conduction and switching losses. Validity of the models, in both steady state and transient conditions, is verified by simulations.

  • PDF

저전류 영역에서 로고우스키 코일 특성 (Characteristics of Rogowski coil at Low Cutrrent Region)

  • 박정남;이강원;이청;김길수;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

직통직권 발전기에 의한 직통분권 전동기의 특성해석 (Analysis of D-C Shunt Motor Characteristics, driving D-C Series Generator)

  • 이승원;한송엽
    • 전기의세계
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 1967
  • There are many kinds of motors operating by rated voltage which is constant. In this paper, the characteristics of separately excited direct current motor is analyzed when its terminal voltage is varied as its load current. As for this source, direct current generator of a series field is used, and it is driven at constant speed by a primemover. The induced voltage of the generator is propotional to its load current but it saturates as its load current is large. The charateristics of motor is studied by analog computer because of the nonlinearity of generator. The results are as follows: (1) The load current and the rotor speed of motor increase as the load of motor increases. But the speed of rotor decreases for the influence of the saturation of the iron of generator field when its load current is large. (2) Decreasing the inertia of motor and increasing the inductance of the armature circuit improve the stability of motor and the region of stable state. (3) By changing the field current of the motor, the speed and the direction of rotor can be controlled in wide range.

  • PDF

고출력 응용을 위한 영구자석 매입형 동기 릴럭턴스 전동기의 특성해석 (Characteristic Analysis of Permanent Magnet Assisted Synchronous Reluctance Motorfor High Power Application)

  • 장영진;김상길;신흥교;박성준;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.914-916
    • /
    • 2004
  • In this paper, finite element analysis for a PMASynRM is presented and the characteristic analysis of inductance and torque is performed under the effect of saturation. The focus of this paper is characteristic analysis of d and q-axis inductances and torque according to magnetizing quantity of interior permanent magnet for PMASynRM. The d and q-axis current component ratios, load angles of a PMASynRM are investigated quantitatively on the basis of the proposed analysis method and the experimental test. Comparisons are given with output characteristic curves of normal SynRM and those according to the load in PMASynRM, respectively. And it is confirmed that the proposed model results in high output power performance.

  • PDF

최소자승법과 자기 인덕턴스 포화현상을 이용한 매입형 영구자석 동기전동기의 초기 위치 추정 (Initial Rotor Position Estimation of Interior Permanent Magnet Synchronous Motor using Least Squares Method and Self-Inductance Saturation)

  • 김건영;신혜웅;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.158-159
    • /
    • 2017
  • 본 논문에서는 매입형 영구자석 동기전동기를 위치센서 없이 기동하기 위해 회전자의 초기 위치를 추정하는 방법을 제안한다. 제안된 방법은 자기 인덕턴스의 포화현상에 따른 고정자 전류를 해석하고 최소자승법을 통해 회전자의 초기 위치를 추정한다. 전 구간에서 회전자의 초기 위치와 극성을 정확하게 알아낼 수 있어 돌극성 때문에 나타나는 릴럭턴스 토크를 효과적으로 사용할 수 있다. 또한, 전동기 정수에 영향을 받지 않으므로 다양한 전동기 구동 시스템에 적용할 수 있으며, 추가적인 하드웨어가 필요하지 않아 경제적이다. 제안하는 방법의 유효성과 우수성은 시뮬레이션을 통해 검증한다.

  • PDF

자속구속형 고온초전도 사고전류 제한기의 히스테리시스 특성 분석 (Analysis on Hysteresis Characteristics of Flux-Lock Type HTSC Fault Current Limiter)

  • 임성훈;한병성;박형민;조용선;한태희;두호익;최효상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.493-495
    • /
    • 2006
  • The hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type superconducting fault current limiter (SFCL), was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio for the 1st and 2nd windings, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

전기적인 파라메터 변화에 따른 스위치드 릴럭턴스 전동기의 힘특성 해석 (Analysis of Force Characteristic in Switched Reluctance Motor According to Electric)

  • 전연도;이철직;이택기;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.122-124
    • /
    • 2001
  • In this paper, the influence of electrical parameters such as the turn-on and turn-off angle on the torque and force characteristics is investigated for the reduction of the torque ripple which is main source of vibration and noise in switched reluctance motor (SRM). The four different types of the turn-on angle are set to the section of rising inductance profile respectively. The optimum turn-on angle is proposed for the acquisition of the flat current shape minimizing the torque ripple. 2D finite element method (FEM) considering the iron saturation and the actual switching circuit of the SRM drive is applied for the dynamic analysis. The simulation results of phase current and torque are also compared to the experimental results.

  • PDF

Flux Linkage Estimation in a Switched Reluctance Motor Using a Simple Reluctance Circuit

  • Lee, Cheewoo
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.57-64
    • /
    • 2013
  • Flux linkage of phase windings is a key parameter in determining the behavior of a switched reluctance motor (SRM) [1-8]. Therefore, the accurate prediction of flux linkage at aligned and unaligned rotor positions makes a significant contribution to the design of an SRM and its analytical approach is not straightforward due to nonlinear saturation in flux. Although several different approaches using a finite element analysis (FEA) or a curve-fitting tool have been employed to compute phase flux linkage [2-5], they are not suitable for a simple design procedure because the FEA necessitates a large amount of time in both modeling and solving with complexity for every motor design, and the curve-fitting requires the data of flux linkage from either an experimental test or an FEA simulation. In this paper, phase flux linkage at aligned and unaligned rotor positions is estimated by means of a reluctance network, and the proposed approach is analytically verified in terms of accuracy compared to FEA.

직접토크제어에 의한 위치검출기 없는 릴럭턴스 동기전동기의 위치 제어시스템 (A High-Performance Position Sensorless Motion Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김동희;김민회;김남훈;배원식
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.427-436
    • /
    • 2002
  • 본 논문은 직접토크제어(Direct torque control, DTC)를 사용한 릴럭턴스 동기전동기(Reluctance synchronous motor, RSM)의 위치센서 없는 모션제어 시스템을 제안한다. 고성능 효율제어를 수행하는데 있어서 DTC를 이용한 릴럭턴스 전동기 드라이브는 고정자 쇄교자속의 포화와 부하전류에 따라 비선형적으로 변하는 인덕턴스로 인해 여러 가지 문제점들이 발생한다. 이러한 이유로 본 논문에서는 정확한 고정자 쇄교자속과 토크를 계산하기 위해서 자속관측기의 $L_d\;와\; L_q$값을 회전자 위치와 고정자 전류에 대해 보상하였으며, 빠른 토크 응답특성과 최적 효율특성을 얻기 위해서 기준자속을 부하에 따라 계산하였다. 제안된 알고리즘의 정당성을 확인하기 위해서 1.0[kW] 릴럭턴스 동기 전동기를 사용하여 $\pm$20[rpm]과 $\pm$1500[rpm]에서 실험을 수행하였고, 실험을 수행한 결과 저속영역과 고속영역 모두 우수한 동특성과 향상된 효율을 얻을 수 있었다.

히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석 (Analysis on Fault Current Limiting Characteristics of a Flux-Lock Type HTSC Fault Current Limiter with Hysteresis Characteristic)

  • 임성훈;최명호
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.94-98
    • /
    • 2007
  • 자속구속형 초전도 사고전류 제한기는 평상시 자기적인 결합에 의해 철심의 히스테리시스 손실이 발생하지 않는 특징이 있다. 그러나 사고시에는 사고전류증가로 인해 고온초전도 소자의 저항발생과 함께 철심의 포화가 발생할 경우 제한기의 사고전류제한 특성을 저하시키는 현상이 발생하게 된다. 따라서 본 논문에서는 이를 분석하고 억제하기 위한 설계방안을 도출하기 위해 자속구속형 고온초전도 사고전류 제한기의 구성요소인 자속구속 리액터의 히스테리시스 특성을 고려한 사고전류 제한특성을 분석하였다. 이를 위해 제한기의 등가회로와 사고전류 제한실험으로부터 히스테리시스 곡선을 도출하였다. 1, 2차권선의 인덕턴스 비에 따른 히스테리시스 곡선으로부터 인덕턴스비가 증가함에 따라 제한되는 사고전류크기는 증가한 반면 사고시 자속구속형 사고전류제한기의 구성요소인 철심의 포화가 억제됨을 확인할 수 있었다.